Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage regulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Designing Hydropower Flows to Balance Energy and Environmental Needs (HydroWIRES Topic A Final Project Report)

Hydropower is expected to play a new role in the US electricity grid as more variable renewable energy sources like wind and solar come online. Wind and solar generation increase fluctuations in electrical supply increasing the value of flexible generation sources that can quickly ramp generation up and down. The flexible generation hydropower can provide as well as the ancillary services (e.g., frequency and voltage regulation and reserves, black start capability) it provides for balancing and stabilizing the power grid are predicted to be of increased value in these future grid scenarios. Yet, the flexibility of hydropower may come with environmental costs due to up- and down-ramping of hydropower plants (i.e., quickly increasing or decreasing generation flows, respectively) which may strand fish, dewater or scour fish nests, alter habitat, or create unsafe recreational conditions that may be unacceptable to participants in the hydropower regulatory process. These types of environmental impacts are often mitigated through environmental flow requirements that specify minimum or maximum flow releases, or ramp-rates changes allowed at a hydropower facility. While it is not currently known to what degree electrical grid reliability could be affected by environmental flow requirements, gaining a better understanding of these interactions before the grid becomes more deeply decarbonized can help define what policy, regulation, or infrastructure may be needed to support the clean energy transition. As the future grid will rely on hydropower to provide both flexibility and robust environmental protections, the analyses and tools described in this report are centered on making mechanistic linkages between energy and the environment in hydropower systems. This understanding of energy-environment linkages can provide the foundational understanding needed to quantitatively assess the trade-offs between the increased generation flexibility that hydropower will be expected to provide and the environmental impacts of this flexibility. This report seeks to provide an objective foundation for building future science and tools that can be used by a broad spectrum of the hydropower community that is involved in licensing or environmental regulatory proceedings tasked with balancing energy and environmental objectives through flow management.

13 HYDRO ENERGY↗

Distribution Grid Impacts of Community Solar [Slides]

Community solar (CS) projects often face uncertain interconnection costs and fees associated with distribution grid infrastructure upgrades required to connect the project. These costs can determine the economic viability of a CS project, but they are difficult to assess. Cost uncertainty can discourage new projects and prevent communities from accessing the benefits of community solar projects. At the same time, CS deployment strategies hold potential to defer or avoid some distribution costs due to new loads. To mitigate CS interconnection costs, it is important to find least-cost combinations of distribution system infrastructure solutions (transformer upgrades, reconductoring, voltage regulators, storage), and to understand how location of CS projects within a feeder impact distribution grid upgrade costs. This study aims to quantify CS impacts on the distribution grid and provide policy and regulatory insights and CS deployment strategies to address them. It is the first analysis that has systematically studied the technical impacts of community solar projects on a wide range of distribution feeders using state-of-the-art optimization and power flow tools. The analysis employs Berkeley Lab’s novel Least-cost Optimal Distribution Grid Expansion (LODGE) model, a deterministic version of the REPAIR model, that optimally upgrades hundreds or even thousands of distribution circuits or feeders. This is the first application of the LODGE model. LODGE finds the least-cost portfolio of traditional distribution system upgrades to integrate CS in combination with alternative solutions, such as utility-owned storage and downsizing CS capacity. Working with a set of least-cost solutions per feeder allows us to benchmark, compare and find techno-economic trends in CS interconnection.

14 SOLAR ENERGY↗

Communication-Constrained Robust Control and Learning of Grid-Connected

The electric grid of things (EGoT) promises great potential for innovative grid services by tapping into vast load flexibility. However, the unique characteristics of EGoT, being a part of the cyber-physical electric power system, present both opportunities and challenges, especially concerning supply-demand balancing, stability, and communication constraints. Traditionally, centralized control was employed to ensure balance and stability in power systems. However, with the massive influx of EGoT devices, new strategies are needed to efficiently coordinate and control these distributed devices for optimal grid operations. While some studies have explored efficiency and economic models, there remains a gap in ensuring reliability under everyday operations and resilience during extreme conditions. Addressing this gap, this project develops the technology for an Energy Service Interface (ESI) that includes novel pricing, control, learning, and distributed optimization algorithms, which will enable utilities to recruit EGoT assets for crucial grid services such as load flexibility, voltage regulation, and situation-awareness. The key novelty of the proposed technology is the careful distribution of learning and control functions across utility and EGoT asset owners such that provably efficient and resilient grid operations are attained while respecting communication and information-exchange constraints. Specifically, the project team develops machine-learning enhanced load modeling methods to allow EGoT asset owners to learn their load capability and flexibility, and develops pricing-based and decentralized learning-based control so that asset owners can coordinate to meet system-wide demand-supply balance and reliability goals. For extreme situations involving high-impact, low-probability catastrophic events (termed the “black-sky” events), the team also develops (1) a “Feeder-Operating Center-on-a-Laptop” (FOCAL) software that can assist utility personnel in leveraging EGoT assets to accelerate the service recovery of damaged feeders, and (2) distributed optimization algorithms that can coordinate the operation points of EGoT devices under severe communication constraints. The proposed technology has been extensively tested and evaluated through simulations and on a testbed. In summary, as we transition into a more interconnected and digital power grid era, our project’s findings and developments offer a pivotal step toward guaranteeing both efficiency and resilience in the face of both everyday operations and rare “black-sky” events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Optimal Operation and Impact Assessment of Distributed Wind for Improving Efficiency and Resilience of Rural Electricity Systems

This project aims to empower rural utilities by developing advanced optimization models and algorithms for effectively integrating distributed wind energy alongside battery storage and other distributed energy resources (DERs). The primary objectives are to reduce peak demand, ensure reliable emergency power supply, and regulate voltage and frequency. To address operational challenges, the project introduces innovative mitigation strategies and ultrafast assessment frameworks to evaluate the impacts of distributed wind and DERs on rural grids, offering actionable solutions to potential issues. Economic viability is assessed through cost-benefit analysis using real rural utility data, ensuring the practical application of the project outcomes.

17 WIND ENERGY↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Supercapacitor-Based Power Resilience Solutions for Modern Grids, Microgrids, and Facilities

This report summarizes the tests and results of a supercapacitor based energy storage system demonstration project performed in collaboration with Capacitech Energy, Orlando Utilities Commission and Sandia National Labs. This project evaluated a 3.6 farad (F), 720 V rated supercapacitor system in a microgrid environment to study three primary use cases: black start, voltage regulation, and load leveling, and successfully demonstrated the performance for the use cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Least-cost Optimal Distribution Grid Expansion (LODGE): Utility Pilots

The Least-cost Optimal Distribution Grid Expansion (LODGE) model provides the optimal portfolio of distribution system upgrades—e.g., voltage regulators, feeder reconductoring, transformer upgrades and non-wires alternatives (NWA), such as strategic siting of storage and distributed generation—to interconnect distributed energy resources (DERs) and enable load growth. It can be used to assess grid infrastructure costs and explore policy and regulatory solutions for distribution planning and DER valuation.In 2025, Berkeley Lab conducted three pilot analyses to validate LODGE results with empirical utility data before the model’s first release in 2026. The pilots, done with utilities in Washington, Colorado, and New Mexico, provide examples that illustrate how the model works, what it can do, and the value of the analysis.

Heleno, Miguel↗

Model-Free Primal-Dual Methods for Network Optimization with Application to Real-Time Optimal Power Flow

This paper examines the problem of real-time optimization of networked systems and develops online algorithms that steer the system towards the optimal trajectory without explicit knowledge of the system model. The problem is modeled as a dynamic optimization problem with time-varying performance objectives and engineering constraints. The design of the algorithms leverages the online zero-order primal-dual projected-gradient method. In particular, the primal step that involves the gradient of the objective function (and hence requires a networked systems model) is replaced by its zero-order approximation with two function evaluations using a deterministic perturbation signal. The evaluations are performed using the measurements of the system output, hence giving rise to a feedback interconnection, with the optimization algorithm serving as a feedback controller. The paper provides some insights on the stability and tracking properties of this interconnection. Finally, the paper applies this methodology to a real-time optimal power flow problem in power systems, and shows its efficacy on the IEEE 37-node distribution test feeder for reference power tracking and voltage regulation.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Generic Primary-Control Model for Grid-Forming Inverters: Towards Interoperable Operation & Control

This paper outlines an architectural vision centered around the notion of interoperability to integrate grid-forming inverter-based resources in large-scale grids. With the underlying principle of interoperability guiding developments, we focus on modeling the characteristics of droop, virtual synchronous machine, and virtual oscillator controls. Emphasis is placed on these three controllers since they are leading grid-forming control candidates and are likely to be commonplace as primary-control schemes in future systems. We show that these controllers can each be considered as instantiations of a more generic model and that all these controllers exhibit similar droop-like relations between pertinent terminal variables in steady state. This commonality between controllers gives interoperability among them such that automatic synchronization, power sharing, and voltage regulation can be achieved. Simulation results validate the models and demonstrate how the steady-state droop characteristics of these control methods can be aligned with the aid of the developed modeling paradigm.

control↗

Estimating and Calibrating DER Model Parameters Using Levenberg–Marquardt Algorithm in Renewable Rich Power Grid

The proliferation of inverter-based distributed energy resources (IBDERs) has increased the number of control variables and dynamic interactions, leading to new grid control challenges. For stability analysis and designing appropriate protection controls, it is important that IBDER models are accurate. This paper focuses on the accurate estimation and parameter calibration of DER_A, a recently proposed aggregated IBDER model. In particular, we focus on the parameters of the reactive power–voltage regulation module. We formulate the problem of parameter tuning as a non-linear least square minimization problem and solve it using the Levenberg–Marquardt (LM) method. The LM method is primarily chosen due to its flexibility in adaptively selecting between the steepest descent and Gauss–Newton methods through a damping parameter. The LM approach is used to minimize the error between the actual measurements and the estimated response of the model. Further, the computational challenges posed by the numerical calculation of the Jacobian are tackled using a quasi-Newton root-finding approach. The proposed method is validated on a real feeder model in the northeastern part of the United States. The feeder is modeled in OpenDSS and the measurements thus obtained are fed to the DER_A model for calibration. The simulation results indicate that our approach is able to successfully calibrate the relevant model parameters quickly and with high accuracy, with a total sum of square error of 3.57 × 10 –7 .

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Dual-voltage power supply has increased efficiency

Simple circuit provides two different dc output voltages from an ac source. It employs a full-wave rectifier connected to two passive branches from which the separate dc voltages are taken. The outputs have low ripple and good voltage regulation.

Sturman, J. C.↗

Constant-frequency, variable-duty-cycle multivibrator

Circuit provides a pulse source of constant frequency with a duty cycle that is adjustable by an external input signal. It could serve as a switching mode voltage regulator or as a switching source for control systems.

Johnson, J. E.↗