Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - AIRFOILS - OSCILLATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

MODELING OF ENHANCED AIR DEHUMIDIFICATION THROUGH ELECTRICALLY CHARGED VAPOR CAPTURING ELECTROSTATIC DROPLETS

This paper investigated the potential of a new electrostatic-based water vapor separation system for humidity control in buildings. The Electrospray Vortical Flow eXchanger (EVFX) consists of small electrically charged water droplets released inside air vortexes to attract water vapor molecules, effectively wiping out the humidity from the air. Larger droplets are then removed at the outer wall of the vortex. If a water molecule is placed in a gradient electric field, such a polar molecule experiences a dielectrophoresis force, which moves the molecules and produces a vapor concentration gradient. When the vapor density exceeds the saturation level, nucleation occurs. A thermodynamic model that captures this phenomenon was described in this paper. Electrosprayed droplets were initially charged close to their maximum electrical charge dictated by the Rayleigh limit; these droplets were used as nucleation centers. The high electric charge decreased the pressure of the vapor, which was in equilibrium with the droplets. This enhanced the charged droplets' nucleation and growth that depleted the vapor phase near the droplets, which was compensated for by the dielectrophoresis flow and diffusion. Significant water vapor condensation was predicted for small droplets at a high electrical charge. Beyond a specific droplet size, while the condensation of water vapor was still theoretically possible, it was somewhat limited because the further growth of the large charged droplets was inhibited due to their high inherent water vapor pressure near the surface. A case study illustrated the potentials and limitation of the EVFX for droplets charged to the Rayleigh limit, for which the effective range of diameters resulted between 10 nm up to few micron.

Morcelli, Stefano↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Modeling Efforts to Gain Insight into Historical Leak Events from the Single-Shell Tank A-105 in the Hanford 241-A Tank Farm - 20113

The 241-A Tank Farm is a single-shell tank (SST) farm constructed to store process waste from Hanford nuclear operations. Millions of gallons of nuclear waste were stored in the 241-A Tank Farm SSTs and some of the SSTs leaked in the past. In addition, spills and pipeline leaks during transfers and storage and intentional discharges to cribs and trenches resulted in releasing waste to the ground. Tank liner leaks are referred to as 'leaks' and all other discharges to the soil are referred to as 'releases.' Liquid waste that could be removed by pumping has been removed from all of the SSTs to reduce the potential for future leaks. The most significant historical leak event in 241-A Tank Farm occurred in 1965 when tank A-105 experienced a pressurized steam event. This event resulted in damage to the inner steel liner flooring of A-105, which was separated from the sidewalls over part of its circumference and buckled up to 2.5 m, vertically. During this event up to 7,570 L of contaminated liquid may have leaked to the adjacent soil. This leak occurred under extreme temperature and pressure conditions. Modeling efforts to better understand the nature and extent of historical leaks from subsurface SSTs that were used to store highly radioactive, self-boiling liquid wastes at 241-A Tank Farm have recently been undertaken. These efforts have compiled the available historical information to support a preliminary non-isothermal, multiphase flow and chemical transport modeling effort to re-create the conditions under which the leaks occurred and to formulate a conceptual model as to the extent and distribution of leaked radioactive contaminants in the adjacent soil material. The focus of this work was on developing an understanding of the key features, processes and bounding conditions related to tank A-105 leak events that occurred in the 1960's. The activities include estimation of leak composition, non-isothermal multiphase flow and transport modeling, and geochemical modeling. The STOMP{sup C} Water-Air-Energy modeling code was utilized to implement the three-dimensional representation of the subsurface tank and the surrounding flow field. Once constructed, the model was used to evaluate the conceptual understanding of leaks originating from different parts of the tank under the elevated temperature boundary conditions that were imposed by surrounding tanks at the time of the historical leaks. The chemical evolution of the liquid waste was also evaluated as it leaked from the tank under transient pressure and temperature gradients. The results of the preliminary evaluation suggested the presence of a heat-pipe effect beneath tank A-105 in which water vapor at an elevated temperature is driven away from the base of the tank to a position where water vapor cools, condenses and is then drawn back toward the tank by the strong capillary attraction of the dry soil. A non-sorbing contaminant (Tc-99) was introduced into this flow field to better understand the potential distribution patterns of leaked contaminants that may have occurred during the historical leak events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical simulation of an atmospheric pressure plasma jet with coaxial shielding gas

A two-dimensional ( r, z ) numerical simulation of the discharge characteristics of an atmospheric pressure plasma jet (APPJ), with coaxial shielding gas, was performed. The helium working gas flowed in a central capillary tube, engulfing a needle electrode powered by 13.7 MHz radio frequency sinusoidal voltage. The N 2 shielding gas flowed in the annular space of a coaxial tube. These gases emerged, in laminar flow, in a 78%N 2 -21%O 2 -1%Ar dry air ambient. The characteristics of the APPJ with shielding gas were compared to those of the APPJ without shielding gas. The nitrogen shielding gas hindered the diffusion of oxygen and argon from the ambient air into the helium jet. With the shielding gas present, more nitrogen penetrated into the helium core, causing a shorter plasma ‘plume’. The flow rates of the working and shielding gas, critically affected the gas temperature, and in turn the discharge characteristics. For a He flow of 2 standard liters per minute (slm), switching on the nitrogen shielding gas flow (at 4.5 slm) reduced the on-axis O 2 and Ar mole fractions from 3.9 × 10 - 4 to 6.8 × 10 - 5 and from 1.9 × 10 - 5 to 3.3 × 10 - 6 , respectively, at an axial distance of 3 mm downstream of the nozzle. The radial profiles of the mole fractions of the ambient gases were monotonically and strongly decreasing towards the system axis, for short axial distances from the nozzle (~1 mm), but became progressively flatter at longer distances from the nozzle (3 mm and 5 mm). Simulation predictions captured the salient features of experimental data of ambient species mole fractions in the plasma jet, and the 706 nm optical emission intensity profiles of the He 3 3 S excited state.

Physics↗

The influence of surface heat fluxes on the growth of idealized monsoon depressions

This study explores the effect of surface sensible and latent heat fluxes on monsoon depressions using a series of idealized convection-permitting simulations. Each experiment is initialized with a small-amplitude wave that is allowed to grow within an environment representative of the South Asian monsoon. Comparing experiments with and without interactive surface heat fluxes, it is found that these fluxes enhance the growth of the simulated vortices. Without interactive surface fluxes, the strengthening period is short and the vortices fail to reach intensities characteristic of stronger monsoon depressions. Using a large set of experiments in which the vertical and meridional shear are systematically varied, it is found that surface heat fluxes enhance intensity the most when the upper-level shear is weak, the lower-level shear and associated moist static energy (MSE) gradient are sufficiently steep, and the lower-level meridional shear is strong. Here, these experiments reveal two different regimes of convection-coupled monsoon depression growth: one in which convection is driven by MSE advection and one in which it is driven by surface heat fluxes and quasigeostrophic forcing for ascent. Both regimes require sufficiently strong meridional shear to achieve initial growth by barotropic instability.

54 ENVIRONMENTAL SCIENCES↗

Fluid Flow Observations of The Spray Near-Field Using High-Speed X-Ray Imaging

Sprays are important to may industrial processes, but the near-field region where spray formation takes place is difficult to visualize and characterize through visible light imaging because this region is typically optically dense. X-ray imaging is one technique that can penetrate this optically dense region and provide unique observations of the spray formation process. This study uses high-speed white beam X-ray imaging conducted at the Advanced Photon Source to capture spray formation dynamics from a canonical airblast atomizer. In this work, a range of momentum flux ratios are visualized by varying the gas flow rate while the liquid flow rate is held constant. The use of X-rays show overlapping flow structures including bags, ligaments, mushrooms, and webs. Air bubbles are captured within the liquid regions, and a very dynamic crown forms at the liquid needle exit at higher momentum flux ratios. Finally, at the highest momentum flux ratios, air bubbles and liquid droplets are observed migrating upstream in the center of the crown, and this motion is attributed to a toroidal recirculation cell at the nozzle exit.

47 OTHER INSTRUMENTATION↗

Data From Experiments on Bubbling Fluidization of Zeolite in a Rectangular Bubbling Fluidized Bed

Fluidization experiments were conducted in a lab-scale rectangular bubbling fluidized bed with the objective of generating a high-quality dataset for model validation and artificial intelligence/machine learning (AI/ML) training. Zeolite was chosen as the bed material, and the fluidizing medium was air as supplied by a compressor. Three different flow rates at the inlet were chosen such that the particles were fluidized but not elutriated from the system. The test matrix involved randomization and replicates to provide uncertainty estimates as well as four different batches of zeolite as the bed material. The quantities of interest obtained from this study were statistics of differential pressures, interface heights, and particle velocities. Considering all the components of the elaborate test plan, the results obtained were consistent and reproducible. Characterization tests were performed to estimate particle properties including size, density, coefficient of friction, coefficient of restitution, and minimum fluidization velocity. In addition, the angle of repose from granular discharge experiments has been reported to account for rolling friction, though its effect on the overall process is expected to be negligible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A&L Annual Report: GRM-MAPS

Exploding Bridge Wire (EBW) is an important design for initiating detonators relevant to several LLNL systems. In such designs, a metal bridge wire is in direct contact with a porous secondary high explosive (HE), typically pressed to around 50% of its crystalline density. Initiation is believed to occur through shock waves generated when the bridge wire is made to explode via the rapid passing of a strong current pulse. Permeametry is an important characterization tool for the porous powdered HE (PETN, HMX, etc.) component in such devices. Such powders are well known to coarsen with age, with an accompanying deterioration in performance, which includes increased function time and sensitivity. Among various material characteristics, one that has been shown to correlate the most with such performance parameters is the flow-permeable surface area (FSSA), measured using air-permeametry. Commercially available permeametry apparatuses, such as that from Fisher Scientific or a more modern version from Micromeritics suffer from a few drawbacks, most notably as related to monitoring age-related changes in FSSA. This is because it requires re-compaction of the aged powder into the permeametry tube, which in most cases leads to an unwanted increase in FSSA. To address this and a few other shortcomings, we have been developing a modern version of the permeameter, Gee-Reinstein-Maiti Modern Air-Permeametry System (GRM-MAPS). In this report, we summarize progress made in FY25 toward perfecting and calibrating the instrument, which we aim at deploying within surveillance in FY26.

36 MATERIALS SCIENCE↗

MAIA: A new detector concept for a 10 TeV muon collider

Muon colliders offer a compelling opportunity to explore the TeV scale and conduct precision tests of the Standard Model, all within a relatively compact geographical footprint. This paper introduces a new detector concept, MAIA (Muon Accelerator Instrumented Apparatus), optimized for $\sqrt{s}=10$ TeV $\mu\mu$ collisions. The detector features an all-silicon tracker immersed in a 5T solenoid field. High-granularity silicon-tungsten and iron-scintillator calorimeters surrounding the solenoid capture high-energy electronic and hadronic showers, respectively, and support particle-flow reconstruction. The outermost subsystem comprises an air-gap muon spectrometer, which enables standalone track reconstruction for high-momentum muons. The performance of the MAIA detector is evaluated in terms of differential particle reconstruction efficiencies and resolutions. Beam-induced background (BIB) simulations generated in FLUKA are overlaid with single particle gun samples to assess detector reconstruction capabilities under realistic experimental conditions. Even with BIB, reconstruction efficiencies exceed 95% for energetic tracks, photons, and neutrons in the central region of the detector. This paper outlines promising avenues of future work, including forward region optimization and opportunities for enhanced flavor/boosted object tagging, and addresses the technological assumptions needed to achieve the desired detector performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open millifluidics based on powder-encased channels

Millifluidics, the manipulation of liquid flow in millimeter-sized channels, has been a revolutionary concept in chemical processing and engineering. The solid channels that contain the liquids, though, are not flexible in their design and modification, and prevent contact with the external environment. All-liquid constructs, on the other hand, while flexible and open, are imbedded in a liquid environment. Here, we provide a route to circumvent these limitations by encasing the liquids in a hydrophobic powder in air that jams on the surface, containing and isolating flowing fluids, offering flexibility and adaptability in design, as manifest in the ability to reconfigure, graft, and segment the constructs. Along with the open nature of these powder-contained channels that allow arbitrary connections/disconnections and substance addition/extraction, numerous applications can be opened in the biological, chemical, and material arenas.

36 MATERIALS SCIENCE↗

Theoretical Approach for the Fast Estimation of the Turbulent Kinematic Viscosity for Internal Flows

An analytical expression for turbulent kinematic viscosity (νt), based solely on the hydraulic Reynolds number (Re), was derived and evaluated. The analytical expression is valid for the fast estimation of νt for internal, isotropic, fully developed flows. The expression was compared with experimental and simulation data for air, water, and liquid sodium, and was shown to provide reasonable values for 2100 ≤ Re ≤ 3.6 × 106 and Prandtl number (Pr) range of 0.0107 ≤ Pr ≤ 5.65. In addition, new expressions suitable for the central portion of internal flows, away from the wall, were derived for the turbulent Reynolds number (ReT), showing its relationship to Re, as well as to the ratio of νt and the molecular kinematic viscosity (ν).

42 ENGINEERING↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow With 25% Upsizing Allowance for Heating

This documentation focuses on a single end-use savings shape upgrade - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation and where 25% upsizing (or 125% of the original size) is allowed for heating in colder climates (i.e., heating dominant regions). This document will primarily discuss the additional changes to the sizing algorithm and modeling approach, while a comprehensive overview of the fundamental modeling methodology and background of the VRF HR DOAS upgrade, including applicability and other key assumptions can be found in the original documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System. To provide more context on the 25% upsizing algorithm, if the building is a cooling dominant (e.g., design cooling load higher than design heating load ), then the outdoor unit capacity of the VRF heat pump is sized based on the design cooling load. However, if the building is heating dominant, then this building is a candidate for the 25% upsizing allowance. Once the 25% upsizing is allowed, if the 25% upsized capacity (or 125% from the original size) represented with design condition exceeds the design heating load, then the design heating load is used for calculating the rated capacity of the outdoor unit. And if the 25% upsized capacity represented with the design condition does not exceed the design heating load, then the 25% upsized capacity represented with rated condition is used for the capacity of the outdoor unit while the remaining heating load is handled with the supplemental/backup electric resistance coil.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

3D Time-Lapse Electrical Resistivity Imaging of Rock Damage Patterns and Gas Flow Paths Resulting from Two Underground Chemical Explosions

Abstract Rock damage from underground nuclear explosions (UNEs) has a strong influence on sub-surface gas movement and on seismic waveform characteristics, both of which are used to detect UNEs. Although advanced numerical simulation capabilities exist to predict rock damage patterns and corresponding detection signals, those predictions are dependent on (generally) unknown properties of the host rock. For example, the effects of in-situ mechanical heterogeneities on the explosively generated damage/fractures that provide gas flow pathways to the surface are not well understood, due largely to the difficulty in accessing and characterizing the near-source region. In this paper we demonstrate the emerging use of electrical resistivity tomography (ERT) for imaging rock damage and gas flow patterns resulting from two relatively small-scale underground chemical explosions. Pre-explosion ERT and crosshole seismic imaging revealed a natural fracture zone within the test bed. Post-explosion imaging revealed that the damage zone was non-symmetric and was focused primarily within the pre-existing fracture zone, located 10 m above the first explosion and 5 m above the second explosion. Time-lapse ERT imaging of heated air injected into the detonation borehole revealed the primary gas flow paths to be within the upper margin of the same primary damage zone. These results point to the utility of ERT imaging for understanding rock damage and gas flow patterns under experimental conditions, and to the importance of understanding the effects of geologic heterogeneity on UNE detection signals, particularly gas surface breakthrough times.

58 GEOSCIENCES↗

Modeling and mitigating airborne pathogen risk factors in school buses

Computational fluid dynamics (CFD) models were developed to simulate the impact of different ventilation scenarios on airborne exposure risks in a 72-passenger school bus. Here, scenarios and factors that were investigated included a moving vs. stationary bus, impacts of a heating unit within the bus, and impacts of alternative ventilation scenarios with different combinations of openings (e.g., windows, door, emergency hatch). Results of the simulations showed that when the bus was stationary, use of the heater increased receptor concentrations unless there was another opening. When the bus was moving, simulations with at least two sets of openings separated from each other in the forward and aft directions produced a through-flow condition that reduced concentrations via dilution from outside air by a factor of ten or more. A single opening in a moving bus generally increased concentrations throughout the cabin due to increased mixing with minimal ventilation. The cumulative exposure risk (time-averaged concentrations) was found to be inversely correlated to the air exchange rate. Stationary and moving-bus scenarios that yielded above ~20 air changes per hour resulted in the lowest cumulative exposures. Recommendations from this study were implemented in new safety and operating procedures by the Albuquerque Public Schools Transportation Center.

60 APPLIED LIFE SCIENCES↗

A Novel Multiagent Resource Sharing Algorithm for Control of Advanced Energy Systems

This paper implements a novel resource sharing control strategy on a fuel cell–gas turbine hybrid power system at the National Energy Technology Laboratory’s Hybrid Performance Facility (Hyper). In a fuel cell–gas turbine hybrid power system, the simultaneous interaction of the gas turbine and the fuel cell creates a tightly coupled environment characterized by conflicting dynamics. In this paper, a model-free control approach is applied to solve the tightly coupled control problem posed by this challenging environment. Specifically, this control problem is presented as a resource sharing problem that can be solved using a resource sharing algorithm that is defined based on the distribution construction concept. This algorithm creates computational agents and solves the problem through the distribution and redistribution of shared resources defined as blocks. Furthermore, two agents were created; the first agent (agent 1) controls the gas turbine speed by adjusting the electric load, and the second agent (agent 2) controls the cathode mass flow through the fuel cell using the cold-air bypass valve. A parametric study was performed over the course of 15 experimental tests for both agents 1 and 2 through an evaluation of the responses based on setpoint changes. The algorithm was shown to have behavior comparable to a previously implemented multi-input multioutput state-space controller, which was designed through a model-based control approach. The resource sharing algorithm was able to find stable performance during run-time operations without any prior system knowledge identification on the power plant and without creating models used in traditional control strategies.

25 ENERGY STORAGE↗