Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images

Purpose: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry. Methods: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5°/voxels, keeping ≤5% difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed. Results: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (−15.50 ± 5.59)% to (−2.12 ± 1.05)% and (−7.28 ± 2.30)% to (−0.23 ± 0.71)% for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79% to 22.70% for liver and 26.00% to 39.70% for spleen with different segmentation methods. Conclusions: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.

60 APPLIED LIFE SCIENCES↗

User Directed Tools for Exploiting Expert Knowledge in an Immersive Segmentation and Visualization Environment

Volumetric data sets have become common in medicine and many sciences through technologies such as computed x-ray tomography (CT), magnetic resonance (MR), positron emission tomography (PET), confocal microscopy and 3D ultrasound. When presented with 2D images humans immediately and unconsciously begin a visual analysis of the scene. The viewer surveys the scene identifying significant landmarks and building an internal mental model of presented information. The identification of features is strongly influenced by the viewers expectations based upon their expert knowledge of what the image should contain. While not a conscious activity, the viewer makes a series of choices about how to interpret the scene. These choices occur in parallel with viewing the scene and effectively change the way the viewer sees the image. It is this interaction of viewing and choice which is the basis of many familiar visual illusions. This is especially important in the interpretation of medical images where it is the expert knowledge of the radiologist which interprets the image. For 3D data sets this interaction of view and choice is frustrated because choices must precede the visualization of the data set. It is not possible to visualize the data set with out making some initial choices which determine how the volume of data is presented to the eye. These choices include, view point orientation, region identification, color and opacity assignments. Further compounding the problem is the fact that these visualization choices are defined in terms of computer graphics as opposed to language of the experts knowledge. The long term goal of this project is to develop an environment where the user can interact with volumetric data sets using tools which promote the utilization of expert knowledge by incorporating visualization and choice into a tight computational loop. The tools will support activities involving the segmentation of structures, construction of surface meshes and local filtering of the data set. To conform to this environment tools should have several key attributes. First, they should be only rely on computations over a local neighborhood of the probe position. Second, they should operate iteratively over time converging towards a limit behavior. Third, they should adapt to user input modifying they operational parameters with time.

Senger, Steven O.↗

Deep Point Cloud Building Envelope Segmentation (DeeP-CuBES) using Deep Learning

Building Information Modeling (BIM) plays an important role in building design and construction, particularly for achieving energy-efficient retrofits. Building envelope retrofits using panelized prefabricated system, such as those popularized by the Energiesprong program, need accurate as-built dimensions of facade features (windows, doors, etc.) to achieve the desired thermal and air tightness. Traditionally, building surveying is done manually, resulting in a time-consuming and labor-intensive process. Recently, 3D point clouds from terrestrial LiDAR have been used to automate the generation of as-built dimensions of existing buildings. However, automated BIM using LiDAR relies on solving the point cloud semantic segmentation (PCSS) problem. In this work, we propose a robust pipeline for solving the PCSS problem using deep neural networks, focusing on overcoming challenges posed by imbalanced datasets and complex architectural features. We introduce the first high-density, labeled, and validated building envelope point cloud dataset derived from multiple building scans, specifically curated to tackle challenges in facade-level segmentation. Results from the trained neural networks show that advanced attention-based architectures and incorporating radiometry (light intensity and RGB) features significantly boost segmentation accuracy for windows and doors.

Selvakumar, Balaji [ORNL]↗

Local-global alignment for finding 3D similarities in protein structures

A method of finding 3D similarities in protein structures of a first molecule and a second molecule. The method comprises providing preselected information regarding the first molecule and the second molecule. Comparing the first molecule and the second molecule using Longest Continuous Segments (LCS) analysis. Comparing the first molecule and the second molecule using Global Distance Test (GDT) analysis. Comparing the first molecule and the second molecule using Local Global Alignment Scoring function (LGA_S) analysis. Verifying constructed alignment and repeating the steps to find the regions of 3D similarities in protein structures.

59 BASIC BIOLOGICAL SCIENCES↗

Three dimensional (3D) microstructure-based finite element modeling of Al-SiC nanolaminates using focused ion beam (FIB) tomography

Al-SiC nanolaminate composites show promise as high performance coating materials due to their combination of strength and toughness. Although a significant amount of modeling effort has been focused on materials with an idealized flat nanostructure, experimentally these materials exhibit complex undulating layer geometries. This work utilizes FIB tomography to characterize this nanostructure in 3D and finite element modeling to determine the effect that this complex structure has on the mechanical behavior of these materials. A sufficiently large volume was characterized such that a 1 × 2 μm micropillar could be generated from the dataset and compared directly to experimental results. The mechanical response from this nanostructure was then compared to pillar models using simplified structures with perfectly flat layers, layers with sinusoidal waviness, and layers with arc segment waviness. The arc segment based layer geometry showed the best agreement with the experimentally determined structure, indicating it would be the most appropriate geometry for future modeling efforts. - Highlights: •FIB tomography was used to determine the structure of an Al-SiC nanolaminate in 3D. •FEM was used to compare the deformation of the nanostructure to experimental results. •Idealized structures from literature were compared to the FIB determined structure. •Arc segment based structures approximated the FIB determined structure most closely.

36 MATERIALS SCIENCE↗

Antiferromagnetism in a Family of S = 1 Square Lattice Coordination Polymers NiX 2 (pyz) 2 (X = Cl, Br, I, NCS; pyz = Pyrazine)

The crystal structures of NiX2(pyz)(2) (X = Cl (1), Br (2), I (3), and NCS (4)) were determined by synchrotron X-ray powder diffraction. All four compounds consist of two-dimensional (2D) square arrays self-assembled from octahedral NiN4X2 units that are bridged by pyz ligands. The 2D layered motifs displayed by 1-4 are relevant to bifluoride-bridged [Ni(HF2) (pyz)(2)]EF6 (E = P, Sb), which also possess the same 2D layers. In contrast, terminal X ligands occupy axial positions in 1-4 and cause a staggered packing of adjacent layers. Long-range antiferromagnetic (AFM) order occurs below 1.5 (Cl), 1.9 (Br and NCS), and 2.5 K (I) as determined by heat capacity and muon-spin relaxation. The single-ion anisotropy and g factor of 2, 3, and 4 were measured by electron-spin resonance with no evidence for zero field splitting (ZFS) being observed. The magnetism of 1-4 spans the spectrum from quasi-two-dimensional (2D) to three-dimensional (3D) antiferromagnetism. Nearly identical results and thermodynamic features were obtained for 2 and 4 as shown by pulsed-field magnetization, magnetic susceptibility, as well as their Neel temperatures. Magnetization curves for 2 and 4 calculated by quantum Monte Carlo simulation also show excellent agreement with the pulsed-field data. Compound 3 is characterized as a 3D AFM with the interlayer interaction (j(perpendicular to)) being slightly stronger than the intralayer interaction along Ni-pyz-Ni segments (j(pyz)) within the two-dimensional [Ni(pyz)(2)](2+) square planes. Regardless of X, j(pyz), is similar for the four compounds and is roughly 1 K.

Liu, Junjie↗

Simultaneous neutron and X-ray tomography for visualization of graphite electrode degradation in fast-charged lithium-ion batteries

Advanced battery characterization using neutron and X-ray-based imaging modalities is crucial to reveal fundamental degradation modes of lithium-ion batteries (LIBs). Taking advantage of the sensitivity of neutrons to some low-Z (Li) and X-rays to high-Z materials (Cu), here we demonstrate the viability of simultaneous neutron and X-ray tomography (NeXT) as a non-destructive imaging platform for ex-situ 3D visualization of graphite electrode degradation following extreme fast charging (XFC). In addition, we underscore the benefits of the simultaneous of NeXT by combining the neutron and X-ray tomography data from the same sample location for material identification and segmentation of one pristine and two XFC-cycled graphite electrodes (9C charge for 450 cycles). Our ex-situ results and methodology development pave the way for the design of NeXT-friendly LIB geometries that will allow operando and/or in-situ 3D visualization of electrode degradation during XFC.

25 ENERGY STORAGE↗

WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.

60 APPLIED LIFE SCIENCES↗

Progress Update on Iterative Reconstruction of Neutron Tomographic Images

This report satisfies the fiscal year 2016 technical deliverable to report on progress in development of fast iterative reconstruction algorithms for project OR16-3DTomography-PD2Jb, "3D Tomography and Image Processing Using Fast Neutrons." This project has two overall goals. The first of these goals is to extend associated-particle fast neutron transmission and, particularly, induced-reaction tomographic imaging algorithms to three dimensions. The second of these goals is to automatically segment the resultant tomographic images into constituent parts, and then extract information about the parts, such as the class of shape and potentially shape parameters. This report addresses of the component of the project concerned with three-dimensional (3D) image reconstruction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Geometrically projected discrete dislocation dynamics

Three-dimensional discrete dislocation dynamics methods (3D-DDD) have been developed to explicitly track the motion of individual dislocations under applied stress. At present, these methods are limited to plastic strains of about one percent or less due to high computational cost associated with the interactions between large numbers of dislocations. This limitation motivates the construction of minimalistic approaches to efficiently simulate the motion of dislocations for higher strains and longer time scales. In the present study, we propose geometrically projected discrete dislocation dynamics (GP-DDD), a method in which dislocation loops are modeled as geometrical objects that maintain their shape with a constant number of degrees of freedom as they expand. We present an example where rectangles composed of two screw and two edge dislocation segments are used for modeling gliding dislocation loops. We use this model to simulate single slip loading of copper and compare the results with detailed 3D-DDD simulations. We discuss the regimes in which GP-DDD is able to adequately capture the variation of the flow stress with strain rate in the single slip loading condition. In conclusion, a simulation using GP-DDD requires ~40 times fewer degrees of freedom for a copper single slip loading case, thus reducing computational time and complexity.

36 MATERIALS SCIENCE↗

Three-dimensional paganica fault morphology obtained from hypocenter clustering (L'Aquila 2009 seismic sequence, Central Italy)

In seismic modelling, fault planes are normally assumed to be flat due to the lack of data which can constrain fault morphology. However, incorporating 3D fault morphology is important for modelling several phenomena, for example calculating mainshock induced stress changes. Here we utilize a data-analytical method to unveil the 3D rupture morphology of faults using unsupervised clustering techniques applied to earthquake hypocenters in seismic sequences. We apply this method to the 2009 L'Aquila seismic sequence which involved a M W 6.1 mainshock on April 6th. We use a dataset of about 50,000 relocated events, mostly microearthquakes, reaching magnitude of completeness equal to 0.7. Clustering distinguishes the earthquakes as occurring in three main clusters along with other minor fault segments. We then represent the morphology of the main Paganica fault system (responsible for the largest mainshock) using splines. This method shows promise as a step toward robustly and quickly obtaining 3D rupture morphologies where earthquake sequences have been monitored. The 3D model is presented interactively online, and the processing is presented in an interactive Jupyter Notebook (https://bit.ly/2MnCFdj).

58 GEOSCIENCES↗

Progress Update on Iterative Reconstruction of Neutron Tomographic Images, 2019

The fiscal year (FY) 2019 update of this report satisfies the technical deliverable “Simultaneous reconstruction of simultaneous observables” for project OR16-ML-3DTomography-PD3Jb, “3D Tomography and Image Processing Using Fast Neutrons.” At its inception, this project had two overall goals. The first of these goals was to extend associated-particle fast neutron transmission and, particularly, induced-reaction tomographic imaging algorithms to three dimensions. The second of these goals was to automatically segment the resultant tomographic images into constituent parts and then extract information about the parts, such as the class of shape and potentially shape parameters. This report addresses the component of the project concerned with three-dimensional (3D) image reconstruction and represents the cumulative progress to date. In particular, it addresses the ability to decompose neutrons arriving at times consistent with transmission into transmission and small-angle scattering. Because incremental progress in each year builds on the previous year’s progress and end-ofyear status, progress is most usefully recorded in a cumulative document where incremental progress is reported on a year-by-year basis. Consequently, this report constitutes an update of the last 3 years’ reports [1, 2, 14]. The present year’s progress is detailed in Section 7.

47 OTHER INSTRUMENTATION↗

Multimodal Nanoscale Tomographic Imaging for Battery Electrodes

Accurate representations of the 3D structure within a lithium-ion battery are key to understanding performance limitations. However, obtaining exact reconstructions of electrodes, where the active particles, the carbon black and polymeric binder domain, and the pore space are visualized is challenging. In this work, it is shown that multimodal imaging can be used to overcome this challenge. High-resolution ptychographic X-ray computed tomography are combined with lower resolution but higher contrast transmission X-ray tomographic microscopy to obtain 3D reconstructions of pristine and cycled graphite-silicon composite electrodes. This cross-correlation enables quantitative analysis of the surface of active particles, including the heterogeneity of carbon-black and binder domain and solid-electrolyte interphase coverage. Capturing the active particles as well as the carbon black-binder domain allows using these segmented structures for electrochemical simulations to highlight the influence of the particle embedding on local state of charge heterogeneities.

25 ENERGY STORAGE↗

VANO: a volume-object image annotation system

Volume-object annotation system (VANO) is a cross-platform image annotation system that enables one to conveniently visualize and annotate 3D volume objects including nuclei and cells. An application of VANO typically starts with an initial collection of objects produced by a segmentation computation. The objects can then be labeled, categorized, deleted, added, split, merged and redefined. VANO has been used to build high-resolution digital atlases of the nuclei of Caenorhabditis elegans at the L1 stage and the nuclei of Drosophila melanogaster’s ventral nerve cord at the late embryonic stage.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling the Impact of Space Suit Components and Anthropometry on the Center of Mass of a Seated Crewmember

The Crew Impact Attenuation System (CIAS) is the energy-absorbing strut concept that dampens Orion Crew Exploration Vehicle (CEV) landing loads to levels sustainable by the crew. Significant COM variations across suited crew configurations would amplify the inertial effects of the pallet and potentially create unacceptable crew loading during launch and landing. The objective of this study was to obtain data needed for dynamic simulation models by quantifying the effects of posture, suit components, and the expected range of anthropometry on the COM of a seated individual. Several elements are required for the COM calculation of a suited human in a seated position: anthropometry, body segment mass, suit component mass, suit component location relative to the body, and joint angles defining the seated posture. Three-dimensional (3D) human body models, suit mass data, and vector calculus were utilized to compute the COM positions for 12 boundary manikins in two different seated postures. The analysis focused on two objectives: (1) quantify how much the wholebody COM varied from the smallest to largest subject and (2) quantify the effects of the suit components on the overall COM in each seat configuration. The location of the anterior-posterior COM varied across all boundary manikins by about 7 cm, and the vertical COM varied by approximately 9 to 10 cm. The mediolateral COM varied by 1.2 cm from the midline sagittal plane for both seat configurations. The suit components caused an anterior shift of the total COM by approximately 2 cm and a shift to the right along the mediolateral axis of 0.4 cm for both seat configurations. When the seat configuration was in the standard posture the suited vertical COM shifted inferiorly by as much as 1 cm, whereas in the CEV posture the vertical COM had no appreciable change. These general differences were due to the high proportion of suit mass located in the boots and lower legs and their corresponding distance from the body COM, as well as to the prevalence of suit components on the right side of the body.

Blackledge, Christopher↗

An Anisotropic Fluid-Solid Model of the Mouse Heart

A critical challenge in biomechanical simulations is the spatial discretization of complex fluid-solid geometries created from imaging. This is especially important when dealing with Lagrangian interfaces, as there must be at a minimum both geometric and topological compatibility between fluid and solid phases, with exact matching of the interfacial nodes being highly desirable. We have developed a solution to this problem and applied the approach to the creation of a 3D fluidsolid mesh of the mouse heart. First, a 50 micron isotropic MRI dataset of a perfusion-fixed mouse heart was segmented into blood, tissue, and background using a customized multimaterial connected fuzzy thresholding algorithm. Then, a multimaterial marching cubes algorithm was applied to produce two compatible isosurfaces, one for the blood-tissue boundary and one for the tissue-background boundary. A multimaterial smoothing algorithm that rigorously conserves volume for each phase simultaneously smoothed the isosurfaces. Next we applied novel automated meshing algorithms to generate anisotropic hybrid meshes with the number of layers and the desired element anisotropy for each material as the only input parameters. As the meshes are scale-invariant within a material and include boundary layer prisms, fluid-structure interaction computations would have a relative error equilibrated over the entire mesh. The resulting model is highly detailed mesh representation of the mouse heart, including features such as chordae and coronary vasculature, that is also maximally efficient to produce the best simulation results for the computational resources available

59 BASIC BIOLOGICAL SCIENCES↗

Augmented DNA Nanoarchitectures: A Structural Library of 3D Self-Assembling Tensegrity Triangle Variants

The DNA tensegrity triangle is known to reliably self-assemble into a 3D rhombohedral crystalline lattice via sticky-end cohesion. Here, in this study, the library of accessible motifs is expanded through covalent extensions of intertriangle regions and sticky-end-coordinated linkages of adjacent triangles with double helical segments using both geometrically symmetric and asymmetric configurations. The molecular structures of 18 self-assembled architectures at resolutions of 3.32–9.32 Å are reported; the observed cell dimensions, cavity sizes, and cross-sectional areas agree with theoretical expectations. These data demonstrate that fine control over triclinic and rhombohedral crystal parameters and the customizability of more complex 3D DNA lattices are attainable via rational design. It is anticipated that augmented DNA architectures may be fine-tuned for the self-assembly of designer nanocages, guest–host complexes, and proscriptive 3D nanomaterials, as originally envisioned. Finally, designer asymmetric crystalline building blocks can be seen as a first step toward controlling and encoding information in three dimensions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗