Search NASASearch

SEARCH · Search NASA

Results for “052002* -- Nuclear Fuels-- Waste Disposal & Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

746 records · Page 19

Commercial and Industrial Energy Procurement in Nigeria: A Consumer's Guidebook

Across Africa, countries have incorporated a variety of new energy sources into their energy mix to account for increasing demand. In Nigeria, electricity consumption per capita has grown nearly 50% in the past 20 years. To address rising demand for energy in Nigeria, the country has passed several recent policies and regulations aimed at increasing energy generation across the country, improving the country's transmission infrastructure, and ensuring that electricity reliably reaches end users, including commercial and industrial (C&I) customers. This guidebook is designed for C&I customers in Nigeria to use in the consideration of procuring such onsite, captive energy systems to supplement their energy needs. Each section of this guidebook touches on a step of the procurement process and details the relevant stakeholders, processes, and data needed to make decisions during that step.

14 SOLAR ENERGY

Lunar Nuclear Reactor Neutron Fluence and Gamma Dose Estimates

NASA aims to deploy a fission reactor on the lunar surface by 2030 to generate 100 kWe of power for at least 10 years without maintenance or refueling. To assess system and subsystem survivability according to those requirements, a model of the reactor pallet was created in the radiation transport code MCNP to determine the neutron fluences and gamma doses that the materials and systems would be exposed to. The model was based on the 2025 government design. The model indicated that the control drum motors, Brayton cycle engines, and pipes and valves would be exposed to neutron fluences of 1×10 15 – 1×10 16 n/cm 2 per year and gamma doses ranging from 10 to 500 Mrad per year. The electronics box housing the instrumentation and control elements is expected to receive 1×10 14 – 1×10 15 n/cm 2 per year and gamma doses in the range of 1–5 Mrad per year. These doses necessitate that the control drum motors, Brayton cycle engines, valve components, control electronics, and other components be radiation-hardened (>10 16 n/cm 2 and >10 Mrad gamma dose) or additionally shielded to survive the 10-year lunar mission.

Radiation-Hardened Materials

Hierarchical low Pt-loading “core-shell” electrocatalysts for the oxygen reduction reaction in fuel cells

The sluggish kinetics of the oxygen reduction reaction (ORR) hinder cost-effective polymer electrolyte fuel cells (PEFCs), which rely on scarce, expensive platinum-based electrocatalysts (ECs). Here, we present a novel synthesis method for ORR ECs achieving exceptional platinum utilization. The design features a hierarchical “multi-carbon” support comprising carbon nanoparticles interacting with graphene nanoplatelets as the “core”, encapsulated by a porous carbon nitride (CN) “shell”. This configuration promotes strong core/shell interactions and a bimodal active site distribution, consisting of chemically dispersed Pt and Ni single-atom complexes and PtNix alloy nanoclusters embedded in the CN shell. These advantages enable high activity and durability, achieving an ORR activity of 1.6 A mgPt−1 at 0.9 V vs. RHE-an order of magnitude higher than Pt/C (0.17 A mgPt−1). A proof-of-concept PEFC demonstrates a specific power of 12.0 kW gPt−1 at 0.60 V. This approach offers a significant step toward more efficient and sustainable PEFC technologies.

Pagot, Gioele [University of Padova, Italy]

Comparing the fluorination of Pb+ and Po+: insights into p-block relativistic effects for superheavy elements

It is expected that the chemical properties of the heaviest of the superheavy elements (SHEs, = 113 – 118) do not align with what is suggested by their current positions on the periodic table. Specifically, the onset of significant relativistic effects, including increased spin–orbit splitting of the p-orbitals may lead to enhanced stability of low-oxidation states. Notably, it is predicted that flerovium ( = 114) may exhibit pseudo-noble gas behavior from a electron configuration that acts as an ‘inert pair’. Even though it is expected that the – splitting becomes pronounced toward the end of the p-block’s sixth row, there is currently limited experimental evidence to confirm its extent or impact. Here, the production of gas-phase lead ( = 82) and polonium ( = 84) fluoride cations (PbF and PoF ) were compared to elucidate differences in accessible oxidation states. The PoF and PbF species were produced and identified with the FIONA spectrometer at the Lawrence Berkeley National Laboratory 88-Inch Cylctron Facility. Polonium showed notably different fluorination chemistry than lead, producing PoF and PoF as primary products compared to lead’s PbF and PbF . The distribution of PoF products observed offer insights as to the role of spin–orbit splitting for polonium. Similar studies of superheavy elements would elucidate the accessibility of their low-oxidation states as well as to inform chemical predictions for eighth-row elements not yet discovered.

Pore, Jennifer L [Nuclear Science Division, Lawren

Polymer coatings on zirconia microspheres via rotating flow fluid dynamics

Conventional tristructural isotropic (TRISO) coatings for nuclear fuels require multi-step and expensive formation processes; any breakage of the coatings may lead to fission species release. Polymer derived ceramic (PDC) coatings can be a suitable alternative to address these issues. In this study, allylhydridopolycarbosilane (SMP-10) coatings were created on yttria stabilized zirconia (YSZ) microspheres using a Rotating Flow Fluid Dynamics (RFFD) coating method. The effects of curing temperature, rotation speed, and coating cycle/time on the coating were analyzed. Surface functionalization of YSZ microspheres with NaOH resulted in good adhesion between the polymer precursor and the YSZ kernel particles. Spectroscopy analysis revealed complete curing of SMP-10 coated YSZ at 160 °C. Rotation speed and coating time significantly affect the coating characteristics. After 3 cycles at lower rotation speed (50 rpm) for 10 min each, the coating obtained was uniform and homogeneous. In comparison, the coating showed almost 10 times less eccentricity at a high rotation speed of 300 rpm. Compared with the coatings prepared at 300 rpm condition, the coatings have higher sphericity and lower eccentricity at 50 rpm. Overall, this study provides a novel and effective route for fabricating and curing SMP-10 precursor coatings on YSZ microspheres.

Ravi, Nivetha [University of Alabama, Birmingham]

Elimination of detrimental grain boundary segregation in garnets

Garnet Li 7 La 3 Zr 2 O 12 electrolyte is considered a key enabler of solid-state batteries with Li metal electrodes, but the grain boundaries impair its performance. To date, the understanding of grain boundary structures and its impact on performance remains elusive. Here, we show that element segregation at Li 7 La 3 Zr 2 O 12 grain boundaries critically governs Li transport and nucleation. During conventional sintering, Al, Ta, and La segregate at grain boundaries, locally depleting Li and creating space-charge layers that lower total ionic conductivity. Simultaneously, this segregation leads to higher electronic conductivity along grain boundaries, which promotes Li nucleation at grain boundary edges with increased risk of dendrite formation. The underlying mechanism of segregation is governed by both thermodynamic driving forces and diffusion kinetics. Building on this understanding, we develop a strategy to achieve segregation-free grain boundaries through a rapid sintering protocol that utilizes the onset of solid-state softening. This approach yields transparent, polycrystalline Li 7 La 3 Zr 2 O 12 with negligible grain boundary impedance and enhanced dendrite tolerance. By elucidating the structural origins and electrochemical consequences of grain boundary segregation, this work provides a guidance for the rational optimization of solid electrolytes.

Energy - Storage

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Thermal Considerations for 2039 Opposition Class Nuclear Electric Propulsion/Chemical Propulsion Crewed Mars Mission

The high specific impulse (Isp) of Nuclear Electric Propulsion (NEP) technology offers the potential for advanced space mission capabilities. However, the five critical technology elements of NEP vehicles have yet to prove technical maturity levels for consideration into mission design. In response to the critical reviews by the NASA Engineering and Safety Center (NESC) and the National Academies of Sciences, Engineering, and Medicine (NASEM), NASA’s Space Nuclear Propulsion (SNP) project created an NEP Technology Maturation Plan (TMP) for focused development of NEP technology. The TMP called for a coordinated set of technology development efforts to meet this objective. The Modular Assembled Radiators for NEP VehicLes (MARVL) Early Career Initiative (ECI) project was initiated to develop a portion of the fifth Critical Technology Element (CTE) of the NEP vehicle: the Primary Heat Rejection Subsystem (PHRS). A target application of a 2039 human-rated Mars mission was outlined in the TMP. For the outlined mission, a NEP vehicle will experience several thermal environments which will impact the design and operation of the PHRS. To maintain radiator temperatures within the required effective temperature range, the effect of natural, induced, and NEP internally generated heat loads on the radiator panel must be well understood. Furthermore, this analysis is critical for analyzing the influence of various orientations and positions of the NEP vehicle relative to nearby celestial bodies throughout the mission. This study conducted a complete enveloping analysis of the thermal environments influencing the NEP vehicle throughout the mission. Thermal analysis was conducted for the radiator panels based on the defined mission environments. This thermal analysis concludes with the selection of ideal radiator orientations for the NEP vehicle, and the identification of worst case hot and cold environmental sink temperatures throughout the mission. For the target application, the environmental sink temperature while the reactor is powered OFF or powered ON ranges from 30 K to 353 K and 2.7 K to 243 K respectively. When considering interplanetary space, the minimum environmental sink temperature when the reactor is powered OFF and the radiators are oriented “edge to Sun” is 2.7 K. The environmental thermal models generated in this study will be used for future studies with the full vehicle system model. The environmental sink temperature curves generated will be used for future radiator and component analysis to predict transient performance in the space environment. The environmental sink temperature and heat rejection capability curves will inform the trade between commissioning orbits that are in consideration. The model may also serve as a useful tool as reference for future crewed space missions, missions involving radiators or temperature sensitive equipment, or other missions requiring analysis of natural orbital thermal environments.

Nuclear Electric Propulsion

Methanol mixing−controlled compression ignition enabled via homogeneous charge compression ignition of dimethyl ether through catalytic decomposition of methanol

Methanol is a potentially attractive fuel for marine and off−road engines owing to its availability at bunkering and global distribution locations. Although methanol is well−distributed worldwide, its fuel chemistry and ignition properties make it poorly suited as a direct drop−in replacement for diesel fuel in compression−ignition engines. However, industrial processes are regularly used to convert methanol, via catalytic dehydration, to dimethyl ether (DME) over nonprecious metal catalysts. This chemical conversion can occur at relatively low pressures, temperatures, and catalyst space velocities, highlighting a potential opportunity to generate DME via onboard catalytic dehydration of methanol. DME’s fuel kinetic and ignition properties for compression ignition are much more favorable than those of methanol or even diesel fuel, but DME is more challenging than diesel fuel or methanol to pump, store, and deliver through conventional diesel fueling injection hardware. Thus, a potential opportunity exists to use the ignition and kinetic properties of DME, with the transportation and delivery advantages of methanol, in a methanol−fueled mixing−controlled compression−ignition engine. The present work explores performance, combustion behavior, and emissions reduction opportunities for methanol mixing−controlled combustion, enabled by a HCCI of DME that represents a small fraction of the total fuel energy that can be generated onboard via catalytic dehydration of methanol.

Splitter, Derek [ORNL] (ORCID:0000000174044047)

Electrodynamic Tethers. 1: Power Generator in LEO. 2: Thrust for Propulsion and Power Storage

An electrodynamic tether consists of a long insulated wire in space whose orbital motion cuts across lines of magnetic flux to produce an induce voltage that in typical low orbits averages about 200 v/km. Such a system should be capable of generating substantial electrical power, at the expense of IXB drag acting on its orbital energy. If a reverse current is driven against the induced voltage, the system should act as a motor producing IXB thrust. A reference system was designed, capable of generating 20 KW of power into an electrical load located anywhere along the wire at the expense of 2.6N (20,000 J/sec) drag on the wire. In an ideal system, the conversion between mechanical and electrical energy would reach 100% efficiency. In the actual system part of the 20 KW is lost to internal resistance of the wire, plasma and ionosphere, while the drag force is increased by residual air drag. The 20 KW PMG system as designed is estimated to provide 18.7 KW net power to the load at total drag loss of 20.4 KJ/sec, or an overall efficiency of 92%. Similar systems using heavier wire appear capable of producing power levels in excess of 1 Megawatt at voltages of 2-4 KV, with conversion efficiency between mechanical and electrical power better than 95%. The hollow cathode based system should be readily reversible from generator to motor operation by driving a reverse current using onboard power.

James E Mccoy

Bi‐Continuous W‐Rich Refractory High Entropy Alloy‐Cu Composite: Toward Material Innovation of Nuclear Reactor Coolant System

Abstract Refractory high‐entropy alloys (RHEAs) are considered promising candidate materials for next‐generation nuclear reactors due to their superior mechanical strength, irradiation resistance, and thermal stability at high temperatures. However, the significant positive heat of mixing between refractory alloying elements and Cu, commonly used in cooling systems, poses challenges in forming composite structures. This study addresses the issue using a liquid metal dealloying (LMD) process. A precursor alloy (WTaVTi) with a directional dendrite‐interdendrite structure is fabricated and reacted with molten Cu at 1200 °C for 96 h. This approach produced a RHEA‐Cu composite with a stable interface between RHEA (W 31.5 Ta 30.9 V 21.4 Ti 14.3 ) and Cu, featuring a spontaneously formed W‐rich interlayer that enhances interfacial bonding. The composite showed excellent irradiation resistance, with 30% less swelling under α‐ion irradiation than pure W. It also exhibited low thermal conductivity at room temperature, but reached ≈120 W m −1 ·K −1 at ≈650 °C, surpassing pure W. This temperature‐dependent rise in κ, with a positive gradient of +0.075 W m −1 ·K − 2 , is attributed to decreasing diffuse mismatch at elevated temperatures. The large‐scale reaction and stable microstructure achieved through LMD process highlight its industrial potential. This work offers a strategy for developing high‐performance materials by combining RHEA's radiation resistance with Cu's thermal conductivity for extreme environments.

Chemistry

A hybrid Monte Carlo-deterministic second moment method with efficient variance reduction

In this work, we present a hybrid method that combines Monte Carlo with deterministic finite element methods to solve a linear Boltzmann transport equation. Our hybrid method runs orders of magnitude faster than Monte Carlo, without sacrificing accuracy, for a proxy problem from radiative transfer that contains both optically-thick and optically-thin material. We believe that this is the first demonstration of a hybrid Second Moment Method in more than one spatial dimension, the first to consider more than one material, and the first to use variance reduction. Our variance reduction approach arises from an asymptotic analysis in which we show that the magnitude of the scattering source grows without bound. We transform the problem to compute the deviation of the radiation intensity from isotropy. The magnitude of the source in the transformed problem is bounded, and the quality of the hybrid method solution is dramatically improved by a substantial reduction in the variance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS