Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Efficient Photoinduced Charge Injection from Chemical-Bath Deposited CdS into Mesoporous TiO2 Probed with Time-Resolved Microwave Conductivity

We use the contactless time-resolved microwave conductivity (TRMC) technique to investigate the photoconductance of CdS-coated mesoporous TiO2 and ZrO2. The CdS domains were grown directly on the surface of the oxide by a chemical bath deposition method. Mobile charge carriers are generated with a low yield following photoexcitation of CdS grown on ZrO2; there is no injection into the oxide and the short-lived photoconductance signal is attributed to the hole in CdS. In contrast, illumination of CdS domains grown on TiO2 results in very efficient electron injection into the TiO2 nanoparticles, producing long-lived charge carriers. We show that the quantum yield for electron injection into TiO2 per photon absorbed by the CdS sensitizer is close to unity. The photoconductance action spectrum follows the absorption of the CdS domains, which indicates that the charge injection efficiency does not depend on wavelength in the range where the CdS absorbs (425-550 nm).

absorption↗

Quantitative analysis of time-resolved microwave conductivity data

Flash-photolysis time-resolved microwave conductivity (fp-TRMC) is a versatile, highly sensitive technique for studying the complex photoconductivity of solution, solid, and gas-phase samples. The purpose of this paper is to provide a standard reference work for experimentalists interested in using microwave conductivity methods to study functional electronic materials, describing how to conduct and calibrate these experiments in order to obtain quantitative results. The main focus of the paper is on calculating the calibration factor, K, which is used to connect the measured change in microwave power absorption to the conductance of the sample. We describe the standard analytical formulae that have been used in the past, and compare them to numerical simulations. This comparison shows that the most widely used analytical analysis of fp-TRMC data systematically under-estimates the transient conductivity by ~60%. We suggest a more accurate semi-empirical way of calibrating these experiments. However, we emphasize that the full numerical calculation is necessary to quantify both transient and steady-state conductance for arbitrary sample properties and geometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Subpicosecond time-resolved studies of coherent phonon oscillations in thin-film YBa2Cu3O(6+x) (x less than 0.4)

The results are reported of the first time-resolved observation of impulsively generated coherent optical phonon oscillations in the semiconducting cuprate compound YBa2Cu3O(6+x ) (x less than 0.4). The oscillations, which were probed through time-resolved transmissivity modulation, had a period of 237 fsec at room temperature, corresponding to a Raman active mode at A(1g) symmetry at 142/cm. No oscillations were observed in the superconducting form of Y-Ba-Cu-O either above or below Tc. The amplitude, frequency, and linewidth of this mode were measured over a temperature range from about 7 K to room temperature.

Chwalek, J. M.↗

Evaluation of hole-spin superposition in GaAs/AlGaAs quantum wells through time-resolved photoluminescence measurements

Relaxation dynamics of the up–down superposition of hole spins in undoped GaAs/AlGaAs quantum wells were investigated by means of time-resolved photoluminescence (PL) measurements with a view toward achieving quantum bits using hole spins. Linearly polarized PL signals reflecting the hole-spin superposition were observed using linearly polarized excitation light under quasi-resonant excitation conditions. In contrast to circular-polarization experiments conducted under nonresonant excitation conditions, the decay time of the degree of linear polarization obtained from the time-resolved PL signal increased slightly with increasing quantum confinement energy. These experimental results demonstrate that the creation and observation of hole-spin superposition under resonant conditions are crucial for manipulating hole-spin quantum bits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-resolved quantification of key species and mechanistic insights in low-temperature tetrahydrofuran oxidation

Here, we investigate the kinetics and report the time-resolved concentrations of key chemical species in the oxidation of tetrahydrofuran (THF) at 7500 torr and 450–675 K. Experiments are carried out using high-pressure multiplexed photoionization mass spectrometry (MPIMS) combined with tunable vacuum ultraviolet radiation from the Berkely Lab Advanced Light Source. Intermediates and products are quantified using reference photoionization (PI) cross sections, when available, and constrained by a global carbon balance tracking approach at all experimental temperatures simultaneously for the species without reference cross sections. From carbon balancing, we determine time-resolved concentrations for the ROO˙ and ˙OOQOOH radical intermediates, butanedial, and the combined concentration of ketohydroperoxide (KHP) and unsaturated hydroperoxide (UHP) products stemming from the ˙QOOH + O 2 reaction. Furthermore, we quantify a product that we tentatively assign as fumaraldehyde, which arises from UHP decomposition via H 2 O or ˙OH + H loss. The experimentally derived species concentrations are compared with model predictions using the most recent literature THF oxidation mechanism of Fenard et al., (Combust. Flame, 2018, 191, 252–269). Our results indicate that the literature mechanism significantly overestimates THF consumption and the UHP + KHP concentration at our conditions. The model predictions are sensitive to the rate coefficient for the ROO˙ isomerization to ˙QOOH, which is the gateway for radical chain propagating and branching pathways. Comparisons with our recent results for cyclopentane (Demireva et al., Combust. Flame, 2023, 257, 112506) provide insights into the effect of the ether group on reactivity and highlight the need to determine accurate rate coefficients of ROO˙ isomerization and subsequent reactions.

Demireva, Maria↗

A tabletop femtosecond time-resolved soft x-ray transient absorption spectrometer

A laser-based, tabletop instrument is constructed to perform femtosecond soft x-ray transient absorption spectroscopy. Ultrashort soft x-ray pulses produced via high-order harmonic generation of the amplified output of a femtosecond Ti:sapphire laser system are used to probe atomic core-level transient absorptions in atoms and molecules. The results provide chemically specific, time-resolved dynamics with sub-50-fs time resolution. In this setup, high-order harmonics generated in a Ne-filled capillary waveguide are refocused by a gold-coated toroidal mirror into the sample gas cell, where the soft x-ray light intersects with an optical pump pulse. The transmitted high-order harmonics are spectrally dispersed with a homebuilt soft x-ray spectrometer, which consists of a gold-coated toroidal mirror, a uniform-line spaced plane grating, and a soft x-ray charge coupled device camera. The optical layout of the instrument, design of the soft x-ray spectrometer, and spatial and temporal characterizations of the high-order harmonics are described. Examples of static and time-resolved photoabsorption spectra collected on this apparatus are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A table-top femtosecond time-resolved soft x-ray transient absorption spectrometer

A laser-based, table-top instrument is constructed to perform femtosecond soft x-ray transient absorption spectroscopy. Ultrashort soft x-ray pulses produced via high-order harmonic generation of the amplified output of a femtosecond Ti:sapphire laser system are used to probe atomic core-level transient absorptions in atoms and molecules. The results provide chemically specific, time-resolved dynamics with sub-50-fs time resolution. In this setup, high-order harmonics generated in a Ne-filled capillary waveguide are refocused by a gold-coated toroidal mirror into the sample gas cell, where the soft x-ray light intersects with an optical pump pulse. The transmitted high-order harmonics are spectrally dispersed with a home-built soft x-ray spectrometer, which consists of a gold-coated toroidal mirror, a uniform-line spaced plane grating, and a soft x-ray CCD camera. The optical layout of the instrument, design of the soft x-ray spectrometer, and spatial and temporal characterization of the high-order harmonics are described. Examples of static and time-resolved photoabsorption spectra collected on this apparatus are presented.

47 OTHER INSTRUMENTATION↗

Space-Charge Aberrations in Single-Shot Time-Resolved Transmission Electron Microscopy

In this paper, we discuss effects of space-charge fields on imaging performance in a single-shot time-resolved transmission electron microscope. Using a Green’s function perturbation method, we derive analytical estimates for the effects of space-charge nonlinearity on the image formation process and the associated aberration coefficients. The dependence of these coefficients on the initial beam phase space distribution is elucidated. The results are validated by particle tracking simulations and provide fundamental scaling laws for the trade-off between temporal and spatial resolutions in single-shot time-resolved transmission electron microscopy.

43 PARTICLE ACCELERATORS↗

Time-resolved velocity and ion sound speed measurements from simultaneous bow shock imaging and inductive probe measurements

We present a technique to measure the time-resolved velocity and ion sound speed in magnetized, supersonic high-energy-density plasmas. We place an inductive (“b-dot”) probe in a supersonic pulsed-power-driven plasma flow and measure the magnetic field advected by the plasma. As the magnetic Reynolds number is large (R M > 10), the plasma flow advects a magnetic field proportional to the current at the load. This enables us to estimate the flow velocity as a function of time from the delay between the current at the load and the signal at the probe. The supersonic flow also generates a hydrodynamic bow shock around the probe, the structure of which depends on the upstream sonic Mach number. By imaging the shock around the probe with a Mach–Zehnder interferometer, we determine the upstream Mach number from the shock Mach angle, which we then use to determine the ion sound speed from the known upstream velocity. We use the sound speed to infer the value of Z̄T e , where Z̄ is the average ionization and T e is the electron temperature. We use this diagnostic to measure the time-resolved velocity and sound speed of a supersonic (M S ~ 8), super-Alfvénic (M A ~ 2) aluminum plasma generated during the ablation stage of an exploding wire array on the Magpie generator (1.4 MA, 250 ns). The velocity and Z̄T e measurements agree well with the optical Thompson scattering measurements reported in the literature and with 3D resistive magnetohydrodynamic simulations in GORGON.

47 OTHER INSTRUMENTATION↗

Artifacts in time-resolved Kelvin probe force microscopy

Kelvin probe force microscopy (KPFM) has been used for the characterization of metals, insulators, and semiconducting materials on the nanometer scale. Especially in semiconductors, the charge dynamics are of high interest. Recently, several techniques for time-resolved measurements with time resolution down to picoseconds have been developed, many times using a modulated excitation signal, e.g. light modulation or bias modulation that induces changes in the charge carrier distribution. For fast modulation frequencies, the KPFM controller measures an average surface potential, which contains information about the involved charge carrier dynamics. Here, we show that such measurements are prone to artifacts due to frequency mixing, by performing numerical dynamics simulations of the cantilever oscillation in KPFM subjected to a bias-modulated signal. For square bias pulses, the resulting time-dependent electrostatic forces are very complex and result in intricate mixing of frequencies that may, in some cases, have a component at the detection frequency, leading to falsified KPFM measurements. Additionally, we performed fast Fourier transform (FFT) analyses that match the results of the numerical dynamics simulations. Small differences are observed that can be attributed to transients and higher-order Fourier components, as a consequence of the intricate nature of the cantilever driving forces. These results are corroborated by experimental measurements on a model system. In the experimental case, additional artifacts are observed due to constructive or destructive interference of the bias modulation with the cantilever oscillation. Also, in the case of light modulation, we demonstrate artifacts due to unwanted illumination of the photodetector of the beam deflection detection system. Lastly, guidelines for avoiding such artifacts are given.

36 MATERIALS SCIENCE↗

Revealing excitonic structure and charge transfer in photosynthetic proteins by time-resolved circular dichroism spectroscopy

The author has designed and built a time-resolved circular dichroism (CD) spectrometer with previously unmatched sensitivity making for the first time this technique suitable to studies of energy transfer and structure of photosynthetic light-harvesting and charge transfer complexes. The nanosecond version of the new CD spectrometer was successfully applied to studies of the Fenna Matthews Olson pigment-protein complex showing a number of features incompatible with currently proposed Hamiltonians and providing a wealth in information for refining our current understanding of this complex structure and dynamics. The work on femtosecond variant of ultra sensitive CD spectrometer was initiated and demonstrated its capability to resolve CD differences in the order of 10 -8 , which is 2-3 orders of magnitude better than previously proposed spectrometers.

59 BASIC BIOLOGICAL SCIENCES↗

Employing time-resolved terahertz spectroscopy to analyze carrier dynamics in thin-film Cu{sub 2}ZnSn(S,Se){sub 4} absorber layers

We report the application of time-resolved terahertz spectroscopy (TRTS) to measure photoexcited carrier lifetimes and mobility, and to determine recombination mechanisms in Cu{sub 2}ZnSn(S,Se){sub 4} (CZTSSe) thin films fabricated from nanocrystal inks. Ultrafast time resolution permits tracking the evolution of carrier density to determine recombination rates and mechanisms. The carrier generation profile was manipulated by varying the photoexcitation wavelength and fluence to distinguish between surface, Shockley-Read-Hall (SRH), radiative, and Auger recombination mechanisms and determine rate constants. Surface and SRH recombination are the dominant mechanisms for the air/CZTSSe/SiO{sub 2}/Si film stack. Diffusion to, and then recombination at, the air-CZTSSe interface occurred on the order of 100 picoseconds, while SRH recombination lifetimes were 1–2 nanoseconds. TRTS measurements can provide information that is complementary to conventional time-resolved photoluminescence measurements and can direct the design of efficient thin film photovoltaics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrafast time-resolved x-ray scattering reveals diffusive charge order dynamics in La 2-x Ba x CuO 4

Charge order is universal among high-T c cuprates but its relation to super-conductivity is unclear. While static order competes with superconductivity,dynamic order may be favorable and even contribute to Cooper pairing. Using time-resolved resonant soft x-ray scattering at a free electron laser, we show that the charge order in prototypical La 2–x Ba x CuO 4 exhibits transverse fluctuations at ps timescales. These sub-meV excitations propagate by Brownian-like diffusion and have an energy scale remarkably close to the superconducting T c . At sub-meV energy scales, the dynamics are governed by universal scaling laws defined by propagation of topological defects. Our results show that charge order in La 2–x Ba x CuO 4 exhibits dynamics favorable to the in-plane superconducting tunneling, and establish time-resolved x-rays as a means to study excitations at energy scales inaccessible to conventional scattering techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-resolved resonant inelastic x-ray scattering in a pumped Mott insulator

Collective excitations contain rich information about photoinduced transient states in correlated systems. In a Mott insulator, charge degrees of freedom are frozen, but can be activated by photodoping. The energy-momentum distribution of the charge excitation spectrum reflects the propagation of charge degrees of freedom and provides information about the interplay among various intertwined instabilities on the timescale set by the pump. To reveal charge excitations out of equilibrium, here we simulate time-resolved x-ray absorption and resonant inelastic x-ray scattering using a Hubbard model. After pumping, the former resolves photodoping, while the latter characterizes the formation, dispersion, weight, and nonlinear effects of collective excitations. Intermediate-state information from time-resolved resonant inelastic x-ray scattering (trRIXS) can be used to decipher the origin of these excitations, including bimagnons, Mott-gap excitations, doublon and single-electron in-gap states, and anti-Stokes relaxation during an ultrafast pump. This paper provides a theoretical foundation for existing and future trRIXS experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of excited state molecular structures from time-resolved gas-phase X-ray scattering

We present a comprehensive investigation of a recently introduced method to determine transient structures of molecules in excited electronic states with sub-ångstrom resolution from time-resolved gas-phase scattering signals. The method, which is examined using time-resolved X-ray scattering data measured on the molecule N-methylmorpholine (NMM) at the Linac Coherent Light Source (LCLS), compares the experimentally measured scattering patterns against the simulated patterns corresponding to a large pool of molecular structures to determine the full set of structural parameters. In addition, we examine the influence of vibrational state distributions and find the effect negligible within the current experimental detection limits, despite that the molecules have a comparatively high internal vibrational energy. Here, the excited state structures determined using three structure pools generated using three different computational methods are in good agreement, demonstrating that the procedure is largely independent of the computational chemistry method employed as long as the pool is sufficiently expansive in the vicinity of the sought structure and dense enough to yield good matches to the experimental patterns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Deflection gating for time-resolved x-ray magnetic circular dichroism-photoemission electron microscopy using synchrotron radiation

In this paper, we present a newly developed gating technique for a time-resolving photoemission microscope. The technique makes use of an electrostatic deflector within the microscope's electron optical system for fast switching between two electron-optical paths, one of which is used for imaging, while the other is blocked by an aperture stop. The system can be operated with a switching time of 20 ns and shows superior dark current rejection. We report on the application of this new gating technique to exploit the time structure in the injection bunch pattern of the synchrotron radiation source BESSY II at Helmholtz-Zentrum Berlin for time-resolved measurements in the picosecond regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Higgs oscillations in time-resolved optical conductivity

Driving superconductors out of equilibrium is a promising avenue to study their equilibrium properties as well as to control the superconducting state. Nonequilibrium superconductors are often studied using time-resolved optical conductivity measurements. Thus, the characterization of a superconducting state in a pump driven nonequilibrium state requires careful attention in the time domain. We calculate the time-resolved optical conductivity of a pumped superconducting state using a nonequilibrium Keldysh approach. Through functional derivation, the optical conductivity is obtained with full vertex corrections and used to characterize the transient superconducting state. The transient optical conductivity shows the suppression of the superconducting order parameter in the time domain. The subsequent recovery of the order parameter exhibits oscillatory behavior that corresponds to the Higgs amplitude mode, and may be seen in several parts of the spectrum.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Validations of Time-Resolved X-Ray Emissions Spectroscopy for Analysis of Mn-Based Natural and Artifical Sunlight-to-Energy Assemblies

The goal of this project was to demonstrate time resolved analysis of the electronic structure dynamic using techniques of miniature X-ray emission spectrometers. The focus was on development of easy/fast to set up, portable, cost efficient, good energy resolution, good sensitivity, dispersive (particularly suitable for time resolved analysis) system. These mile stones were achieved and miniXES spectrometer for the Mn Kβ range was reported. Contrary to pointby- point detection, the miniXES setup allows a complete emission spectrum to be recorded following each laser excitation, Fig. 1. miniXES system compares favorably with other realization of a dispersive XES spectrometer with cylindrically bent analyzers. Setup reported by others has disadvantages of high cost (which limits its re-creation by other researchers) and lower (0.55 eV) energy resolution (at 6490 eV). The energy resolution of our miniXES system is 0.30 eV. Additional advantage of portability allowed us to use miniXES at multiple beamlines at APS (ANL): 20-ID, 14-ID and 7-ID. Moreover, in March 2013 PI transported the Mn Kβ spectrometer (which fits into a small hand luggage bag) to SLS (Switzerland) and set it up there for the TR-XES beamtime. Our spectrometer works with 2D-PSD (Pilatus-100) which is a standard detector available via equipment pool at synchrotron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗