Search NASA⌕ Search

SEARCH · Search NASA

Results for “water temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Infrared thermometry in high temperature materials processing: influence of liquid water and steam

Here, the capability of four infrared thermometry techniques (2-colour and 1-colour pyrometers, Pyrolaser and IR camera) was evaluated with respect to the impact of water or steam in the line of sight to determine temperature from two heat sources (blackbody calibration source and steel block inside the furnace). The influence of liquid water on the temperature readings was minimal when using 2-colour pyrometry due to comparable absorption coefficients of water for the measured wavelengths. The signals measured using both the Pyrolaser and the 1-colour pyrometer were decreased due to the partial absorption and resulted in an apparent temperature lower than the actual. Water readily absorbed the IR signal in the range of the IR camera operation, resulting in no signal whenever liquid water was present in the line of sight. Steam caused the most deviation and fluctuation of temperature readings for all techniques due to the large level of light scattering in addition to the absorption of the radiant energy. A technique was developed to determine the transmissivity (apparent emissivity) when water or steam is in the line of sight of measurement. An approximate correction to the measurements based on Planck’s law is discussed for both 2-colour and 1-colour pyrometers.

2-colour and 1-colour pyrometry↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Measuring Climate and Water Risk across the Bulk Power System

As climate impacts increase and power systems transition to renewables, planners and operators need insights into climate risks to power generation and infrastructure to ensure reliable decision-making in the short and long-term. We present a standardized, consistent mechanism for utilities and system operators to evaluate the climate- and water-related risks of their current and future grid assets. Using a risk-based approach on the combined outcomes of high-fidelity climate drivers together with water and power system models, we examine the temperature and water availability impacts within the contiguous United States to power system assets at the water basin level in three different time periods and report resulting outcomes on lost capacity across different expansion scenarios and climate models. The results indicate that air temperature has the highest effect on derating. Changes in streamflow do not have a large impact on generation capacity at the national level. Electric sector buildout scenarios each have a unique regional risk profile, depending on the technology mix and total capacity, although risks from high temperatures are significant for both traditional and renewable energy generation. Stakeholders can use this approach to monitor effects of generation capacity losses and potential impacts as climate, generation mix, and infrastructure change.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Translational diffusion in supercooled water at and near the glass transition temperature—136 K

The properties of amorphous solid water at and near the calorimetric glass transition temperature, T g , of 136 K have been debated for years. One hypothesis is that water turns into a “true” liquid at T g (i.e., it becomes ergodic) and exhibits all the characteristics of an ergodic liquid, including translational diffusion. A competing hypothesis is that only rotational motion becomes active at T g , while the “real” glass transition in water is at a considerably higher temperature. To address this dispute, we have investigated the diffusive mixing in nanoscale water films, with thicknesses up to ∼100 nm, using infrared (IR) spectroscopy. The experiments used films that were composed of at least 90% H 2 O with D 2 O making up the balance and were conducted under conditions where H/D exchange was essentially eliminated. Because the IR spectra of multilayer D 2 O films (e.g., thicknesses of ∼3–6 nm) embedded within thick H 2 O films are distinct from the spectrum of isolated D 2 O molecules within H 2 O, the diffusive mixing of (initially) isotopically layered water films could be followed as a function of annealing time and temperature. The results show that water films with total thicknesses ranging from ∼20 to 100 nm diffusively mixed prior to crystallization for temperatures between 120 and 144 K. The translational diffusion had an Arrhenius temperature dependence with an activation energy of 40.8 ± 3.5 kJ/mol, which indicates that water at and near T g is a strong liquid. The measured diffusion coefficient at 136 K is 6.25 ± 1.4 × 10 −21 m 2 /s.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulating measurable ecosystem carbon and nitrogen dynamics with the mechanistically defined MEMS 2.0 model

Abstract. For decades, predominant soil biogeochemical models have used conceptual soil organic matter (SOM) pools and only simulated them to a shallow depth in soil. Efforts to overcome these limitations have prompted the development of the new generation SOM models, including MEMS 1.0, which represents measurable biophysical SOM fractions, over the entire root zone, and embodies recent understanding of the processes that govern SOM dynamics. Here we present the result of continued development of the MEMS model, version 2.0. MEMS 2.0 is a full ecosystem model with modules simulating plant growth with above- and belowground inputs, soil water and temperature by layer, decomposition of plant inputs and SOM, and mineralization and immobilization of nitrogen (N). The model simulates two commonly measured SOM pools – particulate and mineral-associated organic matter (POM and MAOM, respectively). We present results of calibration and validation of the model with several grassland sites in the US. MEMS 2.0 generally captured the soil carbon (C) stocks (R2 of 0.89 and 0.6 for calibration and validation, respectively) and their distributions between POM and MAOM throughout the entire soil profile. The simulated soil N matches measurements but with lower accuracy (R2 of 0.73 and 0.31 for calibration and validation of total N in SOM, respectively) than for soil C. Simulated soil water and temperature were compared with measurements, and the accuracy is comparable to the other commonly used models. The seasonal variation in gross primary production (GPP; R2 = 0.83), ecosystem respiration (ER; R2 = 0.89), net ecosystem exchange (NEE; R2 = 0.67), and evapotranspiration (ET; R2 = 0.71) was well captured by the model. We will further develop the model to represent forest and agricultural systems and improve it to incorporate new understanding of SOM decomposition.

54 ENVIRONMENTAL SCIENCES↗

Integrated hydrological, power system and economic modelling of climate impacts on electricity demand and cost

Impacts of climate-related water stress and temperature changes can cascade through energy systems, although models have yet to capture this compounding of effects. Here, we employ a coupled water–power–economy model to capture these important interactions in a study of the exceedance of water temperature thresholds for power generation in the western United States. We find that not all reductions in reserve electricity-generation capacity result in impacts, and that when they occur, intermittent interruptions in electricity supply at critical times of the day, week and year account for much of the economic impacts. Finally, we find that impacts may be in different locations from the original water stress. Herein, we estimate that the consumption loss can be up to 0.3% annually and the drivers identified in coupled modelling can increase the average cost of electricity by up to 3%. Integrated models will be needed to capture the cascading effects of climate change through climatic, water, energy and economic systems. Webster et al. now develop a coupled hydrologic–power-production–economic model to estimate water-stress impacts on electricity cost.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Uncertainties in turbulent statistics and fluxes of CO2 associated with density effect corrections

Density effect corrections (DEC) are applied to adjust raw CO2 fluxes measured by eddy covariance (EC) systems with open-path gas analyzers. DEC is also required for adjusting the measured CO2 concentration fluctuations to obtain the adjusted CO2 for analyzing turbulent statistics or quantifying fluxes. However, our data show that the power spectra of the DEC-adjusted CO2 are distorted in the high frequency range, as compared with the corresponding spectra of temperature and water vapor density. This contradicts the similarity behavior of scalars, as suggested by Monin-Obukhov similarity theory. It is demonstrated that such a distortion is caused by the DEC-induced spikes in the DEC-adjusted CO2, altering turbulent statistics of CO2 and scalar similarity between CO2 and other scalars. Our results suggest that CO2 fluxes are overestimated by applying DEC especially under high Bowen ratio conditions, potentially leading to substantial uncertainties in long-term ecosystem carbon exchange in dry regions.

Gao, Zhongming↗

Retrieval of temperature and humidity profiles from ground-based high-resolution infrared observations using an adaptive fast iterative algorithm

Various retrieval algorithms have been developed for retrieving temperature and water vapor profiles from Atmospheric Emitted Radiance Interferometer (AERI) observations. The physical retrieval algorithm, named AERI Optimal Estimation (AERIoe), outperforms other retrieval algorithms in many aspects except the retrieval time, which is significantly increased due to the complex radiative transfer process. The calculation of the Jacobian matrix is the most computationally intensive step of the physical retrieval algorithm. Interestingly, an analysis of the change in AERI observations' information content with respect to Jacobians revealed that the AERIoe algorithm's performance presents negligible dependence on these metrics. Thus, the Jacobian matrix could remain unchanged when the variation in the atmospheric state is small in the retrieval process to reduce the most time-consuming computation. On the basis of the above findings, a fast physical–iterative retrieval algorithm was proposed by adaptively recalculating Jacobians in keeping with the changes in the atmospheric state. Experiments with synthetic observations demonstrate that the proposed method experiences an average reduction in retrieval time by an impressive 59 % compared to the original AERIoe algorithm while achieving maximum root-mean-square errors of less than 0.95 K and 0.22 log(ppmv) for heights below 3 km for the temperature and water vapor profile, respectively. Further analyses revealed that the fast-retrieval algorithm reached an acceptable convergence rate of 98.7 %, marginally lower than AERIoe's 99.9 % convergence rate for the 826 cases used in this study.

54 ENVIRONMENTAL SCIENCES↗

Temperature effects on adsorption and capillarity water retention mechanisms in constrained unsaturated soils

Abstract This paper focuses on the impact of elevated temperatures on the adsorptive and capillarity water retention mechanisms of unsaturated soils under constrained (constant volume) conditions. This topic is critical for simulating the thermo-hydraulic behavior of soils in hydrogeological or geotechnical applications, including climate change effects on near surface soils, energy piles or soil borehole thermal energy storage systems in unsaturated soil layers, and buffers for geological nuclear waste repositories. A nonisothermal soil water retention curve (SWRC) that separately considers the temperature-dependency of the key parameters governing adsorptive and capillarity water retention mechanisms and soil physical parameters (e.g., surface tension, contact angle, adsorption capacity, cation exchange capacity, mean cavitation suction, air entry value and equilibrium film thickness) was developed to provide insights into the impact of temperature on water retention over the full suction range. The nonisothermal SWRC was validated using experimental data on high plasticity clays, with a good prediction of temperature effects on adsorption and capillarity water retention mechanisms in constrained unsaturated soils.

Lu, Yu↗

Lithium substituted poly(amic acid) as a water-soluble anode binder for high-temperature pre-lithiation

Multifunctional binders hold great promise in advanced electrode designs for both fundamental research and practical utilization of lithium-ion batteries (LIBs). The reactions between Si/SiO x -dominated anodes with lithium are expected to be exothermic in principle, while the thermal tolerance along with the volume change makes high-temperature binders attractive for large scale roll-to-roll manufacturing. For instance, if a high temperature binder is also water soluble, it can be compatible with the current graphite-based anode manufacturing process. In this work, we present a water-soluble poly(amic acid)-based binder, which can withstand high temperature for industrial pre-lithiation process and effectively hold active materials together during repeated charge and discharge cycles. This lithium substituted poly(amic acid) binder (denoted as Li-Pa) can serve as a drop-in replacement for environmentally friendly electrode fabrication in large scale by providing aqueous solubility, exceptional thermal stability and mechanical flexibility.

25 ENERGY STORAGE↗

Data for Attributing Differences of Solar-Induced Chlorophyll Fluorescence (SIF)-Gross Primary Production (GPP) Relationships between Two C4 Crops, Corn and Miscanthus

Information to characterize the solar-induced chlorophyll fluorescence (SIF)-gross primary production (GPP) relationship in C4 cropping systems remains limited. The annual C4 crop corn and perennial C4 crop miscanthus differ in phenology, canopy structure and leaf physiology. Investigating the SIF-GPP relationships in these species could deepen our understanding of SIF-GPP relationships within C4 crops. Using in situ canopy SIF and GPP measurements for both species along with leaf-level measurements, we found considerable differences in the SIF-GPP relationships between corn and miscanthus, with a stronger SIF-GPP relationship and higher slope of SIF-GPP observed in corn compared to miscanthus. These differences were mainly caused by leaf physiology. For miscanthus, high non-photochemical quenching (NPQ) under high light, temperature and water vapor deficit (VPD) conditions caused a large decline of fluorescence yield (ΦF), which further led to a SIF midday depression and weakened the SIF-GPP relationship. The larger slope in corn than miscanthus was mainly due to its higher GPP in mid-summer, largely attributed to the higher leaf photosynthesis and less NPQ. Our results demonstrated variation of the SIF-GPP relationship within C4 crops and highlighted the importance of leaf physiology in determining canopy SIF behaviors and SIF-GPP relationships.

Feedstock Production↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Temperature response and brine availability to heated boreholes in bedded salt

Abstract There is a growing need for disposal of high‐level nuclear waste. To reduce uncertainty associated with brine availability to repository excavations in salt formations, a collaboration between Sandia, Los Alamos, and Lawrence Berkeley National Laboratories is performing a series of borehole‐scale coupled process tests. Here, we report on the first round of the Brine Availability Test in Salt (BATS) project, a “shakedown” experiment called Phase 1s. Experimental testing included placing a resistive heater, a 260‐W radiative heater, and a 750‐W radiative heater within previously drilled horizontal boreholes at the Waste Isolation Pilot Plant (WIPP) while monitoring temperature and water inflow. The experiments successfully achieved the targeted temperature of 120 °C when using the 750‐W radiative heater. Simulations using FEHM (Finite Element Heat and Mass transfer code) and TOUGH‐FLAC (Transport Of Unsaturated Groundwater and Heat–Fast Lagrangian Analysis of Continua) were able to accurately predict the coupled thermo–hydro–mechanical–chemical response of salt, matching the observed temperature and brine production. Due to the extremely low permeability of salt, these systems take many years to reach steady state when perturbed by mining activities. Long‐term numerical simulations are used to develop the initial pressure and saturation conditions. The inclusion of a damaged rock zone with higher permeability around the borehole also affects the saturation and pressure distributions and plays an important role in dissipating the potential for thermal pressurization. Knowledge gained from this round of experimentation and simulation will be used to conduct the next BATS project experiment in new boreholes at WIPP.

58 GEOSCIENCES↗

Interaction of molecular nitrogen with vanadium oxide in the absence and presence of water vapor at room temperature: Near-ambient pressure XPS

Interactions of N2 at oxide surfaces are important for understanding electrocatalytic nitrogen reduction reaction (NRR) mechanisms. Interactions of N2 at the polycrystalline vanadium oxide/vapor interface were monitored at room temperature and total pressures up to 10−1 Torr using Near-Ambient Pressure X-ray Photoelectron Spectroscopy (NAP-XPS). The oxide film was predominantly V(IV), with V(III) and V(V) components. XPS spectra were acquired in environments of both pure N2 and equal pressures of N2 and H2O vapor. In pure N2, broad, partially resolved N1s features were observed at binding energies of 401.0 and 398.7 eV, with a relative intensity of ∼3:1, respectively. These features remained upon subsequent pumpdown to 10−9 Torr. The observed maximum N surface coverage was ∼1.5 × 1013 cm−2—a fraction of a monolayer. In the presence of equal pressures of H2O, the adsorbed N intensity at 10−1 Torr is ∼25% of that observed in the absence of H2O. The formation of molecularly adsorbed H2O was also observed. Density functional theory-based calculations suggest favorable absorption energies for N2 bonding to both V(IV) and V(III) cation sites but less so for V(V) sites. Hartree–Fock-based cluster calculations for N2–V end-on adsorption show that experimental XPS doublet features are consistent with the calculated shake-up and normal, final ionic configurations for N2 end-on bonding to V(III) sites but not V(IV) sites. The XPS spectra of vanadium oxide transferred in situ between electrochemical and UHV environments indicate that the oxide surfaces studied here are stable upon exposure to the electrolyte under NRR-relevant conditions.

Balogun, K.↗

A Study of Cost-Saving Potential of Load Flexibility Measures in Grid-Interactive Multifamily Buildings

With recent advances in smart technologies, more and more smart devices are penetrating the residential and commercial buildings market. The introduction of these smart devices is also helping IoT companies emerge with load aggregator roles in the sector. With more utility companies on the track of supporting OpenADR protocols, the aggregators could play a significant role in providing load flexibilities by automatically responding to demand response (DR) events and coordinating load flexibility measures between customers. This would benefit utility companies by reducing stress on the grid during critical peak demand hours as well as customers by allowing them to utilize utility rate structures advantageous to those able to reduce electric usage during high-demand hours. This study evaluates cost and energy savings from adopting multiple load flexibility measures in multifamily buildings. Combinations of different load flexibility measures, including space temperature floating, light dimming, automatic window shading, and water heater temperature floating, are considered. The simulations are performed using OpenStudio®, an open-source U.S. Department of Energy (DOE) simulation platform. For the case study, we used a midrise apartment building with weather conditions from Denver, Colorado. To compare climate zone differences, simulations were also performed for Los Angeles, California, and Chicago, Illinois. Initial results indicate that the application of automated load flexibility measures without careful consideration of dispatching strategies and DR program enrollments could significantly affect the savings. To get meaningful cost savings, aggregators need to encourage tenant awareness to curtail energy usage through occupant behavior in addition to dispatching automatic load flexibility measures. The outcomes from this study are believed to help load aggregators understand the risks and benefits of load flexibility opportunities.

building energy modeling↗

Effects of Livestock Exclusion on Stream Habitat and Aquatic Biota: A Review and Recommendations for Implementation and Monitoring

Abstract To inform riparian restoration, research, and monitoring and to provide management recommendations, we reviewed published studies evaluating the physical and biological effectiveness of livestock exclusion and grazing reduction on various metrics in riparian and aquatic areas. We identified 95 North American studies that reported the effects of livestock grazing reduction on physical habitat (channel morphology, mesohabitats, substrate, and bank stability), biological assemblages (riparian vegetation, macroinvertebrates, fish, and birds), and water quality metrics (temperature, nitrates, phosphorus, and turbidity). Most studies reported that methods to reduce or exclude livestock decreased channel width, width-to-depth ratio, bank erosion, soil bulk density, bare ground, water temperature, nitrogen, and phosphorus and increased riparian vegetation (cover, height, productivity, biomass, and abundance), riparian bird abundance, and young-of-the-year fishes. Results for channel depth, instream substrate, mesohabitats, water depth, juvenile and adult fishes, and macroinvertebrates showed no consistent response to exclusion. Project success was influenced by the time since exclusion; whether there was complete exclusion or continued grazing; and local climate, geology, and soils. Apart from bank erosion and stability, most of the physical and biological metrics took more than a decade to respond to livestock exclusion. However, coupling exclusion with planting and other restoration measures decreased the recovery time. Complete exclusion of livestock produced more consistent improvements in riparian condition and other metrics than rest–rotation or other grazing management strategies. Understanding how physical and biological metrics respond to livestock exclusion will require (1) focused, long-term studies using before–after or before–after, control–impact designs; and (2) monitoring of metrics that most consistently respond to exclusion. Ultimately, the design of exclusions should be driven by local climate, geology, biophysical conditions, and management history. Our results highlight the need for watershed-scale approaches to excluding livestock from broad areas and the need for implementation monitoring to ensure that fencing and other exclusion measures continue to exclude livestock and produce the desired responses.

Krall, Michelle↗