Search NASA⌕ Search

SEARCH · Search NASA

Results for “water sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Ocean time-series near Bermuda: Hydrostation S and the US JGOFS Bermuda Atlantic time-series study

Bermuda is the site of two ocean time-series programs. At Hydrostation S, the ongoing biweekly profiles of temperature, salinity and oxygen now span 37 years. This is one of the longest open-ocean time-series data sets and provides a view of decadal scale variability in ocean processes. In 1988, the U.S. JGOFS Bermuda Atlantic Time-series Study began a wide range of measurements at a frequency of 14-18 cruises each year to understand temporal variability in ocean biogeochemistry. On each cruise, the data range from chemical analyses of discrete water samples to data from electronic packages of hydrographic and optics sensors. In addition, a range of biological and geochemical rate measurements are conducted that integrate over time-periods of minutes to days. This sampling strategy yields a reasonable resolution of the major seasonal patterns and of decadal scale variability. The Sargasso Sea also has a variety of episodic production events on scales of days to weeks and these are only poorly resolved. In addition, there is a substantial amount of mesoscale variability in this region and some of the perceived temporal patterns are caused by the intersection of the biweekly sampling with the natural spatial variability. In the Bermuda time-series programs, we have added a series of additional cruises to begin to assess these other sources of variation and their impacts on the interpretation of the main time-series record. However, the adequate resolution of higher frequency temporal patterns will probably require the introduction of new sampling strategies and some emerging technologies such as biogeochemical moorings and autonomous underwater vehicles.

Michaels, Anthony F.↗

The development and testing of a volatile organics concentrator for use in monitoring Space Station water quality

The Volatile Organics Concentrator (VOC) system, designed to attach to a gas chromatograph/mass spectrometer (GC/MS) for the analyses of volatile organic compounds in water on Space Station Freedom, is described. Organic volatiles are collected and concentrated in the VOC by means of two primary solid sorbent tubes and desorbed into the GC/MS system. The paper describes the results of testing the VOC breadboard using a GC/MS system. Evaluations performed on 39 organic compounds recovered from water samples were compared with data for these compounds using direct injection/GC/MS and purge and trap/GC/MS procedures. The results demonstrate that the VOC/GC/MS system's detection limits for the 39 compounds analyzed are comparable to those of the EPA Method 524.2, and for many compounds reaching a factor of 5 lower.

Bodek, Itamar↗

Acetate concentrations and oxidation in salt marsh sediments

Acetate concentrations and rates of acetate oxidation and sulfate reduction were measured in S. alterniflora sediments in New Hampshire and Massachusetts. Pore water extracted from cores by squeezing or centrifugation contained in greater than 0.1 mM acetate and, in some instances, greater than 1.0 mM. Pore water sampled nondestructively contained much less acetate, often less than 0.01 mM. Acetate was associated with roots, and concentrations varied with changes in plant physiology. Acetate turnover was very low whether whole core or slurry incubations were used. Radiotracers injected directly into soils yielded rates of sulfate reduction and acetate oxidation not significantly different from core incubation techniques. Regardless of incubation method, acetate oxidation did not account for a substantial percentage of sulfate reduction. These results differ markedly from data for unvegetated coastal sediments where acetate levels are low, oxidation rate constants are high, and acetate oxication rates greatly exceed rates of sulfate reduction. The discrepancy between rates of acetate oxidation and sulfate reduction in these marsh soils may be due either to the utilization of substrates other than acetate by sulfate reducers or artifacts associated with measurements of organic utilization by rhizosphere bacteria. Care must be taken when interpreting data from salt marsh sediments since the release of material from roots during coring may affect the concentrations of certain compounds as well as influencing results obtained when sediment incubations are employed.

Source record↗

STS-81 Flight Day 7

On this seventh first day of the STS-81 mission, the flight crew, Cmdr. Michael A. Baker, Pilot Brent W. Jett, Mission Specialists, John M. Grunsfeld, Marsha S. Ivins, Peter J.K. Wisoff, and John Blaha, and the cosmonauts of the Russian Space Station Mir continue to transfer hundreds of pounds of water, supplies, and logistical items to each other's spacecraft. More than 1,300 pounds of water have now been transferred from Atlantis to the Mir to resupply the Russian outpost, along with equipment that will be used by astronaut Jerry M. Linenger during his four-month research mission. A bioprocessing device and an experiment used to grow cartilage cells during astronaut John Blaha's four month stay on the Mir is also transferred to Atlantis for the trip back to Earth. Linenger spends most of the day collecting water samples from the Mir for analysis back on Earth and Blaha continues to exercise on a treadmill on the Mir to stay in shape for his return to Earth and a readaptation to gravity after four months of weightlessness.

Source record↗

An Advanced Approach to Simultaneous Monitoring of Multiple Bacteria in Space

The utility of a novel microarray-based microbial analyzer was demonstrated by the rapid detection, imaging, and identification of a mixture of microorganisms found in a waste water sample from the Lunar-Mars Life Support Test Project through the synergistic combination of: (1) judicious RNA probe selection via algorithms developed by University of Houston scientists; (2) tuned surface chemistries developed by Baylor College of Medicine scientists to facilitate hybridization of rRNA targets to DNA probes under very low salt conditions, thereby minimizing secondary structure; and (3) integration of the microarray printing and detection/imaging instrumentation by Genometrix to complete the quantitative analysis of microorganism mixtures.

Eggers, M.↗

Effects of Melt Processing on Evolution of Structure in PEEK

We report on the effects of melt processing temperature on structure formation in Poly(ether-ether-ketone), PEEK. Real time Small Angle X-ray Scattering, SAXS, and thermal analysis are used to follow the melting behavior after various stages of processing. Assignment of peaks to structural entities within the material, the relative perfection of the crystals, and the possibility of their reorganization, are all influenced by the melt processing history. With the advent of high intensity synchrotron sources of X-radiation, polymer scientists gain a research tool which, when used along with thermal analysis, provides additional structural information about the crystals during growth and subsequent melting. PEEK is an engineering thermoplastic polymer with a very high glass transition temperature (145 C) and crystal melting point (337 C). PEEK has been the subject of recent studies by X-ray scattering in which melt and cold crystallization were followed in real-time. X-ray scattering and thermal studies have been used to address the formation of dual endothermic response which has been variously ascribed to lamellar insertion, dual crystal populations, or melting followed by re-crystallization. Another important issue is whether all of the amorphous phase is located in interlamellar regions, or alternatively whether some is located in "pockets" away from the crystalline lamellar stacks. The interpretation of scattering from lamellar stacks varies depending upon whether such amorphous pockets are formed. Some groups believe all of the amorphous phase is interlamellar. This leads to selection of a smaller thickness for the crystals. Other groups suggest that most amorphous phase is not interlamellar, and this leads to the suggestion that the crystal thickness is larger than the amorphous layer within the stacks. To investigate these ideas, we used SAXS and Differential Scanning Calorimetry to compare results of single and dual stage melt crystallization of PEEK using a treatment scheme involving annealing/crystallization at T(sub a1) followed by annealing at T(sub a2) where either T(sub a1) < T(sub a2) or T(sub a1) > T(sub a2). We proposed a model to explain multiple melting endotherms in PPS, treated according to one or two-stage melt or cold crystallization. Key features of this model are that multiple endotherms: (1) are due to reorganization/recrystallization after cold crystallization; and, (2) are dominated by crystal morphology after melt crystallization at high T. In other words, multiple distinct crystal populations are formed by the latter treatment, leading to observation of multiple melting. PEEK 45OG pellets (ICI Americas) were the starting material for this study. Films were compression molded at 400 C, then quenched to ice water. Samples were heated to 375 C in a Mettler FP80 hot stage and held for three min. to erase crystal seeds before cooling them to T(sub a1) = 280 C . Samples were held at T(sub a2) for a period of time, then immediately heated to 360 C. In the second treatment samples were held at T(sub a1) = 31 C for different crystallization times t(sub c) then cooled to 295 C and held 15 min. In situ (SAXS) experiments were performed at the Brookhaven National Synchrotron Light Source with the sample located inside the Mettler hot stage. The system was equipped with a two-dimensional position sensitive detector. The sample to detector distance was 172.7 cm and the X-ray wavelength was 1.54 Angstroms. SAXS data were taken continuously during the isothermal periods and during the heating to 360 C at 5 C/min. Each SAXS scan was collected for 30 sec. Since the samples were isotropic, circular integration was used to increase the signal to noise ratio. After dual stage melt crystallization with T(sub a1) < T(sub a2) the lower melting endotherm arises from holding at T(sub a1). During cooling a broad distribution of crystals forms, and the low-melting tail is perfected during T(sub al). Heating to T(sub a2) melts these imperfect crystals and allows others with greater average long spacing to form in their place. After dual stage crystallization with T(sub a1) > T(sub a2), the amount of space remaining for additional growth at T(sub a2) depends upon the holding time at T(sub a1). The long period of crystals formed at T(sub a2) is smaller than that formed at T(sub a1) due to growth in a now-restricted geometry. Perfection of crystals is seen as an increase of the intensity of the population scattering at higher s, while the intensity of the population scattering at lower s stays constant. During heating from below to above the minor endotherm, we see rapid decrease of the intensity of the X-ray scattering corresponding to the population of crystals scattering in the shoulder. Another important observation is that after the sample is annealed at 295 C, the shoulder intensity is restored once again. The population scattering at higher s remains longer before it disappears in the sample treated to the second stage of melt crystallization, compared to the sample crystallized with a single stage. This could be interpreted as an effect of continued perfection of the less perfect population, which is also reflected in the increased melting temperature of the smaller endotherm as the holding time at 295 C increases. In the corresponding DSC scans we see a shift in the area and the peak temperature of the lower melting endotherm with an increase of the annealing time.

Georgiev, Georgi↗

Ocean Optics Protocols for Satellite Ocean Color Sensor Validation

The document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. This document supersedes the earlier version (Mueller and Austin 1995) published as Volume 25 in the SeaWiFS Technical Report Series. This document marks a significant departure from, and improvement on, theformat and content of Mueller and Austin (1995). The authorship of the protocols has been greatly broadened to include experts specializing in some key areas. New chapters have been added to provide detailed and comprehensive protocols for stability monitoring of radiometers using portable sources, abovewater measurements of remote-sensing reflectance, spectral absorption measurements for discrete water samples, HPLC pigment analysis and fluorometric pigment analysis. Protocols were included in Mueller and Austin (1995) for each of these areas, but the new treatment makes significant advances in each topic area. There are also new chapters prescribing protocols for calibration of sun photometers and sky radiance sensors, sun photometer and sky radiance measurements and analysis, and data archival. These topic areas were barely mentioned in Mueller and Austin (1995).

Fargion, Giulietta S.↗

PHILLS Vicarious Calibration: A WFS Experiment and Guidance for LEO-15 Calibration Efforts

On April 24, 2001, Florida Shelf Lagrangian Experiment (FSLE) cruises were accompanied by PHILLS hyperspectral overflights at 30,000 ft altitude. Robert Steward, and Jim Ivey collected remote sensing reflectance and water samples for absorption during two FSLE experiments. The PHILLS was flown on several transects over the area with vicarious calibration measurements conducted by USF from the R/V LINK. The USF slow-drop package was also deployed to collect inherent and apparent optical properties as a function of depth for an evaluation of effects of vertical structure on remote sensing spectra. The PHILLS imagery has been successfully calibrated. We show the procedures, results, derived bathymetry, and some noise effects with a 3 s period.

Carder, Kendall L.↗

Application of Colorimetric Solid Phase Extraction (C-SPE) to Monitoring Nickel(II) and Lead(II) in Spacecraft Water Supplies

Archived water samples collected on the International Space Station (ISS) and returned to Earth for analysis have, in a few instances, contained trace levels of heavy metals. Building on our previous advances using Colorimetric Solid Phase Extraction (C-SPE) as a biocide monitoring technique, we are devising methods for the low level monitoring of nickel(II), lead(II) and other heavy metals. C-SPE is a sorption-spectrophotometric platform based on the extraction of analytes onto a membrane impregnated with a colorimetric reagent that are then quantified on the surface of the membrane using a diffuse reflectance spectrophotometer. Along these lines, we have determined nickel(II) via complexation with dimethylglyoxime (DMG) and begun to examine the analysis of lead(II) by its reaction with 2,5- dimercapto-1,3,4-thiadiazole (DMTD) and 4-(2- pyridylazo)-resorcinol (PAR). These developments are also extending a new variant of C-SPE in which immobilized reagents are being incorporated into this methodology in order to optimize sample reaction conditions and to introduce the colorimetric reagent. This paper describes the status of our development of these two new methods.

Diaz, Neil C.↗

Nanofluidic size exclusion chromatograph for in site macrometer analyses

We are developing a nanofluidic size exclusion chromatograph system that can be incorporated into a miniature lab-on-a-chip devices which will provide detailed information on the geochemical and biological history of soil, ice, and water samples by identifying and qualifying a broad range of macromolecular polar and nonpolar organic compounds.

size exclusion chromatograph↗

Absorption and Attenuation Coefficients Using the WET Labs ac-s in the Mid-Atlantic Bight: Field Measurements and Data Analysis

Ocean color algorithms are based on the parameterization of apparent optical properties as a function of inherent optical properties. WET Labs underwater absorption and attenuation meters (ac-9 and ac-s) measure both the spectral beam attenuation [c (lambda)] and absorption coefficient [a (lambda)]. The ac-s reports in a continuous range of 390-750 nm with a band pass of 4 nm, totaling approximately 83 distinct wavelengths, while the ac-9 reports at 9 wavelengths. We performed the ac-s field measurements at nine stations in the Mid-Atlantic Bight from water calibrations to data analysis. Onboard the ship, the ac-s was calibrated daily using Milli Q-water. Corrections for the in situ temperature and salinity effects on optical properties of water were applied. Corrections for incomplete recovery of the scattered light in the ac-s absorption tube were performed. The fine scale of spectral and vertical distributions of c (lambda) and a (lambda) were described from the ac-s. The significant relationships between a (674) and that of spectrophotometric analysis and chlorophyll a concentration of discrete water samples were observed.

Ohi, Nobuaki↗

Analysis of N-Nitrosodimethylamine and N-Nitrodimethylamine in Groundwater

A method for the analytical determination of N-nitrosodimethylamine (NDMA) and N-nitrodimethylamine (DMN) at parts-per-trillion (ppt) concentrations in groundwater is reported. The method uses a solid phase extraction (SPE) cartridge containing 2 g of activated coconut charcoal to extract a 500-mL water sample. NDMA and DMN are eluted from the SPE cartridge using acetone. The acetone is concentrated and brought to a final volume of 1.0 mL, which results in a theoretical 500-fold concentration of the analytes. The extracts are analyzed by gas chromatography (GC) with a nitrogenphosphorous detector (NPD), which is a highly sensitive and relatively inexpensive technique. The measured extraction efficiencies averaged 61 percent for NDMA and 74 percent for DMN. Extraction efficiencies were independent of NDMA and DMN concentrations from 40 to 2000 ppt. Several samples could be extracted then analyzed in a single day with the use of an extraction manifold and GC autosampler. A reporting limit of 10 ppt for NDMA and DMN was achieved. The MDLs for NDMA and DMN were 6.4 and 5.8 ppt, respectively. A typical turn-around time from beginning of extraction to reporting was 4 h. The method avoids the use of halogenated solvents, such as dichloromethane, and subsequent solvent exchange procedures necessary for use of the NPD detector.

Greene, Ben↗

Ion-Exclusion Chromatography for Analyzing Organics in Water

A liquid-chromatography technique has been developed for use in the quantitative analysis of urea (and of other nonvolatile organic compounds typically found with urea) dissolved in water. The technique involves the use of a column that contains an ion-exclusion resin; heretofore, this column has been sold for use in analyzing monosaccharides and food softeners, but not for analyzing water supplies. The prior technique commonly used to analyze water for urea content has been one of high-performance liquid chromatography (HPLC), with reliance on hydrophobic interactions between analytes in a water sample and long-chain alkyl groups bonded to an HPLC column. The prior technique has proven inadequate because of a strong tendency toward co-elution of urea with other compounds. Co-elution often causes the urea and other compounds to be crowded into a narrow region of the chromatogram (see left part of figure), thereby giving rise to low chromatographic resolution and misidentification of compounds. It is possible to quantitate urea or another analyte via ultraviolet- and visible-light absorbance measurements, but in order to perform such measurements, it is necessary to dilute the sample, causing a significant loss of sensitivity. The ion-exclusion resin used in the improved technique is sulfonated polystyrene in the calcium form. Whereas the alkyl-chain column used in the prior technique separates compounds on the basis of polarity only, the ion-exclusion-resin column used in the improved technique separates compounds on the basis of both molecular size and electric charge. As a result, the degree of separation is increased: instead of being crowded together into a single chromatographic peak only about 1 to 2 minutes wide as in the prior technique, the chromatographic peaks of different compounds are now separated from each other and spread out over a range about 33 minutes wide (see right part of figure), and the urea peak can readily be distinguished from the other peaks. Although the analysis takes more time in the improved technique, this disadvantage is offset by two important advantages: Sensitivity is increased. The minimum concentration of urea that can be measured is reduced (to between 1/5 and 1/3 of that of the prior technique) because it is not necessary to dilute the sample. The separation of peaks facilitates the identification and quantitation of the various compounds. The resolution of the compounds other than urea makes it possible to identify those compounds by use of mass spectrometry.

Sauer, Richard↗

Discovery and Identification of Dimethylsilanediol as a Contaminant in ISS Potable Water

In September of 2010, analysis of ISS potable water samples was undertaken to determine the contaminant responsible for a rise in total organic carbon (TOC). As analysis of the routine target list of organic compounds did not reveal the contaminant, efforts to look for unknown compounds was initiated, resulting in an unknown peak being discovered in the gas chromatography/mass spectrometry (GC/MS) analysis for glycols. A mass spectrum of the contaminant was then generated by concentrating one of the samples by evaporation and analyzing by GC/MS in full-scan mode. Although a computer match of the compound s identity could not be obtained with the instrument s database, a search with a more up to date mass spectral library yielded a good match with dimethylsilanediol (DMSD). Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) analyses showed abnormally high silicon levels in the samples, confirming that the unknown contained silicon. DMSD was then synthesized to confirm the identification and provide a standard to develop a calibration curve. Further confirmation was provided by external Direct Analysis in Real Time (DART) GC/MS analysis. A preliminary GC/MS method was then developed and archived samples from various locations on ISS were analyzed to determine the extent of the contamination and provide data for troubleshooting. This paper describes these events in more detail as well as problems encountered in routine GC/MS analyses and the subsequent development of high performance liquid chromatography and LC/MS/MS methods for quantitation of DMSD.

Rutz, Jeffrey A.↗

The Development of a CO2 Test Capability in the NASA JSC ARCJet for Mars Reentry Simulation

The Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF) located at NASA Johnson Space Center is used for simulating the extreme environment experienced upon reentry for the development and certification of thermal protection systems (TPS). The facility supports a large variety of programs and was heavily leveraged for the certification and operational support of the TPS for the Orbiter and, more recently, the development of the heat shield for CEV. This paper will provide more detail into the heritage of the facility. Unique attributes of the facility include a modular aerodynamically stabilized arc heater and independently controlled O2 and N2 for the test gases. When combining the O2 and N2 in a 23:77 mass ratio respectively the Earth s atmosphere is accurately simulated and via modification of this ratio the investigation of the effects of atomic oxygen on a material s response is possible. In the summer of 2010 a development effort was started to add CO2 as a third independently controlled test gas such that, when combined with N2, opens up the possibility of accurately simulating a Martian reentry environment. This paper will discuss the test facility, especially the arc heater, in more detail. Initial testing involved relatively low concentrations of CO2 combined with N2 for the primary purpose of gathering data to answer two pressing safety concerns. The first being the rate of production of carbon monoxide (CO) within the ejector vacuum system. The main concern was that CO can be flammable and possibly explosive at high enough concentrations and pressures. The hazard control during the development phase involved the use of injecting N2 inside the test chamber diffuser to dilute and reduce the concentration of any and all CO present. A residual gas analyzer (RGA) was used to determine the relative amount of CO in the exhaust gas and provide a conversion rate of CO2 to CO. This paper will discuss in more detail the results of the RGA data and the calculated conversion rate. The second safety concern addressed is the possible formation of hydrogen cyanide (HCN) and cyanide (CN). HCN would primarily be present in the cooling water while the CN would most probably condense onto the interior surfaces of the test chamber. Water samples and wipes of the test chamber surfaces were analyzed by an industrial hygienist for the presence of HCN and CN. His paper will discuss these results in more detail. Throughout this development effort measurements of the CO2:N2 flowfield were made with heat flux and pressure probes and with laser induced fluorescence (LIF) of the atomic oxygen. This paper will discuss these results

DelPapa, Steven V.↗

Automated Miniaturized Instrument for Space Biology Applications and the Monitoring of the Astronauts Health Onboard the ISS

Human space travelers experience a unique environment that affects homeostasis and physiologic adaptation. The spacecraft environment subjects the traveler to noise, chemical and microbiological contaminants, increased radiation, and variable gravity forces. As humans prepare for long-duration missions to the International Space Station (ISS) and beyond, effective measures must be developed, verified and implemented to ensure mission success. Limited biomedical quantitative capabilities are currently available onboard the ISS. Therefore, the development of versatile instruments to perform space biological analysis and to monitor astronauts' health is needed. We are developing a fully automated, miniaturized system for measuring gene expression on small spacecraft in order to better understand the influence of the space environment on biological systems. This low-cost, low-power, multi-purpose instrument represents a major scientific and technological advancement by providing data on cellular metabolism and regulation. The current system will support growth of microorganisms, extract and purify the RNA, hybridize it to the array, read the expression levels of a large number of genes by microarray analysis, and transmit the measurements to Earth. The system will help discover how bacteria develop resistance to antibiotics and how pathogenic bacteria sometimes increase their virulence in space, facilitating the development of adequate countermeasures to decrease risks associated with human spaceflight. The current stand-alone technology could be used as an integrated platform onboard the ISS to perform similar genetic analyses on any biological systems from the tree of life. Additionally, with some modification the system could be implemented to perform real-time in-situ microbial monitoring of the ISS environment (air, surface and water samples) and the astronaut's microbiome using 16SrRNA microarray technology. Furthermore, the current system can be enhanced substantially by combining it with other technologies for automated, miniaturized, high-throughput biological measurements, such as fast sequencing, protein identification (proteomics) and metabolite profiling (metabolomics). Thus, the system can be integrated with other biomedical instruments in order to support and enhance telemedicine capability onboard ISS. NASA's mission includes sustained investment in critical research leading to effective countermeasures to minimize the risks associated with human spaceflight, and the use of appropriate technology to sustain space exploration at reasonable cost. Our integrated microarray technology is expected to fulfill these two critical requirements and to enable the scientific community to better understand and monitor the effects of the space environment on microorganisms and on the astronaut, in the process leveraging current capabilities and overcoming present limitations.

Human space travelers↗

Bubbles on Enceladus

Saturn’s icy moon, Enceladus, ejects frozen particles consisting of water and salts indicative of a subsurface ocean. Believed to originate from hydrothermal reactions near the core, the subsequent pressure drop generates boiling liquids that erupt and expand out of the tiger stripes. The purpose of this research is to simulate the ongoing geyser activity of Enceladus in the lab and to explore the concentrations of biomass which could exist in geyser bubbles as compared to ejected particles. We tested variance of intensity of light absorbed from the bubbles at different heights of the simulated plume. Anazodye, Allura Red, is a complex organic that will act as a tracer molecule allowing for quantitative analysis of light absorption through a spectrophotometer. Theazodye in combination with water is ejected from a water chamber using compressed air to simulate bubbles forming and a jet erupting from a body of water. Samples were taken of the bubbles at varying heights of the simulated plume as analogs to the Enceladus geysers. This research will provide quantitative analog information on rising bubbles from the ocean of Enceladus which can be applied directly to the practical concern of measuring biomass in the plume.

tiger stripes↗

Portable Electron Microscopy for ISS and Beyond

Advances in space exploration have evolved in lockstep with key technology advances in diverse fields such as materials science, biological science, and engineering risk management. Research in these areas, where structure and physical processes come together, can proceed rapidly in part due to sophisticated ground-based analytical tools that help re-searchers develop technologies and engineering processes that push frontiers of human space exploration. Electron microscopes (EM) are an example of such a workhorse tool, lending a unique blend of strong optical scattering, high native resolution, large depth of focus, and spectroscopy via characteristic X-ray emission, providing exquisite high-magnification structural imaging and chemical analysis. Ground-based EM’s have been essential in NASA research for many years. In particular, in mineralogy and petrology, EM is used to understand the origin and evolution of the solar system, particularly rocky bodies. In microbiology, EM has helped visualize the architecture of tissues and cells. In engineering/materials science, EM has been used to characterize particulate debris in air and water samples, determine pore sizes in ceramics/catalysts, understand the nature of fibers, determine composition and morphology of new and existing materials, and characterize micro-textures of vapor deposited films. EM is highly effective at investigating a wide variety of nanoscale materials/biomaterials at the core of many of NASA’s inquiries. Despite exquisite optical performance and versatility, EM’s are traditionally large, heavy, and have high power consumption. They are also expensive so they tend to be housed at universities and large research institutions, or at major industrial laboratory sites with support staff, supplies, and skilled operators. Since most organizations cannot support their own EM, samples are often sent to these large institutions and service centers to be imaged, at great expense and of-ten with delay of weeks to months for complex analyses. Complexity, high cost, and maintenance associated with collecting EM image data has until now severely limited fields in which EM is used. Making EM accessible outside constrained terrestrial laboratory environments will bring EM’s performance and versatility to a much broader range of scientific and engineering endeavors, including in space.

Own, C. S.↗