Aerodynamic thermal simulation system. Part 1: Radiant array (instruction manual)

An aerodynamic thermal simulation system (ATSS) is presented. The construction of the system, the maintenance, set up, and operations are reported. System description of the radiant array is given along with the array subsystems modular heating unit, adjustable stanchion frame, cooling water system, and the gaseous nitrogen cooling system. The array configuration procedure outlines the set up and the start up. Maintenance procedures involve both lamp maintenance and reflector maintenance along with weather protection. Drawing codes are included. Descriptions of the 36 zone ATSS controls are also given. Each zone is an independent closed loop temperature control circuit. Procedures are presented for starting and stopping the system. The DATA-TRAK programmer and its operation, instruction manuals for the temperature controller and the power regulator and discriptions of peripheral equipment are discussed.

Kitchar, A. F.↗

Thermal performance of a multi-evaporator loop heat pipe with thermal masses and thermal electrical coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermal electric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of condenser is fully utilized. Ammonia was used ad the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 1OW even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/-0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing the orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

loop heat pipes↗

Thermal Performance of a Multi-Evaporator Loop Heat Pipe with Thermal Masses and Thermoelectric Coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermoelectric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of the condensers is fully utilized. Ammonia was used as the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 10W even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/- 0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5 ) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

Ku, Jen-Tung↗

Process modelling for materials preparation experiments

The main goals of the research under this grant consist of the development of mathematical tools and measurement techniques for transport properties necessary for high fidelity modelling of crystal growth from the melt and solution. Of the tasks described in detail in the original proposal, two remain to be worked on: development of a spectral code for moving boundary problems, and development of an expedient diffusivity measurement technique for concentrated and supersaturated solutions. We have focused on developing a code to solve for interface shape, heat and species transport during directional solidification. The work involved the computation of heat, mass and momentum transfer during Bridgman-Stockbarger solidification of compound semiconductors. Domain decomposition techniques and preconditioning methods were used in conjunction with Chebyshev spectral methods to accelerate convergence while retaining the high-order spectral accuracy. During the report period we have further improved our experimental setup. These improvements include: temperature control of the measurement cell to 0.1 C between 10 and 60 C; enclosure of the optical measurement path outside the ZYGO interferometer in a metal housing that is temperature controlled to the same temperature setting as the measurement cell; simultaneous dispensing and partial removal of the lower concentration (lighter) solution above the higher concentration (heavier) solution through independently motor-driven syringes; three-fold increase in data resolution by orientation of the interferometer with respect to diffusion direction; and increase of the optical path length in the solution cell to 12 mm.

Rosenberger, Franz↗

Better Thermal Insulation in Solar-Array Laminators

Glass marbles improve temperature control. Modified vacuum laminator for photovoltaic solar arrays includes thermal insulation made of conventional glass marbles. Marbles serve as insulation for temperature control of lamination process at cure temperatures as high as 350 degrees F. Used to replace original insulation made of asbestos cement.

Burger, D. R.↗

Reducing Sample Loss in Measurement of Heat of Vaporization of Ethanol/Gasoline Blends by Differential Scanning Calorimetry/Thermogravimetric Analysis

Higher gasoline Heat of Vaporization (HOV) can enable higher compression-ratio direct injection spark ignition engines by providing evaporative cooling that effectively increases fuel knock resistance. Methods to directly measure this fuel property in complex gasoline samples are not well developed. The objective of the present study was to further improve a Differential Scanning Calorimetry/Thermogravimetric Analyzer (DSC/TGA) method to measure the total and partial HOV of gasoline. Ten market gasoline samples were chosen to have a wide range of properties to assess the method's capability across the entire volatility range with an emphasis on understanding how well the method captures the initial 10 percent (%) of sample evaporation and how much sample is left unevaporated at the end of the experiment. Modifications to the sample preparation/introduction method as well as to the instrument itself were made to reduce initial sample losses which included measurements of the HOV at 10 degrees C and 5 degrees C (in a cold chamber) as well as under (uncontrolled) ambient conditions. Experimental results from the DSC/TGA were compared to calculated total HOV results based on Detailed Hydrocarbon Analysis (DHA). Results from the two methods agreed very well with the difference being 5% or less in almost every case. In addition, the repeatability of the method was investigated by analyzing samples in triplicate at the three temperatures investigated. One valuable conclusion from the study was that the lower temperatures of 10 degrees C and 5 degrees C enabled more reproducible measurements for both total and partial HOV. This improved precision may be caused by the fact that temperature control in the cold chamber was more reliable than the ambient laboratory temperature control. Additionally, cold chamber experiments, due to ergonomic limitations, did not allow for the use of a lid on the sample pan. The reproducibility of the evaporation rate was found to be highly dependent on the pan/lid fit which can vary significantly such that elimination of the lid improved measurement precision while operation at sub-ambient temperature slowed the evaporation rate. Results detailing sample preparation and instrument modifications as well as a detailed comparison of total and partial HOV results are presented.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Delta L: An Apparatus for Measuring Macromolecule Crystal Growth Rates in Microgravity

Strongly diffracting high quality macromolecule crystals of suitable volume are keenly sought for X-ray diffraction analysis so that high-resolution molecular structure data can be obtained. Such data is of tremendous value to medical research, agriculture and commercial biotechnology. In previous studies by many investigators microgravity has been reported in some instances to improve biological macromolecule X-ray crystal quality while little or no improvement was observed in other cases. A better understanding of processes effecting crystal quality improvement in microgravity will therefore be of great benefit in optimizing crystallization success in microgravity. In ground based research with the protein lysozyme we have previously shown that a population of crystals grown under the same solution conditions, exhibit a variation in X-ray diffraction properties (Judge et al., 1999). We have also observed that under the same solution conditions, individual crystals will grow at slightly different growth rates. This phenomenon is called growth rate dispersion. For small molecule materials growth rate dispersion has been directly related to crystal quality (Cunningham et al., 1991; Ristic et al., 1991). We therefore postulate that microgravity may act to improve crystal quality by reducing growth rate dispersion. If this is the case then as different, Materials exhibit different degrees of growth rate dispersion on the ground then growth rate dispersion could be used to screen which materials may benefit the most from microgravity crystallization. In order to assess this theory the Delta L hardware is being developed so that macromolecule crystal growth rates can be measured in microgravity. Crystal growth rate is defined as the change or delta in crystal size (defined as a characteristic length, L) over time; hence the name of the hardware. Delta L will consist of an optics, a fluids, and a data acquisition sub-assemblies. The optics assembly will consist of a video microscope camera mounted on three axis computer controlled translation stages. The fluids assembly consists of macromolecule and precipitant reservoirs, a temperature controlled growth cell and waste container, The data acquisition is achieved by using a frame-gabber, with images being stored on a hard drive. In operation, macromolecule and precipitant solution will be injected into the temperature controlled growth cell. As macromolecule crystals grow, the video microscope camera controlled by the translation stages, will be used to locate and record images of individual crystals, returning to the same crystals at specific time intervals. The images will be stored on the hard drive and used to calculate the crystal growth rate. To prevent vibrations interfering in the crystal growth rate measurements (Snell et al., 1997) Delta L will be used in connection with the Glovebox Integrated Microgravity Isolation Technology (g-LIMIT) inside the Microgravity Science Glovebox (MSG), onboard the International Space Station (ISS).

Judge, Russell A.↗

Solid state thermostat has integral probe and circuitry

Compact, reliable thermostat provides a temperature readout signal and a continuous temperature-control output for temperature monitoring by automatic checkout equipment or telemetry systems. It employs a solid state circuit in a housing rigidly attached to a thermistor probe.

Source record↗

Structural active cooling applications for the Space Shuttle.

Analytic and experimental studies have been conducted to evaluate a number of active cooling approaches to structural thermal protection for the Space Shuttle. The primary emphasis was directed toward the thermal protection system. Trade study results are presented for various heat shield material and TPS arrangements. Both metallic and reusable surface insulation (RSI) concepts were considered. Active systems heat sinks consisted of hydrogen, phase change materials, and expendable water. If consideration is given only to controlling the surface temperature, passive TPS was found to provide the most efficient system. Use of active cooling which incorporates some interior temperature control made the thermally less efficient RSI system more attractive.

Masek, R. V.↗

Solar hot water system installed at Day's Inn Motel, Dallas, Texas (Valley View)

The solar system was designed to provide 65 percent of the total domestic hot water (DHW) demand. A liquid (water) flat plate collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank when the solar pump is not running. Heat is transferred from the DHW tanks through a shell and tube heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up standby losses. All pumps are controlled by differential temperature controllers.

Source record↗

Environmental control/life support

It is pointed out that the life support systems technology used on projects Mercury, Gemini, Apollo, and Space Shuttle required an employment of expendables. Skylab was the only manned space project which made use of regenerable life support technology, taking into account the employment of a silica gel/molecular sieve for carbon dioxide removal. A number of investigations indicate that significant launch weight and volume as well as recurring cost savings can be realized by using regenerative life support processes for a Space Station. A number of developed regenerative processes are believed to be applicable to a Space Station. Aspects of air revitalization are discussed, taking into account carbon dioxide reduction, oxygen generation, trace contaminant control, temperature and humidity control, instrumentation, and nitrogen supply. Attention is also given to water reclamation, solid waste treatment, and future development and testing programs.

Quattrone, P. D.↗

The Small Explorer power system electronics

The power system electronics for the NASA Goddard Space Flight Center Small Explorer Satellites are intended to satisfy various planned missions. The selected topology is a direct energy transfer (DET) system with the battery connected directly to the bus. The shunt control technique is a linear sequential full shunt which provides a simple solar array interface and can support both 3 axis stabilized and spinner satellites. In addition, it can meet stringent electromagnetic interference requirements which are expected on some Small Explorer Missions. The Power Systems Electronics (PSE) performs battery charge control using both temperature compensated charge/discharge ratio ampere hour integration and voltage-temperature control. The PSE includes all the circuits needed to perform telemetry and command functions using an optical MIL-STD-1773 interface.

Dakermanji, G.↗

Comparison of automatic control systems

This report deals with a reciprocal comparison of an automatic pressure control, an automatic rpm control, an automatic temperature control, and an automatic directional control. It shows the difference between the "faultproof" regulator and the actual regulator which is subject to faults, and develops this difference as far as possible in a parallel manner with regard to the control systems under consideration. Such as analysis affords, particularly in its extension to the faults of the actual regulator, a deep insight into the mechanism of the regulator process.

Oppelt, W↗

Hydrogen Sensors Demonstrated on the Shuttle

Microelectromechanical-systems- (MEMS-) based hydrogen sensor technology developed by the NASA Glenn Research Center at Lewis Field and Case Western Reserve University was demonstrated on shuttle missions STS-95 (Senator Glenn s mission) and STS-96. These smart sensors, commercialized by Makel Engineering Inc., were part of an "Integrated Vehicle Health Monitoring HEDS Technology Demonstration" series conducted at the NASA Kennedy Space Center. The experiments were designed to demonstrate the effect of technological upgrades on shuttle performance. The hydrogen sensors were micro-fabricated for minimal size, weight, and power consumption. A temperature detector and heater were included on the sensor for temperature control. Two palladium chrome (PdCr) hydrogen detection devices were included in each sensor package: a Schottky diode for low concentrations and a resistor for high concentrations. These sensor designs allow operation in inert environments. "Smart" electronics developed by Makel Engineering were integrated with the sensors to control the sensor temperature and process the output of the various sensors. This complete hydrogen detection system (two sensors on a chip with smart electronics) flew on STS-95 (launched October 1998) and STS-96 (launched May 1999). It was installed in the aft compartment of the shuttle and used to monitor the hydrogen concentration in that region. Up to this time, a mass spectrometer had monitored the hydrogen concentration in the aft compartment before launch, and "grab" bottles had been used after launch. The inside of these bottles is at vacuum. During flight, the grab bottles are pyrotechnically opened for a brief period, and the gas in the aft compartment is captured in the bottle. Several of these bottles are opened at different times during takeoff, and their contents are used to determine the time profile of the gases in the aft chamber. However, this information is not available until after the flight. On the launch pad, results from the new sensor technology paralleled the responses of the mass spectrometer with, in some cases, a quicker response time. In flight, data from the new sensors agreed with those derived from analyzing the contents of the grab bottles. Moreover, this microsensor can monitor the aft compartment continuously and, in principle, could monitor the health of the vehicle in real time during flight.

Hunter, Gary W.↗

Miniature Bioreactor System for Long-Term Cell Culture

A prototype miniature bioreactor system is designed to serve as a laboratory benchtop cell-culturing system that minimizes the need for relatively expensive equipment and reagents and can be operated under computer control, thereby reducing the time and effort required of human investigators and reducing uncertainty in results. The system includes a bioreactor, a fluid-handling subsystem, a chamber wherein the bioreactor is maintained in a controlled atmosphere at a controlled temperature, and associated control subsystems. The system can be used to culture both anchorage-dependent and suspension cells, which can be either prokaryotic or eukaryotic. Cells can be cultured for extended periods of time in this system, and samples of cells can be extracted and analyzed at specified intervals. By integrating this system with one or more microanalytical instrument(s), one can construct a complete automated analytical system that can be tailored to perform one or more of a large variety of assays.

Gonda, Steve R.↗