Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal model exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Verification of global gyrokinetic simulation of low frequency mode excited by thermal plasma in spherical tokamak

A low frequency Alfven eigenmode in the ST40 spherical tokamak (ST) is found to be resonantly excited by thermal ions from global gyrokinetic GTC simulations. The analyses of phase-space resonances and wave-particle energy exchanges show that the Beta-induced Alfvén-Acoustic Eigenmode (BAAE) is primarily driven unstable by thermal ions, but is stabilized by energetic particles (EPs). When all kinetic effects are artificially suppressed, GTC simulations in the ideal magnetohydrodynamic (MHD) limit confirm the existence of the MHD eigenmode with a frequency in the BAAEs gap, as previously found by the ideal MHD code NOVA. The kinetic effects of thermal ions induce a frequency downshift compared to the stable BAAE in the MHD simulations. These results support the verification for global gyrokinetic simulations of the BAAE in the ST. However, the simulations do not explain the experimental observations of the BAAE in the ST40, possibly owing to the limitation of the collisionless gyrokinetic Monte Carlo model for the EPs.

Alfvén eigenmode↗

Transformational Solid Oxide Fuel Cell (SOFC) Technology

This project was conducted under the Co-operative Agreement No. DE-FE0027584 with the US Department Energy to developed advanced Solid Oxide Fuel Cell (SOFC) Technologies. The overall objective of this project was to advance SOFC technology at the cell and stack level to enhance cell robustness and durability, increase performance, and reduce balance-of-plant (BOP) requirements. By reducing system complexity combined with the increases in power density and efficiency, the ultimate goal of the project was to increased reliability and to reduce capital and operating costs of installed systems. The project was focused on pathways that will reduce the cost of the SOFC cell and stack, including the following areas: Robust, redox tolerant cell technology Lower cost cell manufacturing through advances in cell design, which will reduce the amount of material, energy and time used in the fabrication of SOFCs High performance, low temperature electrolyte based on improvement of established materials Innovative SOFC stack architecture which truly integrates Balance of Plant functionality into the stack level design Thermal management of the fuel cell stack for increased durability and expanded window of operation Novel stack design amenable for use in sub-MW to multi-MW-scale power plants and having low replacement cost The incorporation of balance-of-plant (BOP) equipment into the stack platform increased the economic viability of smaller scale systems. The project objectives were met by a multi-prong approach, including new cell design complemented with modifications to existing cell technology, as well as a new stack design incorporating components typically included in the BOP, such as heat exchangers, oxidizer, fuel reformers, and recycle systems. The project culminated with demonstration of a stack test validating the viability of the cell and stack improvements. A cost model was also developed to estimate costs for the advanced stack technology at high volume manufacturing levels. The net outcome of the project is SOFC cell and stack technology with costs significantly below current DOE targets without compromising and, in some cases, improving on the performance and degradation rate demonstrated with the current state-of-the-art stack design. The results of this project advanced the reliability, robustness, and endurance of low-cost SOFC technology that ultimately are ready to be deployed in coal power systems with greater than 60 percent efficiency (based on higher heating value of fuel) and the capability for ≥97% CO 2 capture at a cost-of-electricity that is approximately 40 percent below presently available Integrated Gasification Combined Cycle systems.

03 NATURAL GAS↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Ion irradiation and modification: The role of coupled electronic and nuclear energy dissipation and subsequent nonequilibrium processes in materials

Understanding material responses to energy deposition from energetic charged particles is important for defect engineering, ion-beam processing, ion-beam analysis and modification, geologic aging, space exploration, and nuclear applications. As an incident ion penetrates a solid, its energy is transferred to electrons and to atomic nuclei of the solid. Much of this electronic energy deposition is subsequently transferred to the atomic structure via electron–phonon (e–ph) coupling, leading to local inelastic thermal spikes in which energy dissipation is influenced by the local environment. In addition, intense ionization can lead to high densities of localized electronic excitations in wide-bandgap materials and ceramics that can affect defect dynamics and atomic mobility. Specifically, energy exchange between electrons and atomic nuclei, along with localized electronic excitations, can lead to substantial competitive (ionization-induced annealing), additive (both electronic and nuclear energy depositions contributing to damage production), and synergistic (more damage than the sums of separate damage processes) effects. Although nonmonotonic effects of the e–ph coupling strength and athermal processes are demonstrated for pre-existing defects and residual damage during ion–solid interactions, there is limited understanding of when such electronic effects must be considered in atomic-scale models of damage production and evolution in a broad variety of materials. Complex ceramics and chemically disordered solid solution alloys with different constituent elements allow a systematic evaluation of defect dynamics and irradiation performance with increasing complexity. Current knowledge regarding tuning of bonding characteristics and chemical disorder to control atomic-level dynamics is reviewed. Although a lack of fundamental understanding obstructs the advancement of reliable predictions for ion beam material modification, it highlights challenges and opens research opportunities. Insights into the complex electronic and atomic correlations with extreme energy deposition will strengthen our ability to design materials and predict ion-irradiation-induced damage in a radiation environment, and they may pave the way to better control fundamental processes and design new material functionalities for advanced technologies.

36 MATERIALS SCIENCE↗

Parametric and Sensitivity Analysis of a Steam Generator Model Using Python and Machine-Learning Tools

For this study, we used Python and machine-learning tools to perform a comprehensive parametric and sensitivity analysis on a steam generator (SG) model. (The Python model was based on a previously completed MATLAB framework for the Holtec SMR-160 SG.) We investigated the influence of various input parameters (e.g., heat transfer coefficient [HTC], Nusselt number, and heat exchanger effectiveness) on the system’s output. With machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN), which was developed at Idaho National Laboratory, we were then able to perform an automated analysis of the SG inputs’ effect on the HTC. The analysis results give valuable insights into the performance and optimization of SG systems. We found the inlet mass flow rate (MFR) to have the greatest impact on the HTC, followed closely by the inlet temperature, and then pressure. Shifting of the input parameters causes the location of the maximum HTC along the SG length to change incrementally. The cold leg (CL) MFR was also found to impact the HTC magnitude as well as the location of the maximum HTC. At between 0.4–0.9 of the total SG length, the input parameters experience maximum impact on the HTC, leading us to suggest that sensors be efficiently placed on the SG so as to closely and effectively monitor thermal-hydraulic properties during reactor operation. We also found that the sensitivity data calculated manually agrees with the RAVEN – based data, confirming the same range of maximum sensitivity. However, the RAVEN-based analysis showed that cold leg pressure and hot leg temperature have a greater impact on the heat transfer coefficient than the mass flow rate, implying that a manual sensitivity study taking only two samples is not accurate.

20 FOSSIL-FUELED POWER PLANTS↗

A Preliminary Investigation on the Cost Reduction Potential of Optimizing Bore Fields for Commercial Ground Source Heat Pump Systems

The high initial cost of ground heat exchangers (GHE) is a primary hurdle preventing wider adoption of ground source heat pump (GSHP) systems. GHEs used for commercial GSHP systems commonly consist of vertical boreholes installed on a grid with equal spacing between boreholes. Significant thermal loads require a large number of boreholes to be present in the field. However, due to thermal interactions among boreholes, the ground formation in the center of a bore field can, over time, become thermally saturated when the thermal load is not balanced on an annual basis. The loss of effectiveness due to thermal saturation at the center boreholes in regularly spaced borehole fields suggests that larger spacing near the center of the bore field could be more optimal, and in return reduce initial costs. Through computer simulations using the latest development of a GHE modeling tool, this study evaluates the impacts of various unconventional designs of the borehole field on the performance and cost of the GHEs of a typical commercial GSHP system. The unconventional designs include irregular spacing among boreholes with decreased spacing around the perimeter and increased spacing in the interior of the field. The unconventional bore field design shortens the total drilling length by up to 42% while giving better heat transfer performance than a conventional bore field design. The significant total bore length reduction is due to improved heat transfer effectiveness of each borehole in the unconventional bore field.

Spitler, Jeffery↗

Magnetoelastic interactions in SrCu 2 (BO 3 ) 2 studied by Raman scattering experiments and first principles calculations

Dynamic and static crystal lattice properties of SrCu 2 (BO 3 ) 2 are studied by means of Raman scattering, magnetostriction, and thermal expansion measurements in magnetic fields to 45 T. Raman experiments versus temperature reveal that some phonon modes show an unusual behavior: their frequencies soften (modes at 200 and 450 cm –1 ) while others harden (modes at 385 and 478 cm –1 ) when decreasing the temperature below 15 K. Magneto-Raman experiments show that their field dependence correlates with their respective temperature dependencies; e.g., modes that are hardened with increasing temperature also harden with applied magnetic fields and modes that become softer with temperature also soften with applied fields. We use density functional theory to successfully model and compute the energies of these modes, classifying them into two types: pantograph (modes that soften when decreasing the temperature) and nonpantograph. We conclude that the former involves the modification of the intradimer exchange interaction J and the latter the interdimer J'. Lastly, dilatometry is used to correlate field-dependent Raman modes to the closing of the spin gap as well as fractional-magnetization stripe states M = 1/4 M s and M = 1/3 M s , where M s is the saturation magnetization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Composite Structured Surfaces for Durable Dropwise Condensation

Dropwise condensation of steam on hydrophobic substrates has a 10X higher heat transfer coefficient compared to filmwise condensation. To promote dropwise condensation, low surface energy hydrophobic coatings (polymers) are typically utilized. The low intrinsic thermal conductivity (k < 1 W/(m · K)) of polymers, coupled with high heat transfer coefficient of dropwise condensation (100 kW/(m 2 · K)), necessitates that the coating be thin (< 1µm) in order to avoid reducing the overall heat exchanger conductance. However, thin polymeric films easily degrade. The two opposing requirements result in the need for optimization between the durability (thick coating) and the heat transfer (thin coating). To enable high thermal conductivity in thicker coatings, we develop metal-polymer structured surfaces. By using porous structures as inter-connected heat-conducting backbones that are filled with hydrophobic materials, we enable tuning of the coating effective thermal conductivity and surface energy. Three metal structures were studied; micro/nanowires, inverse opals, and sintered spheres. Heat transfer performance was calculated using three-dimensional finite element method simulations with two distinct boundary conditions; convection at the walls and isothermal walls. Interestingly, the overall conductance shows up to 40% difference depending on the boundary condition used in calculating the composite coating effective thermal conductivity. We use our model to predict the heat transfer performance as a function of metal fraction by volume and by surface area for condensation. By coupling our thermal simulations with a previously verified analytical model for predicting wetting behavior on heterogeneous surfaces, we propose a regime map to predict dropwise-to-filmwise transition. Furthermore, our work not only forms a starting point for the development of durable dropwise condensing surfaces, it identifies important considerations needed for computing effective thermal conductivity of composites.

42 ENGINEERING↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area: Preprint

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs drilled in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated including a single, double, and multi-lateral design. The subsurface within area is characterized by deep, hot (> 200degreesC) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lies within a target depth of 6 km where temperatures are estimated to approach 300degreesC. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down technoeconomic analysis model. The results show that the performance and cost optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60degreesC/km. By injecting 20 degreesC-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth can be achieved, resulting in an LCOE and LCOH of $136/MWh and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of silica fouling on nonwetting surfaces

Ground water sources used as coolant fluids in a variety of thermal systems such as heat exchangers and power plant condensers contain silica particles that accrete on heat transfer surfaces over time leading to reduction in thermal performance, a problem that is particularly exacerbated with temperature. Nonwetting superhydrophobic, lubricant-infused, and a new class of solid-infused surfaces introduced in this work are candidates for fouling mitigation, by virtue of their water repellency, but little is known about fouling of silica on the surfaces, especially under dynamic flow conditions and as a function of temperature. This article presents, for the first time, a systematic study of dynamic flow fouling of silica on nonwetting surfaces vis-à-vis conventional copper surface over a temperature range 20–50°C. The mechanism of silica aggregate formation and its adherence to the different surfaces is elucidated by scanning electron microscope (SEM) imaging. Sigmoidal growth model is used to describe the time evolution of fouling thermal resistance and an Arrhenius model is presented for the temperature-dependent increase in the asymptotic fouling resistance on nonwetting and conventional surfaces alike. Lubricant-infused and solid-infused surfaces are shown to reduce fouling thermal resistance by up to 25% and 13%, respectively, compared to a conventional surface, whereas superhydrophobic surfaces lose their non-wettability under flow conditions, leading to an adverse increase in the fouling resistance by up to 13%. Considering the possible lubricant depletion in lubricant-infused surfaces over prolonged exposure to a flowing fluid, solid-infused surfaces present a robust alternative.

42 ENGINEERING↗

Chromium versus Aluminum: Impact of Nickel Alloy Composition and Interfacial Kinetics on High-Temperature Passivating Oxide Formation

High-temperature corrosion resistance depends critically on the formation of a passivating surface oxide, which is highly sensitive to alloy composition and structure. Such details often elude experimental investigation, and simplified analytical models fail to provide a truly chemical view of passivating oxide evolution. Here, we explicitly compare the fundamental chemistry of Cr and Al as prototypical passivating elements in Ni alloys by directly simulating competing reaction and diffusion processes within the oxide film using kinetic Monte Carlo and density functional theory. We find that the origin and expression of passivating behavior during early-stage thermal oxidation are qualitatively different between the two alloy systems. Ni–Cr alloys feature a sudden onset of passivation associated with a sharp phase transition upon Cr enrichment that directly couples oxidation kinetics to phase transformation behavior. In contrast, Ni–Al alloys display more continuous oxide phase variation with Al enrichment, ultimately resulting in a lower composition threshold for passivation and a thinner passivating layer. In addition, we elucidate the nonobvious role of metal exchange within the alloy near the oxide boundary, which fundamentally alters film composition and passivating behavior. Furthermore, our results have key implications for engineering improved corrosion-resistant alloys, both in terms of compositional variation and processing.

Alloys↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated, including a single-, double-, and multi-lateral design. The subsurface within the area of interest is characterized by deep, hot (> 200 degrees C) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lie(s) within a target depth of 6 km, where temperatures are estimated to approach 300 degrees C. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot, dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down techno-economic analysis model. The results show that the performance- and cost-optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60 degrees C/km. By injecting 20 degrees C-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth (i.e., 2.2 MWe net plant output) can be achieved, resulting in an LCOE and LCOH of $136/MWhe and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

The heat transfer coefficient associated with a moving packed bed of silica particles flowing through parallel plates

Concentrating Solar Power (CSP) with thermal energy storage has the potential to be a renewable energy technology with long duration, inexpensive energy storage. Higher temperature operation increases the conversion efficiency and reduces the cost of energy storage. Several emerging CSP designs utilize particles as the solar receiver due to their high temperature stability and low cost. In some designs, the particles are also used as the thermal energy storage (TES) media. In either configuration, an energy transfer is required between the hot particles and the working fluid in the power cycle in a Particle-to-Fluid Heat Exchanger (PtFHX). Understanding the heat transfer between a moving packed bed and a stationary surface is critical to the successful design of a PtFHX. In this paper, a test facility is described in which a moving packed bed of silica sand with particle size 100–600 μm is introduced into the channel formed by two parallel plates, one of which is heated. The effective static thermal conductivity of the particles used for the test are separately measured over the entire range of test temperatures. The inlet and outlet bulk temperatures of the particle flow are measured as are the surface temperatures at several axial locations along the centerline of the plate. The result is the measurement of heat transfer coefficient as a function of temperature for several velocities. The uncertainty of the measurements is presented and the results are compared to model results found in the literature.

14 SOLAR ENERGY↗

Report on Initial Sodium Testing on the Thermal Hydraulic Experimental Test Article (THETA) (Fiscal Year 2024 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as to acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal thermal hydraulic conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. In fiscal year 2023, thermal stratification tests were completed with the primary system online, while the secondary system was being constructed [1]. These tests had shown that the core barrel and intermediate heat exchanger (IHX) outlet required increased thermal insulation. The THETA primary system was removed from METL, cleaned, thermal insulators installed, and then inserted into METL Test Vessel 4. At the time of this writing the THETA primary and secondary system are operational. During this fiscal year 100+ hours of testing was completed to characterize thermal hydraulic phenomena associated with steady state and transient conditions in a pool type liquid metal cooled reactor. A majority of the testing campaign was completed to satisfy the experimental data acquisition requirements for the GAIN Voucher with Oklo, CRADA 2021-21121. THETA is still operational at the time of this publication and future testing is planned for fiscal year 2025. Work is underway to publish existing and future data to an online database to facilitate collaboration with SFR engineers looking to validate their systems code or computational fluid dynamics models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A reduced-order modeling of a tubular solar reactor for long duration thermochemical energy storage

The storage of solar energy in a solid form, referred to as a “solar fuel”, can be achieved through a process known as endothermic solar thermochemistry. This process transforms the absorbed solar energy into a stable and retrievable form that can be stored for extended periods of time. This paper presents a low–order heat transfer model of a counter–current tubular falling bed reactor designed to produce thermally reduced magnesium manganese oxide pellets for long duration thermochemical energy storage. The energy required for the endothermic reduction was supplied by concentrated solar energy or renewable electricity via indirect heating of the gas and solid reactants flowing in a ceramic tube. The counter-current gas flow enhances the mixing of the solid particles with the heat recuperation zone, allowing the gas and particles to enter and exit the tubular reactor close to room temperature. Further, the reactor was vertically oriented and was heated circumferentially by an adjustable level heat flux along a finite segment of its length. The temperature distribution of the reactor in response to transient changes along the tube was modeled by considering conduction, convection, and radiation heat transfer. Governing equations for the heat transfer model were solved by discretizing the reactor tube into a finite number of control volumes and using an energy balance for the heat exchange between the reactor wall, gas, and particles within the control volume. The energy absorbed during this endothermic reaction was modeled numerically by fitting the data of the chemical conversion rate with the corresponding temperature of particles in the heating zone. The numerical model has been experimentally validated using a reactor prototype made of a 121.92 cm alumina tube heated by a 7kW electric tube–furnace. The alumina tube receives magnesium manganese oxide pellets of 3.66±0.516 mm in diameter from the top, and a counter–current gas flow from the bottom. The reactor wall temperature was monitored by six thermocouples installed along the reactor tube length. The experimental procedure was numerically simulated, and the temperature variation along the reactor tube was compared with a matrix of experimental runs for a range of particles mass flowrates (0.75–1.25g/s) and corresponding gas flowrates (36–65 SLPM). The reactor system was heated gradually from room temperature to a steady state temperature of 1673K, and then cooled down to room temperature. The heating and cooling processes were simulated, and the numerical and experimental results were compared throughout processes. The numerical model showed similar trends to the experimental results, with an error of 0.69 to 7.9% for the particle inlet and 0.7 to 7.9% for the gas inlet during steady-state operation. The proposed numerical model can be implemented as a simplified physical model to design a feedback control system to regulate reactor temperature.

14 SOLAR ENERGY↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗