Search NASA⌕ Search

SEARCH · Search NASA

Results for “time of flight”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

SUDA: A SUrface Dust Analyser for Compositional Mapping of the Galilean Moon Europa

Abstract The Surface Dust Analyser (SUDA) is a mass spectrometer onboard the Europa Clipper mission for investigating the surface composition of the Galilean moon Europa. Atmosphereless planetary moons such as the Galilean satellites are wrapped into a ballistic dust exosphere populated by tiny samples from the moon’s surface produced by impacts of fast micrometeoroids. SUDA will measure the composition of such surface ejecta during close flybys of Europa to obtain key chemical signatures for revealing the satellite’s composition such as organic molecules and salts, history, and geological evolution. Because of their ballistic orbits, detected ejecta can be traced back to the surface with a spatial resolution roughly equal to the instantaneous altitude of the spacecraft. SUDA is a Time-Of-Flight (TOF), reflectron-type impact mass spectrometer, optimized for a high mass resolution which only weakly depends on the impact location. The instrument will measure the mass, speed, charge, elemental, molecular, and isotopic composition of impacting grains. The instrument’s small size of$268 ~\mathrm {mm} \times 250 ~\mathrm {mm} \times 171$ 268 mm × 250 mm × 171 $~\mathrm {mm}$ mm , radiation-hard design, and rather large sensitive area of 220 cm 2 matches well the challenging demands of the Clipper mission.

Astronomy & Astrophysics↗

Atmospheric Ion Composition, SGP, April-May 2023

These files contain select ion count rates measured by an atmospheric pressure interface time-of-flight mass spectrometer (APi-ToF) at the Atmospheric Radiation Measurement Southern Great Plains site from April 28, 2023 to May 31, 2023. Files are in ICARTT format. The APi-ToF measures the chemical composition of naturally charged ions using mass spectrometry. Due to the nature of the measurements, time-series data are non-quantitative. This dataset contains time-series information for the ions that are typically the most intense ions observed.

54 ENVIRONMENTAL SCIENCES↗

Progress on Associate-Particle Imaging Algorithms, 2020

The present work describes progress on the development of imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating between critical materials or extracting three-dimensional geometrical information from single-sided or transmission measurements. The present work is divided into three approaches:(1)Iterative reconstruction of inelastic gamma-ray emissions to perform three-dimensional time-of-flight imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution.(2)Decomposition of registered neutron and x ray radiographs into an assumed material list for each pixel in the image.(3)Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles.Progress for each approach is summarized for fiscal year 2020.

97 MATHEMATICS AND COMPUTING↗

Progress on Associated-Particle Imaging Algorithms, 2022

The present work describes progress on developing imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating among critical materials or extracting three-dimensional (3D) geometrical information from single-sided or transmission measurements. The present work is divided into three approaches: 1.Iterative reconstruction of inelastic gamma-ray emissions to perform 3D time-of-flight (TOF) imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution. 2.Decomposition of registered neutron and x-ray radiographs into an assumed material list for each pixel in the image. 3.Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles. Progress for each approach is summarized for fiscal year (FY) 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution vibrational predissociation spectroscopy of I - ·H 2 O by single-mode CW infrared excitation in a 3D cryogenic ion trap

We describe the integration of a tunable, single-mode, continuous wave infrared laser into a cryogenic ion spectroscopy experiment to measure the rovibrational spectrum of the I - ∙H 2 O complex in the OH stretching region. These upper levels lie about 300 cm -1 above the dissociation threshold. The measurements are carried out by loading the ions in a radiofrequency ion trap at 10 Hz and cooling them to 5 K with pulsed He buffer gas. IR photodissociation (PD) of the I - ∙H 2 O complex is monitored by recording the I - product yield by time-of-flight mass spectrometry as a function of laser wavelength. Very narrow (Δν~75 MHz) rotational lines are observed throughout the spectrum, indicating long (ca. 2 ns) lifetimes for the excited metastable rovibrational levels. Rotational analysis of the band arising from the K”=1 to K’=2 transition of the free OH stretching fundamental yields the structure of the complex for the first time. Over 50% of the trapped ion ensemble in the trap can be photodissociated upon excitation of a single rotational line. This enables very high signal-to-noise in the PD spectrum, and is traced to a mechanism in which the ground state rotational levels are rapidly equilibrated by collisions with the buffer gas.

74 ATOMIC AND MOLECULAR PHYSICS↗

CO 2 in Ionene–Ionic Liquid Composite Membranes

Abstract Ionene – ionic liquid (IL) composites are promising materials for CO 2 separation, yet a molecular‐level understanding of their structure and its impact on CO 2 speciation, solubility, rotation, and diffusivity remains unclear. Herein, using multimodal nuclear magnetic resonance (NMR), time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS), atomic force microscopy (AFM), and molecular dynamics (MD) simulations, we reveal that the composites contain IL‐rich domains extending across hundreds of nanometres within the ionene matrix, and these bicontinuous domains span the entire membrane depth. CO 2 also absorbs into the ionene matrix, with the distribution between two CO 2 species varying with temperature and time. The rotational correlation times of these two species are on the timescale of 0.1 and 1 ns, respectively. As IL content increases, the ionic domains expand, resulting in higher CO 2 solubility due to enhanced molecular dynamics and increased free volume in both ionene backbones and IL‐rich regions. Although CO 2 diffusion in the membranes is an order of magnitude slower than in bulk IL, the activation energy for CO 2 diffusion remains comparable. Ionene‐IL composites represent a promising platform for designing CO 2 separation membranes, offering enhanced CO 2 diffusion and selectivity through IL‐rich domains, and increased CO 2 solubility and mechanical integrity from the ionene matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

β -delayed neutron spectroscopy of Co 70 , 72 ground-state and isomeric-state decays

Here, the β-decaying states of 70,72 Co were studied at the National Superconducting Cyclotron Laboratory using the VANDLE neutron time-of-flight array. The (6 - ,7 - )⁢β-decaying state in 70 Co is near-spherical with a lifetime of 113 ± 7 ms, and the low-spin (1 + ,2 + )⁢β-decaying state is postulated to be the prolate deformed ground state with a lifetime of 508 ± 7 ms. Both decay predominantly to the bound states of 70 Ni. For the first time neutron-emissions from neutron unbound states from both the (6 - ,7 - ) and (1 + ,2 + )⁢β decays were measured. Even with the low statistics data, we were able to disentangle the neutron emission from both decays, which enabled a determination of β-decay strength above the neutron separation energy of 70 Ni. Neutron emission probabilities were measured to be 7.1 ± 1.5% and 9.4 ± 1.7%, respectively, for the (6 - ,7 - ) and (1 + ,2 + ) decays. The decay pattern of the 70 Co is driven by neutron f 5/2 to proton f 7/2 Gamow-Teller transformation. The observed population of neutron unbound states is attributed to the conversion of p 1/2 and p 3/2 neutrons to p 3/2 and p 1/2 protons excited across the Z = 28 closed shell.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studying Interfacial Dark Reactions of Glyoxal and Hydrogen Peroxide Using Vacuum Ultraviolet Single Photon Ionization Mass Spectrometry

Aqueous secondary organic aerosol (aqSOA) formation from volatile and semivolatile organic compounds at the air–liquid interface is considered as an important source of fine particles in the atmosphere. However, due to the lack of in situ detecting techniques, the detailed interfacial reaction mechanism and dynamics still remain uncertain. In this study, synchrotron-based vacuum ultraviolet single-photon ionization mass spectrometry (VUV SPI-MS) was coupled with the System for Analysis at the Liquid Vacuum Interface (SALVI) to investigate glyoxal dark oxidation products at the aqueous surface. Mass spectral analysis and determination of appearance energies (AEs) suggest that the main products of glyoxal dark interfacial aging are carboxylic acid related oligomers. Furthermore, the VUV SPI-MS results were compared and validated against those of in situ liquid time-of-flight secondary ion mass spectrometry (ToF-SIMS). The reaction mechanisms of the dark glyoxal interfacial oxidation, obtained using two different approaches, indicate that differences in ionization and instrument operation principles could contribute to their abilities to detect different oligomers. Therefore, the mechanistic differences revealed between the VUV SPI-MS and ToF-SIMS indicate that more in situ and real-time techniques are needed to investigate the contribution of the air–liquid interfacial reactions leading to aqSOA formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CROCUS Air Quality Dataset from the University of Illinois Chicago (UIC), July 2024

This dataset was collected by the measurement system in the Atmosphere, Climate, and Ecosystems (ACE) Lab at the University of Illinois Chicago (UIC) from July 12 to July 31, 2024, as part of the Community Research on Climate and Urban Science (CROCUS) Urban Integrated Field Laboratory (UIFL) project, led by Argonne National Laboratory.To enhance understanding of urban air quality dynamics in Chicago, and as part of the CROCUS 2024 Urban Canyon Intensive Observation Period (IOP), several instruments were set up to provide continuous measurements of air quality parameters in Chicago during July 2024. These measurements cover both aerosols and gas-phase species. It focuses on particle size distribution (2.5–478 nm) measured by two Scanning Mobility Particle Sizers (SMPS) at a 4-min resolution, total particle number concentrations at a 1-s resolution, and chemical composition from a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (AMS) at a 1-min resolution. Key gas-phase species, including NO, NO₂, SO₂, and O₃, are measured at a 1-min resolution, along with high-resolution NO and dimethyl sulfide (DMS) data from a Chemical Ionization Mass Spectrometer (CIMS). Volatile organic compound (VOC) data for toluene, isoprene, and benzene are provided by a GC-PID with a time resolution of 25 minutes.The data are formatted as NetCDF (.nc) files, making them easily accessible using common software such as MATLAB, R, and Python. Each parameter is stored in an individual dataset, which includes detailed instrument information in the header, as well as the corresponding sample start time and concentration/distribution data for each sample.

54 ENVIRONMENTAL SCIENCES↗

Search for heavy neutral leptons decaying into muon-pion pairs in the MicroBooNE detector

We present upper limits on the production of heavy neutral leptons (HNLs) decaying to $\mu \pi$ pairs using data collected with the MicroBooNE liquid-argon time projection chamber (TPC) operating at Fermilab. This search is the first of its kind performed in a liquid-argon TPC. We use data collected in 2017 and 2018 corresponding to an exposure of $2.0 \times 10^{20}$ protons on target from the Fermilab Booster Neutrino Beam, which produces mainly muon neutrinos with an average energy of $\approx 800$ MeV. HNLs with higher mass are expected to have a longer time-of-flight to the liquid-argon TPC than Standard Model neutrinos. The data are therefore recorded with a dedicated trigger configured to detect HNL decays that occur after the neutrino spill reaches the detector. We set upper limits at the $90\%$ confidence level on the element $\lvert U_{\mu4}\rvert^2$ of the extended PMNS mixing matrix in the range $\lvert U_{\mu4}\rvert^2<(6.6$-$0.9)\times 10^{-7}$ for Dirac HNLs and $\lvert U_{\mu4}\rvert^2<(4.7$-$0.7)\times 10^{-7}$ for Majorana HNLs, assuming HNL masses between $260$ and $385$ MeV and $\lvert U_{e 4}\rvert^2 = \lvert U_{\tau 4}\rvert^2 = 0$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC

Many highly pixelated organic scintillator detection systems would benefit from independent readout of each scintillator pixel. Recent advances in Silicon Photomultiplier (SiPM) technology makes this goal feasible, however the data acquisition from potentially hundreds or thousands of channels requires a low-cost and compact solution. For pixelated neutron detection with organic scintillators, the capability to distinguish between neutron and gamma interactions using Pulse Shape Discrimination (PSD) is required along with pulse charge and time of arrival. The TOFPET2 ASIC from PETsys Electronics is a 64-channel readout chip providing pulse time and charge integration measurements from SiPMs, and is specifically designed for time-of-flight positron-emission tomography. Using an 8 × 8 array of 6 mm × 6 mm J-series SiPMs from SensL/OnSemi (ArrayJ-60035-64P-PCB), we have studied the energy and PSD performance of the TOFPET2 ASIC using a 4 × 4 array of 6 mm × 6 mm × 30 mm trans -Stilbene crystals from Inrad Optics and a custom SiPM routing board from PETsys Electronics. In conclusion, using a time-over-threshold method, we measure a maximum PSD figure-of-merit of approximately 1.2 at 478 keV (the Compton edge of 662 keV) for a J-series SiPM operating at an over-voltage of 3V.

47 OTHER INSTRUMENTATION↗

Results of the first implementation of RF phase signature matching at LANSCE

The LINAC at the Los Alamos Neutron Science Center (LANSCE) has been utilizing the Delta-t method to match the RF cavities to the design acceleration parameters since its commissioning in 1972. The differences in time-of-flight between two subsequent Beam Position and Phase Monitors (BPPMs) are measured with both accelerated and drifting beams, depending on the whether the module is set to on or off. The algorithm optimizes the module amplitude and phase via iterative measurements if the initial phase is in the vicinity of the design value. With an upgrade to a faster readout system, a scan over the whole RF cavity phase range requires relatively less time than the classical optimization procedure. The Phase Scan Signature Matching (PSSM) method provides a time-efficient method that ensures the phase selection lands on the bunching side and empowers future analyses to build module-specific models. The PSSM also utilizes a direct model to determine the correct amplitude to sub-percent level instead of using linearized matrices. Furthermore, lacking a reliable energy measurement method in the LINAC, we measure the beam phases at two downstream locations to increase the precision of energy measurements. In this letter, we also discuss the sensitivities of PSSM, error propagation, and the implementation results for the 2019 and 2020 beam cycles.

47 OTHER INSTRUMENTATION↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo↗

The lattice parameter – composition relationship of the body centered cubic uranium-niobium alloys

In this paper, in-situ time-of-flight neutron diffraction experiments were performed on uranium-niobium alloy with 6 wt% Nb to study the lattice parameter-composition relationship for the body centered cubic (bcc) alloys. Based on lattice-parameter measurements of Nb-supersaturated γs phase over the range of 450 – 790 °C, an improved Vegard's-type relationship was established for determination of Nb concentrations at elevated temperatures. Neutron diffraction data were also collected as a function of aging time over the 450 - 600 °C range when γs phase decomposed isothermally into the mixture of orthorhombic α-U and Nb-rich bcc phase, as well as at room-temperature on the alloys aged ex-situ at 500 °C up to five years. From these measurements, the average Nb concentrations in the bcc phase were determined based on the Rietveld refinements of weight fraction and mass conservation relations (lever rule). Over the 15at% – 78at% range of Nb concentrations that correspond to different experimental aging times, the lattice parameters at constant temperatures exhibit a nonlinear S-shaped variation with Nb concentration, and the associated excess volumes of mixing can be described by a subregular solution model of the Redlich–Kister type of polynomial. Over the full range of composition the S-shaped deviation from Vegard's law can be modeled using a combination of an elastic continuum model and a perturbation to the radii of the solute atoms in the solvent, suggesting that electronic interactions between solute and solvent atoms could play an important role in the compositional dependence of lattice parameter for the γ-phase U-Nb alloys. While Vegard's law is a straightforward and reasonably good approximation for the bcc solid solutions in the U-Nb system, the Nb concentrations determined from the weight fraction refinements of diffraction data provide internally consistent, mass-conserving estimates of solute redistribution for the monotectoid reaction.

36 MATERIALS SCIENCE↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Production and discovery of neutron-rich isotopes by fragmentation of 198 Pt

Production cross sections were measured for fragments produced by an 85 MeV/u 198 Pt beam incident on a beryllium target. Event-by-event particle identification of A, Z, and q for the reaction products was performed by employing energy loss, time-of-flight, magnetic rigidity, and total kinetic energy measurements. Over 70 nuclei in the Hf-Pt region were identified, including three isotopes first observed in this work: 191,192 Hf and 189 Lu. Due to the existence of multiple charge states between H-like and C-like ions, a new analysis method was introduced, incorporating Monte Carlo calculations of charge state fractions for a given charge state of the projectile residue just after the reaction. For the first time, charge-state probability distribution functions after the reaction have been deduced from experimental data. Furthermore, this study provides insight into how to produce key nuclides near N = 126 and the ability of a fragmentation residue to retain electrons from the primary beam.

190 ≤ A ≤ 219↗

µRWELL-PICOSEC: The Development of Fast Timing Resistive Micro-WELL Detector Technology.

We present the development of a new concept of fast timing gaseous detector, the ?RWELL-PICOSEC detector based on Resistive Micro-Well (?RWELL) technology to provide timing resolution in the tens of picosecond range for application as time-of-flight (TOF) technology in the particle physics and medical instrumentation fields. The ?RWELL-PICOSEC technology combined a Cerenkov radiator for the generation of Cerenkov photons from high energy charged particles, a photocathode for the conversion of the produced photons into primary electrons and the ?RWELL foil for the multiplication of the electron to produce large signal on pad segmentation readout. The proof of concept of ?RWELL-PICOSEC is demonstrated with a small single-channel prototype and preliminary timing performance of 90 ps has been measured. Optimization study the amplification structure of ?RWELL-PICOSEC for the improvement of timing resolution is discussed and results on timing performance studies in beam at CERN are presented. The development of large area (100 mm × 100 mm) ?RWELL-PICOSEC and associated multichannel fast readout electronics and data acquisition system are also reported

Weisenberger, Andrew↗