Search NASA⌕ Search

SEARCH · Search NASA

Results for “threshold based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

SU-E-J-219: A Dixon Based Pseudo-CT Generation Method for MR-Only Radiotherapy Treatment Planning of the Pelvis and Head and Neck

Purpose: To develop an image processing method for MRI-based generation of electron density maps, known as pseudo-CT (pCT), without usage of model- or atlas-based segmentation, and to evaluate the method in the pelvic and head-neck region against CT. Methods: CT and MRI scans were obtained from the pelvic region of four patients in supine position using a flat table top only for CT. Stratified CT maps were generated by classifying each voxel based on HU ranges into one of four classes: air, adipose tissue, soft tissue or bone.A hierarchical region-selective algorithm, based on automatic thresholding and clustering, was used to classify tissues from MR Dixon reconstructed fat, In-Phase (IP) and Opposed-Phase (OP) images. First, a body mask was obtained by thresholding the IP image. Subsequently, an automatic threshold on the Dixon fat image differentiated soft and adipose tissue. K-means clustering on IP and OP images resulted in a mask that, via a connected neighborhood analysis, allowing the user to select the components corresponding to bone structures.The pCT was estimated through assignment of bulk HU to the tissue classes. Bone-only Digital Reconstructed Radiographs (DRR) were generated as well. The pCT images were rigidly registered to the stratified CT to allow a volumetric and voxelwise comparison. Moreover, pCTs were also calculated within the head-neck region in two volunteers using the same pipeline. Results: The volumetric comparison resulted in differences <1% for each tissue class. A voxelwise comparison showed a good classification, ranging from 64% to 98%. The primary misclassified classes were adipose/soft tissue and bone/soft tissue. As the patients have been imaged on different table tops, part of the misclassification error can be explained by misregistration. Conclusion: The proposed approach does not rely on an anatomy model providing the flexibility to successfully generate the pCT in two different body sites. This research is founded by ZonMw IMDI Programme, project name: “RASOR sharp: MRI based radiotherapy planning using a single MRI sequence”, project number: 10-104003010.

60 APPLIED LIFE SCIENCES↗

High Performance Computing Based Parallel HIearchical Modal Association Clustering (HPAR HMAC)

For many applications, clustering is a crucial step in order to gain insight into the makeup of a dataset. The best approach to a given problem often depends on a variety of factors, such as the size of the dataset, time restrictions, and soft clustering requirements. The HMAC algorithm seeks to combine the strengths of 2 particular clustering approaches: model-based and linkage-based clustering. One particular weakness of HMAC is its computational complexity. HMAC is not practical for mega-scale data clustering. For high-definition imagery, a user would have to wait months or years for a result; for a 16-megapixel image, the estimated runtime skyrockets to over a decade! To improve the execution time of HMAC, it is reasonable to consider an multi-core implementation that utilizes available system resources. An existing imple-mentation (Ray and Cheng 2014) divides the dataset into N partitions - one for each thread prior to executing the HMAC algorithm. This implementation benefits from 2 types of optimization: parallelization and divide-and-conquer. By running each partition in parallel, the program is able to accelerate computation by utilizing more system resources. Although the parallel implementation provides considerable improvement over the serial HMAC, it still suffers from poor computational complexity, O(N2). Once the maximum number of cores on a system is exhausted, the program exhibits slower behavior. We now consider a modification to HMAC that involves a recursive partitioning scheme. Our modification aims to exploit divide-and-conquer benefits seen by the parallel HMAC implementation. At each level in the recursion tree, partitions are divided into 2 sub-partitions until a threshold size is reached. When the partition can no longer be divided without falling below threshold size, the base HMAC algorithm is applied. This results in a significant speedup over the parallel HMAC.

Patlolla, Dilip R↗

Low Group Delay Dispersion Optical Coating for Broad Bandwidth High Reflection at 45° Incidence, P Polarization of Femtosecond Pulses with 900 nm Center Wavelength

We describe an optical coating design suitable for broad bandwidth high reflection (BBHR) at 45° angle of incidence (AOI), P polarization (Ppol) of femtosecond (fs) laser pulses whose wavelengths range from 800 to 1000 nm. The design process is guided by quarter-wave HR coating properties. Our design must afford low group delay dispersion (GDD) for reflected light over the broad, 200 nm bandwidth in order to minimize temporal broadening of the fs pulses due to dispersive alteration of relative phases between their frequency components. The design should also be favorable to high laser-induced damage threshold (LIDT). We base the coating on TiO 2 /SiO 2 layer pairs produced by means of e-beam evaporation with ion-assisted deposition, and use OptiLayer Thin Film Software to explore designs starting with TiO 2 /SiO 2 layers having thicknesses in a reverse chirped arrangement. This approach led to a design with R > 99% from 800 to 1000 nm and GDD < 20 fs 2 from 843 to 949 nm (45° AOI, Ppol). The design’s GDD behaves in a smooth way, suitable for GDD compensation techniques, and its electric field intensities show promise for high LIDTs. Reflectivity and GDD measurements for the initial test coating indicate good performance of the BBHR design. Subsequent coating runs with improved process calibration produced two coatings whose HR bands satisfactorily meet the design goals. Lastly, for the sake of completeness, we summarize our previously reported transmission spectra and LIDT test results with 800 ps, 8 ps and 675 fs pulses for these two coatings, and present a table of the LIDT results we have for all of our TiO 2 /SiO 2 BBHR coatings, showing the trends with test laser pulse duration from the ns to sub-ps regimes.

36 MATERIALS SCIENCE↗

WE-H-207A-06: Hypoxia Quantification in Static PET Images: The Signal in the Noise

Purpose: Quantification of hypoxia from PET images is of considerable clinical interest. In the absence of dynamic PET imaging the hypoxic fraction (HF) of a tumor has to be estimated from voxel values of activity concentration of a radioactive hypoxia tracer. This work is part of an effort to standardize quantification of tumor hypoxic fraction from PET images. Methods: A simple hypoxia imaging model in the tumor was developed. The distribution of the tracer activity was described as the sum of two different probability distributions, one for the normoxic (and necrotic), the other for the hypoxic voxels. The widths of the distributions arise due to variability of the transport, tumor tissue inhomogeneity, tracer binding kinetics, and due to PET image noise. Quantification of HF was performed for various levels of variability using two different methodologies: a) classification thresholds between normoxic and hypoxic voxels based on a non-hypoxic surrogate (muscle), and b) estimation of the (posterior) probability distributions based on maximizing likelihood optimization that does not require a surrogate. Data from the hypoxia imaging model and from 27 cervical cancer patients enrolled in a FAZA PET study were analyzed. Results: In the model, where the true value of HF is known, thresholds usually underestimate the value for large variability. For the patients, a significant uncertainty of the HF values (an average intra-patient range of 17%) was caused by spatial non-uniformity of image noise which is a hallmark of all PET images. Maximum likelihood estimation (MLE) is able to directly optimize for the weights of both distributions, however, may suffer from poor optimization convergence. For some patients, MLE-based HF values showed significant differences to threshold-based HF-values. Conclusion: HF-values depend critically on the magnitude of the different sources of tracer uptake variability. A measure of confidence should also be reported.

60 APPLIED LIFE SCIENCES↗

Projected increase in compound dry and hot events over global land areas

Abstract Under global warming, dry and hot events have been increasing in recent decades and are projected to increase in the future across global land areas. The impacts of compound dry and hot events may lead to increased stress to the natural and human systems than separate dry or hot events. Thus, quantitative assessments of global land areas affected by these compound events are needed to understand their risks. This study focuses on the variation in global land and cropland areas affected by compound dry and hot events for both historical and future periods using observations from Climatic Research Unit (CRU) and simulations from Coupled Model Intercomparison Project Phase 5 (CMIP5) climate models. Based on historical observations and simulations, a substantial increase in the spatial extent of these compound events was detected, especially since the 1980s. Climate model projections under the Representative Concentration Pathway (RCP) 8.5 scenario reveal that both global land and cropland areas affected by compound dry and hot events will increase to approximately 1.7–1.8 times by the end of the 21st century. Based on different thresholds of compound events, the spatial extent of global land areas during the June–July–August (December–January–February) season will increase by 12.38–17.20% (7.83–11.19%) in 2050–2099 relative to that in 1950–1999, and the spatial extent of global cropland areas will increase by 14.69–19.63% (9.60–14.48%). The increase in areas affected by compound dry and hot events may lead to more losses in different sectors in the future and more efforts are needed to cope with their potential impacts.

Wu, Xinying↗

Sooting characteristics of surrogates for jet fuels

Currently, modeling the combustion of aviation fuels, such as JP-8 and JetA, is not feasible due to the complexity and compositional variation of these practical fuels. Surrogate fuel mixtures, composed of a few pure hydrocarbon compounds, are a key step toward modeling the combustion of practical aviation fuels. For the surrogate to simulate the practical fuel, the composition must be designed to reproduce certain pre-designated chemical parameters such as sooting tendency, H/C ratio, autoignition, as well as physical parameters such as boiling range and density. In this study, we focused only on the sooting characteristics based on the Threshold Soot Index (TSI). New measurements of TSI values derived from the smoke point along with other sooting tendency data from the literature have been combined to develop a set of recommended TSI values for pure compounds used to make surrogate mixtures. When formulating the surrogate fuel mixtures, the TSI values of the components are used to predict the TSI of the mixture. To verify the empirical mixture rule for TSI, the TSI values of several binary mixtures of candidate surrogate components were measured. Binary mixtures were also used to derive a TSI for iso-cetane, which had not previously been measured, and to verify the TSI for 1-methylnaphthalene, which had a low smoke point and large relative uncertainty as a pure compound. Lastly, surrogate mixtures containing three components were tested to see how well the measured TSI values matched the predicted values, and to demonstrate that a target value for TSI can be maintained using various components, while also holding the H/C ratio constant. (author)

02 PETROLEUM↗

Intrafraction Verification of Gated RapidArc by Using Beam-Level Kilovoltage X-Ray Images

Purpose: To verify the geometric accuracy of gated RapidArc treatment using kV images acquired during dose delivery. Methods and Materials: Twenty patients were treated using the gated RapidArc technique with a Varian TrueBeam STx linear accelerator. One to 7 metallic fiducial markers were implanted inside or near the tumor target before treatment simulation. For patient setup and treatment verification purposes, the internal target volume (ITV) was created, corresponding to each implanted marker. The gating signal was generated from the Real-time Position Management (RPM) system. At the beginning of each fraction, individualized respiratory gating amplitude thresholds were set based on fluoroscopic image guidance. During the treatment, we acquired kV images immediately before MV beam-on at every breathing cycle, using the on-board imaging system. After the treatment, all implanted markers were detected, and their 3-dimensional (3D) positions in the patient were estimated using software developed in-house. The distance from the marker to the corresponding ITV was calculated for each patient by averaging over all markers and all fractions. Results: The average 3D distance between the markers and their ITVs was 0.8 {+-} 0.5 mm (range, 0-1.7 mm) and was 2.1 {+-} 1.2 mm at the 95th percentile (range, 0-3.8 mm). On average, a left-right margin of 0.6 mm, an anterior-posterior margin of 0.8 mm, and a superior-inferior margin of 1.5 mm is required to account for 95% of the intrafraction uncertainty in RPM-based RapidArc gating. Conclusion: To our knowledge, this is the first clinical report of intrafraction verification of respiration-gated RapidArc treatment in stereotactic ablative radiation therapy. For some patients, the markers deviated significantly from the ITV by more than 2 mm at the beginning of the MV beam-on. This emphasizes the need for gating techniques with beam-on/-off controlled directly by the actual position of the tumor target instead of external surrogates such as RPM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of window scheduler algorithm exploiting natural ventilation and thermal mass for building energy simulation and smart home controls

Building energy simulations often rely on abstract assumptions when it comes to natural ventilation, such as ‘windows always open [or closed]’ or ‘windows open when outdoor temperature is below a certain threshold.’ However, simulations based on these assumptions fail to fully exploit the cooling potential of natural ventilation, as its effectiveness can be enhanced or diminished by various factors, including the presence of thermal mass. This issue also extends to smart home controls, where determining the window schedule becomes challenging without information about the building's response to outdoor conditions. To address these issues, this study has developed an analytical model for window operation schedules that leverages the passive cooling from natural ventilation. The analytical model was validated against a Modelica simulation. A case study utilizing the BESTEST model of ANSI/ASHRAE Standard 140 underwent validation with EnergyPlus simulations, showing strong concordance. The algorithm provides window schedule recommendations adapted to various airflow rates, thermal masses, and climate variations. Notably, the case study demonstrated that proper window scheduling could reduce indoor temperature by up to 8 °C under the given simulation settings, thereby improving resilience and indicating potential energy savings. Furthermore, the paper explores the potential opportunities and challenges this approach presents, especially for building simulation and smart home applications.

42 ENGINEERING↗

Secondary carbides in high chromium cast irons: An alternative approach to their morphological and spatial distribution characterization

Highlights: • Systematic characterization of second phase particles by combining a variety of techniques • Comparison of morphological parameters obtained from SEM, BSE, etching+CLSM and EBSD • Quantitative analysis and degree of distribution of secondary carbides • Particle size, distribution and morphology from image analysis of CLSM, SEM and EBS images - Abstract: Secondary carbides precipitated in high chromium cast irons during thermal treatments were characterized by means of different characterization techniques, including scanning electron microscopy, energy dispersive X-ray spectroscopy, electron backscattered diffraction and a combination of chemical etching with confocal scanning laser microscopy. This set of techniques provides a full morphological, chemical and crystallographic description of the analysed phases. This work evaluated different methods for optimizing the image acquisition for a further image analysis (IA) based on the threshold binarization. Finally, the carbide size, distribution and morphology were determined after IA of the images acquired by aforementioned characterization techniques. Although the different techniques report some dispersion in the value for the average particle size, the particle inter-spacing and aspect ratio meet within the error value. The proposed characterization methodology provides statistically reliable data for a further evaluation of related physical properties in composites.

36 MATERIALS SCIENCE↗

Polynomial Scaling Localized Active Space Unitary Selective Coupled Cluster Singles and Doubles

We present a polynomial-scaling algorithm for the localized active space unitary selective coupled cluster singles and doubles (LAS-USCCSD) method. In this approach, cluster excitations are selected based on a threshold ϵ determined by the absolute gradients of the LAS-UCCSD energy with respect to cluster amplitudes. Using the generalized Wick’s theorem for multireference wave functions, we derive the gradient expression as a polynomial function of one-, two-, and three-body reduced density matrices and 1- and 2-electron integrals, valid for any multireference wave function. The resulting gradient implementation exhibits a memory scaling of 𝒪(N 6 ), with N spin orbitals in the combined active space of all fragments. The variational quantum eigensolver is used to optimize the selected cluster excitations on a quantum simulator. Furthermore, by plotting the energy error, defined as the difference between the LAS-USCCSD and corresponding CASCI energies, against the inverse cluster amplitude selection threshold (ϵ –1 ) for polyene chains containing 2 to 5 π-bond units, we establish a relationship between the energy error and the threshold. To further validate the accuracy of LAS-USCCSD, we computed the cis–trans isomerization energy of stilbene (a 20-qubit system) and the magnetic coupling constant of the tris-hydroxo-bridged chromium dimer [Cr 2 (OH) 3 (NH 3 ) 6 ] 3+ (evaluated as both 12- and 20-qubit systems) using the Qiskit-Qulacs simulator. Assessing such examples is important to determine the practical feasibility of quantum simulations for chemically realistic systems. Toward this goal, with the LAS-USCCSD algorithm we estimated the quantum resources required for simulating an active space of (30e,22o) in [Cr 2 (OH) 3 (NH 3 ) 6 ] 3+ , a size that remains beyond the reach of current quantum simulators for accurate treatment.

Algorithms↗

Impact of Extreme Heat on Emergency Department Admissions for Childhood and Adult Asthma: An Evaluation of Earth Observations and Heat Wave Definitions

Extreme heat has been associated with adverse health outcomes, yet its impact on asthma exacerbations remains understudied. This is, in part, due to data limitations: research that relies on weather station records and aggregated health statistics cannot resolve fine-scale differences in heat impacts. This study investigates the association between heat wave definitions and summertime asthma-related emergency department visits in Baltimore, Maryland from 2016 to 2022, including 819 adult and 695 pediatric exacerbations. Using geocoded electronic health records and air temperature measurements at several spatial resolutions, we applied a case-crossover design with conditional logistic regressions at the census block group and tract levels. We found strong associations between asthma exacerbations and nighttime heat wave definitions based on relative thresholds of minimum temperatures when census block group or tract level temperature estimates were used. These relationships were significant for both age groups and showed elevated risks in socially vulnerable areas. In contrast, heat wave definitions derived from the city's primary National Weather Service synoptic weather station show associations between asthma and daytime heat extremes, suggesting that the character of the heat hazard depends on the scale at which it is defined. The extreme heat event definition used by Baltimore City's Code Red system showed no significant association with exacerbations. These findings highlight the importance of data resolution in shaping health inferences related to extreme heat in urban environments. Further, this study demonstrates that, regardless of spatial scale, extreme heat is associated with asthma exacerbations in both age groups.

Corpuz, B. [Johns Hopkins University, Baltimore, M↗

Surrogate ratio methodology for the indirect determination of neutron capture cross sections

The relative gamma-decay probabilities of the {sup 162}Dy to {sup 161}Dy and {sup 162}Dy to {sup 164}Dy residual nuclei, produced using light-ion-induced direct reactions, were measured as a function of excitation energy using the CACTUS array at the Oslo Cyclotron Laboratory. The external surrogate ratio method (SRM) was used to convert these relative gamma-decay probabilities into the {sup 161}Dy(n,gamma) cross section in an equivalent neutron energy range of 130-560 keV. The directly measured {sup 161}Dy(n,gamma) cross section, obtained from the Evaluated Nuclear Data Files (ENDF/B-VII.0), was compared to the experimentally determined surrogate {sup 161}Dy(n,gamma) cross section obtained using compound-nucleus pairs with both similar ({sup 162}Dy to {sup 164}Dy) and dissimilar ({sup 162}Dy to {sup 161}Dy) nuclear structures. A gamma-ray energy threshold was identified, based upon pairing gap parameters, that provides a first-order correction to the statistical gamma-ray tagging approach and improves the agreement between the surrogate cross-section data and the evaluated result.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Leptophobic Dark Matter Search from the Coherent–CAPTAIN-Mills Liquid Argon Detector

We report the first results of a search for leptophobic dark matter (DM) from the Coherent–CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and 17.9 × 10 20 protons on target (POT) was performed in fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and nonoptimized shielding, CCM’s first engineering run has already achieved sensitivity to previously unexplored parameter space of light dark matter models with a baryonic vector portal. With an expected background of 115 005 events, we observe 115 005 + 16.5 events which is compatible with background expectations. For a benchmark mediator-to-DM mass ratio of m V B =m χ = 2.1, DM masses within the range 9 MeV ≲ m χ ≲ 50 MeV are excluded at 90% C. L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM’s upgraded run with 200 PMTs, filtered LAr, improved shielding, and 10 times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correlation of Diffusion Limited Oxidation to Color Difference in Accelerated Aging of Electrical Cable Insulation

Diffusion limited oxidation (DLO) as a phenomenon has complicated material lifetime predictions from accelerated aging studies. Many methods to analyze DLO have been developed in recent years. However, an analytical tool for high throughput and low-cost analysis of DLO affected samples remains absent from the literature. Color differences in polymers exposed to oxidative conditions have recently been observed and correlated to increased concentrations of oxidation products. Herein, total color difference was utilized to rapidly quantify DLO in ethylene propylene rubber (EPR) polymeric cable insulation specimens. Insulation specimens were aged at 121 °C, 136 °C, 150 °C, and 165 °C and a 10% ?E*ab difference between the specimen edge and specimen center was used as the threshold for DLO. Based on these specifications DLO was observed in EPR insulation specimen at temperatures of 136 °C and above, with an increasing degree of DLO observed as the time of exposure increased. The method presented in this work represents a quantitative and high-throughput method for the investigation of DLO with a low cost barrier for entry.

diffusion limited oxidation, DLO, nuclear, electri↗

Fiber Uncertainty Visualization for Bivariate Data With Parametric and Nonparametric Noise Models

Visualization and analysis of multivariate data and their uncertainty are top research challenges in data visualization. Constructing fiber surfaces is a popular technique for multivariate data visualization that generalizes the idea of level-set visualization for univariate data to multivariate data. Here, in this paper, we present a statistical framework to quantify positional probabilities of fibers extracted from uncertain bivariate fields. Specifically, we extend the state-of-the-art Gaussian models of uncertainty for bivariate data to other parametric distributions (e.g., uniform and Epanechnikov) and more general nonparametric probability distributions (e.g., histograms and kernel density estimation) and derive corresponding spatial probabilities of fibers. In our proposed framework, we leverage Green's theorem for closed-form computation of fiber probabilities when bivariate data are assumed to have independent parametric and nonparametric noise. Additionally, we present a nonparametric approach combined with numerical integration to study the positional probability of fibers when bivariate data are assumed to have correlated noise. For uncertainty analysis, we visualize the derived probability volumes for fibers via volume rendering and extracting level sets based on probability thresholds. We present the utility of our proposed techniques via experiments on synthetic and simulation datasets.

97 MATHEMATICS AND COMPUTING↗

Development and evaluation of a Novel RT‐PCR system for reliable and rapid SARS‐CoV ‐2 screening of blood donations

Abstract Background The ongoing outbreak of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) has caused great global concerns. In contrast to SARS, some SARS‐CoV‐2–infected people can be asymptomatic or have only mild nonspecific symptoms. Furthermore, there is evidence that SARS‐CoV‐2 may be infectious during an asymptomatic incubation period. With the discovery that SARS‐CoV‐2 can be detected in plasma or serum, blood safety is worthy of consideration. Study Design and Methods We developed a nucleic acid test (NAT) screening system for SARS‐CoV‐2 targeting nucleocapsid protein (N) and open reading frame 1ab (ORF 1ab) gene that could screen 5076 samples every 24 hours. The 2019 novel coronavirus RNA standard was used to evaluate linearity of standard curves. Diagnostic sensitivity and reproducibility were evaluated using artificial SARS‐CoV‐2. Specificity was evaluated with 61 other respiratory pathogens. Diagnostic performance was evaluated by testing two sputum and nine oropharyngeal swab specimens. The reverse transcription polymerase chain reaction (RT‐PCR) assay was used to screen SARS‐CoV‐2 RNA in blood donor specimens collected during the outbreak of SARS‐CoV‐2 in Chengdu. Results Limits of detection of the SARS‐CoV‐2 RT‐PCR assay for N and ORF 1ab gene were 12.5 and 27.58 copies/mL, respectively. Intra‐assay and interassay for the SARS‐CoV‐2 RT‐PCR assay based on cycle threshold were acceptably low. No cross‐reactivity was observed with other respiratory virus and bacterial isolates. The overall agreement value between the SARS‐CoV‐2 RT‐PCR assay and clinical diagnostic results was 100%. A total of 16 287 blood specimens collected from blood donors during SARS‐CoV‐2 surveillance were tested negative. Conclusions A high‐throughput NAT screening system was developed for SARS‐CoV‐2 screening of blood donations during the outbreak of SARS‐CoV‐2.

Li, Meng↗

SU-F-18C-05: Characterization of a Silicon Strip Photon-Counting Detector in the Presence of Compton Scatter: A Simulation Study

Purpose: To investigate the effect of Compton scatter on detection efficiency and charge-sharing for a Si strip photon-counting detector as a function of pixel pitch, slice thickness and total pixel length. Methods: A CT imaging system employing a silicon photon-counting detector was implemented using the GATE Monte Carlo package. A focal spot size of 300 µm, magnification of 1.33, and pixel pitches of 0.1 and 0.5mm were initially investigated. A 60 kVp spectrum with 3 mm Al filter was used and energy spectral degradation based on a prototype detector was simulated. To study charge-sharing, a single pixel was illuminated, and the detector response in neighboring pixels was investigated. A longitudinally semiinfinite detector was simulated to optimize the quantum detection efficiency of the imaging system as a function of pixel pitch, slice thickness and depth of interaction. A 2.5 mm thick tungsten plate with a 0.01 mm by 1.5 mm slit was implemented to calculate the modulation transfer function (MTF) from projection-based images. A threshold of 15 keV was implemented in the detector simulation. The preliminary charge sharing investigation results considered only scattering effects and the detector electronics related factors were neglected. Results: Using a 15 keV threshold, 1% of the pixel charge migrated into neighboring pixels with a pixel size of 0.1×0.1 mm{sup 2}. The quantum detection efficiency was 77%, 84%, 87% and 89% for 15 mm, 22.5 mm, 30 mm, and 45 mm length silicon detector pixels, respectively. For a pixel pitch of 0.1 mm, the spatial frequency at 10% of the maximum MTF was found to be 5.2 lp/mm. This agreed with an experimental MTF measurement of 5.3 lp/mm with a similar detector configuration. Conclusion: Using optimized design parameters, Si strip photon-counting detectors can offer high detection efficiency and spatial resolution even in the presence of Compton scatter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bone-marrow densitometry: Assessment of marrow space of human vertebrae by single energy high resolution-quantitative computed tomography

Purpose: Accurate noninvasive assessment of vertebral bone marrow fat fraction is important for diagnostic assessment of a variety of disorders and therapies known to affect marrow composition. Moreover, it provides a means to correct fat-induced bias of single energy quantitative computed tomography (QCT) based bone mineral density (BMD) measurements. The authors developed new segmentation and calibration methods to obtain quantitative surrogate measures of marrow-fat density in the axial skeleton. Methods: The authors developed and tested two high resolution-QCT (HR-QCT) based methods which permit segmentation of bone voids in between trabeculae hypothesizing that they are representative of bone marrow space. The methods permit calculation of marrow content in units of mineral equivalent marrow density (MeMD). The first method is based on global thresholding and peeling (GTP) to define a volume of interest away from the transition between trabecular bone and marrow. The second method, morphological filtering (MF), uses spherical elements of different radii (0.1–1.2 mm) and automatically places them in between trabeculae to identify regions with large trabecular interspace, the bone-void space. To determine their performance, data were compared ex vivo to high-resolution peripheral CT (HR-pQCT) images as the gold-standard. The performance of the methods was tested on a set of excised human vertebrae with intact bone marrow tissue representative of an elderly population with low BMD. Results: 86% (GTP) and 87% (MF) of the voxels identified as true marrow space on HR-pQCT images were correctly identified on HR-QCT images and thus these volumes of interest can be considered to be representative of true marrow space. Within this volume, MeMD was estimated with residual errors of 4.8 mg/cm{sup 3} corresponding to accuracy errors in fat fraction on the order of 5% both for GTP and MF methods. Conclusions: The GTP and MF methods on HR-QCT images permit noninvasive localization and densitometric assessment of marrow fat with residual accuracy errors sufficient to study disorders and therapies known to affect bone marrow composition. Additionally, the methods can be used to correct BMD for fat induced bias. Application and testing in vivo and in longitudinal studies are warranted to determine the clinical performance and value of these methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗