Search NASA⌕ Search

SEARCH · Search NASA

Results for “water demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Cargo Logistics Airlift Systems Study (CLASS). Volume 3: Cross impact between the 1990 market and the air physical distribution systems, book 2

Book 2 of this volume is divided into the following sections: (1) commodities and system networks; (2) future mode choice decisions and commodity air eligibility; (3) comparative cargo transportation costs - air, truck, rail and water; (4) elasticities of demand; (5) operating cost; (6) operating profit, rate making, and returns; (7) importance of rate and service on future aircraft; (8) potential market demand for new aircraft; (9) scenario of events affecting system/market growth; and (10) future study and technology requirements.

Burby, R. J.↗

Solar energy system installed at the North Georgia APDC office building

A hydronic, automatic drain-down solar heating and cooling system is described. The system provides solar heat exchange from a 2,001 square foot effective collector area and supplies 65-70 percent of the building's cooling demand, 90-95 percent of the heating demand, and domestic hot water. The acceptance test plan and results, system operation and maintenance, and predicted system performance are presented.

Source record↗

The Urban Heat Island Phenomenon: How Its Effects Can Influence Environmental Decision Making in Your Community

Reinvestment in urban centers is breathing new life into neighborhoods that have been languishing as a result of explosive suburban development over the past several decades. In cities all over the country, adaptive reuse, brownfields redevelopment, transforming urban landscapes, economies, and quality of life. However, the way in which this development occurs has the potential to exacerbate the urban heat island (UHI) phenomenon, an existing problem in many areas and one which poses a threat to the long-term sustainability and environmental quality of cities. The UHI phenomenon is rooted in the science of how the land covers respond to solar heating and can adversely effect the environment. This phenomenon is responsible for urban centers having higher air temperatures and poorer air quality than suburban areas. In addition, the UHI phenomenon causes metrological occurrences, degrades water quality, increases energy demands, poses threats to public health and contributes to global warming. While the name of the phenomenon implies that is solely an urban issue, research has shown that the effects of the UHI are becoming prevalent in suburbs, as well. The UHI phenomenon can plague regions - urban centers and their suburbs. Furthermore, heat islands have been found to exist in both city centers and suburban communities. As suburban areas increasingly develop using land covers and building materials common to urban areas, they are inheriting urban problems - such as heat islands. In this way, it may be necessary for non-urban communities to engage in heat island mitigation. The good news is that through education and planning, the effects of the UHI phenomenon can be prevented and mitigated. Heat islands are more a product of urban design rather than the density of development. Therefore, cities can continue to grow and develop without exacerbating the UHI by employing sustainable development strategies.

Estes, Maurice G., Jr.↗

Security-by-Design: Light Water Small Modular Reactor

The growing demand for nuclear power is increasing pressure to find solutions to cost prohibitive requirements of both construction and security. Offsite response has been proposed as an option to reduce costs associated with training and maintaining an onsite response force. A previous report explored this option and revealed that security could be provided at the required level, but cost savings was not a result of this methodology. An offsite response strategy required costly active and passive delay barriers to provide sufficient time for responders to muster and deploy to a site in time to interrupt a determined and well-equipped adversary. Also, contrary to the hypothesis, the number of responders required for this strategy exceeded that needed for an onsite response force, as the adversaries could avail themselves of advantageous positions within the facility to repel arriving responders. This report builds upon the previous evaluation by using the same hypothetical light water small modular reactor (LWSMR) facility model, but this time an onsite response strategy was assessed. The goal of this analysis was to show that an onsite response strategy could be implemented effectively at a cost point that removes barriers within the industry at this critical time of growth and development. The assessment of the facility design and response strategy was completed through modeling using Scribe3D© and subsequent scenario analysis over the course of a two-day tabletop exercise. Subject matter experts in nuclear security, nuclear facility design, and response strategy and tactics contributed to the effort to ensure accurate representation of hypothetical scenarios. Several adaptations were made to the layout of the LWSMR based on lessons learned during the first day of scenario analysis. The subsequent design evaluated on the second day proved to provide a robust response posture against a large and well-trained adversary force. This report details the process of the analysis and compares the cost of the final facility design with that of the LWSMR model used for evaluation of offsite response. Ultimately, the results of this effort indicate that, when implemented correctly, an onsite response strategy is the best option from a security and cost perspective.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advancing Diagnostic Model Evaluation to Better Understand Water Shortage Mechanisms in Institutionally Complex River Basins

Abstract Water resources systems models enable valuable inferences on consequential system stressors by representing both the geophysical processes determining the movement of water and the human elements distributing it to its various competing uses. This study contributes a diagnostic evaluation framework that pairs exploratory modeling with global sensitivity analysis to enhance our ability to make inferences on water scarcity vulnerabilities in institutionally complex river basins. Diagnostic evaluation of models representing institutionally complex river basins with many stakeholders poses significant challenges. First, it needs to exploit a large and diverse suite of simulations to capture important human‐natural system interactions as well as institutionally aware behavioral mechanisms. Second, it needs to have performance metrics that are consequential and draw on decision‐relevant model outputs that adequately capture the multisector concerns that emerge from diverse basin stakeholders. We demonstrate the proposed model diagnostic framework by evaluating how potential interactions between changing hydrologic conditions and human demands influence the frequencies and durations of water shortages of varying magnitudes experienced by hundreds of users in a subbasin of the Colorado River. We show that the dominant factors shaping these effects vary both across users and, for an individual user, across percentiles of shortage magnitude. These differences hold even for users sharing diversion locations, demand levels or water right seniority. Our findings underline the importance of detailed institutional representation for such basins, as institutions strongly shape how dominant factors of stakeholder vulnerabilities propagate through the complex network of users.

Hadjimichael, Antonia↗

ENERGY STAR Residential Water Heater Specification and Test Method for Connected Residential Water Heaters

Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.

connected water heater↗

Magnetic Nanoparticle Extraction of Lithium from Produced Waters - CRADA 483 (Final Report)

The demand for lithium in the energy production industry is expected to increase sharply, development of simple and cost-effective techniques for lithium production and recovery from various lithium sources is essential. In this project, core/shell magnetic nanoparticles were successfully designed to selectively extract lithium from aqueous lithium sources as an extension of Pacific Northwest National Laboratory’s magnetic nanofluid extraction technology. The core/shell magnetic nanoparticles are composed of manganese oxide-based lithium ion sieve shells, which allow selective lithium uptake from brines with multiple coexisting ions, over iron oxide cores, which can respond to external magnetic fields for effective recovery and reuse of adsorbents from a liquid. The synthesized lithium ion-sieves and core/shell magnetic nanoparticles were characterized using several techniques to reveal their crystallinity and morphology. The lithium uptake properties of the lithium ion-sieves and core/shell magnetic nanoparticles were evaluated in terms of lithium adsorption capacity, removal percentage, selectivity, and cycling performance in simulated and natural brines. Magnetic properties of the core/shell magnetic nanoparticles were tested by measuring magnetic saturation, and magnetic response of colloidal solutions containing the core/shell magnetic nanoparticles was tested with permanent magnets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparison of the Environmental Effects of Open-Loop and Closed-Loop Pumped Storage Hydropower

Pumped storage hydropower (PSH) is a type of energy storage that uses the pumping and release of water between two reservoirs at different elevations to store water and generate electricity (Figure ES-1). When demand for electricity is low, a PSH project can use low cost energy to pump water from the lower reservoir to the upper reservoir for storage. When demand for electricity is high, a PSH project can release water from the upper reservoir through a powerhouse to generate electricity. Traditionally, this meant that PSH plants generated power during the day and pumped at night, with modest diurnal or seasonal variation.

13 HYDRO ENERGY↗

Intercalated water in aqueous batteries

The unprecedentedly growing demand for energy storage devices in recent years calls for diversified chemistries with unique advantages. When it comes to safety and cost, aqueous battery systems have attracted tremendous attention. Being a universal solvent, water can solvate the cations with rather high dehydration energy due to the hydrogen bonding environment, relatively small size and high polarity. Such properties make solvent co-intercalation, which is seen in a few of the non-aqueous systems, more likely to happen in aqueous batteries. Hydrated cations show drastically different behaviors from naked cations during intercalation/de-intercalation processes and hence enable many reactions that are otherwise difficult to proceed. This review summarizes the roles of co-intercalated water in aqueous batteries from how water molecules coordinate with cations to examples of water-mediated reactions in different types of host materials.

25 ENERGY STORAGE↗

Long-term socioeconomic trends and climate variability as drivers of virtual water scarcity in China

Water scarcity can have far-reaching sectoral impacts beyond its physical location through the propagation of virtual water flows. Socioeconomic and hydroclimatic changes affect local and virtual water scarcity by altering availability and demand. Yet most studies of this phenomenon focus on volumetric footprints, and the few on water scarcity risk have not examined hydroclimatic variability beyond long-term trends. In this study, we ask how gross domestic product (GDP) and population changes, long-term meteorological trends, sea surface temperature (SST) patterns, and interannual meteorological variability affect water scarcity in China, both locally (through the local water scarcity risk index, LWSR) and remotely (through the virtual water scarcity risk index, VWSR). Counterfactual scenarios were compared in a regression-and-simulation framework, with the socioeconomic and meteorological drivers varying over 1923–2019 and the multi-regional input–output structure staying fixed at 2017. Relative to a 5 year baseline centered on 2017, GDP and population changes have induced a cumulative 17%–50% increase in LWSR and 13%–21% increase in VWSR, outweighing the effect of long-term meteorological trends. phase change in one of two examined SST patterns induce 4%–13% differences in LWSR and 1%–4% differences in VWSR. Interannual meteorological variability induces 10%–20% standard deviations in LWSR and 3%–7% in VWSR. The findings highlight the importance of using longer time series to accurately assess local and virtual water scarcity situations. Water scarcity management should prioritize socioeconomic factors when planning at century-long timescales and prioritize hydroclimatic factors at multidecadal or shorter timescales. water managers should consider interannual variabilities in LWSR and VWSR and plan for potential occurrences of extreme conditions.

climate variability↗

A Fresnel collector process heat experiment at Capitol Concrete Products

An experiment is planned, conducted and evaluated to determine the feasibility of using a Power Kinetics' Fresnel concentrator to provide process heat in an industrial environment. The plant provides process steam at 50 to 60 psig to two autoclaves for curing masonry blocks. When steam is not required, the plant preheats hot water for later use. A second system is installed at the Jet Propulsion Laboratory parabolic dish test site for hardware validation and experiment control. Experiment design allows for the extrapolation of results to varying demands for steam and hot water, and includes a consideration of some socio-technical factors such as the impact on production scheduling of diurnal variations in energy availability.

Hauger, J. S.↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

99 GENERAL AND MISCELLANEOUS↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region (CRADA Final Report)

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

15 GEOTHERMAL ENERGY↗

The Conventional Gas Diffusion Electrode May Not Be Resistant to Flooding during CO 2 /CO Reduction

The electrochemical CO 2 or CO reduction to chemicals and fuels using renewable energy is a promising way to reduce anthropogenic carbon emissions. The gas diffusion electrode (GDE) design enables low-carbon manufacturing of target products at a current density (e.g., 500 mA cm –2 ) relevant to industrial requirements. However, the long-term stability of the GDE is restricted by poor water management and flooding, resulting in a significant hydrogen evolution reaction (HER) within almost an hour. The optimization of water management in the GDE demands a thorough understanding of the role of the gas diffusion layer (GDL) and the catalyst layer (CL) distinctively. In this work, the hydrophobicity of the GDL and CL is independently adjusted to investigate their influence on gas transport efficiency and water management. The gas transport efficiency is more enhanced with the increase in hydrophobicity of the GDL than the CL. Direct visualization of water distribution by optical microscope and micro-computed tomography demonstrates that the water flow pattern transfers from the stable displacement to capillary fingering as GDL hydrophobicity increases. Unfortunately, only increasing the hydrophobicity is not sufficient to prevent flooding. A revolutionary change in the design of the GDE structure is essential to maintain the long-term stability of CO 2 /CO reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intermediate Sr 2 Co 1.5 Fe 0.5 O 6-δ Tetragonal Structure between Perovskite and Brownmillerite as a Model Catalyst with Layered Oxygen Deficiency for Enhanced Electrochemical Water Oxidation

The generation of hydrogen in an environmentally benign way is highly essential to meet future energy demands. However, in the process of splitting water electrochemically, sluggish kinetics of the oxygen evolution reaction (OER) curtails its applicability, as it drags energy input. Herein, we synthesized SrCo-Fe-O oxides to optimize their OER activity by varying the Co/Fe ratio. Among them, Sr 2 Co 1.5 Fe 0.5 O 6-δ exhibited the best OER catalytic activity in the series, with an overpotential of 318 mV at 10 mA cm -2 and Tafel slope of 44.8 mV dec -1 . High-resolution neutron powder diffraction analysis identified an intermediate structure between the perovskite and brownmillerite, with alternating layers of disorderly orientated oxygen-deficient tetrahedra and fully stoichiometric octahedra. The unique stacking of tetrahedral and octahedral units facilitates desired interactions between the electrode surface and electrolyte. Theoretical calculations revealed that increased covalency of Co 3d and O 2p in Sr 2 Co 1.5 Fe 0.5 O 6-δ oxide is another primary contributor to its augmented water oxidation ability. As a model for developing catalysts with such an intermediate structure, the synergetic effect of oxygen vacancy and hybridization between Co 3d and O 2p assured the Sr 2 Co 1.5 Fe 0.5 O 6-δ oxide as a better catalyst for its enhanced OER activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Domestic Hot Water Temperature Maintenance Technology Review

Domestic hot water temperature maintenance (HWTM) is an important topic in facility management, and there are often opportunities to optimize systems to achieve energy, water, and maintenance savings. The main purpose of an HWTM system is to provide reliable hot water temperature at all fixtures with minimal wait time. This is done by replacing the standby heat losses from hot water sitting idle in pipes during periods of low demand. Traditionally, most commercial buildings do this by having water recirculate back to the water heater to be reheated. Other currently available HWTM systems are also discussed in this resource. HWTM systems can help maintain water at appropriate temperatures, minimize heat loss, and minimize delivery times to fixtures to improve the function of a building. This webpage includes a summary of HWTM options along with important considerations regarding occupant safety and comfort, and maintenance strategies for optimal and efficient operations. Domestic hot water (DHW) generation systems are referred to but are not the focus of this resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of reclaimed potable water quality criteria

In order to minimize launch requirements necessary to meet the demands of long-term spaceflight, NASA will reuse water reclaimed from various on-board sources including urine, feces, wash water and humidity condensate. Development of reclamation systems requires the promulgation of water quality standards for potable reuse of the reclaimed water. Existing standards for domestic U.S. potable water consumption were developed, but do not consider the peculiar problems associated with the potable reuse of recycled water. An effort was made to: (1) define a protocol by which comprehensive reclaimed water potability/palatability criteria can be established and updated; and (2) continue the effort to characterize the organic content of reclaimed water in the Regenerative Life Support Evaluation.

Flory, D. A.↗

6 um Pulsed OP-GaAs OPO Laser for Unambiguous Water Ice Detection on the Moon and Other Planetary Bodies

NASA demands a laser transmitter for planetary remote sensing to detect water-ice on the Moon and other planetary bodies. Based on the measurement of the Moon Mineralogy Mapper (M3) instrument, the discovery of water ice on the Moon was acclaimed, but the measurement is disputed because OH- and/or H2O-bearing materials share the absorption line around 3 μm wavelength. Lunar Flashlight, another mission project exploring the surface of Moon which will be launched later this year, enables to map the minerals on dark area of the Moon, but could not resolve the above-mentioned ambiguity. The absorption of 6.08 μm light is uniquely associated with the bending resonance of H2O since there is no comparable vibration in confounding OH-bearing materials. 6.08 μm laser between the atmospheric windows: middle-wave infrared (3-5 μm) and long-wave infrared (8-12 μm) has not been commercially available. Our approach is a Q-switched Ho:YLF laser pumped the orientation-pattern Gallium Arsenide optical parametric oscillator (OP-GaAs OPO) for generating high-energy laser pulses at the wavelength of 6.08 μm. In the current design, a 1.94 μm Tm:fiber is used as the pump source. In the compact design, a 1.94 μm laser diode will replace the Tm:fiber laser as the pump source. We will combine this proposed mid-infrared laser with the latest HgCdTe avalanche photodiode (APD) array to design a lidar for detecting water ice on the Moon and Mars from their respective orbits, enabling novel science and in-situ resource utilization. Our instrument is an enabling technology aboard the Artemis program and others.

mid-infrared laser↗