Search NASA⌕ Search

SEARCH · Search NASA

Results for “water availability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Coastal groundwater salinization impairs tree carbon–water balance

How coastal forest productivity varies with local nutrient availability and water supply remains a knowledge gap under climate change. In a two-decade field experiment manipulating fertilization and density in coastal pine forests, we show that a decade of growth enhancement by simulated sedimentary nutrient inputs has resulted in a striking reversal in growth and increased mortality risk as drought and sea level rise progressed. Recent groundwater salinization has further triggered a shift from nutrient to water limitation, causing severe stomatal closure and decoupling of tree carbon–water balance, which induces a negative intrinsic water use efficiency (iWUE)–growth relationship. Higher tree iWUE predicted sharper tree growth declines, and both nutrient enrichment and high stand density amplified this feedback, increasing the risk of hydraulic failure and mortality. These results suggest that a transient nutrient-stimulatory effect could drive further coastal forest degradation due to heightened belowground saltwater stress under sea-level rise.

Climate-change ecology↗

Are Atmospheric Models Too Cold in the Mountains? The State of Science and Insights from the SAIL Field Campaign

Mountains play an outsized role in water resource availability, and the amount and timing of water they provide depend strongly on temperature. To that end, we ask the question: How well are atmospheric models capturing mountain temperatures? We synthesize results showing that high-resolution, regionally relevant climate models produce 2-m air temperature (T2m) measurements colder than what is observed (a “cold bias”), particularly in snow-covered midlatitude mountain ranges during winter. We find common cold biases in 44 studies across global mountain ranges, including single-model and multimodel ensembles. We explore the factors driving these biases and examine the physical mechanisms, data limitations, and observational uncertainties behind T2m. Our analysis suggests that the biases are genuine and not due to observation sparsity or resolution mismatches. Cold biases occur primarily on mountain peaks and ridges, whereas valleys are often warm biased. Our literature review suggests that increasing model resolution does not clearly mitigate the bias. By analyzing data from the Surface Atmosphere Integrated Field Laboratory (SAIL) field campaign in the Colorado Rocky Mountains, we test various hypotheses related to cold biases and find that local wind circulations, longwave (LW) radiation, and surface-layer parameterizations contribute to the T2m biases in this particular location. We conclude by emphasizing the value of coordinated model evaluation and development efforts in heavily instrumented mountain locations for addressing the root cause(s) of T2m biases and improving predictive understanding of mountain climates.

54 ENVIRONMENTAL SCIENCES↗

Are Atmospheric Models Too Cold in the Mountains? The State of Science and Insights from the SAIL Field Campaign

Mountains play an outsized role in water resource availability, and the amount and timing of water they provide depend strongly on temperature. To that end, we ask the question: How well are atmospheric models capturing mountain temperatures? We synthesize results showing that high-resolution, regionally relevant climate models produce 2-m air temperature (T2m) measurements colder than what is observed (a “cold bias”), particularly in snow-covered midlatitude mountain ranges during winter. We find common cold biases in 44 studies across global mountain ranges, including single-model and multimodel ensembles. We explore the factors driving these biases and examine the physical mechanisms, data limitations, and observational uncertainties behind T2m. Our analysis suggests that the biases are genuine and not due to observation sparsity or resolution mismatches. Cold biases occur primarily on mountain peaks and ridges, whereas valleys are often warm biased. Our literature review suggests that increasing model resolution does not clearly mitigate the bias. By analyzing data from the Surface Atmosphere Integrated Field Laboratory (SAIL) field campaign in the Colorado Rocky Mountains, we test various hypotheses related to cold biases and find that local wind circulations, longwave (LW) radiation, and surface-layer parameterizations contribute to the T2m biases in this particular location. We conclude by emphasizing the value of coordinated model evaluation and development efforts in heavily instrumented mountain locations for addressing the root cause(s) of T2m biases and improving predictive understanding of mountain climates.

54 ENVIRONMENTAL SCIENCES↗

A Review: Flow Electrode Capacitive Deionization for Improved Electrochemical Water Desalination

In many places of the world people have continued to suffer from major droughts and water shortages. With climate change climbing in intensity, these dry conditions will only worsen. With much of the world’s water in the ocean, both saltwater and brackish water have been identified as key water sources. Currently, there are several technologies available for water desalination and treatment such as reverse osmosis, capacitive deionization, electrodialysis, and flow electrode capacitive deionization. This paper will briefly review each of these technologies and propose a new design to improve the current flow electrode capacitive deionization architecture. The new design uses a current collector flow-electrode architecture that has the potential to achieve record thermodynamic energy efficiencies. This formulation is proprietary to Lawrence Livermore National Laboratory.

36 MATERIALS SCIENCE↗

Non-Fouling, Low Cost Electrolytic Coagulation & Disinfection for Treating Flowback and Produced Water for Reuse

Executive Summary This Final Report is composed of two major sections. The first section presents experimental results obtained in the laboratory during Budget Period 1. The second section presents results from the field test conducted during Budget Period 2. Laboratory Results This research investigated a novel electrochemical process for producing a ferric iron coagulant for use in treating flowback and produced water from hydraulic fracturing and oil production operations. The treatment system improves the effectiveness and lowers the cost of coagulation processes using Fe3+ as the coagulant. The electrolytic coagulant generation (ECG) system uses an electrochemical cell to produce acid and base from oilfield brine solutions. The acid is used to dissolve scrap iron to provide a Fe3+ coagulating agent. The base is used to neutralize the treated water. Compared to conventional electrocoagulation (EC), the main advantage of the ECG system is an order of magnitude lower cost for the source of iron. The second advantage over conventional EC is that it can deliver Fe3+ doses greater than 1 mM, since it is not limited by the amount of dissolved oxygen in the water required to oxidize ferrous to ferric iron. The capital costs for conventional EC and the ECG system are similar, but the operational costs for the ECG system are an order of magnitude lower than conventional EC. The combined costs for iron and electrical energy for treating 1 m3 of FPW with 1 mM Fe3+ is estimated to be $0.87 for conventional EC, and $0.087 for the ECG system. The estimated all-in cost for treating FPW with a 2 mM Fe3+ dose is $0.73/m3 ($0.12/bbl). Field Test Results The field test was conducted at the Paul Foster Central Tank Battery (CTB) in Lea County, New Mexico from November 10, 2022 through December 15, 2022. The feed water to the system was produced water from the Tatanka 1H formation. After approximately two weeks of testing, the initial batch of produced water had been treated and no untreated produced water was available. Thus, after this time, the feed water to the system consisted of previously treated water (i.e., recycled water). The recycled water had nearly all colloidal particles removed, and had a much lower alkalinity due to precipitation of carbonate minerals during the first pass through the system. Although the recycled water was not an ideal test solution due to its low particulate concentrations, its lower alkalinity did allow us to identify the main problem with the treatment system. The main problem with the treatment system was caused by the high alkalinity of the initial feed water (5.4 meq/L) that consumed a significant fraction of the electrochemically generated acid. This resulted in pH values exiting the iron contact tank that were too high to dissolve enough iron to effectively treat the produced water. Tests performed with recycled water with lower alkalinity did not have this issue, and dissolved iron concentrations greater than 20 mM could be achieved. One consistent observation was that effluent water from the iron contact tank was always free of particulates, even when fed with circumneutral solutions. This suggests that there is no need to dissolve high concentrations of iron if all the water to be treated is passed through the scrap iron canister. In this case, dissolved O2 and hypochlorous acid can promote sufficient iron corrosion to provide an effective coagulating agent – even in neutral pH water. This solves the problem resulting from highly alkaline produced water. Modifications to the design of the treatment system were made based on the field test results. These modifications will add minimal additional cost, and were tested in bench-scale laboratory experiments. In short-term testing, the modified treatment process was able to remove colloidal FeS particulates to levels below detection. Long-term, steady state testing will be required to determine whether the modified process is suitable for commercial treatment systems.

54 ENVIRONMENTAL SCIENCES↗