Search NASA⌕ Search

SEARCH · Search NASA

Results for “variability analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Spacesuit Glove-Induced Hand Trauma and Analysis of Potentially Related Risk Variables

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. Glove injuries, both anecdotal and recorded, have been reported during EVA training and flight persistently through NASA's history regardless of mission or glove model. Theories as to causation such as glove-hand fit are common but often lacking in supporting evidence. Previous statistical analysis has evaluated onycholysis in the context of crew anthropometry only (Opperman et al 2010). The purpose of this study was to analyze all injuries (as documented in the medical records) and available risk factor variables with the goal to determine engineering and operational controls that may reduce hand injuries due to the EVA glove in the future. A literature review and data mining study were conducted between 2012 and 2014. This study included 179 US NASA crew who trained or completed an EVA between 1981 and 2010 (crossing both Shuttle and ISS eras) and wore either the 4000 Series or Phase VI glove during Extravehicular Mobility Unit (EMU) spacesuit EVA training and flight. All injuries recorded in medical records were analyzed in their association to candidate risk factor variables. Those risk factor variables included demographic characteristics, hand anthropometry, glove fit characteristics, and training/EVA characteristics. Utilizing literature, medical records and anecdotal causation comments recorded in crewmember injury data, investigators were able to identify several risk factors associated with increased risk of glove related injuries. Prime among them were smaller hand anthropometry, duration of individual suited exposures, and improper glove-hand fit as calculated by the difference in the anthropometry middle finger length compared to the baseline EVA glove middle finger length.

McFarland, Shane M.↗

Mesospheric ozone changes associated with 27-day solar ultraviolet flux variations

Solar ultraviolet flux changes associated with the 27-day solar rotational period cause corresponding variations in mesospheric ozone near the maximum of the 11-year sunspot cycle. This statement is based on a correlation and spectral analysis of ozone mixing ratios, deduced from Solar Mesospheric explorer satellite-based measurements of 1.27-micron O2 airglow emission and solar flux observations made from the same spacecraft in 1982. With the Lyman-alpha flux taken as an indicator of solar ultraviolet variability, spectral analysis shows a primary period of 27.1 days with a secondary period of 13.5 days. The 27.1-day period is observed in the ozone mixing ratio data together with other periods, including 13.5 days. Both a classical statistical analysis and a time series treatment show that, for 244 days, there is a correlation between ozone and solar flux near 50 km and between 65 and 70 km. Calculations predict a positive correlation over the entire mesosphere if there is no change in temperature accompanying the solar flux. Lack of correlation is temperature induced.

Aikin, A. C.↗

Variability in Automated Responses of Commercial Buildings and Industrial Facilities to Dynamic Electricity Prices

Changes in the electricity consumption of commercial buildings and industrial facilities (C&I facilities) during Demand Response (DR) events are usually estimated using counterfactual baseline models. Model error makes it difficult to precisely quantify these changes in consumption and understand if C&I facilities exhibit event-to-event variability in their response to DR signals. This paper seeks to understand baseline model error and DR variability in C&I facilities facing dynamic electricity prices. Using a regression-based baseline model, we present a method to compute the error associated with estimates of several DR parameters. We also develop a metric to determine how much observed DR variability results from baseline model error rather than real variability in response. We analyze 38 C&I facilities participating in an automated DR program and find that DR parameter errors are large. Though some facilities exhibit real DR variability, most observed variability results from baseline model error. Therefore, facilities with variable DR parameters may actually respond consistently from event to event. Consequently, in DR programs in which repeatability is valued, individual buildings may be performing better than previously thought. In some cases, however, aggregations of C&I facilities exhibit real DR variability, which could create challenges for power system operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

VARIABLE REDDENING AND BROAD ABSORPTION LINES IN THE NARROW-LINE SEYFERT 1 GALAXY WPVS 007: AN ORIGIN IN THE TORUS

We report the discovery of an occultation event in the low-luminosity narrow-line Seyfert 1 galaxy WPVS 007 in 2015 February and March. In concert with longer timescale variability, these observations place strong constraints on the nature and location of the absorbing material. Swift monitoring has revealed a secular decrease since ∼2010 accompanied by flattening of the optical and UV photometry that suggests variable reddening. Analysis of four Hubble Space Telescope COS observations since 2010, including a Director’s Discretionary time observation during the occultation, shows that the broad-absorption-line velocity offset and the C iv emission-line width both decrease as the reddening increases. The occultation dynamical timescale, the BAL variability dynamical timescale, and the density of the BAL gas show that both the reddening material and the broad-absorption-line gas are consistent with an origin in the torus. These observations can be explained by a scenario in which the torus is clumpy with variable scale height, and the BAL gas is blown from the torus material like spray from the crest of a wave. As the obscuring material passes into our line of sight, we alternately see high-velocity broad absorption lines and a clear view to the central engine, or low-velocity broad absorption lines and strong reddening. WPVS 007 has a small black hole mass, and correspondingly short timescales, and so we may be observing behavior that is common in BALQSOs, but is not typically observable.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Autoconversion Representation in E3SMv2 Using an Ensemble of Large-Eddy Simulations of Low-Level Warm Clouds

In numerical atmospheric models that treat cloud and rain droplet populations as separate condensate categories, precipitation initiation in warm clouds is often represented by an autoconversion rate (Au), which is the rate of formation of new rain droplets through the collisions of cloud droplets. Being a function of the cloud droplet size distribution (DSD), the local Au is commonly parameterized as a function of DSD moments: cloud droplet number (n c ) and mass (q c ) concentrations. When applied in a large-scale model, the grid-mean Au must also include a correction, or enhancement factor, to account for the horizontal variability of the cloud properties across the model grid. In this study, we evaluate the Au representation in the Energy Exascale Earth System Model version 2 (E3SMv2) climate model using large-eddy simulations (LES), which explicitly resolve cloud droplet spectra, and therefore the local Au, as well as its spatial variability. The analysis of an ensemble of warm low-level cloud cases shows that the E3SMv2 formulation represents the Au reasonably well compared to the horizontally averaged explicitly computed rate from LES. The agreement, however, comes from a combination of an underestimated E3SM-tuned local Au rate and an overestimated subgrid cloud variability enhancement factor. The latter bias is traced to neglecting the horizontal variability of n c and its co-variability with q c in parameterizing the grid-mean Au.

54 ENVIRONMENTAL SCIENCES↗

The effects of temperature and frequencies in ultrasound assisted extraction of phycocyanin from microalgae Spirulina sp

Microalgae Spirulina sp has been identified as source of protein and other high added value compounds. One of the compounds is phycocyanin as also known for antioxidant use. The extraction of this compound by using conventional method (soxhlet extraction) resulted low yield and longer processing time. This research was aimed to extract phycocyanin by using an extraction assisted by ultrasound irradiation. The extraction was performed by using variable of ultrasound frequency and extraction temperature and ethanol was used as a solvent. The result showed that yield of phycocyanin extracted by conventional method was 11.13% while the ultrasound irradiation could increase the yield up to 15.61% at constant frequency of 42 kHz, while the optimum temperature was obtained at 45°C. The analysis of variable interactions showed that both temperature and time has an interaction and temperature was the highest variable in increasing the yield. The conclusion of this research was the ultrasound could improve significantly the efficiency of extraction as well as activity of phycocyanin extracted from microalgae.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multivariable Parametric Cost Model for Ground Optical: Telescope Assembly

A parametric cost model for ground-based telescopes is developed using multi-variable statistical analysis of both engineering and performance parameters. While diameter continues to be the dominant cost driver, diffraction limited wavelength is found to be a secondary driver. Other parameters such as radius of curvature were examined. The model includes an explicit factor for primary mirror segmentation and/or duplication (i.e. multi-telescope phased-array systems). Additionally, single variable models based on aperture diameter were derived.

Stahl, H. Philip↗

A CENSUS OF ROTATION AND VARIABILITY IN L1495: A UNIFORM ANALYSIS OF TRANS-ATLANTIC EXOPLANET SURVEY LIGHT CURVES FOR PRE-MAIN-SEQUENCE STARS IN TAURUS

We analyze light curves obtained by the Trans-atlantic Exoplanet Survey (TrES) for a field centered on the L1495 dark cloud in Taurus. The Spitzer Taurus Legacy Survey catalog identifies 179 bona fide Taurus members within the TrES field; 48 of the known Taurus members are detected by TrES, as well as 26 candidate members identified by the Spitzer Legacy team. We quantify the variability of each star in our sample using the ratio of the standard deviation of the original light curve ({sigma}{sub orig.}) to the standard deviation of a light curve that has been smoothed by 9 or 1001 epochs ({sigma}{sub 9} and {sigma}{sub 1001}, respectively). Known Taurus members typically demonstrate ({sigma}{sub orig.}/{sigma}{sub 9}) < 2.0, and ({sigma}{sub orig.}/{sigma}{sub 1001}) < 5, while field stars reveal ({sigma}{sub orig.}/{sigma}{sub 9}) {approx} 3.0 and ({sigma}{sub orig.}/{sigma}{sub 1001}) {approx} 10, as expected for light curves dominated by unstructured white noise. Of the 74 Taurus members/candidates with TrES light curves, we detect significant variability in 49 sources. Adapting a quantitative metric originally developed to assess the reliability of transit detections, we measure the amount of red and white noise in each light curve and identify 18 known or candidate Taurus members with highly significant period measurements. These appear to be the first periods measured for four of these sources (HD 282276, CX Tau, FP Tau, TrES J042423+265008), and in two other cases, the first non-aliased periods (LkCa 21 and DK Tau AB). For the remainder, the TrES measurements typically agree very well ({delta}P < 1%) with previously reported values. Including periods measured at lower confidence for 15 additional sources, we report periods for 11 objects where no previous periods were found, including 8 confirmed Taurus members. We also identify 10 of the 26 candidate Taurus members that demonstrate variability levels consistent with being bona fide T Tauri stars. A Kolomgorov-Smirnov (K-S) test confirms that these new periods confirm the distinction between the rotation period distributions of stars with and without circumstellar disks, with only a 10% probability of the two populations sharing the same parent period distribution. K-S tests do suggest, however, that the updated Taurus period distribution now more closely resembles those measured in other young star-forming clusters (i.e., NGC 2264, NGC 6530, and the ONC). This improved agreement may reflect the exclusion of long rotation periods which are detected in Taurus at lower significance, and which may be beyond the limits of detectability in more distant star-forming regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of UF6 Equation of State

A common assumption in the mathematical analysis of flows of compressible fluids is to treat the fluid as a perfect gas. This is an approximation, as no real fluid obeys the perfect gas relationships over all temperature and pressure conditions. An assessment of the validity of treating the UF{sub 6} gas flow field within a gas centrifuge with perfect gas relationships has been conducted. The definition of a perfect gas is commonly stated in two parts: (1) the gas obeys the thermal equation of state, p = {rho}RT (thermally perfect), and, (2) the gas specific heats are constant (calorically perfect). Analysis indicates the thermally perfect assumption is valid for all flow conditions within the gas centrifuge, including shock fields. The low operating gas pressure is the primary factor in the suitability of the thermally perfect equation of state for gas centrifuge computations. UF{sub 6} is not calorically perfect, as the specific heats vary as a function of temperature. This effect is insignificant within the bulk of the centrifuge gas field, as gas temperatures vary over a narrow range. The exception is in the vicinity of shock fields, where temperature, pressure, and density gradients are large, and the variation of specific heats with temperature should be included in the technically detailed analyses. Results from a normal shock analysis incorporating variable specific heats is included herein, presented in the conventional form of shock parameters as a function of inlet Mach Number. The error introduced by assuming constant specific heats is small for a nominal UF{sub 6} shock field, such that calorically perfect shock relationships can be used for scaling and initial analyses. The more rigorous imperfect gas analysis should be used for detailed analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fractal correlation properties of R-R interval dynamics and mortality in patients with depressed left ventricular function after an acute myocardial infarction

BACKGROUND: Preliminary data suggest that the analysis of R-R interval variability by fractal analysis methods may provide clinically useful information on patients with heart failure. The purpose of this study was to compare the prognostic power of new fractal and traditional measures of R-R interval variability as predictors of death after acute myocardial infarction. METHODS AND RESULTS: Time and frequency domain heart rate (HR) variability measures, along with short- and long-term correlation (fractal) properties of R-R intervals (exponents alpha(1) and alpha(2)) and power-law scaling of the power spectra (exponent beta), were assessed from 24-hour Holter recordings in 446 survivors of acute myocardial infarction with a depressed left ventricular function (ejection fraction </=35%). During a mean+/-SD follow-up period of 685+/-360 days, 114 patients died (25.6%), with 75 deaths classified as arrhythmic (17.0%) and 28 as nonarrhythmic (6.3%) cardiac deaths. Several traditional and fractal measures of R-R interval variability were significant univariate predictors of all-cause mortality. Reduced short-term scaling exponent alpha(1) was the most powerful R-R interval variability measure as a predictor of all-cause mortality (alpha(1) <0.75, relative risk 3.0, 95% confidence interval 2.5 to 4.2, P<0.001). It remained an independent predictor of death (P<0.001) after adjustment for other postinfarction risk markers, such as age, ejection fraction, NYHA class, and medication. Reduced alpha(1) predicted both arrhythmic death (P<0.001) and nonarrhythmic cardiac death (P<0.001). CONCLUSIONS: Analysis of the fractal characteristics of short-term R-R interval dynamics yields more powerful prognostic information than the traditional measures of HR variability among patients with depressed left ventricular function after an acute myocardial infarction.

Non-NASA Center↗

The structure of the broad-line region in the Seyfert galaxy Markarian 590

We have undertaken a nine-month study of continuum and emission-line variability in the Seyfert galaxy Mrk 590 in order to determine the structure of the broad-line region. The H-beta variations are found to lag behind those of the optical continuum by about 19 days. We apply a maximum entropy method to solve for the transfer function which relates the line and continuum variability. This analysis suggests that there is a deficit of emission-line response due to gas along the line of sight to the continuum source, as in the case of NGC 5548, although these data do not allow us to reject with confidence models with significant line-of-sight response. We also show that the H-beta line variability is apparently confined to the core of the emission line, as suggested previously by Ferland, Korista, and Peterson (1990).

Peterson, Bradley M.↗

Evaluation of Converter Performance Considering Static and Dynamic Device Part-to-Part Variability

This paper presents a methodology to incorporate and analyze the impact of semiconductor device part-to-part variation on power converter performance. By integrating extensive static and dynamic device characterization data with an automated compact model generation process that reflects manufacturing variability, device models with inherent variability features are utilized in converter simulations for a comprehensive assessment of performance impacts. The traditional converter performance evaluation process typically yields fixed efficiency values, often dismissing the inherent part-to-part variability caused by the manufacturing process of semiconductor devices. To address this limitation, a large population of devices was characterized to capture variations in static parameters-such as transfer, output, and capacitance characteristics-as well as dynamic behaviors, including switching losses. This data-driven approach enables the development of individual compact models, which were then integrated into converter simulations to evaluate efficiency ranges rather than single point estimated values. The converter simulation results show that part-to-part component variation can lead to significant efficiency deviations, exceeding several percentage points in high-power conversion applications. By offering a more accurate representation of converter behavior under real-world manufacturing conditions, this methodology enables designers to anticipate performance variability, improving the robustness of power converter designs.

device characterization↗

A system for automatic evaluation of simulation software

Within the field of computer software, simulation and verification are complementary processes. Simulation methods can be used to verify software by performing variable range analysis. More general verification procedures, such as those described in this paper, can be implicitly, viewed as attempts at modeling the end-product software. From software requirement methodology, each component of the verification system has some element of simulation to it. Conversely, general verification procedures can be used to analyze simulation software. A dynamic analyzer is described which can be used to obtain properly scaled variables for an analog simulation, which is first digitally simulated. In a similar way, it is thought that the other system components and indeed the whole system itself have the potential of being effectively used in a simulation environment.

Ryan, J. P.↗

Mid-Atlantic Offshore Wind Interconnection and Transmission (MAOWIT)

This project has carried out a detailed analysis to evaluate the pros and cons of offshore transmission, a possible method to decrease balance-of-system costs and permitting time identified in the DOE Office Wind Strategic Plan (DOE, 2011). It also addresses questions regarding the adequacy of existing transmission infrastructure and the ability of existing generating resources to provide the necessary Ancillary Services (A/S) support (spinning and contingency reserves) in the ISO territory. This project has completed the tasks identified in the proposal: 1. Evaluation of the offshore wind resource off PJM, then examination of offshore wind penetrations consistent with U.S. Department of Energy’s (DOE) targets and with their assumed resource size (DOE, 2011). 2. Comparison of piecemeal radial connections to the Independent System Operator (ISO) with connections via a high-voltage direct current (HVDC) offshore network similar to a team partner. 3. High-resolution examination of power fluctuations at each node due to wind energy variability 4. Analysis of wind power production profiles over the Eastern offshore region of the regional ISO to assess the effectiveness of long-distance, North- South transmission for leveling offshore wind energy output 5. Analysis of how the third and fourth items affect the need for ISO grid upgrades, congestion management, and demand for Ancillary Services (A/S) 6. Analysis of actual historic 36-hr and 24-hr forecasts to solve the unit commitment problem and determine the optimal mix of generators given the need to respond to both wind variability and wind forecasting uncertainties.

17 WIND ENERGY↗

Applying NIR and MIR spectroscopy for C and soil property prediction in northern cold-region ecosystems. Which approach works better?

Here, developing reliable predictions of soil attributes is necessary to understand northern cold-region climate-soil feedback. Calibration models using near-infrared (NIR) and mid-infrared (MIR) spectroscopy were developed to predict eight commonly measured soil properties for 119 soil samples representing a range of vegetation types, parent materials, and soil types spanning >23° of latitude from southeast Alaska to the Canadian high Arctic. In order to obtain a more accurate prediction, this study compared the performance of linear and non-linear calibration techniques, including lasso regression (Lasso), support vector machine (SVM), random forest (RF) and classic partial least squares (PLS) to predict different soil properties of these soils. Comparing the four models, we noticed that their performance was quite similar for MIR overall, while NIR achieved better results with a PLS model for our dataset. PLS coupled with MIR showed a better performance for soil parameters, such as total organic carbon (TOC), total nitrogen (TN), cation exchange capacity (CEC) and clay (R-squared of 0.9, 0.81, 0.80, and 0.84) when compared with NIR (R-squared of 0.85, 0.72, 0.81 and 0.68). However, using either MIR or NIR spectroscopy, PLS predictions for bulk density (BD) and sand content were not accurate. The variable importance analysis based on the PLS model successfully estimated the relative contribution of wavelengths influencing soil property predictions most. Overall, TOC, TN, CEC and clay mineral predictions are closely related to the occurrence of specific spectral bands in the MIR region. For example, wavelengths at 2978 and 1761 cm -1 for TOC and TN, as well as at 3064 cm -1 for CEC, were selected as the most influential predictor variables. We demonstrated that MIR spectroscopy is a powerful tool for more extensive monitoring in soils of the northern cold climate region; however, NIR could be utilized for rapid estimates when the highest accuracy is not essential.

54 ENVIRONMENTAL SCIENCES↗

Prediction of the space adaptation syndrome

The univariate and multivariate relationships of provocative measures used to produce motion sickness symptoms were described. Normative subjects were used to develop and cross-validate sets of linear equations that optimally predict motion sickness in parabolic flights. The possibility of reducing the number of measurements required for prediction was assessed. After describing the variables verbally and statistically for 159 subjects, a factor analysis of 27 variables was completed to improve understanding of the relationships between variables and to reduce the number of measures for prediction purposes. The results of this analysis show that none of variables are significantly related to the responses to parabolic flights. A set of variables was selected to predict responses to KC-135 flights. A series of discriminant analyses were completed. Results indicate that low, moderate, or severe susceptibility could be correctly predicted 64 percent and 53 percent of the time on original and cross-validation samples, respectively. Both the factor analysis and the discriminant analysis provided no basis for reducing the number of tests.

Reschke, M. F.↗