At least 325 records · Page 18

Testing and Evaluation of Multifunctional Smart Coatings

A smart coating system, based on pH sensitive microcontainers (microparticles and microcapsules) has been developed. Various corrosion inhibitors have been encapsulated and incorporated into commercial and formulated coatings to test the functionality imparted on the coating by the incorporation of the inhibitor microcontainers. Coated carbon steel and aluminum alloy panels were tested using salt immersion, salt fog, and coastal atmospheric exposure conditions. This paper provides the details on coating sample preparation, evaluation methods, as well as test results of the inhibiting function of smart coatings.

Testing and Evaluation↗

Flight test and evaluation of Omega navigation for general aviation

A seventy hour flight test program was performed to determine the suitability and accuracy of a low cost Omega navigation receiver in a general aviation aircraft. An analysis was made of signal availability in two widely separated geographic areas. Comparison is made of the results of these flights with other navigation systems. Conclusions drawn from the test experience indicate that developmental system improvement is necessary before a competent fail safe or fail soft area navigation system is offered to general aviation.

Hwoschinsky, P. V.↗

The Instrumented Walking and Turning Test to Evaluate Suited Gait Dynamics and Performance in Extravehicular Activity Training Environments

Background and aims: Walking will be required for many exploration tasks on the Moon during the Artemis program. Walking in a straight line on the confined floorspace of a testing area, and repetitive treadmill walking that requires no change in direction may not adequately reflect the balance and coordination required during ambulation. Also, performance of turning maneuvers may be affected differently in different extravehicular activity (EVA) training facilities that simulate partial gravity. For example, the Neutral Buoyancy Lab (NBL) simulates lunar gravity by adding weight to underwater subjects to alter buoyancy and achieve the equivalent ground reaction force of 1/6 of Earth’s gravity (1/6G), whereas the Active Response Gravity Offload System (ARGOS) uses a computer controlled overhead suspension system programmed to continuously offload a percentage of a subject’s weight to simulate 1/6G. The degree to which dynamic movements such as turning are comparable across these EVA training facilities has not yet been evaluated. The instrumented gait test helps NASA scientists and engineers evaluate gait dynamics and performance in suited conditions, and this test demonstrates the unique characteristics and limitations of EVA training facilities. We developed an instrumented walking and turning test using inertial measurement units (IMUs) and conducted the test at NASA’s EVA training facilities. Results were used to compare suited walking and turning characteristics in the ARGOS and the NBL. Methods: Subjects donned the Mark III space suit during offloading with the ARGOS spreader bar gimbal and donned the Z2.5 space suit while underwater in the NBL with weights and floatation added to achieve realistic suit center of gravity. The test team securely attached three Opal (APDM, OR, USA) wireless IMUs on the space suit for each test run: one on the middle of the hard upper torso, and one on the left and on the right ankle bearings. During the NBL tests, the IMUs were encased in a waterproof housing (GoPro) with foam added to create a tighter fit. At both testing facilities, 6.3 m x 1.0 m (LxW) walking lines were marked, and a cone for turning or walking around was located at the end of the walking path with another line on the other side of the cone to indicate the stopping point after walking around the cone. Under simulated 1/6G, subjects began by standing at the marked line with their arms folded across the chest, they then walked at a preferred speed along the straight walking path until they reached the end, turned 180 degrees around the cone, and finally stopped at the marked stopping point. All IMU data recorded during testing were automatically saved to the internal memory. Then, raw IMU signals were processed using custom MATLAB (Mathworks, MA, USA) code to compare gait parameters during both the walking and the turning components of the task. These parameters included time (s), speed (m/s for walking and rad/s for turning), step number (n) and walk:turn time ratio (% time spent straight walking versus turning). Results: Less time, faster gait, fewer steps, and higher walk:turn ratio during both walking and turning components were exhibited during tests performed at the ARGOS versus those performed at the NBL. During the NBL tests, the slower walking speed continued at the same rate throughout a U-shape turn. During the ARGOS tests, the subjects performed shorter and tighter turns at 4 times the speed of the NBL turns because they walked 30% faster and the vertical offloading system gave them more support. Conclusion: Our data show that the differences in walking and turning parameters during the NBL tests may be due to the high viscosity in the water environment where the motion of the lower limbs was slow and did not reach full flexion and extension. These tests improve the current knowledge of testing environments in preparation for EVAs on the lunar surface.

Kyoung Jae Kim↗

Development of a Test for Evaluation of the Hydrothermal Stability of Sorbents Used in Closed-Loop CO2 Removal Systems

The International Space Station Carbon Dioxide Removal Assembly uses zeolite 5A molecular sieve material packed into beds for the capture of cabin CO2. The beds are cyclically heated to drive off the CO2 and restore the removal capacity. Over time, the sorbent material has been found to break down resulting in dust that restricts flow through the beds. Humidity adsorbed in the 5A zeolite when it is heated is a suspected cause of this sorbent degradation. To evaluate the impact of adsorbed water during thermal cycling, the Hydrothermal Stability Test was developed. The test configuration provides comparative side-by-side flow restriction data for two sorbent materials at specifically controlled humidity levels. While the initial focus of the testing is on 5A zeolite materials currently used on the ISS, the system will also be used to evaluate future candidate materials. This paper describes the approach, the test system, current results, and future testing.

Knox, James C.↗

Evaluation of tests for vestibular function

Vestibular testing methodologies are examined in terms of their clinical value and applicability to the assessment of astronaut candidates and human responses to microgravity. Classical and novel testing approaches are examined in terms of nine functions such as otolith organs, vestibular neural processing, and ocular motor systems. The tests reviewed include the basic vestibular-function test battery, postural stability testing, visual-vestibular interaction, reactions to off-axis rotation, and vestibular evoked responses. The basic test battery is shown to be essential for astronaut and inertial-environment baseline-data evaluations, whereas the newer and research tests are only recommended in special cases. Stimulus rearrangement and motion-sickness tests are indicated for testing adaptation to inertial environments. Postural stability and visual-vestibular interaction are recommended for evaluating one's suitability for being an astronaut.

Source record↗

Comparison of different plate treatments and designs, an update

Nine packs of cells of different designs were put on test at Crane. They were run through their initial evaluation tests and then put into a cycling test. These were GE 12A h cells. The temperature was 20 C, the orbit was 90 minutes, the depth of discharge was 40%, the discharge rate was 9.6A and the initial charge rate was 9.6A to a voltage limit where it went into a taper. The goal was to get 100% return. The voltage limit was 1.453V through most of the testing, although recently it became necessary to lower some packs and raise some to hold 115% return. After one year, one cell from each pack was removed and the initial evaluation tests were repeated.

Baer, D.↗

Surveillance systems test and evaluation facilities

In January of 1983, a team was formed to explore test methodologies and test facility concepts required to meet the needs of space-based surveillance systems. The output of this study was a road map of test methodologies and test facilities that will aid the development of this country's critical space-based sensor assets. A condensation of those results is given.

Matty, Jere J.↗

Results of an experimental program for the development of sonic inlets for turbofan engines.

Results of a current program for sonic inlet technology development are presented. This program includes configuration and mechanical design selection of concepts, aerodynamic design description of the models, and results of test evaluation. In the test program several sonic inlet concepts were tested and compared for aerodynamic and acoustic performance. Results of these comparative evaluations are presented. Near-field measurements were taken inside the sonic inlet on several inlet models. Results of these tests are discussed with respect to the effect of Mach number gradients on noise attenuation and rotor shock wave attenuation, and boundary layer effects on noise propagation. The test facilities and experimental techniques employed are described briefly.

Klujber, F.↗

Test and evaluation of the generalized gate logic system simulator

The results of the initial testing of the Generalized Gate Level Logic Simulator (GGLOSS) are discussed. The simulator is a special purpose fault simulator designed to assist in the analysis of the effects of random hardware failures on fault tolerant digital computer systems. The testing of the simulator covers two main areas. First, the simulation results are compared with data obtained by monitoring the behavior of hardware. The circuit used for these comparisons is an incomplete microprocessor design based upon the MIL-STD-1750A Instruction Set Architecture. In the second area of testing, current simulation results are compared with experimental data obtained using precursors of the current tool. In each case, a portion of the earlier experiment is confirmed. The new results are then viewed from a different perspective in order to evaluate the usefulness of this simulation strategy.

Miner, Paul S.↗

Mechanical properties of Zircaloy cladding tubes and contributions to M.E.T.A. mechanical property database

To support a multi-laboratory Methodology, Evaluation, Testing, and Analysis (M.E.T.A.) cladding properties database, Oak Ridge National Laboratory’s (ORNL’s) cladding mechanical test geometries were manufactured from several nuclear-relevant cladding alloys and subsequently tested. These geometries were developed as mechanical test specimens to evaluate the properties of tube materials that may be used for irradiation testing at ORNL’s High Flux Isotope Reactor. They may also be used as test articles to be harvested—via in-cell machining—from commercially irradiated fuel rods and later tested. This report explores the differences among axial, hoop, and SSJ tensile geometries with partially recrystallized Zircaloy-2 to test ORNL correlation-based methods on a plate material that approximates, to the greatest extent possible, the characteristics of nuclear industry tubing. Furthermore, several tests were conducted with ORNL’s Zircaloy-4 tube inventory to (1) develop material properties as a standard for future tests, (2) determine the effect of the US Department of Energy’s Advanced Fuels Campaign coating processes on tube mechanical properties, and (3) evaluate the effect of specimen machining methods on the mechanical properties of tube geometries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SEP solar array technology development

A technology development program is in progress to define a detail design of a lightweight 25 KW solar array for Solar Electric Propulsion (SEP) and to demonstrate technology readiness for fabrication, testing and flight of the large area solar array system. The requirements and baseline design for the 66 W/kg are discussed. The requirement for operation at 0.3 to 6.0 AU heliocentric distance presents a wide range of temperature environments as well as severe combined thermal/vacuum/UV radiation environments. The specific technology deficient areas are defined and the technology development program is presented. The program includes design and design evaluation testing on a component level followed by the fabrication and test of a developmental full-scale solar array wing. The results of the design studies and test program underway are presented. The test program covers the areas of fabrication testing, design support evaluation testing, zero-gravity array fold-up testing, full-scale array wing testing, and NDT development testing.

Elms, R. V., Jr.↗