Search NASA⌕ Search

SEARCH · Search NASA

Results for “vertically aligned”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Post-Flight EDL Entry Guidance Performance of the 2011 Mars Science Laboratory Mission

The 2011 Mars Science Laboratory was the first successful Mars mission to attempt a guided entry which safely delivered the rover to a final position approximately 2 km from its target within a touchdown ellipse of 19.1 km x 6.9 km. The Entry Terminal Point Controller guidance algorithm is derived from the final phase Apollo Command Module guidance and, like Apollo, modulates the bank angle to control the range flown. For application to Mars landers which must make use of the tenuous Martian atmosphere, it is critical to balance the lift of the vehicle to minimize the range error while still ensuring a safe deploy altitude. An overview of the process to generate optimized guidance settings is presented, discussing improvements made over the last nine years. Key dispersions driving deploy ellipse and altitude performance are identified. Performance sensitivities including attitude initialization error and the velocity of transition from range control to heading alignment are presented. Just prior to the entry and landing of MSL in August 2012, the EDL team examined minute tuning of the reference trajectory for the selected landing site, analyzed whether adjustment of bank reversal deadbands were necessary, the heading alignment velocity trigger was in union with other parameters to balance the EDL risks, and the vertical L/D command limits. This paper details a preliminary postflight assessment of the telemetry and trajectory reconstruction that is being performed, and updates the information presented in the former paper Entry Guidance for the 2011 Mars Science Laboratory Mission (AIAA Atmospheric Flight Mechanics Conference; 8-11 Aug. 2011; Portland, OR; United States)

Mendeck, Gavin F.↗

Alignment apparatus using a laser having a gravitationally sensitive cavity reflector

A description is given of a device for determining a true gravitational vertical. The apparatus is composed of a vertically disposed laser with a gravitationally sensitive lower regeneration reflector. The reflector enables an output beam to be developed only when the optical axis of the laser is disposed normal to the gravitationally sensitive reflective surface. In an alternative embodiment, the devices is combined with a servo system to provide a gravitationally stabilized horizontal platform.

Billman, K. W.↗

Multiple Satellite Observations of High-Latitude Ionospheric Outflows

We will present reported observations of up- and down-flows of topside ionospheric thermal plasmas from multiple near-simultaneous tracks through the high-latitude topside ionosphere. From several Southern polar passes, it has been possible to construct plots of field-aligned flows of O+ observed by the Thermal Ion Dynamics Experiment(TIDE) on the POLAR spacecraft near 5000 km altitude together with vertical ion flow observations from one or more DMSP spacecraft near 800 km altitude. We will also involve simulations from our Dynamic Fluid-Kinetic(DyFK) modeling of polar plasma transport and display resulting altitude profiles of ion parallel velocities and densities, and overlay those profiles with the "conjunction" measurements by DMSP(800 km) and POLAR(approx. 5000 km altitude). We also will present simultaneous observations of POLAR auroral UVI images with field-aligned flows.

Horwitz, J.↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Long-range Doppler lidar measurements of wind turbine wakes and their interaction with turbulent atmospheric boundary-layer flow at Perdigao 2017

As part of the Perdigão 2017 campaign, vertical RHI (range-height indicator) scans with long-range pulsed Doppler wind lidars were performed aligned with the main wind direction and a wind turbine (WT) located on a mountain ridge. The measurements are used to not only retrieve flow velocities, but also their variance and - by using the turbulent broadening of the Doppler spectrum - also turbulent kinetic energy (TKE) dissipation rate. The study shows that turbulence in the WT wake is dependent on the turbulence of the inflow, but also on atmospheric stability. In stable atmospheric conditions, wakes could be analyzed up to five rotor diameters downstream (D) and showed the maximum turbulence in the wake at 2-3 D, whereas in unstable conditions, the maximum was found at 2 D and the wake could not be detected further than 3 D. A clear dependency of wake turbulence enhancement on inflow turbulence intensity is found, which levels out to no further enhancement at turbulence intensities of 30%.

17 WIND ENERGY↗

An Experimental Investigation of Flow Conditions in the Vicinity of an NACA D(sub S)-type Cowling

Data are presented of the flow conditions in the vicinity of an NACA D sub S -type cowling. Tests were made of a 1/2 scale-nacelle model at inlet-velocity ratios ranging from 0.23 to 1.02 and angles of attack from 6 deg to 10 deg. The velocity and direction of flow in the vertical plane of symmetry of the cowling were determined from orifices and tufts installed on a board aligned with the flow. Diagrams showing velocity ratio contours and lines of constant flow angles are given.

FLAPPED↗

Binocular Coordination of the Human Vestibulo-Ocular Reflex during Off-axis Pitch Rotation

Head movements in the sagittal pitch plane typically involve off-axis rotation requiring both vertical and horizontal vergence ocular reflexes to compensate for angular and translational motion relative to visual targets of interest. The purpose of this study was to compare passive pitch VOR responses during rotation about an Earth-vertical axis (canal only cues) with off-axis rotation (canal and otolith cues). Methods. Eleven human subjects were oscillated sinusoidally at 0.13, 0.3 and 0.56 Hz while lying left-side down with the interaural axis either aligned with the axis of rotation or offset by 50 cm. In a second set of measurements, twelve subjects were also tested during sinusoidally varying centrifugation over the same frequency range. The modulation of vertical and horizontal vergence ocular responses was measured with a binocular videography system. Results. Off-axis pitch rotation enhanced the vertical VOR at lower frequencies and enhanced the vergence VOR at higher frequencies. During sinusoidally varying centrifugation, the opposite trend was observed for vergence, with both vertical and vergence vestibulo-ocular reflexes being suppressed at the highest frequency. Discussion. These differential effects of off-axis rotation over the 0.13 to 0.56 Hz range are consistent with the hypothesis that otolith-ocular reflexes are segregated in part on the basis of stimulus frequency. At the lower frequencies, tilt otolith-ocular responses compensate for declining canal input. At higher frequencies, translational otolith-ocular reflexes compensate for declining visual contributions to the kinematic demands required for fixating near targets.

Wood, S. J.↗

Machine Learning Enabled Position Detection for 6.78 MHz UAV Wireless Power Transfer System

This paper presents a novel supervised machine learning (SML) approach for accurate position detection of the receiver coil in wireless power transfer (WPT) systems using only secondary-side electrical measurements, with applications in autonomous unmanned aerial vehicle (UAV) charging. The proposed method trains a supervised learning model to map measured secondary-side voltage and current features to the receiver’s spatial position with high precision. This enables an autonomous UAV to determine its location relative to the primary coil center, the optimal position for maximizing wireless charging efficiency. The sensing method is fully integrated into a standard WPT system, utilizing the same primary and secondary coils for both power transfer and position detection, thereby eliminating additional sensing hardware. The use of a 6.78 MHz operating frequency enhances positional sensitivity, as high-frequency near-field electromagnetic fields respond strongly to small spatial variations. Experimental validation is performed on a 30 W scaled prototype featuring a 210 mm × 140 mm primary coil, a 50 mm × 80 mm receiver coil, and a 15 mm air gap. Results demonstrate reliable position estimation and a strong correlation between predicted position and optimal coil alignment. This integrated framework unifying position detection and wireless charging offers a promising foundation for future autonomous electric vertical takeoff and landing (eVTOL) systems, enabling compact, hardware-efficient, and high-accuracy charging solutions.

Colak, Kerim [New York University]↗

Viper Science Operations: Lunar Dynamic Science Table and ‘Tracker’ Tool.

Introduction: The NASA VIPER lunar rover mission [1] presents a unique operational paradigm within the history of robotic spaceflight. The proximity of the Moon to the Earth and the terrain elements (surface characteristics, light/shadow dynamics, communication links) of the Lunar South Polar landing site create unprecedented operational conditions between these two planetary bodies. Apollo era lunar science and exploration included humans in situ to operate instruments and assimilate observational inputs in real-time. Previous lunar orbital missions have worked to operational timescales, e.g., decisional timelines and communication exchanges, that were weeks in duration. Mars rover missions have worked to operational timescales, e.g., decisional timelines and communication exchanges between Mars and Earth, that were hours, days, and weeks in length. In the case of the VIPER mission, our operational decisioning for rover driving and instrument commanding will be compressed to minute-scale timeframes. These operational conditions will directly impact the workflow and speed with which the VIPER Science Team (VST) will be required to synthesize and analyze data and produce timely science-driven decisions throughout surface mission operations [2]. The VST in the VIPER Mission Science Center (MSC) and the Mission Operations Center (MOC) shall provide mission-enhancing scientific input to guide traverse planning and drill site confirmation/selection throughout surface operations. Further, the VST input will be of vital importance to the mission’s ability to maximize science return and to meet broader NASA objectives for future lunar ISRU and exploration activities. Specifically, the VST in the MSC and MOC will provide science-driven, consensus-based, timely input and decision-making to enhance mission operations and align mission science return with broader Agency goals. They will enable the characterization of the distribution (lateral and vertical extent, concentration, variability), form (chemical/physical state of these reservoirs of lunar water and key isotopes), and context (e.g., accessibility/overburden, environment, soil mechanics, trafficability, and temperatures) of lunar polar volatiles and water content for the VIPER mission. Additionally, the MSC will be selecting or reconfirming the location and path towards and from the third drill site (Drill Site Charlie) within each Science Station [6]. To enable scientific decision-making within the operational paradigm of the VIPER lunar rover mission requires detailed articulation of the VST’s scientific objectives and goals, and the operationalization of these objectives and goals through their association with specific data products, tasks, and decisional procedures. Further, defining and tracking scientific success metrics throughout surface operations will enable the VST to have a quantified understanding of the mission’s evolving ability to accomplish the stated scientific objectives and goals both during and after the mission. This abstract provides an overview of the methods and development activities towards defining, operationalizing, and tracking scientific objectives and goals throughout VIPER surface operations. Specifically, we focus on the VIPER Lunar Dynamic Science Table (LDST) and the VIPER “Tracker” tool.

Darlene Sze Shien Lim↗

Floating device aligns blind connections

Panel-mounted connectors overcome the misalignment of blind connectors in electronic rack mounted equipment. The connector is free to move in the vertical direction by the action of a parallelogram mount. This freedom of motion maintains the guide pin hole centerline parallel to the guide pin centerline at all times.

Resel, J. E.↗

Optimizing Vertical Crystallization for Efficient Perovskite Solar Cells by Buried Composite Layers

Planar-heterojunction perovskite solar cells (PSCs) have experienced rapid evolution in recent years because of the low-temperature processing, suitable alignment, and high mobility of the tin oxide buried contact layer. However, improper SnO 2 surface states and poor crystallinity of the top perovskite films are still the main obstacles for the planar PSCs in which performance always lags behind their mesoporous counterparts. Herein, a new buried contact is reported by introducing graphitic carbon nitride (g-C 3 N 4 ) into the commonly used SnO 2 which performs outstanding transmittance, conductivity, and surface states for a high-quality electron-transporting layer. Moreover, the vertical composition and crystallinity of the top perovskite film are manipulated by rich amino groups on the edge of the g-C 3 N 4 nanosheets which induce the prenucleation of the lead-rich species at the buried interface. Benefiting from the high-quality buried contacts and the optimized perovskite layers, the resultant PSCs achieve a champion efficiency of 21.5% with all photovoltaic parameters enhanced in comparison with their control counterparts (<20%).

planar-heterojunction perovskite solar cells↗

Alternative solenoid compensation scheme for the FCC-ee interaction region

We present the optics design of the solenoid compensation scheme at the FCC-ee. The 2T solenoids from the experiments induce coupling on the beams, generating an increase on vertical emittance. This compensation scheme minimizes emittance growth, with a final value of approximately 5% of the nominal. A screening solenoid is placed around the Final Focus Quadrupoles to protect them from the experiment’s field. A skew quadrupole component is added to the Final Doublet, aligning the magnet axis to the rotated reference frame of the beam. Two anti-solenoids placed approximately ±20 m from the IP are used to cancel the field integral. The vertical orbit generated by the horizontal crossing angle in the detector field is compensated by vertical correctors placed right after the beam pipe separation and next to the final focus quadrupoles. We describe the IR optics in this scheme, including the detector solenoid and the magnetic elements used for compensation.

43 PARTICLE ACCELERATORS↗

How wind speed shear and directional veer affect the power production of a megawatt-scale operational wind turbine

Most megawatt-scale wind turbines align themselves into the wind as defined by the wind speed at or near the center of the rotor (hub height). However, both wind speed and wind direction can change with height across the area swept by the turbine blades. A turbine aligned to hub-height winds might experience suboptimal or superoptimal power production, depending on the changes in the vertical profile of wind, also known as shear. Using observed winds and power production over 6 months at a site in the high plains of North America, we quantify the sensitivity of a wind turbine's power production to wind speed shear and directional veer as well as atmospheric stability. We measure shear using metrics such as α (the log-law wind shear exponent), β bulk (a measure of bulk rotor-disk-layer veer), β total (a measure of total rotor-disk-layer veer), and rotor-equivalent wind speed (REWS; a measure of actual momentum encountered by the turbine by accounting for shear). We also consider the REWS with the inclusion of directional veer, REWS θ , although statistically significant differences in power production do not occur between REWS and REWS θ at our site. When REWS differs from the hub-height wind speed (as measured by either the lidar or a transfer function-corrected nacelle anemometer), the turbine power generation also differs from the mean power curve in a statistically significant way. This change in power can be more than 70 kW or up to 5 % of the rated power for a single 1.5 MW utility-scale turbine. Over a theoretical 100-turbine wind farm, these changes could lead to instantaneous power prediction gains or losses equivalent to the addition or loss of multiple utility-scale turbines. At this site, REWS is the most useful metric for segregating the turbine's power curve into high and low cases of power production when compared to the other shear or stability metrics. Therefore, REWS enables improved forecasts of power production.

17 WIND ENERGY↗

Description and preliminary studies of a computer drawn instrument landing approach display

A computer drawn instrument landing approach display, which shows a box located on the desired path, aligned with the path, and moving along the path at a selected distance ahead of the aircraft, was examined. Vertical and lateral displacements from the desired path and aircraft altitude information are used as inputs to the computer. A preliminary simulation study with pilot subjects has shown that the pilots find the display very easy to use, and they achieved better performance scores with the box display than with a cross pointer instrument landing display.

Adams, J. J.↗

Horn Location Sensors for LBNF

The Horn Location Sensor (HLS) system—named for the magnetic focusing horns it monitors, along with other critical beamline elements – is a high-precision alignment system developed for the Long-Baseline Neutrino Facility (LBNF) to support the Deep Underground Neutrino Experiment (DUNE). With minimal maintenance, the HLS can operate reliably in environments with high radiation, and it ensures that key components such as the protective baffle, focusing horns, and beam position monitors are aligned correctly – each essential for maintaining one of the world’s most intense muon-neutrino beams. A high-precision hydrostatic level sensor, a linear variable differential transformer, and INVAR rods are all used in the system to monitor vertical motion and tilt with sub-millimeter accuracy. A novel Sweep Tracker interferometer enhances calibration fidelity by correcting for non-linearities in laser wavelength and scan rate in real time. A critical part of DUNE’s precision alignment and flux prediction requirements, the HLS system initially supports beam power of up to 1.2 MW and can be upgraded to 2.4 MW.

Frequency scanning interferometry↗

Straight Ahead in Microgravity

INTRODUCTION The subjective straight-ahead direction is a very basic perceptual reference for spatial orientation and locomotion. The perceived straight-ahead along the horizontal and vertical meridian is largely determined by both otolith and somatosensory inputs which are altered in microgravity. The Straight Ahead in Microgravity (SAM) experiment will be conducted on the International Space Station (ISS) to examine how this spatial processing changes as a function of spaceflight. METHODS Data will be collected before the flight, at one-month intervals during long-duration stay (180 days) on board ISS, and after return to Earth. Control studies will also be performed during parabolic flights. Three different protocols will be used in each test session: (1) Fixation: The subject will be asked to look at actual targets (normal vision) and then to imagine these same targets (occluded vision) in the straight-ahead direction. Targets will be located at near distance (arm s length, ~0.5m), medium distance (~1 m), and far distance (beyond 2 m). This task will be successively performed with subject s body aligned with the spacecraft interior, and with subject s body tilted forward and backward by an operator. (2) Saccades: The subject will be asked to make horizontal and vertical saccades, first relative to the spacecraft interior reference system, and then relative to the subject s head reference system. This task will be successively performed with subject s body aligned with the spacecraft interior, and with subject s body tilted in roll or in pitch by an operator. (3) Linear Vestibulo-Ocular Reflex (VOR): The subject will be asked to stare at actual visual targets (normal vision) at various distances (near, medium, far) in the straight-ahead direction. Vision will then be occluded, and the subject will be asked to continue staring at the same imagined targets while he/she is passively translated forward-backward, up-down, or side-to-side. The subject's body motion will be performed by the restrained operator while the subject is free-floating. EXPECTED RESULTS The coupling of downward gaze with vergence eye movements observed on Earth is expected to increase in microgravity. Saccadic eye movements made in darkness along perceived axes are expected to be more closely aligned with the body s longitudinal axis in 0g compared to 1g, as the reference system for spatial orientation moves from an allocentric (gravitational) to an egocentric (idiotropic) vector. Changes in the linear VOR will reflect adaptive changes in otolith-ocular reflex contributions to the perceived straight-ahead. DISCUSSION A change in an individual's egocentric reference might have negative consequences on evaluating the direction of an approaching object or on the accuracy of reaching movements or locomotion. Consequently, investigating how microgravity affects the egocenter is important for understanding the problems associated with long-term effects of microgravity on astronauts' and how they re-adapt to the return of gravitational forces on Earth or other planetary surfaces. This project therefore has theoretical, practical and even clinical implications for the sensorimotor research gap "What are the changes in sensorimotor function over the course of a mission?"

Clement, G.↗

Response of pontomedullary reticulospinal neurons to vestibular stimuli in vertical planes. Role in vertical vestibulospinal reflexes of the decerebrate cat

1. To investigate the neural substrate of vestibulospinal reflexes in decerebrate cats, we studied the responses of pontomedullary reticulospinal neurons to natural stimulation of the labyrinth in vertical planes. Our principal aim was to determine whether reticulospinal neurons that terminate in, or are likely to give off collaterals to, the upper cervical segments had properties similar to those of the vestibulocollic reflex (VCR). 2. Antidromic stimulation was used to determine whether the neurons projected to the neck, lower cervical, thoracic, or lumbar levels. Dynamics of the responses of spontaneously firing neurons were studied with sinusoidal stimuli delivered at 0.05-1 Hz and aligned to the plane of body rotation, that produced maximal modulation of the neuron (response vector orientation). Each neuron was assigned a vestibular input classification of otolith, vertical canal, otolith + canal, or spatial-temporal convergence (STC). 3. We found, in agreement with previous studies, that the largest fraction of pontomedullary reticulospinal neurons projected to the lumbar cord, and that only a small number ended in the neck segments. Neurons projecting to all levels of the spinal cord had similar responses to labyrinth stimulation. 4. Reticulospinal neurons that received only vertical canal inputs were rare (1 of 67 units). Most reticulospinal neurons (48%) received predominant otolith inputs, 18% received otolith + canal input, and only 9% had STC behavior. These data are in sharp contrast to the results of our previous studies of vestibulospinal neurons. A considerable portion of vestibulospinal neurons receives vertical canal input (38%), fewer receive predominantly otolith input (22%), whereas the proportion that have otolith + canal input or STC behavior is similar to our present reticulospinal data. 5. The response vector orientations of our reticulospinal neurons, particularly those with canal inputs (canal, otolith + canal, STC) were predominantly in the roll quadrants. There was no evidence of convergence of inputs from like canals across the midline (e.g., right anterior + left anterior). 6. Two characteristics of the VCR, STC behavior and bilateral input from symmetric vertical canals (in some muscles), cannot be accounted for by the reticulospinal neurons that we studied. Because these characteristics are also not seen in vestibulocollic neurons, they are likely to be the result of the appropriate convergence of vestibular signals in the spinal cord. 7. Pontomedullary reticulospinal neurons seem particularly well suited to play a role in gravity-dependent postural reflexes of neck and limbs.

NASA Discipline Neuroscience↗

In Situ Imaging Reveals Efficient Charge Separation in Monolayer MoS 2 –WS 2 Type-II Heterojunctions

Covalently bonded in-plane two-dimensional (2D) transition metal dichalcogenide (TMD) heterojunctions with atomically sharp interfaces hold great promise for photocatalytic applications in solar energy conversion and environmental remediation; however, their spatially resolved charge distribution and transport, particularly under operando conditions, remain poorly understood. Here, we employ photoscanning electrochemical microscopy (photo-SECM) to directly visualize photoinduced charge separation in monolayer MoS 2 –WS 2 in-plane heterojunctions. Spatial separation of photogenerated carriers is observed, with electrons accumulating in MoS 2 and holes in WS 2 , leading to strongly asymmetric interfacial kinetics: Fc + reduction proceeds rapidly on MoS 2 (0.6 cm s –1 ), whereas Fc oxidation on WS 2 is significantly slower (0.008 cm s –1 ). High-resolution surface photovoltage microscopy (SPVM) enables a quantitative comparison of charge-separation capacity across architectures. The in-plane MoS 2 –WS 2 heterojunction shows the largest photovoltage contrast (−35 mV in MoS 2 , 20 mV in WS 2 ), exceeding the vertical heterojunction (−18 mV in MoS 2 , 11 mV in WS 2 ) and the individual monolayers (−12 mV for MoS 2 , – 1 mV for WS 2 ), establishing the following trend: in-plane > vertical > monolayers. Ultraviolet photoelectron spectroscopy (UPS) indicates that this directional charge separation is driven by intrinsic type-II band alignment, while photoluminescence (PL) imaging shows that the interface acts as a recombination center that limits efficient carrier extraction. These results provide direct experimental evidence of type-II-driven charge separation in in-plane heterojunctions and offer critical insights for interface design in high-efficiency photocatalytic and optoelectronic systems.

electrical properties↗