At least 325 records · Page 18

Method to provide meta-stable operation of a DC microgrid comprising a pulsed load

A Hamiltonian surface shaping power flow control (HSSPFC) method is used to analyze the meta-stability and adjust pulsed power loads on a DC electric power distribution network. Pulsed power loads are nonlinear, time-variant systems that cause nonlinear limit-cycles. During the on periods of a pulsed load, the system can be in an unstable state and is damped back to stability during the off state of the load. Therefore, over the entire period of the pulse the system may only be assessed as meta-stable. As shown through simulation, HIL and hardware results, the HSSPFC method is more accurate than the other small-signal approaches, such as Eigenvalues, Nyquist, and Floquet theory, and can reveal important details about the transient responses and performance.

Wilson, David G.↗

In-Flight Validation of a Pilot Rating Scale for Evaluating Failure Transients in Electronic Flight Control Systems

Engineering development and qualification of a Research Flight Control System (RFCS) for the Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) JUH-60A has motivated the development of a pilot rating scale for evaluating failure transients in fly-by-wire flight control systems. The RASCAL RFCS includes a highly-reliable, dual-channel Servo Control Unit (SCU) to command and monitor the performance of the fly-by-wire actuators and protect against the effects of erroneous commands from the flexible, but single-thread Flight Control Computer. During the design phase of the RFCS, two piloted simulations were conducted on the Ames Research Center Vertical Motion Simulator (VMS) to help define the required performance characteristics of the safety monitoring algorithms in the SCU. Simulated failures, including hard-over and slow-over commands, were injected into the command path, and the aircraft response and safety monitor performance were evaluated. A subjective Failure/Recovery Rating (F/RR) scale was developed as a means of quantifying the effects of the injected failures on the aircraft state and the degree of pilot effort required to safely recover the aircraft. A brief evaluation of the rating scale was also conducted on the Army/NASA CH-47B variable stability helicopter to confirm that the rating scale was likely to be equally applicable to in-flight evaluations. Following the initial research flight qualification of the RFCS in 2002, a flight test effort was begun to validate the performance of the safety monitors and to validate their design for the safe conduct of research flight testing. Simulated failures were injected into the SCU, and the F/RR scale was applied to assess the results. The results validate the performance of the monitors, and indicate that the Failure/Recovery Rating scale is a very useful tool for evaluating failure transients in fly-by-wire flight control systems.

Kalinowski, Kevin F.↗

The Effect of Normal Stress Oscillations on Fault Slip Behavior Near the Stability Transition From Stable to Unstable Motion

Tectonic fault zones are subject to normal stress variations with a wide range of spatio-temporal scales. Stress perturbations cover a wide range of frequencies and amplitudes from high frequency seismic waves generated by earthquakes to low frequency transients associated with solid Earth tides. These perturbations can reactivate critically stressed faults and trigger earthquakes. Here, we describe lab experiments to illuminate the physics of such changes in friction and the mechanics of earthquake triggering and fault reactivation. Friction tests were done in a double direct shear configuration for conditions near the stability transition from stable to unstable motion. We studied simulated fault gouge composed of quartz powder and conducted experiments at reference normal stress from 10 to 13.5 MPa. After shearing to steady state sliding, we applied sinusoidal normal stress oscillations of amplitude 0.5–2 MPa, and period of 0.5–50 s. We performed numerical simulations using measured values of rate and state friction (RSF) parameters to assess our data. Our results show that low frequency stress oscillations cause a Coulomb-like response of shear strength that transitions from stable slip to slow lab earthquakes as frequency increases. At the critical frequency predicted by RSF we observe periodic stick-slip behavior. Perturbations of high amplitude and short period weaken the fault, while lower amplitudes strengthen the fault. We find that a modified RSF formulation is able to accurately match our laboratory data. Our findings highlight the complex effects of stress perturbations on fault strength and the mode of fault slip.

58 GEOSCIENCES↗

Pressure stability in explicitly coupled simulations of poromechanics with application to CO 2 sequestration

We study in detail the pressure stabilizing effects of the non-iterated fixed-stress splitting in poromechanical problems which are nearly undrained and incompressible. When applied in conjunction with a spatial discretization which does not satisfy the discrete inf–sup condition, namely a mixed piecewise linear–piecewise constant spatial discretization, the explicit fixed-stress scheme can have a pressure stabilizing effect in transient problems. This effect disappears, however, upon time step refinement or the attainment of steady state. The interpretation of the scheme as an Augmented Lagrangian method similar to Uzawa iteration for incompressible flow helps explain these results. Moreover, due to the slowly evolving solution within undrained seal regions, we show that the explicit fixed-stress scheme requires very large time steps to reveal its pressure stabilizing effect in examples of geologic CO 2 sequestration. We note that large time steps can result in large errors in drained regions, such as the aquifer or reservoir regions of these examples, and can prevent convergence of nonlinear solvers in the case of multiphase flows, which can make the explicit scheme an unreliable source of pressure stabilization. We conclude by demonstrating that pressure jump stabilization is as effective in the explicit fixed-stress setting as in the fully implicit setting for undrained problems, while maintaining the stability and convergence of the fixed-stress split for drained problems.

58 GEOSCIENCES↗

Hyper-fidelity depletion coupled with discrete pebble motion in pebble bed reactors

Pebble bed reactors have raised new interest during the past decade due to their attractive characteristics. Therefore, accurate simulations must be performed to better understand these systems and ensure optimal and safe designs. Most current methods use lower fidelity approaches with representative unit-cells or macro-zones with uniform fluxes, which have accuracy and flexibility limitations. A novel hyper-fidelity method for pebble bed reactors depletion is presented and internally couples Serpent 2 and a pseudo-motion routine. Pseudo-motion is applied handling vertical shifts of compositions in a static pebble bed, random reinsertion of used pebbles, insertion of fresh pebbles and used pebbles discarding. Associated with individual depletion to correctly determine the flux spectrum and composition in each pebble, this hyper-fidelity approach paves the way towards more accurate depletion calculation in pebble bed reactors. Using this method, a demonstration is completed on a small-scale reactor. In this application, the core reaches equilibrium, and the following data is extracted: core-wise parameters evolution, pebble-wise spatial and statistical distribution. Discarded pebbles are analyzed, and relevant information is shown. This work proves the feasibility of hyper fidelity depletion with Serpent 2, and the range of use for this method: reactor design and analysis for equilibrium and slow transients, lower fidelity methods validation and feeding fuel performance, thermal-hydraulics, or waste management models. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electron Injection from Copper Diimine Sensitizers into TiO 2 : Structural Effects and Their Implications for Solar Energy Conversion Devices

Copper(I) diimine complexes have emerged as low cost replacements for ruthenium complexes as light sensitizers and electron donors, but their shorter metal-to-ligand-charge-transfer (MLCT) states lifetimes and lability of transient Cu(II) species impede their intended functions. Two carboxylated Cu(I) bis-2,9-diphenylphenanthroline (dpp) complexes [Cu(I)(dpp-O(CH2CH2O)(5))(dpp-(COOH)(2))](+) and [Cu(I)(dpp-O(CH2CH2O)(5))(dpp-(F-COOH)(2))](+) (F = tolyl) with different linker lengths were synthesized in which the MLCT-state solvent quenching pathways are effectively blocked, the lifetime of the singlet MLCT state is prolonged, and the transient Cu(II) ligands are stabilized. Aiming at understanding the mechanisms of structural influence to the interfacial charge transfer in the dye-sensitized solar cell mimics, electronic and geometric structures as well as dynamics for the MLCT state of these complexes and their hybrid with TiO2 nanoparticles were investigated using optical transient spectroscopy, X-ray transient absorption spectroscopy, time-dependent density functional theory, and quantum dynamics simulations. The combined results show that these complexes exhibit strong absorption throughout the visible spectrum due to the severely flattened ground state, and a long-lived charge-separated Cu(II) has been achieved via ultrafast electron injection (<300 fs) from the 1MLCT state into TiO2 nanoparticles. The results also indicate that the TiO2-phen distance in these systems does not have significant effect on the efficiency of the interfacial electron-transfer process. The mechanisms for electron transfer in these systems are discussed and used to develop new strategies in optimizing copper(I) diimine complexes in solar energy conversion devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Cause of Insufficient Damping in Phase-Locked-Loop and Its Influence

Phase-locked loop (PLL) is a critical component that synchronizes grid-following (GFL) inverter-based resources (IBR) to the grid. Insufficient damping in PLL has been identified as a cause associated with real-world weak grid stability issues. This paper reveals that the second-order low-pass filter deployed in a sophisticated PLL structure can have negative influence on damping performance and lead to system instability when the grid is weak and power generation is low. Improving the PLL damping is illustrated as one of the mitigation approaches. The dynamic study is carried out in electromagnetic transient (EMT) simulation environment. In addition to EMT demonstration, a simplified analytical model of PLL is developed to represent a PLL with the sophisticated structure. The resulting overall analytical model of the entire system is then used for eigenvalue- based analysis to illustrate the influence of PLL on dynamic modes.

Wang, Zhengyu↗

Seamless Transition of Critical Infrastructures using Droop Controlled Grid-forming Inverters

Seamless recovery of power to critical infrastructures, after grid failure, is a crucial need arising in scenarios that are increasingly becoming more frequent. Here, this article proposes a seamless transition strategy using a single and unified mode-dependent droop controlled grid-forming inverters. The control strategy achieves the following objectives: 1) regulates the output active and reactive power by the droop-controlled inverters to a desired value while operating in on-grid mode; 2) seamless transition and recovery of power injections into the load after grid failure by inverters that operates in grid-forming mode all the time; 3) requires only a single bit of information on the grid/network status for the mode transition. A framework for assessing the stability of the system and to guide the choice of parameters for controllers is developed using control-oriented modeling. A controller hardware-in-the-loop-based real-time simulation study on a test system based on the realistic electrical network of a commercial-scale medical center is conducted for initial prototyping of the control strategy. A hardware experiment is conducted with two 3 - $\phi$, 480 -V, 125 -kVA grid-forming inverters, a 3 - $\phi$, 480 -V, 270 -kVA grid simulator, a physical grid switch, and a physical load bank. The experimental data establishes the effectiveness of the always grid-forming operation and control of inverters in meeting power delivery objectives when on-grid and off-grid under various kinds of loads and scenarios while minimizing transients during transitions. Furthermore, performance comparison with existing strategies showcases the advantage of the proposed strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The denatured state of HIV ‐1 protease under native conditions

Abstract The denatured state of several proteins has been shown to display transient structures that are relevant for folding, stability, and aggregation. To detect them by nuclear magnetic resonance (NMR) spectroscopy, the denatured state must be stabilized by chemical agents or changes in temperature. This makes the environment different from that experienced in biologically relevant processes. Using high‐resolution heteronuclear NMR spectroscopy, we have characterized several denatured states of a monomeric variant of HIV‐1 protease, which is natively structured in water, induced by different concentrations of urea, guanidinium chloride, and acetic acid. We have extrapolated the chemical shifts and the relaxation parameters to the denaturant‐free denatured state at native conditions, showing that they converge to the same values. Subsequently, we characterized the conformational properties of this biologically relevant denatured state under native conditions by advanced molecular dynamics simulations and validated the results by comparison to experimental data. We show that the denatured state of HIV‐1 protease under native conditions displays rich patterns of transient native and non‐native structures, which could be of relevance to its guidance through a complex folding process.

60 APPLIED LIFE SCIENCES↗

An adaptive DC-bus stabilizer for single-phase grid-connected renewable energy source system

This paper proposes an adaptive DC-bus stabilizer for single-phase grid-connected voltage source converter (VSC) with small-scale renewable energy integration. To enhance converter's power density, the conventional active power decoupling (APD) techniques were adopted to reduce the DC capacitance by compensating the inherent second-order harmonic power ripples in the single-phase VSC. However, it would potentially make the DC voltage vulnerable to transient power ripples, which is a critical issue for the grid-connected renewable energy source (RES) system during grid faults. The proposed DC-bus stabilizer can not only compensate the second-order harmonic power ripples at normal operation, but also enhance the fault ride-through capability of the converter. The circuit topology and its corresponding control strategy are presented, and then simulation results are provided to demonstrate the feasibility and validity of the proposed DC-bus stabilizer under normal operation and grid fault condition.

Zeng, Rong↗

Hydroxide films on mica form charge-stabilized microphases that circumvent nucleation barriers

Crystal nucleation is facilitated by transient, nanoscale fluctuations that are extraordinarily difficult to observe. Here, we use high-speed atomic force microscopy to directly observe the growth of an aluminum hydroxide film from an aqueous solution and characterize the dynamically fluctuating nanostructures that precede its formation. Nanoscale cluster distributions and fluctuation dynamics show many similarities to the predictions of classical nucleation theory, but the cluster energy landscape deviates from classical expectations. Kinetic Monte Carlo simulations show that these deviations can arise from electrostatic interactions between the clusters and the underlying substrate, which drive microphase separation to create a nanostructured surface phase. This phase can evolve seamlessly from a low-coverage state of fluctuating clusters into a high-coverage nanostructured network, allowing the film to grow without having to overcome classical nucleation barriers.

36 MATERIALS SCIENCE↗

Effects of confinement on partially premixed flames

Partially premixed combustion is an intermediate regime between the limiting cases of premixed and nonpremixed combustion. Although combustion problems are generally approached from one of these two limiting cases, there are many practical situations where flames cannot be considered as purely premixed or nonpremixed, and thus the partially premixed approach must be used. In partially premixed combustion, mechanisms from the premixed and nonpremixed regimes can coexist, and as a result some interesting new phenomena can arise. One such phenomenon is the flame stabilization in laminar mixing layers by triple flames. One of the first observations of triple flames was made by Phillips (1965), who investigated a triple flame propagating in a methane mixing layer. Kioni et al. (1993) also examined triple flames both experimentally and numerically. There have also been numerous analytical studies on the shape and propagation of triple flames under various assumptions by Dold (1989), Dold et al. (1991), and Hartley and Dold (1991). In terms of modeling, Muller et al. (1994) have combined the flamelet formulations for premixed and nonpremixed combustion in order to treat lifted diffusion flames. One common feature in the analytical and numerical studies mentioned above is the assumption of zero heat release, which is necessary to make the problem tractable. The effect of heat release on triple flames was investigated by Ruetsch et al. (1995), where for the unconfined case, flame speeds larger than their premixed counterparts were found. One of the most important practical situations in which these conditions arise is in lifted turbulent jet diffusion flames. At a critical velocity the burning zone of a fuel jet lifts off from the nozzle, moves to increasing distances as the jet velocity increases, and finally blows off. The mechanisms that control these phenomena, i.e. that determine the stability of these flames, are still not understood. In addition to regions where diffusion flame stabilization takes place, partially premixed conditions also exist during the ignition process in nonpremixed systems. Numerical simulations by Reveillon et al. (1994) of the ignition process in a weakly stirred mixture of fuel and oxidizer show that triple flames propagate along lines of stoichiometric mixture fraction throughout the fluid. In addition, Peters (1994) notes that NO(x) emissions are likely to be large in such transient cases, and therefore an understanding of triple flames can provide information concerning pollutant formation. This study extends the work previously done and examines the effects of lateral confinement on partially premixed flames. Once again, we study both the flame structure and propagation.

Ruetsch, G. R.↗

Optical Modeling Activities for NASA's James Webb Space Telescope (JWST): V. Operational Alignment Updates

This paper is part five of a series on the ongoing optical modeling activities for the James Webb Space Telescope (JWST). The first two papers discussed modeling JWST on-orbit performance using wavefront sensitivities to predict line of sight motion induced blur, and stability during thermal transients. The third paper investigates the aberrations resulting from alignment and figure compensation of the controllable degrees of freedom (primary and secondary mirrors), which may be encountered during ground alignment and on-orbit commissioning of the observatory, and the fourth introduced the software toolkits used to perform much of the optical analysis for JWST. The work here models observatory operations by simulating line-of-sight image motion and alignment drifts over a two-week period. Alignment updates are then simulated using wavefront sensing and control processes to calculate and perform the corrections. A single model environment in Matlab is used for evaluating the predicted performance of the observatory during these operations.

Howard, Joseph M.↗

SIGNIFICANT X-RAY LINE EMISSION IN THE 5-6 keV BAND OF NGC 4051

A Suzaku X-ray observation of NGC 4051 taken during 2005 November reveals line emission at 5.44 keV in the rest frame of the galaxy which does not have an obvious origin in known rest-frame atomic transitions. The improvement to the fit statistic when this line is accounted for establishes its reality at >99.9% confidence: we have also verified that the line is detected in the three X-ray Imaging Spectrometer units independently. Comparison between the data and Monte Carlo simulations shows that the probability of the line being a statistical fluctuation is p < 3.3 x 10{sup -4}. Consideration of three independent line detections in Suzaku data taken at different epochs yields a probability p < 3 x 10{sup -11} and thus conclusively demonstrates that it cannot be a statistical fluctuation in the data. The new line and a strong component of Fe Kalpha emission from neutral material are prominent when the source flux is low, during 2005. Spectra from 2008 show evidence for a line consistent with having the same flux and energy as that observed during 2005, but inconsistent with having a constant equivalent width against the observed continuum. The stability of the line flux and energy suggests that it may not arise in transient hotspots, as has been suggested for similar lines in other sources, but could arise from a special location in the reprocessor, such as the inner edge of the accretion disk. Alternatively, the line energy may be explained by spallation of Fe into Cr, as discussed in a companion paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital quantum magnetism on a trapped-ion quantum computer

Digital quantum matter—realized when discrete quantum gates approximate continuous time evolution—is susceptible to heating into chaotic, structureless states. If digitization errors are adequately suppressed, a long-lived transient regime of approximately energy-conserving dynamics can be observed on gate-based quantum computers. Conservation of energy, in turn, enables the exploration of a wide variety of complex behaviours observed in equilibrium systems, ranging from the non-trivial microscopic origins of thermalization itself to the stabilization of effective models hosting exotic emergent properties. Here we use Quantinuum’s H2 quantum computer to simulate digitized dynamics of the quantum Ising model, suppressing digitization errors well enough to observe thermalization on timescales that severely challenge classical simulation methods. Relaxation of an inhomogeneous state reveals an emergent hydrodynamics owing to approximate energy conservation and we compute the associated diffusion constant. By reprogramming our simulations to take place on a triangular lattice with periodic boundary conditions, we observe thermalization consistent with emergent gauge and topological constraints resulting from lattice frustration. Furthermore, our results were enabled by continued advances in two-qubit gate quality (native partial entangler fidelities of 99.94(1)%) and establish digital quantum computers as powerful tools for studying (effectively) continuous-time dynamics.

Information theory and computation↗

Long-term Evolution of Upper Stratospheric Ozone at Selected Stations of the Network for the Detection of Stratospheric Change (NDSC)

The long-term evolution of upper stratospheric ozone has been recorded by lidars and microwave radiometers within the ground-based Network for the Detection of Stratospheric Change (NDSC), and by the space-borne Solar Backscatter Ultra-Violet instruments (SBUV), Stratospheric Aerosol and Gas Experiment (SAGE), and Halogen Occultation Experiment (HALOE). Climatological mean differences between these instruments are typically smaller than 5% between 25 and 50 km. Ozone anomaly time series from all instruments, averaged from 35 to 45 km altitude, track each other very well and typically agree within 3 to 5%. SBUV seems to have a slight positive drift against the other instruments. The corresponding 1979 to 1999 period from a transient simulation by the fully coupled MAECHAM4-CHEM chemistry climate model reproduces many features of the observed anomalies. However, in the upper stratosphere the model shows too low ozone values and too negative ozone trends, probably due to an underestimation of methane and a consequent overestimation of ClO. The combination of all observational data sets provides a very consistent picture, with a long-term stability of 2% or better. Upper stratospheric ozone shows three main features: (1) a decline by 10 to 15% since 1980, due to chemical destruction by chlorine; (2) two to three year fluctuations by 5 to 10%, due to the Quasi-Biennial Oscillation (QBO); (3) an 11-year oscillation by about 5%, due to the 11-year solar cycle. The 1979 to 1997 ozone trends are larger at the southern mid-latitude station Lauder (45 S), reaching 8%/decade, compared to only about 6%/decade at Table Mountain (35 N), Haute Provence/Bordeaux (approximately equal to 45 N), and Hohenpeissenberg/Bern(approximately equal to 47 N). At Lauder, Hawaii (20 N), Table Mountain, and Haute Provence, ozone residuals after subtraction of QBO- and solar cycle effects have levelled off in recent years, or are even increasing. Assuming a turning point in January 1997, the change of trend is largest at southern mid-latitude Lauder, +11%/decade, compared to +7%/decade at northern mid-latitudes. This points to a beginning recovery of upper stratospheric ozone. However, chlorine levels are still very high and ozone will remain vulnerable. At this point the most northerly mid-latitude station, Hohenpeissenberg/Bern differs from the other stations, and shows much less clear evidence for a beginning recovery, with a change of trend in 1997 by only +3%/decade. In fact, record low upper stratospheric ozone values were observed at Hohenpeissenberg/Bern, and to a lesser degree at Table Mountain and Haute Provence, in the winters 2003/2004 and 2004/2005.

Steinbrecht, W.↗

MULTIPHYSICS STEADY-STATE SIMULATION OF THE HIGH TEMPERATURE TEST REACTOR WITH MAMMOTH, BISON AND RELAP-7

In this work we present a new approach to solving a multiphysics steady-state simulation for the High Temperature Test Reactor (HTTR) using one Super Homogenization (SPH) corrected homogenized 3-D neutronics model in MAMMOTH, multiple heterogeneous 2-D axisymmetric fuel pin models in BISON and several 1-D annular flow thermohydraulics models in RELAP-7. The coupling of the different physics is complicated by the fundamentally disparate models, potentially affecting the stability of the global system. A pseudo-transient to converge the temperature fields is used to circumvent this difficulty. The benefit of doing so as opposed to having fully 3-D heterogenous models for all physics is that the computational burden for reactors as complex as HTTR may quickly become unbearable while coarse models may not capture all the essential phenomena of the problem. The driving purpose of this work is to establish a self-sustaining steady-state solution that can be used to start safety transients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MULTIPHYSICS STEADY-STATE SIMULATION OF THE HIGH TEMPERATURE TEST REACTOR WITH MAMMOTH, BISON AND RELAP-7

In this work we present a new approach to solving a multiphysics steady-state simulation for the High Temperature Test Reactor (HTTR) using one Super Homogenization (SPH) corrected homogenized 3-D neutronics model in MAMMOTH, multiple heterogeneous 2-D axisymmetric fuel pin models in BISON and several 1-D annular flow thermohydraulics models in RELAP-7. The coupling of the different physics is complicated by the fundamentally disparate models, potentially affecting the stability of the global system. A pseudo-transient to converge the temperature fields is used to circumvent this difficulty. The benefit of doing so as opposed to having fully 3-D heterogenous models for all physics is that the computational burden for reactors as complex as HTTR may quickly become unbearable while coarse models may not capture all the essential phenomena of the problem. The driving purpose of this work is to establish a self-sustaining steady-state solution that can be used to start safety transients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗