Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Optical Links and RF Distribution for Antenna Arrays

An array of three antennas has recently been developed at the NASA Jet Propulsion Laboratory capable of detecting signals at X and Ka band. The array requires a common frequency reference and high precision phase alignment to correlate received signals. Frequency and timing references are presently provided from a remotely located hydrogen maser and clock through a combination of commercially and custom developed optical links. The selected laser, photodetector, and fiber components have been tested under anticipated thermal and simulated antenna rotation conditions. The resulting stability limitations due to thermal perturbations or induced stress on the optical fiber have been characterized. Distribution of the X band local oscillator includes a loop back and precision phase monitor to enable correlation of signals received from each antenna.

antenna array↗

Multidimensional Tests of Thermal Protection Materials in the Arcjet Test Facility

Many thermal protection system materials used for spacecraft heatshields have anisotropic thermal properties, causing them to display significantly different thermal characteristics in different directions, when subjected to a heating environment during flight or arcjet tests. This paper investigates the effects of sidewall heating coupled with anisotropic thermal properties of thermal protection materials in the arcjet environment. Phenolic Impregnated Carbon Ablator (PICA) and LI-2200 materials (the insulation material of Shuttle tiles) were used for this study. First, conduction-based thermal response simulations were carried out, using the Marc.Mentat finite element solver, to study the effects of sidewall heating on PICA arcjet coupons. The simulation showed that sidewall heating plays a significant role in thermal response of these models. Arcjet tests at the Aerodynamic Heating Facility (AHF) at NASA Ames Research Center were performed later on instrumented coupons to obtain temperature history at sidewall and various radial locations. The details of instrumentation and experimental technique are the prime focus of this paper. The results obtained from testing confirmed that sidewall heating plays a significant role in thermal response of these models. The test results were later used to verify the two-dimensional ablation, thermal response, and sizing program, TITAN. The test data and model predictions were found to be in excellent agreement

Agrawal, Parul↗

Multidimensional Testing of Thermal Protection Materials in the Arcjet Test Facility

Many thermal protection system materials used for spacecraft heatshields have anisotropic thermal properties, causing them to display significantly different thermal characteristics in different directions, when subjected to a heating environment during flight or arcjet tests. The anisotropic effects are enhanced in the presence of sidewall heating. This paper investigates the effects of anisotropic thermal properties of thermal protection materials coupled with sidewall heating in the arcjet environment. Phenolic Impregnated Carbon Ablator (PICA) and LI-2200 materials (the insulation material of Shuttle tiles) were used for this study. First, conduction-based thermal response simulations were carried out, using the Marc.Mentat finite element solver, to study the effects of sidewall heating on PICA arcjet coupons. The simulation showed that sidewall heating plays a significant role in thermal response of these models. Arcjet tests at the Aerodynamic Heating Facility (AHF) at NASA Ames Research Center were performed later on instrumented coupons to obtain temperature history at sidewall and various radial locations. The details of instrumentation and experimental technique are the prime focus of this paper. The results obtained from testing confirmed that sidewall heating plays a significant role in thermal response of these models. The test results were later used to validate the two-dimensional ablation, thermal response, and sizing program, TITAN. The test data and model predictions were found to be in excellent agreement

Agrawal, Parul↗

Performance and economic risk evaluation of dispersed solar thermal power systems by Monte Carlo simulation

A preliminary comparative evaluation of dispersed solar thermal power plants utilizing advanced technologies available in 1985-2000 time frame is under way at JPL. The solar power plants of 50 KWe to 10 MWe size are equipped with two axis tracking parabolic dish concentrator systems operating at temperatures in excess of 1000 F. The energy conversion schemes under consideration include advanced steam, open and closed cycle gas turbines, stirling, and combined cycle. The energy storage systems include advanced batteries, liquid metal, and chemical. This paper outlines a simple methodology for a probabilistic assessment of such systems. Sources of uncertainty in the development of advanced systems are identified, and a computer Monte Carlo simulation is exercised to permit an analysis of the tradeoffs of the risk of failure versus the potential for large gains. Frequency distribution of energy cost for several alternatives are presented.

Manvi, R.↗

Thermo-Chemical Convection in Europa's Icy Shell with Salinity

Europa's icy surface displays numerous pits, uplifts, and chaos terrains that have been suggested to result from solid-state thermal convection in the ice shell, perhaps aided by partial melting. However, numerical simulations of thermal convection show that plumes have insufficient buoyancy to produce surface deformation. Here we present numerical simulations of thermochemical convection to test the hypothesis that convection with salinity can produce Europa's pits and domes. Our simulations show that domes (200-300 m) and pits (300-400 m) comparable to the observations can be produced in an ice shell of 15 km thick with 5-10% compositional density variation if the maximum viscosity is less than 10(exp 18) Pa sec. Additional information is included in the original extended abstract.

Han, L.↗

Techniques for hot structures testing

Hot structures testing have been going on since the early 1960's beginning with the Mach 6, X-15 airplane. Early hot structures test programs at NASA-Ames-Dryden focused on operational testing required to support the X-15 flight test program, and early hot structures research projects focused on developing lab test techniques to simulate flight thermal profiles. More recent efforts involved numerous large and small hot structures test programs that served to develop test methods and measurement techniques to provide data that promoted the correlation of test data with results from analytical codes. In Nov. 1988 a workshop was sponsored that focused on the correlation of hot structures test data with analysis. Limited material is drawn from the workshop and a more formal documentation is provided of topics that focus on hot structures test techniques used at NASA-Ames-Dryden. Topics covered include the data acquisition and control of testing, the quartz lamp heater systems, current strain and temperature sensors, and hot structures test techniques used to simulate the flight thermal environment in the lab.

Deangelis, V. Michael↗

A radiant heating test facility for space shuttle orbiter thermal protection system certification

A large scale radiant heating test facility was constructed so that thermal certification tests can be performed on the new generation of thermal protection systems developed for the space shuttle orbiter. This facility simulates surface thermal gradients, onorbit cold-soak temperatures down to 200 K, entry heating temperatures to 1710 K in an oxidizing environment, and the dynamic entry pressure environment. The capabilities of the facility and the development of new test equipment are presented.

Sherborne, W. D.↗

Measurement of transient strain and surface temperature on simulated turbine blades using noncontacting techniques

Noncontacting techniques were used to measure strain and temperature in thermally cycled simulated turbine blades. An electro-optical extensometer was used to measure the displacement between parallel targets mounted on the leading edge of the blades throughout a complete heating and cooling cycle. An infrared photographic pyrometry method was used to measure blade steady state surface temperature. The blade was cyclically heated and cooled by moving it into and out of a Mach 1 hot-gas stream. Transient leading edge strain and steady state surface temperature distributions are presented for blades of three different configurations.

Calfo, F. D.↗

Simulation of Hydrogen Flow in a Nuclear-Thermal Propulsion Reactor Subsystem: Conjugate Heat Transfer in Surrogate Fuel Elements and Flow Through the Dome Inlet to the Fuel Elements

NASA is performing research related to a Nuclear-Thermal Propulsion (NTP) engine as a step toward future manned missions to Mars. BWX Technologies (BWXT), in conjunction with NASA, is developing the reactor subsystem for that NTP engine design. As a subset of the reactor subsystem, the fuel elements have continued to evolve in design, as well. A set of experiments within the Nuclear Thermal Reactor Element Environmental Simulator at NASA Marshall has been developed to compliment that design process, including a series of surrogate fuel elements. Before the experiments of each surrogate can be completed, they must be deemed safe using structural analysis, which itself requires thermal and conjugate heat transfer analyses of the articles. Therefore, conjugate heat transfer simulations of the hydrogen flow through the test article fuel element surrogates were developed to provide estimates of heating, as well as to provide assessments of the fluid flow through the elements. The set of simulations involved not only the separate test conditions, but also a sensitivity study to estimate the effect of physical parameter uncertainty on the selected quantities of interest. Additionally, the fluid flow through the fore section inner plenum dome to the entrances of the fuel elements, another section of the reactor subsystem still under active development, was simulated and analyzed. The simulations show the extent of non-uniformity in the mass flow distribution across the dome outlets. Furthermore, additional analyses estimate the effects of required flow blockages on the potential development of flow dynamics. These analyses were used in the design cycle to make improvements to the reactor subsystem design.

Kalen E. Braman↗

Evaluation of flat-plate collector efficiency under controlled conditions in a solar simulator

The measured thermal efficiencies of 35 collectors tested with a solar simulator, along with the correlation equations used to generalize the data, are presented. The single correlation used is shown to apply to all the different types of collectors tested, including one with black paint and one cover, one with a selective surface coating and two covers, and an evacuated-tube collector. The test and correlation technique is also modified by using a shield so that collectors larger than the simulator test area can also be tested. This technique was verified experimentally for a shielded collector for which the collector shielded area was 31% of the solar simulator radiation area. A table lists all the collectors tested, the collector areas, and the experimental constants used to correlate the data for each collector.

Johnson, S. M.↗

Evaluation of flat-plate collector efficiency under controlled conditions in a solar simulator

The measured thermal efficiencies of 35 collectors tested with a solar simulator, along with the correlation equations used to generalize the data, are presented in this report. The single correlation used is shown to apply to all the different types of collectors tested, including one with black paint and one cover, one with a selective surface coating and two covers, and an evacuated-tube collector. The test and correlation technique is also modified by using a shield so that collectors larger than the simulator test area can also be tested. This technique was verified experimentally for a shielded collector for which the collector shielded area was 31% of the solar simulator radiation area. A table lists all the collectors tested, the collector areas, and the experimental constants used to correlate the data for each collector.

Johnson, S. M.↗

G-189A analytical simulation of the integrated waste management-water system using radioisotopes for thermal energy

An analytical simulation of the RITE-Integrated Waste Management and Water Recovery System using radioisotopes for thermal energy was prepared for the NASA-Manned Space Flight Center (MSFC). The RITE system is the most advanced concept water-waste management system currently under development and has undergone extended duration testing. It has the capability of disposing of nearly all spacecraft wastes including feces and trash and of recovering water from usual waste water sources: urine, condensate, wash water, etc. All of the process heat normally used in the system is produced from low penalty radioisotope heat sources. The analytical simulation was developed with the G189A computer program. The objective of the simulation was to obtain an analytical simulation which can be used to (1) evaluate the current RITE system steady state and transient performance during normal operating conditions, and also during off normal operating conditions including failure modes; and (2) evaluate the effects of variations in component design parameters and vehicle interface parameters on system performance.

Coggi, J. V.↗

Functional and dynamics testing of the flexible solar array for the communications technology satellite

The test objectives, test methods, thermal environmental simulations, and test results are described, for a series of combined dynamic, thermal, and vacuum environmental tests on a Deployable Solar Array for the Communications Technology Satellite. Six major resonant structural modes were observed over an excitation range of 0.1-1.0 Hz. Corresponding modal damping factors were found to be between 0.001 and 0.01. Variation of temperature environments between -125 C and 42 C did not significantly affect the characteristics of the fundamental modes, but did influence some of the higher modes. Superharmonic response behavior was observed. The tests also verified functional mechanical performance of the solar array under thermal and vacuum conditions.

Harrison, T. D.↗

Results of accelerated thermal cycle tests of solar cells modules

Various candidate solar panel designs were evaluated, both theoretically and experimentally, with respect to their thermal cycling survival capability, and in particular with respect to an accelerated simulation of thermal cycles representative of Viking '75 mission requirements. The experimental results were obtained on 'mini-panels' thermally cycled in a newly installed automated test facility herein described. The resulting damage was analyzed physically and theoretically, and on the basis of these analyses the panel design was suitably modified to significantly improve its ability to withstand the thermal environment. These successful modifications demonstrate the value of the complementary theoretical-experimental approach adopted, and discussed in detail in this paper.

Berman, P.↗

Development of improved high pressure turbine outer gas path seal components

A plasma sprayed graded layered ceramic/metallic (ZrO2/CoCrAlY) seal was evaluated for JT9D turbine application by rig and engine tests. Four cyclic thermal shock rig tests were conducted during the program. Three completed 1000 simulated engine thermal cycle tests and the fourth completed 500 cycles without severe cracking or spalling. Three ceramic seals were installed in a JT9D experimental engine to evaluate the effect of the engine thermal environment on the seals. All three seals completed the test successfully without severe cracking or spalling. The three seals did have slight laminar cracks at the 85/15-40/60 ZrO2/CoCrAlY interface. The second engine test evaluated the rub capabilities of the seal. Six ceramic seals were installed in the engine with fourteen abrasive tip blades. Three of the six seals rubbed to a depth of 24 mils. Eight of the fourteen abrasive tip blades showed evidence of wear. Three of the eight blades wore a maximum of five mils. Engine rub test results demonstrated the potential of reducing turbine clearances and thereby improving engine performance by use of sprayed ceramic seals.

Shiembob, L. T.↗

Orbiter integrated active thermal control subsystem test

Integrated subsystem level testing of the systems within the orbiter active thermal chamber capable of simulating ground, orbital, and entry temperature and pressure profiles. The test article was in a closed loop configuration that included flight type and functionally simulated protions of all ATCS components for collecting, transporting, and rejecting orbiter waste heat. Specially designed independently operating equipment simulated the transient thermal input from the cabin, payload, fuel cells, freon cold plates, hydraulic system, and space environment. Test team members using data, controls, and procedures available to a flight crew controlled the operation of the ATCS. The ATCS performance met or exceeded all thermal and operational requirements for planned and contingency mission support.

Jaax, J. R.↗

Thermal Vacuum Facility for Testing Thermal Protection Systems

A thermal vacuum facility for testing launch vehicle thermal protection systems by subjecting them to transient thermal conditions simulating re-entry aerodynamic heating is described. Re-entry heating is simulated by controlling the test specimen surface temperature and the environmental pressure in the chamber. Design requirements for simulating re-entry conditions are briefly described. A description of the thermal vacuum facility, the quartz lamp array and the control system is provided. The facility was evaluated by subjecting an 18 by 36 in. Inconel honeycomb panel to a typical re-entry pressure and surface temperature profile. For most of the test duration, the average difference between the measured and desired pressures was 1.6% of reading with a standard deviation of +/- 7.4%, while the average difference between measured and desired temperatures was 7.6% of reading with a standard deviation of +/- 6.5%. The temperature non-uniformity across the panel was 12% during the initial heating phase (t less than 500 sec.), and less than 2% during the remainder of the test.

Daryabeigi, Kamran↗