Search NASA⌕ Search

SEARCH · Search NASA

Results for “weather condition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Convective potential and fuel availability complement near-surface weather in regulating global wildfire activity

Wildfires are favored by hot, dry, windy, rainless conditions—this knowledge about fire weather informs both short-term forecast and long-term prediction of wildfire activity. Yet, wildfires rely on the availability of ignition and fuel, which are underrepresented in fire forecast and prediction practices. By analyzing satellite measurements and atmospheric reanalysis, here we show that near-surface weather only partially captures wildfire occurrence and intensity across the daily to seasonal timescales. Beyond near-surface weather, convection and fuel abundance play a complementary role in regulating burning processes. Specifically, enhanced atmospheric convection is identified for over 40% of the low-human-impact regions and 61% of global burnable areas during wildfire ignition and spreading periods. Meanwhile, 56% of shrublands and 54% of grasslands see higher fuel load with actual occurrence of fire. Our results highlight the role of convection and fuel in wildfire forecast, prompting a revisit of wildfire prediction under intertwined atmospheric and terrestrial changes.

54 ENVIRONMENTAL SCIENCES↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

S0 Uncrewed Aircraft System Measurement Characterization Field Campaign Report

The lower atmosphere contributes directly to the modulation of weather and climate. Understanding the importance of this part of the atmosphere, scientists have worked to improve the representation of the atmospheric boundary layer in numerical prediction tools. Such work depends upon information from observing systems, including remote sensors, weather balloons, and research aircraft. Recent years have seen significant advances in uncrewed aircraft systems (UAS) for atmospheric research. Those efforts have provided new perspectives on atmospheric and surface conditions, particularly from smaller UAS (sUAS) platforms. This field campaign included collection of data using several sUAS, and comparing the sUAS data to those from different observing facilities at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory in Oklahoma. Over the course of one week, the Black Swift Technologies and University of Nebraska teams conducted flights for the sole purpose of system evaluation and intercomparison. In addition, these teams conducted joint flight operations at the Marshall, Oklahoma Mesonet site alongside teams from the University of Colorado, University of Oklahoma, and Oklahoma State University to collect additional data for side-by-side comparison. Platforms operated by Black Swift Technologies and the University of Nebraska under this project included one fixed-wing and two rotary-wing platforms, as well as an instrumented surface vehicle. These include the Black Swift Technologies S0 UAS, the University of Nebraska M600 UAS, a University of Nebraska-operated Meteomatics Meteodrone UAS, and the University of Nebraska CoMeT (Combined Mesonet and Tracker) vehicle. Additional details on all of these platforms can be found in de Boer et al. (in prep). In total, 95 sUAS flights were conducted for a combined total of 18.6 flight hours. The S0 was operated both to the south and north of the SGP 60 m tower, while the M600 and Meteodrone were operated directly to the east of the tower. Weather conditions were generally good, with moderate winds. Flights were conducted both to follow the extra radiosondes that were launched as part of this campaign, as well as to conduct extended statistical sampling at tower instrument heights. The later flights also provided data for statistical platform intercomparison.

54 ENVIRONMENTAL SCIENCES↗

Enhancing Biomass Productivity by Forecast‐Informed Pond Operations

ABSTRACT Microalgal cultivation for biofuels and proteins holds significant promise but faces challenges in achieving economically viable biomass productivity under variable environmental conditions. This study introduces a forecast‐informed pond operation (FIPO) system that uses numerical weather prediction (NWP) ensemble forecasts and the biomass assessment tool (BAT) to optimize daily dilution rates for enhanced biomass production. In contrast to the current practice, where fixed dilution rates are based on operator experience, the FIPO system determines the optimal dilution rate based on future weather forecasts and biomass growth conditions. Our experiments validate the effectiveness of FIPO in both short‐ and long‐term growth scenarios. In short‐term experiments, FIPO increased biomass production by 21.3% compared to batch growth and 7.4% over fixed dilution (60% every 3 days) operations. The NWP forecast‐informed operations achieved biomass production nearly identical to that using perfect weather forecasts, highlighting the accuracy of current NWP forecasts for guiding pond operations. In long‐term experiments, FIPO resulted in biomass production increases of 13.3% and 17.8% compared to two fixed dilution rates (60% every 3 days and 20% daily). These findings underscore the viability of using NWP forecasts to optimize microalgal cultivation systems. By adjusting daily dilution rates in response to forecasted weather, operators can achieve higher biomass yields and mitigate risks associated with environmental variability. This study provides a foundation for future research and practical applications in commercial‐scale microalgal production.

Yan, Hongxiang [Energy and Environment Directorate↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates

Currently, a majority of global residential air-conditioning requirements are met using cooling systems based on the vapor compression cycle (VCC). To meet the future demand for space cooling and to reduce the corresponding environmental impact, there is a need for alternative cooling systems which require less resources and exhibit a higher coefficient of performance (COP). One of proposed alternatives is called the hybrid evaporative-vapor compression (HEVC) cycle, which utilizes adiabatic latent cooling in combination with the VCC. In this paper, we conducted a feasibility analysis of a HEVC system by comparing its performance to that of VCC for various global climates. To accomplish this, we developed and validated models to simulate the performance of residential VCC and HEVC systems. ASHRAE weather data and design conditions were then used to compare the performance of the two systems. In general, HEVC systems are best suited for hot arid climates with energy reduction greater than 20%. Conversely, humid climates are not suitable for HEVC adoption due to degraded performance of evaporative coolers in these climates. In addition to comparing the energy savings from HEVC systems, it is also critical to analyze their water consumption. Generally, climates that benefit the most from HEVC technology tend to also experience water scarcity issues. Thus, both the energy savings and water consumption of HEVC systems must be analyzed to guide the discussion on their adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Historic Significance and Current Condition Assessment of Building 06-CP-170, the Yucca Flat Weather Station, Area 6, Nevada National Security Site, Nye County, Nevada

This report was produced in partial fulfillment of the mitigation of adverse effects to Building 06-CP-170, the Yucca Flat Weather Station on the Nevada National Security Site (NNSS), and is intended to comply with the 2021 Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County, Nevada (hereafter referred to as the MOA). This MOA was executed to resolve adverse effects from the U.S. Department of Energy (DOE) plan to demolish 14 architectural resources at the Control Point and in the vicinity in Area 6 of the NNSS. The management and operations contractor for the NNSS identified these 14 architectural resources as environmental hazards unsafe for human occupation due to deterioration and rodent infestation. Building 06-CP-170 is scheduled for demolition as part of this undertaking. Building 06-CP-170 was originally recorded in 2018 during a Section 106 cultural resources inventory for a proposed installation of a 138-kilovolt transmission line on the NNSS. The building was determined individually eligible by the DOE, in consultation with the Nevada State Historic Preservation Office, for inclusion in the National Register of Historic Places under the Secretary of the Interior’s Significance Criterion A because of its association with nuclear testing. Pursuant to Stipulation III.D.3 of the MOA, this report provides a summary of the historic significance of Building 06-CP-170 and a description of its current condition and accessory resources. In addition, an updated Architectural Resource Assessment (ARA) form with new information and photographs is included in the appendix in fulfillment of Stipulation III.D.2.

54 ENVIRONMENTAL SCIENCES↗

Two Large-Scale Meteorological Patterns are Associated with Short-Duration Dry Spells in the Northeastern United States

Large-scale meteorological pattern (LSMP)–based analysis is used in a novel way to understand meteorological conditions before and during short-duration dry spells over the northeastern United States. These LSMPs are useful to assess models and select better-performing models for future projections. Dry-spell events are identified from histograms of consecutive dry days below a daily precipitation threshold. Events lasting 12 days or longer, which correspond to ~10% of dry-spell events, are examined. The 500-hPa stream-function anomaly fields for the first 12 days of each event are time averaged, and k -means clustering is applied to isolate the dry-spell-related LSMPs. The first cluster has a strong low pressure anomaly over the Atlantic Ocean, southeast of the region, and is more common in winter and spring. The second cluster has strong high pressure over east-central North America and is most common during autumn. Over the region, both clusters have negative specific humidity anomalies, negative integrated vapor transport from the north, and subsidence associated with a midlatitude jet stream dipole structure that reinforces upper-level convergence. Subsidence is supported by cold-air advection in the first cluster and the location on the east side of the lower-level high pressure in the second cluster. Extratropical cyclone storm tracks are generally shifted southward of the region during the dry spells. Individual events lie on a continuum between two distinct clusters. These clusters have similar local, but different remote, properties. Although dry spells occur with greater frequency during drought months, most dry spells occur during nondrought months. Significance Statement: This study examines the large-scale weather patterns and meteorological conditions associated with dry-spell events lasting at least 2 weeks while affecting the northeastern United States. A statistical approach groups events together on the basis of similar atmospheric features. We find two distinct sets of patterns that we call large-scale meteorological patterns. These patterns reduce moisture, foster localized sinking, and shift the storm track southward along the Atlantic seaboard, all of which reduce precipitation. Besides greater understanding, knowing the meteorological patterns during short-term dryness in the region provides an important tool to assess how well atmospheric models reproduce these specific patterns. More dry spells occur in non-drought months than in drought months, which means that dry spells can occur without preexisting drought conditions.

58 GEOSCIENCES↗

SysCaps (Language Interfaces for Simulation Surrogates of Complex Systems) [SWR-24-97]

You've found the official code repository for the paper "SysCaps: Language Interfaces for Simulation Surrogates of Complex Systems," presented at the Foundation Models for Science: Progress, Opportunities, and Challenges workshop at NeurIPS 2024. Our paper conjectures that interfaces (both text templates as well as conversational) makes interacting with simulation surrogate models for complex systems more intuitive and accessible for both non-experts and experts. "System captions", or SysCaps, are text-based descriptions of systems based on information contained in simulation metadata. Our paper's goal is to train multimodal regression models that take text inputs (SysCaps) and timeseries inputs (exogenous system conditions such as hourly weather) and regress timeseries simulation outputs (e.g. hourly building energy consumption). The experiments in our paper with building and wind farm simulators, which can be reproduced using this codebase, aim to help us understand whether a) accurate regression in this setting is possible and b) if so, how well can we do it. Paper: https://arxiv.org/abs/2405.19653

Emami, Patrick↗

An Automated Method for Mapping Giant Kelp Canopy Dynamics from UAV

Satellite and aerial imagery have been used extensively for mapping the abundance and distribution of giant kelp ( Macrocystis pyrifera ) in southern California. There is now great potential for using unoccupied aerial vehicles (UAVs) to map kelp canopy at very high resolutions. However, tides and currents have been shown to affect the amount of floating kelp canopy on the water surface, and the impacts of these processes on remotely sensed kelp estimates in this region have not been fully quantified. UAVs were used to map fine-scale changes in canopy area due to tidal height and current speed at kelp forests off the coast of Palos Verdes, CA and Santa Barbara, CA. An automated method for detecting kelp canopy was developed that was 67% accurate using red-green-blue (RGB) UAV imagery and 93% accurate using multispectral UAV imagery across a range of weather, ocean, and illumination conditions. Increases in tidal height of 1 m reduced the amount of floating kelp canopy by 15% in Santa Barbara and by over 30% in Palos Verdes. The effect of current speed on visible kelp canopy was inconclusive, but there was a trend towards lower canopy area with increased current speed. Therefore, while tidal height and current speed can introduce significant variability to estimates of kelp abundance, the magnitude of this variability is site specific. Still, UAVs are a valuable tool for mapping of kelp canopy and can provide greater spatial resolution and temporal coverage than is possible from many satellite sensors. This data can provide insight into the patterns and drivers of high frequency fluctuations in kelp abundance.

54 ENVIRONMENTAL SCIENCES↗

Lessons Learned from the First Year of Property Remediation - 20475

The Port Hope Area Initiative (PHAI) is a federal environmental clean-up program. Its mandate is the remediation and local, long-term, safe management of approximately 1.7 million cubic metres of historic low-level radioactive waste (LLRW) in the adjacent communities of Port Hope and Port Granby in Southern Ontario, Canada. The PHAI is being undertaken by Canadian Nuclear Laboratories (CNL) on behalf of Atomic Energy of Canada Limited, a federal Crown corporation. It is currently one of the largest environmental remediation projects in Canada. The safety of workers, the public and the environment while delivering the PHAI compliantly, on time and within budget is CNL's number one priority. The PHAI is being carried out as two projects - the Port Hope Project and the Port Granby Project. The larger of the two PHAI scopes of work - the Port Hope Project - involves the cleanup of approximately 1.2 million cubic metres of historic LLRW from 18 major sites in Port Hope, the construction of an engineered aboveground mound where the waste will be safely contained and the long-term maintenance and monitoring of the facility. Construction of the waste water treatment plant, the first three of four cells in the mound and supporting infrastructure is complete, with construction of the fourth cell in progress. In 2017 with the movement of on-site waste at this facility began and is now complete. Waste excavation and transportation from off-site locations within the community began in 2018; the cleanup of four temporary storage sites is now complete and remediation at several other major sites is underway. The Port Hope Project also includes a survey of the interior and exterior investigation of approximately 4,800 properties, primarily residential, in the urban area of Port Hope for the presence or absence of historic LLRW. The current projection is that approximately 1,250 privately owned residential and commercial properties known as Small-Scale Sites (SSS) will be identified as having waste exceeding the PHAI clean-up criteria. This paper will outline some of the challenges and lessons learned from the first year of SSS remediation including contractual, data and design issues; interaction with and managing expectations of stakeholders; weather, site and structure conditions as well as municipal permitting, resourcing, transportation and remediation verification. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Baltimore Community Weather Station Network: Filling the Urban Measurement Desert

Quantification and understanding of how heat, rainfall, and air quality vary within cities are needed to identify the area with the worst conditions, develop solutions to extreme weather, and assess the impact of proposed policies. However, neighborhood-level variability is not well quantified because there are few environmental measurement stations within cities. In Baltimore City, a community-based network of weather stations to address this issue has been developed through a partnership between universities, state agencies, and Baltimore residents. The weather stations are hosted by community partners, and the data collected are enabling the mapping of urban weather across the city and the testing of models and proposed mitigation strategies. In addition, the network provides direct community involvement, with resulting benefits of increased community engagement, education, and empowerment. Researchers have an opportunity to democratize the scientific process and ensure that local knowledge and lived experiences of city residents inform future decision-making. The approach could be used as a model for other cities that apply similar monitoring instruments for other environmental exposures.

community↗

Guideline for Characterizing and Evaluating a Candidate Project Site for Solar Thermal Applications

This document presents a structured procedure for characterizing and evaluating candidate project sites for concentrating solar power (CSP) and solar heat for industrial processes (SHIP) applications. The objective is to provide project developers, researchers, and other stakeholders with a consistent, technology-agnostic framework for early-stage site assessment, enabling informed decision-making prior to significant investment in project development. Site selection is a critical factor in project success or failure for both CSP and SHIP projects. Key factors such as solar resource availability, land characteristics, environmental and regulatory constraints, infrastructure availability, and community context are determined by the choice of project site and can materially impact project performance, cost, schedule, and overall viability. This procedure is designed to systematically evaluate these factors, identify potential fatal flaws, and prioritize the most favorable candidate sites for further development. The process begins with rapid screening-level evaluation, using publicly available data to assess solar resource, land availability and suitability, zoning and land-use compatibility, and exclusion zones such as protected lands or sensitive habitats. Sites that meet the minimum screening criteria advance to a more detailed characterization. Subsequent sections of this report provide guidance for a next-level assessment of the most important technical and environmental parameters, including: 1) Solar resource quality, variability, and uncertainty using multiyear datasets and, where appropriate, on-site measurement campaigns; 2) Meteorological conditions such as wind, temperature, extreme weather events, and soiling impacts; 3) Land characteristics including slope, shading, and geotechnical conditions; and 4) Environmental and regulatory considerations, including permitting processes, endangered species, cultural resources, and visual impacts. The procedure also addresses infrastructure and integration considerations, including: 1) Grid interconnection requirements for CSP power generation projects; 2) Electrical and operational integration for SHIP facilities; 3) Water availability, quality, and permitting constraints, which are particularly critical for CSP in arid regions; and 4) Site access, construction logistics, and availability of workforce and supporting services. Recognizing the importance of social and economic context, the procedure includes evaluation of community engagement factors, such as stakeholder sentiment, proximity to sensitive visual receptors, workforce development opportunities, and local economic incentives. The outputs of these assessments are synthesized in a cost and risk evaluation, translating site characteristics into expected impacts on capital cost, operating cost, schedule, and technical risk. This is complemented by screening-level performance modeling, including 8760 simulations and long-term projections, to quantify expected energy or thermal output, assess variability thereof, and support comparison between candidate sites. Finally, the procedure provides high-level guidance on a structured go/no-go decision framework, categorizing sites based on identified risks and constraints, and outlining a clear path forward to feasibility studies and front-end engineering design for viable projects. By standardizing the site characterization process across both CSP and SHIP applications, this guideline aims to: 1) Improve consistency and transparency in early-stage project evaluation; 2) Reduce development risk and avoid investment in nonviable project sites; 3) Support collaboration between developers, researchers, and public agencies; and 4) Accelerate successful deployment of concentrating solar technologies for both power generation and industrial process heat.

14 SOLAR ENERGY↗

Continental United States climate projections based on thermodynamic modification of historical weather

Abstract Regional climate models can be used to examine how past weather events might unfold under different climate conditions by simulating analogue versions of those events with modified thermodynamic conditions (i.e., warming signals). Here, we apply this approach by dynamically downscaling a 40-year sequence of past weather from 1980–2019 driven by atmospheric re-analysis, and then repeating this 40-year sequence a total of 8 times using a range of time-evolving thermodynamic warming signals that follow 4 80-year future warming trajectories from 2020–2099. Warming signals follow two emission scenarios (SSP585 and SSP245) and are derived from two groups of global climate models based on whether they exhibit relatively high or low climate sensitivity. The resulting dataset, which contains 25 hourly and over 200 3-hourly variables at 12 km spatial resolution, can be used to examine a plausible range of future climate conditions in direct reference to previously observed weather and enables a systematic exploration of the ways in which thermodynamic change influences the characteristics of historical extreme events.

54 ENVIRONMENTAL SCIENCES↗

Building Energy Analysis of Manufactured and Multifamily Housing Types in Juneau, Alaska

This report details the results of building energy modeling analysis evaluating the potential energy savings, economic outcomes, and grid-level electricity reduction associated with cold climate air source heat pump (ccASHP) adoption across multifamily and manufactured housing (MMFH) building typologies in the City and Borough of Juneau (CBJ). Three building archetypes were evaluated: multifamily 4-plex apartments, multifamily 8-plex apartments, and manufactured housing units. Building energy models were developed using OpenStudio-HPXML and calibrated to actual utility consumption data and local meteorological data from the Juneau International Airport weather station using an automated calibration tool following the BPI-2400-S-2015 v.2 standard for model calibration. Occupant behaviors present the greatest variability in successful calibrations. Calibrated models were benchmarked against a baseline electric resistance heating condition, with the selected ccASHP modeled as the retrofit condition and typical meteorological year weather data for all results generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The environmental controls on efficiency of enhanced rock weathering in soils

Abstract Enhanced rock weathering (ERW) in soils is a promising carbon removal technology, but the realistically achievable efficiency, controlled primarily by in situ weathering rates of the applied rocks, is highly uncertain. Here we explored the impacts of coupled biogeochemical and transport processes and a set of primary environmental and operational controls, using forsterite as a proxy mineral in soils and a multiphase multi-component reactive transport model considering microbe-mediated reactions. For a onetime forsterite application of ~ 16 kg/m 2 , complete weathering within five years can be achieved, giving an equivalent carbon removal rate of ~ 2.3 kgCO 2 /m 2 /yr. However, the rate is highly variable based on site-specific conditions. We showed that the in situ weathering rate can be enhanced by conditions and operations that maintain high CO 2 availability via effective transport of atmospheric CO 2 (e.g. in well-drained soils) and/or sufficient biogenic CO 2 supply (e.g. stimulated plant–microbe processes). Our results further highlight that the effect of increasing surface area on weathering rate can be significant—so that the energy penalty of reducing the grain size may be justified—only when CO 2 supply is nonlimiting. Therefore, for ERW practices to be effective, siting and engineering design (e.g. optimal grain size) need to be co-optimized.

54 ENVIRONMENTAL SCIENCES↗