Search NASA⌕ Search

SEARCH · Search NASA

Results for “traceable calibrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Toward more realistic projections of soil carbon dynamics by Earth system models

Soil carbon (C) is a critical component of Earth system models (ESMs), and its diverse representations are a major source of the large spread across models in the terrestrial C sink from the third to fifth assessment reports of the Intergovernmental Panel on Climate Change (IPCC). Improving soil C projections is of a high priority for Earth system modeling in the future IPCC and other assessments. To achieve this goal, we suggest that (1) model structures should reflect real-world processes, (2) parameters should be calibrated to match model outputs with observations, and (3) external forcing variables should accurately prescribe the environmental conditions that soils experience. First, most soil C cycle models simulate C input from litter production and C release through decomposition. The latter process has traditionally been represented by first-order decay functions, regulated primarily by temperature, moisture, litter quality, and soil texture. While this formulation well captures macroscopic soil organic C (SOC) dynamics, better understanding is needed of their underlying mechanisms as related to microbial processes, depth-dependent environmental controls, and other processes that strongly affect soil C dynamics. Second, incomplete use of observations in model parameterization is a major cause of bias in soil C projections from ESMs. Optimal parameter calibration with both pool-and flux-based data sets through data assimilation is among the highest priorities for near-term research to reduce biases among ESMs. Third, external variables are represented inconsistently among ESMs, leading to differences in modeled soil C dynamics. Furthermore, we recommend the implementation of traceability analyses to identify how external variables and model parameterizations influence SOC dynamics in different ESMs. Overall, projections of the terrestrial C sink can be substantially improved when reliable data sets are available to select the most representative model structure, constrain parameters, and prescribe forcing fields.

54 ENVIRONMENTAL SCIENCES↗

Development of a Wide Range Segmented Gamma Scanner for Measuring Radioactive Wastes Arising in the Chinese Nuclear Industry - 16261

There is a requirement to measure a variety of challenging radioactive waste forms generated by the Chinese nuclear industry. These range from low activity waste to high activity waste with a high content of Cs-137 and waste in high density 200 litre drums. This paper describes the design, development and testing of an updated and automated Wide Range Segmented Gamma Scanner (WR-SGS) specifically configured for Chinese nuclear industry radioactive waste measuring requirements. The instrument retains the capabilities of the original SGS developed by Parker and Martin at the Los Alamos National Laboratory and now widely used for radioactive waste assay. It also incorporates additional features to improve measurement efficiency and reduce cost. These features include continuous helical scanning of the waste drum, and separate lifting pillars to lift the detector and the transmission source. In place of a transmission source shutter mechanism, the source is placed in a shielded safe when not in use. The design also incorporates a variable aperture collimator, and tungsten filters that can be deployed for the measurement of high activity, high dose-rate drums. Updated motion control electronics, based on the use of a programed logic controller have been incorporated to address potential future obsolescence. The WR-SGS employs a 40% high purity Germanium detector with electro-mechanical cooling and state of the art digital spectroscopy counting electronics for gamma ray spectrum data acquisition. Testing of the unit has been performed with both point sources and rod sources, which are traceable to international standards. Typical test drums, each with six distributed re-entrant tubes and with different density matrices, have been employed with the rod sources to validate both the calibration and the measurement performance of the WR-SGS for drums of different density. The measurement results have been compared with the reference decay corrected activity values and very good agreement is achieved, confirming the measurement performance of the instrument. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards direct realisation of the SI unit of sound pressure in the audible hearing range based on optical free-field acoustic particle measurements

Since the introduction of the International System of Units (the SI system) in 1960, weights, measures, standardised approaches, procedures, and protocols have been introduced, adapted, and extensively used. A major international effort and activity concentrate on the definition and traceability of the seven base SI units in terms of fundamental constants, and consequently those units that are derived from the base units. In airborne acoustical metrology and for the audible range of frequencies up to 20 kHz, the SI unit of sound pressure, the pascal, is realised indirectly and without any knowledge or measurement of the sound field. Though the principle of reciprocity was originally formulated by Lord Rayleigh nearly two centuries ago, it was devised in the 1940s and eventually became a calibration standard in the 1960s; however, it can only accommodate a limited number of acoustic sensors of specific types and dimensions. International standards determine the device sensitivity either through coupler or through free-field reciprocity but rely on the continuous availability of specific acoustical artefacts. Here, we show an optical method based on gated photon correlation spectroscopy that can measure sound pressures directly and absolutely in fully anechoic conditions, remotely, and without disturbing the propagating sound field. It neither relies on the availability or performance of any measurement artefact nor makes any assumptions of the device geometry and sound field characteristics. Most importantly, the required units of sound pressure and microphone sensitivity may now be experimentally realised, thus providing direct traceability to SI base units.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quality Assurance Protocol for AFCI Advanced Structural Materials Testing

The objective of this letter is to inform you of recent progress on the development of advanced structural materials in support of advanced fast reactors and AFCI. As you know, the alloy development effort has been initiated in recent months with the procurement of adequate quantities of the NF616 and HT-UPS alloys. As the test alloys become available in the coming days, mechanical testing, evaluation of optimizing treatments, and screening of environmental effects will be possible at a larger scale. It is therefore important to establish proper quality assurance protocols for this testing effort in a timely manner to ensure high technical quality throughout testing. A properly implemented quality assurance effort will also enable preliminary data taken in this effort to be qualified as NQA-1 during any subsequent licensing discussions for an advanced design or actual prototype. The objective of this report is to describe the quality assurance protocols that will be used for this effort. An essential first step in evaluating quality protocols is assessing the end use of the data. Currently, the advanced structural materials effort is part of a long-range, basic research and development effort and not, as yet, involved in licensing discussions for a specific reactor design. After consultation with Mark Vance (an ORNL QA expert) and based on the recently-issued AFCI QA requirements, the application of NQA-1 quality requirements will follow the guidance provided in Part IV, Subpart 4.2 of the NQA-1 standard (Guidance on Graded Application of QA for Nuclear-Related Research and Development). This guidance mandates the application of sound scientific methodology and a robust peer review process in all phases, allowing for the data to be qualified for use even if the programmatic mission changes to include licensing discussions of a specific design or prototype. ORNL has previously implemented a QA program dedicated to GNEP activities and based on an appropriately graded application of NQA-1 requirements at the site. The current program is being revised to incorporate changes imposed through the recently revised AFCI Technical Integration Office QA requirements. Testing conducted under the AFCI QA program for the advanced structural materials effort shall incorporate the following quality assurance expectations: (1) personnel are adequately trained to perform assigned work; (2) activities are controlled to ensure consistency of results; (3) records necessary to substantiate how the work was performed are maintained (dedicated laboratory notebooks will be used); (4) the pedigree and traceability of the various tested materials are maintained throughout the described processes using consistent sample numbering and adequate record keeping; (5) equipment with the potential to affect the quality of the planned work is calibrated and maintained in accordance with applicable operating requirements. In addition, all reporting or related dissemination by ORNL personnel of the results of the work described in this subcontract shall be conducted in accordance with the requirements described or referenced in the ORNL Standards Based Management System subject area entitled Scientific and Technical Information. Reporting or publications at other institutions will be conducted in accordance with the requirements of that institution. Successful implementation of these protocols will provide a sound basis for future decisions and research. In addition, these steps will also help ensure that results can also be applied to licensing discussions at a future date.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System for Measuring Flexing of a Large Spaceborne Structure

An optoelectronic metrology system is used for determining the attitude and flexing of a large spaceborne radar antenna or similar structure. The measurements are needed for accurate pointing of the antenna and correction and control of the phase of the radar signal wavefront. The system includes a dual-field-of-view star tracker; a laser ranging unit (LRU) and a position-sensitive-detector (PSD)-based camera mounted on an optical bench; and fiducial targets at various locations on the structure. The fiducial targets are illuminated in sequence by laser light coupled via optical fibers. The LRU and the PSD provide measurements of the position of each fiducial target in a reference frame attached to the optical bench. During routine operation, the star tracker utilizes one field of view and functions conventionally to determine the orientation of the optical bench. During operation in a calibration mode, the star tracker also utilizes its second field of view, which includes stars that are imaged alongside some of the fiducial targets in the PSD; in this mode, the PSD measurements are traceable to star measurements.

Scharf, Daniel↗

Reference Intercalibration for the Climate Observing System

Reference Intercalibration is critical in supporting the construction of climate data records, which, given their necessary longevity, must consist of measurements from multiple instruments. Reference intercalibration enables placing multiple instruments on the same radiometric scale, reducing calibration-based biases in climate data records. Measurements that have characteristics of a climate benchmark make excellent in-orbit intercalibration references. Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) consists of a reflected solar (RS) spectrometer (350-2300 nm) that will take hyperspectral Earth reflectance measurements with unprecedented SI-traceable accuracy (0.3%, 1-sigma) from the International Space Station (ISS). CPF measurements will have several characteristics of climate benchmark measurements and will demonstrate its capability as a rigorous in-orbit intercalibration reference with Clouds and Earth’s Radiant Energy System (CERES) and Visible Infrared Imaging Radiometer Suite (VIIRS). The methodologies that have been developed to support CPF-CERES and CPF-VIIRS intercalibration can readily be extended to other Low Earth Orbit and Geostationary instrument targets. With its highly accurate hyperspectral observations, CPF measurements can also be used to improve the characterization of targets widely used for satellite instrument vicarious calibration including Earth land surface pseudo-invariant calibration sites, deep convective clouds, and the Moon. We will discuss the importance of climate benchmark measurement attributes for intercalibration and considerations for the associated intercalibration data analysis to support building and maintaining climate data records.

Yolanda Shea↗

A radio telescope for the calibration of radio sources at 32 gigahertz

A 1.5-m-diameter radio telescope has been designed, developed, and assembled to directly measure the flux density of radio sources in the 32-GHz (Ka-band) frequency band. The main goal of the design and development was to provide a system that could yield the greatest absolute accuracy yet possible with such a system. The accuracy of the measurements have a heritage that is traceable to the National Institute of Standards and Technology. At the present time, the absolute accuracy of flux density measurements provided by this telescope system, during Venus observations at nearly closest approach to Earth, is plus or minus 5 percent, with an associated precision of plus or minus 2 percent. Combining a cooled high-electron mobility transistor low-noise amplifier, twin-beam Dicke switching antenna, and accurate positioning system resulted in a state-of-the-art system at 32 GHz. This article describes the design and performance of the system as it was delivered to the Owens Valley Radio Observatory to support direct calibrations of the strongest radio sources at Ka-band.

Gatti, M. S.↗

NREL Comparison of Absolute Cavity Pyrgeometers and Pyrgeometers Traceable to the World Infrared Standard Group and the Infrared Integrating Sphere: September 23-October 4, 2019

The comparison of the absolute cavity pyrgeometers (ACPs) with a precision infrared radiometer (PIR) pyrgeometer traceable to the World Infrared Standard Group (WISG) and a Kipp & Zonen (KZ) pyrgeometer traceable to WISG and the InfraRed Integrating Sphere Radiometer (IRIS) was held during the National Renewable Energy Laboratory (NREL) Pyrheliometer Comparison (NPC-2019) from September 23 to October 4, 2019. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs, PIR, and CG4 pyrgeometers collected 30 seconds during the measurement runs. The measurement runs lasted for two hours, while the calibration runs lasted for 6 minutes. During the comparison, the average (av) irradiance difference measured by three ACPs varied from 0.2 W/m 2 to 0.8 W/m 2 , with a standard deviation (sd) from 0.4 W/m 2 to 0.8 W/m 2 . The average irradiance difference measured by the three ACPs minus the irradiance measured by the PIR was 7.1 W/m 2 and sd 1.0 W/m 2 , and the average irradiance difference measured by the KZ traceable to WISG was 8.1 W/m2 and sd 0.9 W/m 2 , and average irradiance difference measured by the KZ traceable to IRIS was 4.0 W/m2 and sd 0.9 W/m 2 .

14 SOLAR ENERGY↗

CPF-VIIRS Intercalibration Methodology

NASA’s Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission will carry a high-accuracy reflected solar (RS) spectrometer to measure the Earth-reflected solar radiation from International Space Station with an SI-traceable radiometric uncertainty of 0.3% (1-sigma). The CPF measurements will serve as an on-orbit reference for intercalibrating other spaceflight RS instruments. The CPF intercalibration team has developed a state-of-the-art approach to calibrate the reflective solar bands (RSB) of the NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) sensor against the CPF benchmark measurements with an aimed intercalibration methodology uncertainty of 0.3%. This presentation will highlight the CPF mission overview and CPF-VIIRS intercalibration approach, as well as other potential outcomes of the CPF-VIIRS intercalibration study that may benefit the broader remote sensing community.

Raj Bhatt↗

Learning to Apply Metrology Principles to the Measurement of X-ray Intensities in the 500 eV to 110 keV Energy Range

National Security Technologies, LLC (NSTec), Livermore Operations, has two optical radiation calibration laboratories accredited by “the National Voluntary Laboratories Accreditation Program (NVLAP) which is the accrediting body of” the National Institute of Standards and Technology (NIST), and is now working towards accreditation for its X-ray laboratories. NSTec operates several laboratories with X-ray sources that generate X-rays in the energy range from 50 eV to 115 keV. These X-ray sources are used to characterize and calibrate diagnostics and diagnostic components used by the various national laboratories, particularly for plasma analysis on the Lawrence Livermore National Laboratory (LLNL) National Ignition Facility (NIF). Because X-ray photon flux measurement methods that can be accredited, i.e., traceable to NIST, have not been developed for sources operating in these energy ranges, NSTec, NIST, and the National Voluntary Accreditation Program (NVLAP) together have defined a path toward the development and validation of accredited metrology methods for X-ray energies. The methodology developed for the high energy X-ray (HEX) Laboratory was NSTec’s starting point for X-ray metrology accreditation and will be the basis for the accredited processes in the other X-ray laboratories. This paper will serve as a teaching tool, by way of this example using the NSTec X-ray sources, for the process and methods used in developing an accredited traceable metrology.

07 ISOTOPE AND RADIATION SOURCES↗

Arcjet Semi-Elliptic Nozzle Simulations and Validation in Support of TPS Testing

Much of the ground based testing of advanced thermal protection system (TPS) components for the X33 program is done in arc-heated wind tunnels such as those located in the Arc-Jet Complex at NASA Ames Research Center. These facilities are capable of simulating the high temperature, chemically reacting flow environment experienced by the vehicle during flight. This allows one to test critical design issues such as maximum reuse temperatures, seals, gaps, and increases in heating due to interfaces between different materials. Computational fluid dynamics (CFD) has evolved to the point where it now can be used in the vehicle design process for accurate and timely prediction of trajectory based aerothermal heating environments for re-entry vehicles. It can also be used for simulation of the flow environments in ground based facilities such as arcjets. By utilization of the same CFD code and solution methodology, the important differences between ground test and flight may be quantified. The goal of this paper is to utilize CFD to provide validated simulations of the flow environment in the NASA-Ames semi elliptic nozzle arcjet facilities. The validation of the ground simulations will come From comparison to existing calibration data. Specific tests in support of the X33 TPS test program will ilso be simulated. In this manner, the differences between the ground test simulation and the flight environment can be identified for a measure of ground test to flight traceability.

Loomis, Mark↗

Training and Validation of Spectral Gap Filling Algorithm for Cpf-Ceres Intercalibration

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission is set to launch an SI-traceable reflective solar (RS) spectrometer aboard the International Space Station to measure Earth-reflected solar radiation with a radiometric uncertainty of 0.3% (k=1). The CPF intercalibration team has devised a cutting-edge methodology to accurately transfer the benchmark CPF calibration reference to the shortwave (SW) channel (200-5000 nm) of the Clouds and the Earth’s Radiant Energy System (CERES) instrument. The spectral range of CPF measurements spans from 350-2300 nm, while the CERES SW channel measures the Earth-reflected broadband solar radiances between 200 nm to 5 μm. To conduct precise CPF-CERES intercalibration analysis, the CPF-like spectral radiances outside the CPF spectral range need to be estimated to match the CERES SW spectral range. In response, the team has developed a fast algorithm that leverages spectrally redundant information within the CPF-measured portion through principal component analysis (PCA) and utilizes pre-established spectral correlation relationships among wavelengths to extend the CPF spectrum below 350 nm and above 2300 nm. Our results show that the algorithm achieves excellent accuracy in generating the missing energy in the UV and IR portions. The RMS error in the UV region is less than 4.5x10-3 W/m2/sr/nm, while in the IR region, it is smaller than 8x10-5 W/m2/sr/nm. Our methodology was validated using measured EMIT radiance data, which covers the spectral range from 0.381 μm to 2.493 μm. We employed EMIT radiances within the wavelength range of 0.43 – 2.25 μm to generate radiances for both the shorter wavelength range (0.381 – 0.43 μm) and longer wavelength range (2.25 – 2.493 μm). The generated radiances agree very well with the measured EMIT radiances. The standard deviation in the integrated broadband radiances was about 0.1%, and the bias is less than 0.004% for over 1.5 million EMIT measured samples. These statistics show that the spectral gap filling algorithm is robust and effective in substantially reducing the spectral difference-induced uncertainty in the CPF-CERES intercalibration samples.

Qiguang Yang↗

CLARREO Pathfinder as a SI-traceable Reference for Satellite Intercalibration

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) consists of an Earthviewing reflected solar (RS) spectrometer that will measure the Earth-reflected solar radiation from International Space Station with an SI-traceable radiometric uncertainty of 0.3% (1-sigma). The high-accuracy CPF measurements will provide an in-orbit reference for intercalibrating other spaceflight RS instruments. The CPF intercalibration team has been tasked to develop a state-of-the-art approach to calibrate the shortwave channel (300-5000 nm) of the Clouds and the Earth’s Radiant Energy System (CERES) instrument and the reflective solar bands (RSB) of the Visible Infrared Imaging Radiometer Suite (VIIRS) instrument, both onboard the NOAA-20 satellite, against the CPF benchmark measurements. The aimed intercalibration methodology uncertainty for both the target instruments is also 0.3%. To meet this stringent intercalibration accuracy, the CPF team has developed methods for mitigating the impacts of spatial, spectral, and angular differences between the intercalibration footprints from the CPF and target instruments. To further alleviate uncertainty, the CPF team will employ Polarization Distribution Models (PDMs) to characterize the polarization state of the Earth-reflected radiance as a function of the intercalibration footprint scene type, solar and viewing geometry, and wavelength. The PDMs will assist in identifying low-polarized scene radiances for meticulously intercalibrating the polarization sensitive VIIRS instrument against the significantly-less polarization-sensitive CPF instrument. This paper will highlight the CPF mission overview, the details of the CPF intercalibration approach, and additional outcomes of the CPF intercalibration studies that may benefit the broader remote sensing community.community.

Hyperspectral↗

Multi-Angle Imager for Aerosols (MAIA) spectral and radiometric calibration

The Multi-angle Imaging SpectroRadiometer (MISR) was launched as part of NASA’s Terra satellite suite of instruments. Still operational, it makes use of observations from multiple view angles to retrieve aerosol abundance and particle properties. The Multi-Angle Imager for Aerosols (MAIA) instrument improves on this heritage by incorporating polarimetry and an expanded spectral range. Combining these data with surface measurements, the relationship between pollution and human health will be explored. MAIA has just completed camera testing, building on the experience from MISR. Spectral calibration now makes use of a double subtractive monochromator, built with the intent to allow the exit slit output to be uniform in spectral content. For radiometric testing, hardware upgrades have included adding UV lamps to the 1.65 cm (65") integrating sphere, use of a NIST-traceable sphere to establish absolute radiances, and the addition of a UV transfer spectrometer to support characterization of the sphere output from 300 to 2500 nm. During camera build, Newton’s rings were observed in the detector Quantum Efficiency (QE) measurements. This is due to etaloning within the detector itself. Etaloning was also evident in the spectral and radiometric characterizations performed on the completed camera. Spectral metrics, including center wavelength and width, are presented here using a moment’s analysis. This better represents the band properties, particularly in bands where fringing is observed, as compared to a full-width at half-maximum determination. It is believed that the MAIA camera has been carefully characterized, and meet its spectral and radiometric requirements.

Harten, Gerard Van↗

Achieving Climate Change Absolute Accuracy in Orbit

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

Wielicki, Bruce A.↗

REFSafE: A RAG-Enabled Framework for Predictive Risk Analysis and Automated Safety Report Generation in Mission-Critical Environments

Operational safety in mission-critical environments requires AI systems that are accurate, interpretable, and resistant to hallucination. We present an agentic Retrieval-Augmented Generation (RAG) framework, REFSafe, for grounded hazard analysis and automated safety report generation. The system integrates Large Language Models (LLMs) with structured operational data, historical incident repositories, policy documents, and external authoritative sources. Through iterative agentic reasoning, the framework retrieves, verifies, and synthesizes evidence prior to generation, enforcing citation-backed outputs with explicit source attribution (documents, links, and prior events) to ensure traceability and trust. To mitigate hallucinations and unsupported claims, all risk assessments and forecasts are constrained to retrieved evidence, with confidence signals derived from retrieval relevance and source consistency. A transparent pipeline enables subject matter experts (SMEs) to validate predictions, and provide structured feedback, forming a continuous performance calibration loop. Preliminary deployment demonstrates improved reliability in hazard detection and safety/vulnerability report generation. This work advances trustworthy, evidence-grounded AI for predictive safety intelligence in mission-critical operations.

Das, Sanjay [ORNL] (ORCID:0009000542591915)↗

Improving the longest SI traceable hyperspectral infrared record from space from the AIRS

The Atmospheric Infrared Sounder (AIRS) is a “facility” instrument developed by NASA as an experimental demonstration of advanced technology for remote sensing and the benefits of high resolution infrared spectra to weather forecasting and science investigations . It was launched into a 1:30 am/pm polar orbit on May 4, 2002 on the EOS Aqua Spacecraft, and is expected to provide highly calibrated data beyond 2024. AIRS has 2378 infrared channels ranging from 3.7 um to 15.4 um and a 13.5 km footprint. The AIRS data are used for weather forecasting, climate process studies and validating climate models. AIRS is a vital IR reference sensor for GSICS and is used by JMA for comparison to Himawari AHI , KMA for comparison to COMS , NOAA for comparison to CrIS and GOES , and EUMETSAT for comparison to IASI .

Strow, Larrabee↗

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

Purpose: To evaluate a prototype densitometer traceable to primary optical standards and compare its performance to an EPSON Expression{sup ®} 10000XL flatbed scanner (the Epson) for quantitative radiochromic film (RCF) dosimetry. Methods: A prototype traceable laser densitometry system (LDS) was developed to mitigate common film scanning artifacts, such as positional scan dependence and high noise in low-dose regions, by performing point-based measurements of RCF suspended in free-space using coherent light. The LDS and the Epson optical absorbance scales were calibrated up to 3 AU, using reference materials calibrated at a primary standards laboratory and a scanner calibration factor (SCF). Calibrated optical density (OD) was determined for 96 Gafchromic{sup ®} EBT3 film segments before and after irradiation to one of 16 dose levels between 0 and 10 Gy, exposed to {sup 60}Co in a polymethyl-methacrylate (PMMA) phantom. The sensitivity was determined at each dose level and at two rotationally orthogonal readout orientations to obtain the sensitometric response of each RCF dosimetry system. LDS rotational scanning dependence was measured at nine angles between 0°and 180°, due to the expected interference between coherent light and polarizing EBT3 material. The response curves were fit to the analytic functions predicted by two physical response models: the two-parameter single-hit model and the four-parameter percolation model. Results: The LDS and the Epson absorbance measurements were linear to primary optical standards to within 0.2% and 0.3% up to 2 and 1 AU, respectively. At higher densities, the LDS had an over-response (2.5% at 3 AU) and the Epson an under-response (3.1% and 9.8% at 2 and 3 AU, respectively). The LDS and the Epson SCF over the applicable range were 0.968% ± 0.2% and 1.561% ± 0.3%, respectively. The positional scan dependence was evaluated on each digitizer and shown to be mitigated on the LDS, as compared to the Epson. Maximum EBT3 rotational dependence was found to have a strong dependence on dose (0.1% and 34% at 30 mGy and 5 Gy, respectively). The preferred EBT3 polymerization axis angle was constant within experimental uncertainties. In its most sensitive orientation, the LDS-measured EBT3 sensitivity was 7.13 × 10{sup −4} ± 9.2 × 10{sup −6} AU/mGy, which represented a 4.5 fold increase over the Epson of 1.58 × 10{sup −4} ± 9.8 × 10{sup −6} AU/mGy. To first order approximations, EBT3 response was linear up to 500 mGy to within 0.80% and to within 7.5% for the most sensitive LDS and the Epson orientations, respectively. The corresponding single-hit and percolation model relative residual norms were 0.082 and 0.074 for LDS as compared to 0.29 and 0.18 for the Epson, which represented a significant increase in LDS-measured agreement with the simple physical model. Less sensitive LDS and the Epson orientations showed a marked decrease in the physical model agreement, which suggested that suboptimal readout device characteristics may be the origin of the complex sensitometric functional forms currently required for accurate RCF dosimetry. Conclusions: The prototype densitometer was shown to be superior to a conventional scanner for quantitative RCF dosimetry based on physical models of film response. The Epson was shown to be a reliable tool for routine RCF dosimetry in a clinical setting, yet calibration to primary optical standards did not mitigate the necessity for complex, empirical functional form fitting.

60 APPLIED LIFE SCIENCES↗