Cracking of a layered medium on an elastic foundation under thermal shock

The cladded pressure vessel under thermal shock conditions which is simulated by using two simpler models was studied. The first model (Model 1) assumes that, if the crack size is very small compared to the vessel thickness, the problem can be treated as a semi-infinite elastic medium bonded to a very thin layer of different material. However, if the crack size is of the same order as the vessel thickness, the curvature effects may not be negligible. In this case it is assumed that the relatively thin walled hollow cylinder with cladding can be treated as a composite beam on an elastic foundation (Model 2). In both models, the effect of surface cooling rate is studied by assuming the temperature boundary condition to be a ramp function. The calculated results include the transient temperature, thermal stresses in the uncracked medium and stress intensity factors which are presented as a function of time, and the duration of cooling ramp. The stress intensity factors are also presented as a function of the size and the location of the crack. The problem is solved for two bonded materials of different thermal and mechanical properties. The mathematical formulation results in two singular integral equations which are solved numerically. The results are given for two material pairs, namely an austenitic steel layer welded on a ferritic steel substrate, and a ceramic coating on ferritic steel. In the case of the yielded clad, the stress intensity factors for a crack under the clad are determined by using a plastic strip model and are compared with elastic clad results.

Rizk, Abd El-Fattah A.↗

Preliminary Thermal Stress Analysis of a High-Pressure Cryogenic Storage Tank

The thermal stresses on a cryogenic storage tank strongly affect the condition of the tank and its ability to withstand operational stresses. These thermal stresses also affect the growth of any surface damage that might occur in the tank walls. These stresses are particularly of concern during the initial cooldown period for a new tank placed into service, and during any subsequent thermal cycles. A preliminary thermal stress analysis of a high-pressure cryogenic storage tank was performed. Stresses during normal operation were determined, as well as the transient temperature distribution. An elastic analysis was used to determine the thermal stresses in the inner wall based on the temperature data. The results of this elastic analysis indicate that the inner wall of the storage tank will experience thermal stresses of approximately 145,000 psi (1000 MPa). This stress level is well above the room-temperature yield strength of 304L stainless steel, which is about 25,000 psi (170 MPa). For this preliminary analysis, several important factors have not yet been considered. These factors include increased strength of 304L stainless steel at cryogenic temperatures, plastic material behavior, and increased strength due to strain hardening. In order to more accurately determine the thermal stresses and their affect on the tank material, further investigation is required, particularly in the area of material properties and their relationship to stress.

Baker, J. Mark↗

Melting relations in the iron-sulfur system at ultra-high pressures - Implications for the thermal state of the earth

The melting temperatures of FeS-troilite and of a 10-wt-pct sulfur iron alloy have been measured to pressures of 120 and 90 GPa, respectively. The results document that FeS melts at a temperature of 4100 (+ or - 300) K at the pressure of the core-mantle boundary. Eutecticlike behavior persists in the iron-sulfur system to the highest pressures of measurements, in marked contrast to the solid-solutionlike behavior observed at high pressures in the iron-iron oxide system. Iron with 10-wt-pct sulfur melts at a similar temperature as FeS at core-mantle boundary conditions. If the sole alloying elements of iron within the core are sulfur and oxygen and the outer core is entirely liquid, the minimum temperature at the top of the outer core is 4900 (+ or - 400) K. Calculations of mantle geotherms dictate that there must be a temperature increase of between 1000 and 2000 K across thermal boundary layers within the mantle. If D-double-prime is compositionally stratified, it could accommodate the bulk of this temperature jump.

Williams, Quentin↗

Exploration Extravehicular Mobility Unit (xEMU) Chamber B Thermal Vacuum “Suit 2” Pressure Garment System Test Article Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test results from the “Suit 2” Pressure Garment System (PGS) test article. The primary objective of the “Suit 2” PGS test article was to evaluate system-level suit heat leak and Environmental Protection Garment (EPG) thermal performance. Eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and a heater cage surrounding the test article. This paper will principally focus on system-level thermal results from the “Suit 2” PGS test article. This paper will examine data collected from one-hundred and seventy thermocouples located in critical locations inside and outside of the suit, as well as seven resistance thermometers (RTDs) for calorimetry to determine total heat flux in and out of the suit. The test data will be compared against the system-level PGS thermal models for model validation. To conclude, this paper will address knowledge gaps presented by unmanned xPGS thermal vacuum testing and the current state of lunar xPGS thermal modeling and testing.

xEMU↗

Exploration Extravehicular Mobility Unit (xEMU) Chamber B Thermal Vacuum “Suit 2” Pressure Garment System Hardware and Test Design

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation space suit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test hardware design and test methodology for the “Suit 2” Pressure Garment System (PGS) test article. The uncrewed “Suit 2” PGS test article consisted of a full PGS assembly with simulated Portable Life Support System (PLSS) functionality provided by test equipment, including a ventilation loop and two distinct thermal control loops. This paper will discuss in depth the test hardware design, including internal suit thermal boundary simulation, sensor quantity and placement, test support equipment rigs for gas flow, water flow, and power. Custom hardware designed to add additional penetrations to the suit or provide additional interfaces for sensors will also be discussed. This paper will also address the assembly and integration sequence for the test article. In addition to test hardware design, this paper will provide insights into the test methodology for this test article, including a discussion of thermal steady-state testing, simultaneous dual suit thermal vacuum testing, and hazard mitigation and controls.

xEMU↗

A detailed X-ray and radio comparison of Kepler's supernova remnant

High-resolution radio images of Kepler's SNR (SNR (SN 1604) at 6 and 21 cm have been obtained using the VLA. The orientation of linear polarization in the SNR implies a substantial nonrandom radial component for the magnetic field of the remnant. Based on a new X-ray picture of the SNR, obtained using the Einstein Observatory, a detailed comparison of the X-ray and radio morphology is carried out. There is a good correlation between rotation measure, obtained from the radio maps, and emission measure, an X-ray-derived quantity in the SNR shell. From the mean electron density value infered from an analysis of X-ray fluxes, a mean radial magnetic field of 14 micro G and a total magnetic field of 70 microG are estimated. The energy density of relativistic electrons in Kepler's SNR in the shell comparable to the energy density in the magnetic field; the relativistic electron-pressure is 2 percent of the thermal gas pressure. The strong correlation between radio emissivity and X-ray emissivity found over the SNR in somewhat large scale can be ascribed to acceleration of thermal electrons at the shock wave and insignificant diffusion of resultant relativistic electrons.

Matsui, Y.↗

Potential pressurized payloads: Fluid and thermal experiments

Space Station Freedom (SSF) presents the opportunity to perform long term fluid and thermal experiments in a microgravity environment. This presentation provides perspective on the need for fluids/thermal experimentation in a microgravity environment, addresses previous efforts, identifies possible experiments, and discusses the capabilities of a proposed fluid physics/dynamics test facility. Numerous spacecraft systems use fluids for their operation. Thermal control, propulsion, waste management, and various operational processes are examples of such systems. However, effective ground testing is very difficult. This is because the effect of gravity induced phenomena, such as hydrostatic pressure, buoyant convection, and stratification, overcome such forces as surface tension, diffusion, electric potential, etc., which normally dominate in a microgravity environment. Hence, space experimentation is necessary to develop and validate a new fluid based technology. Two broad types of experiments may be performed on SSF: basic research and applied research. Basic research might include experiments focusing on capillary phenomena (with or without thermal and/or solutal gradients), thermal/solutal convection, phase transitions, and multiphase flow. Representative examples of applied research might include two-phase pressure drop, two-phase flow instabilities, heat transfer coefficients, fluid tank fill/drain, tank slosh dynamics, condensate removal enhancement, and void formation within thermal energy storage materials. In order to better support such fluid/thermal experiments on board SSF, OSSA has developed a conceptual design for a proposed Fluid Physics/Dynamics Facility (FP/DF). The proposed facility consists of one facility rack permanently located on SSF and one experimenter rack which is changed out as needed to support specific experiments. This approach will minimize the on-board integration/deintegration required for specific experiments. The FP/DF will have acceleration/vibration compensation, power and thermal interfaces, computer command/data collection, a video imaging system, and a portable glove box for operations. This facility will allow real-time astronaut interaction with the testing.

Swanson, Theodore D.↗

Comparative techno-economic assessment of osmotically-assisted reverse osmosis and batch-operated vacuum-air-gap membrane distillation for high-salinity water desalination

New developments in pressure- and thermally driven membrane desalination technologies offer the potential to cost-effectively treat high-salinity waters, especially when powered by low-cost solar electricity and thermal energy. This paper presents a comparative techno-economic assessment of the state-of-the-art most promising pressure- and thermally driven membrane technologies for high recovery desalination, namely, osmotically-assisted reverse osmosis (OARO) and batch-operated vacuum-air-gap membrane distillation (batch V-AGMD), to produce potable water while concentrating brine within the range of 140–290 g/L TDS for minimum-liquid-discharge (MLD) and zero-liquid-discharge (ZLD) applications. It is shown that both OARO and batch V-AGMD can treat feedwater and brines with TDS in the range of 30–125 g/L with corresponding fresh water recovery rates of 85–25%. When low cost solar electricity and thermal energy are used, the resulting levelized cost of water (LCOW) from OARO is in the range of 0.70–6.28 $/m 3 , and that from batch-V-AGMD is in the range of 1.74–2.77 $/m 3 . OARO is more cost-effective than batch V-AGMD when feedwater salinity is below 70 g/L and recovery below 75%, whereas batch V-AGMD is more cost-effective at higher recovery rates and salinity levels. Finally, the sensitivity of this comparison on energy prices and module costs is discussed.

42 ENGINEERING↗

Ramp compression of tantalum to multiterapascal pressures: Constraints of the thermal equation of state to 2.3 TPa and 5000 K

We report measurements of the compressibility of ramp compressed tantalum to a final stress of 2.3 TPa corresponding to threefold volumetric compression. Using these data, we extended the experimental constraint on the Ta cold compression curve by an order of magnitude in pressure. Furthermore, by combining the resulting data with previous measurements of shock compression and ambient pressure heating, we construct an experimentally bounded and thermodynamically consistent equation of state model for Ta which has 2% uncertainty in pressure at 1 TPa. We therefore propose Ta as an in situ pressure scale for laser-heated static compression experiments which were recently able to reach terapascal pressures and thousands of degrees Kelvin. Our new equation of state of Ta is experimentally constrained at extreme pressures and temperatures relevant to a wide range of planetary interiors and will allow for more accurate comparison between experimental measurements and theory at extreme conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic Pressure Drag on Rising Buoyant Thermals in a Neutrally Stable Environment

Abstract This study examines dynamic pressure drag on rising dry buoyant thermals. A theoretical expression for drag coefficient C d as a function of several other nondimensional parameters governing thermal dynamics is derived based on combining the thermal momentum budget with the similarity theory of Scorer. Using values for these nondimensional parameters from previous studies, the theory suggests drag on thermals is small relative to that on solid spheres in laminar or turbulent flow. Two sets of numerical simulations of thermals in an unstratified, neutrally stable environment using an LES configuration of the Cloud Model 1 (CM1) are analyzed. One set has a relatively low effective Reynolds number R e and the other has an order-of-magnitude-higher R e ; these produce laminar and turbulent resolved-scale flows, respectively. Consistent with the theoretical C d , the magnitude of drag is small in all simulations. However, whereas the laminar thermals have C d ≈ 0.01, the turbulent thermals have weakly negative drag ( C d ≈ −0.1). This difference is explained by the laminar thermals having near vertical symmetry but the turbulent thermals exhibiting considerable vertical asymmetry of their azimuthally averaged flows. In the laminar thermals, buoyancy rapidly becomes concentrated around the main centers of rotation located along the horizontal central axis, leading to expansion of thermals via baroclinic vorticity generation but doing little to break vertical symmetry of the flow. Vertical asymmetry of the azimuthally averaged flow of turbulent thermals is attributed mainly to small-scale resolved eddies that are concentrated in the upper part of the thermals.

Meteorology & Atmospheric Sciences↗

Proton Collective Quantum Tunneling Induces Anomalous Thermal Conductivity of Ice under Pressure

Proton tunneling is believed to be nonlocal in ice, but its range has been shown to be limited to only a few molecules. Here, we measured the thermal conductivity of ice under pressure up to 50 GPa and found it increases with pressure until 20 GPa but decreases at higher pressures. We attribute this nonmonotonic thermal conductivity to the collective tunneling of protons at high pressures, supported by large-scale quantum molecular dynamics simulations. The collective tunneling loops span several picoseconds in time and are as large as nanometers in space, which match the phonon periods and wavelengths, leading to strong phonon scattering at high pressures. Finally, our results show direct evidence of global quantum motion existing in high-pressure ice and provide a new perspective to understanding the coupling between phonon propagation and atomic tunneling.

36 MATERIALS SCIENCE↗

Effect of Pressure in Thermoplastic Ribbon Thermal Welding

An inexpensive apparatus was designed to simulate some features of on-the-fly thermal welding in heated-head tow placement. Previous studies have shown how ply/ply weld strength depends on weld time/temperature history. The apparatus has been modified recently to apply higher contact forces. Welding at pressures up to 1.7MPa (250psi) produced more consistent welds and fewer intra-ply voids, This has permitted a study of the conditions required for achieving the limiting ply/ply cohesive strength in simulated tow placement of a polyimide oligomer.

Hinkley, J. A.↗

Ambient Pressure XPS Investigation of Thermally Stable Halide Perovskite Solar Cells via Post-Treatment

Long-term thermal stability is one limiting factor that impedes the commercialization of perovskite solar cell. Inspired by our prior results from machine learning, we discover that coating a thin layer of 4,4’-dibromotriphenylamine (DBTPA) on top of a CH 3 NH 3 PbI 3 (MAPbI 3 ) thin film can improve the stability of the resultant perovskite solar cells. The passivated perovskite solar cells retained more than 96% of their initial power conversion efficiency over 1000 h at 85 °C in N2 atmosphere without encapsulation. Near-ambient pressure x-ray photoelectron spectroscopy (NAP-XPS) was employed to investigate the evolution of composition and evaluate thermal and moisture stability by in-situ studies. A comparison between pristine MAPbI 3 films and DBTPA-treated films shows the DBTPA treatment suppresses the escape of iodide and methylamine up to 150 °C under 5 mbar humidity. Furthermore, we have used ATR-FTIR and XPS to probe the interactions between DBTPA and MAPbI3 surface. The results prove that DBTPA coordinate with perovskite by Lewis acid-base and cation-π interaction. Compared with the 19.9% efficiency of pristine sample, the champion efficiency of passivated sample reaches 20.6%. Finally, our results reveal DBTPA as a new post-treating molecule that not only leads to the improvement of photovoltaic efficiency but also thermal and moisture stability.

14 SOLAR ENERGY↗

Structural and preliminary thermal performance testing of a pressure activated contact heat exchanger

A contact heat exchanger concept is being developed for use onboard Space Station as an interface device between external thermal bus and pressurized modules. The concept relies on mechanical contact activated by the fluid pressure inside thin-walled tubes. Structural testings were carried out to confirm the technology feasibility of using such thin-walled tubes. The test results also verified the linear elastic stress analysis which was used to predict the tube mechanical behaviors. A preliminary thermal testing was also performed with liquid Freon-11 flowing inside tubes and heat being supplied by electrical heating from the bottom of the contact heat exchanger baseplate. The test results showed excellent agreement of test data with analytical prediction for all thermal resistances except for the two-phase flow characteristics. Testing with two-phase flow inside tubes will, however, be performed on the NASA-JSC test bed.

Lee, C. Y.↗

Audible Noise Modeling of Hydrogen Release Sonic Hazards in Rail Maintenance Facilities

This study implemented validated literature models to predict audible noise due to pressurized gaseous hydrogen releases through a thermally-activated pressure relief device (TPRD) and attached vent stack. A literature survey discovered limited hydrogen-specific noise prediction models validated by experiments. However, empirical noise prediction models for air flowing through pipes and valves were identified. These empirical models were used to predict noise levels and compared against hydrogen noise data reported in two studies: one experimental study of noise from hydrogen leaking through a pipe and another which modeled hydrogen flowing through a solenoid valve during a fuel cell vehicle refueling. The valve flow model was then applied to predict noise for hydrogen releases through a TPRD. Results show that hydrogen releases through a TPRD can produce harmful noise levels varying from 134 to 150 dB. However, further model validation and additional experimental data are needed to improve prediction confidence and accuracy.

08 HYDROGEN↗

Elastic-Plastic Thermal Stress Analysis of a High-Pressure Cryogenic Storage Tank

The thermal stresses on a cryogenic storage tank contribute strongly to the state of stress of the tank material and its ability to withstand operational stresses. These thermal stresses also affect the growth of any surface damage that might occur in the tank walls. These stresses are particularly of concern during the initial cooldown period for a new tank placed into service, and during any subsequent thermal cycles. A previous preliminary elastic analysis showed that the thermal stress on the inner wall would reach approximately 1,000MPa (145,000 psi). This stress far exceeds the ASTM specified room temperature values for both yield (170MPa) and ultimate (485 MPa) strength for 304L stainless steel. The present analysis determines the thermal stresses using an elastic-plastic model. The commercial software application ANSYS was used to determine the transient spatial temperature profile and the associated spatial thermal stress profiles in a segment of a thick-walled vessel during a typical cooldown process. A strictly elastic analysis using standard material properties for 304L stainless steel showed that the maximum thermal stress on the inner and outer walls was approximately 960 MPa (tensile) and - 270 MPa (compressive) respectively. These values occurred early in the cooldown process, but at different times, An elastic-plastic analysis showed significantly reducing stress, as expected due to the plastic deformation of the material. The maximum stress for the inner wall was approximately 225 MPa (tensile), while the maximum stress for the outer wall was approximately - 130 MPa (compressive).

Barker, J. Mark↗

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.

xEMU↗