Search NASA⌕ Search

SEARCH · Search NASA

Results for “Active cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Solar photochemical process engineering for production of fuels and chemicals

The engineering costs and performance of a nominal 25,000 scmd (883,000 scfd) photochemical plant to produce dihydrogen from water were studied. Two systems were considered, one based on flat-plate collector/reactors and the other on linear parabolic troughs. Engineering subsystems were specified including the collector/reactor, support hardware, field transport piping, gas compression equipment, and balance-of-plant (BOP) items. Overall plant efficiencies of 10.3 and 11.6 percent are estimated for the flat-plate and trough systems, respectively, based on assumed solar photochemical efficiencies of 12.9 and 14.6 percent. Because of the opposing effects of concentration ratio and operating temperature on efficiency, it was concluded that reactor cooling would be necessary with the trough system. Both active and passive cooling methods were considered. Capital costs and energy costs, for both concentrating and non-concentrating systems, were determined and their sensitivity to efficiency and economic parameters were analyzed. The overall plant efficiency is the single most important factor in determining the cost of the fuel.

Biddle, J. R.↗

A model for lava flows with two thermal components

This paper presents a mathematical model for the cooling of an active flow with two separate thermal components, one of which is a crust that cools by radiation and thickens with time and the other an inner core that is vertically isothermal and partially exposed at the top surface, where heat is lost by radiation. This model provides a more realistic description of active lava flows than the existing models that assume thermal homogeneity in each vertical cross section perpendicular to the direction of flow advance. The results of the model were found to compare favorably with existing field data. The effects of different crustal thickening rates, fractional areas of crust, and eruption temperatures on the cooling of the two thermal components were examined.

Crisp, Joy↗

Enhancement of Cognitive Processing by Multiple Sclerosis Patients Using Liquid Cooling Technology: A Case Study

Cognitive dysfunction is a common symptom in patients with multiple sclerosis (MS). This can have a significant impact on the quality of life of both the patient and of their primary care giver. This case study explores the possibility that liquid cooling therapy may be used to enhance the cognitive processing of MS patients in the same way that it provides temporary relief of some physical impairment. Two MS patients were presented a series of pattern discrimination tasks before and after being cooled with a liquid cooling garment for a one hour period. The subject whose ear temperature was reduced during cooling showed greater electroencephalographic (EEG) activity and scored much better on the task after cooling. The patient whose ear temperature was unaffected by cooling showed less EEG activity and degraded performance after the one hour cooling period.

Montgomery, Leslie D.↗

Supersonic Laminar Flow Control Research

The objective of this research is to understand supersonic laminar flow stability, transition and active control. Some prediction techniques are developed or modified to analyze laminar flow stability. The effects of distributed heating and cooling as an active boundary layer control technique are studied. The primary tasks of the research apply to the NASA/Ames Proof-of-Concept (PoC) and the Laminar Flow Supersonic Wind Tunnel's (LFSWT's) nozzle design with laminar flow control and are listed as follows: (1) Predictions of supersonic laminar boundary layer stability and transition; (2) Effects of wall heating and cooling on supersonic laminar flow control on a flat plate; (3) Performance evaluation of the PoC and LFSWT nozzle designs with wall heating and cooling applied at different locations and various lengths; (4) Effects of a conducted -vs- pulse wall temperature distribution for the LFSWT; and (5) Application of wall heating and/or cooling to laminar boundary layer and flow separation control of airfoils and investigation of related active control techniques.

Lo, C. F.↗

Supersonic Laminar Flow Control Research

The objective of this research is to understand supersonic laminar flow stability, transition and active control. Some prediction techniques will be developed or modified to analyze laminar flow stability. The effects of distributed heating and cooling as an active boundary layer control technique will be studied. The primary tasks of the research apply to the NASA/Ames PoC and LFSWT's nozzle design with laminar flow control and are listed as follows: Predictions of supersonic laminar boundary layer stability and transition; Effects of wall heating and cooling on supersonic laminar flow control on a flat plate; Performance evaluation of the PoC and LFSWT nozzle designs with wall heating and cooling applied at different locations and various lengths; Effects of a conducted-vs-pulse wall temperature distribution for the LFSWT; and Application of wall heating and/or cooling to laminar boundary layer and flow separation control of airfoils and investigation of related active control techniques.

Lo, Ching F.↗

Thermoregulation and heat exchange in a nonuniform thermal environment during simulated extended EVA. Extravehicular activities

BACKGROUND: Nonuniform heating and cooling of the body, a possibility during extended duration extravehicular activities (EVA), was studied by means of a specially designed water circulating garment that independently heated or cooled the right and left sides of the body. The purpose was to assess whether there was a generalized reaction on the finger in extreme contradictory temperatures on the body surface, as a potential heat status controller. METHOD: Eight subjects, six men and two women, were studied while wearing a sagittally divided experimental garment with hands exposed in the following conditions: Stage 1 baseline--total body garment inlet water temperature at 33 degrees C; Stage 2--left side inlet water temperature heated to 45 degrees C; right side cooled to 8 degrees C; Stage 3--left side inlet water temperature cooled to 8 degrees C, right side heated to 45 degrees C. RESULTS: Temperatures on each side of the body surface as well as ear canal temperature (Tec) showed statistically significant Stage x Side interactions, demonstrating responsiveness to the thermal manipulations. Right and left finger temperatures (Tfing) were not significantly different across stages; their dynamic across time was similar. Rectal temperature (Tre) was not reactive to prevailing cold on the body surface, and therefore not informative. Subjective perception of heat and cold on the left and right sides of the body was consistent with actual temperature manipulations. CONCLUSIONS: Tec and Tre estimates of internal temperature do not provide accurate data for evaluating overall thermal status in nonuniform thermal conditions on the body surface. The use of Tfing has significant potential in providing more accurate information on thermal status and as a feedback method for more precise thermal regulation of the astronaut within the EVA space suit.

Non-NASA Center↗

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Human Thermal Modeling↗

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Spacesuit↗

Fire and Ice - Safety, Comfort, and Getting the Firefighters' Job Done

Daily life for firefighters consists of working with life-threatening hazards in hostile environments. A major hazard is excessive ambient heat. New hazards have arisen from protective gear that was intended to increase survival time of firefighters while finding and rescuing victims. The insulation is so good now that a firefighter's metabolic heat buildup cannot escape. This forces body core temperatures to life threatening levels in about 20 minutes of moderate activity. Using NASA space suit technology, Oceaneering Space Systems developed a liquid cooling garment prototype that will remove up to 250 watts of metabolic heat. After testing and certification as an approved accessory for firefighter use, this garment will be available for use by any individual encapsulated in protective clothing. This demonstration will present a high surface area circulated liquid cooling garment displayed on a mannequin and available for attendees to try on to experience the effects of active cooling.

Foley, Tico↗

Supersonic laminar flow control research

The objective of this research is to understand supersonic laminar flow stability, transition and active control. Some prediction techniques will be developed or modified to analyze laminar flow stability. The effects of distributed heating and cooling as an active boundary layer control technique will be studied. The primary tasks of the research apply to the NASA/Ames PoC and LFSWT's nozzle design with laminar flow control and are listed as follows: (1) predictions of supersonic laminar boundary layer stability and transition; (2) effects of wall heating and cooling on supersonic laminar flow control; (3) performance evaluation of the PoC and LFSWT nozzle designs with wall heating and cooling applied at different locations and various lengths; and (4) effects of a conducted -vs- pulse wall temperature distribution for the LFSWT.

Lo, Ching F.↗

Supersonic laminar flow control research

The objective is to understand supersonic laminar flow stability, transition, and active control. Some prediction techniques will be developed or modified to analyze laminar flow stability. The effects of distributed heating and cooling as an active boundary layer control technique will be studied. The primary tasks of the research apply to the NASA/Ames Proof of Concept (PoC) and Laminar Flow Supersonic Wind Tunnel's (LFSWT's) nozzle design with laminar flow control and are listed as follows: (1) predictions of supersonic laminar boundary layer stability and transition, (2) effects of wall heating and cooling on supersonic laminar flow control, (3) performance evaluation of the PoC and LFSWT nozzle designs with wall heating and cooling applied at different locations and various lengths, and (4) effects of a conducted versus pulse wall temperature distribution for the LFSWT.

Lo, Ching F.↗

Shuttle active thermal control system development testing. Volume 5: Integrated radiator/expendable cooling system tests

Tests were conducted to gather data on a space shuttle active control system (ATCS) incorporating both radiators and an expendable cooling device to provide vehicle heat removal. Two systems were tested and design information was provided for both nominal and limit conditions. The tests verified the concept that an integrated radiator/expendable cooling system can adequately maintain desired water quantities while responding to variations in heat loads and environments. In addition, the need for duct heating was demonstrated, while exhaust nozzle heating was also shown to be unnecessary.

Scheps, P. B.↗

Atacama Compact Array Measurements of the Molecular Mass in the NGC 5044 Cooling-Flow Group

The fate of cooling gas in the centers of galaxy clusters and groups is still not well understood, as is also the case for the complex processes of triggering star formation in central dominant galaxies, reheating of cooled gas by active galactic nuclei (AGN), and the triggering or “feeding” of supermassive black hole outbursts. We present CO observations of the early-type galaxy NGC 5044, which resides at the center of an X-ray bright group with a moderate cooling flow. For our analysis we combine CO(2−1) data from the 7 m antennae of the Atacama Compact Array (ACA) and the ACA total power array (TP). We demonstrate, using the 7 m array data, that we can recover the total flux inferred from IRAM 30 m single-dish observations, which corresponds to a total molecular mass of about 4 × 10(exp 7) M⨀ Most of the recovered flux is blueshifted with respect to the galaxy rest frame and is extended on kiloparsec-scales, suggesting low filling factor dispersed clouds. We find eight concentrations of molecular gas out to a radius of 10” (1.5 kpc), which we identify with giant molecular clouds. The total molecular gas mass is more centrally concentrated than the X-ray emitting gas but is extended in the northeast-southwest direction beyond the IRAM 30 m beam. We also compare the spatial extent of the molecular gas to the Hα emission: The CO emission coincides with the very bright Hα region in the center. We do not detect CO emission in the fainter Hα regions. Furthermore, we find two CO absorption features spatially located at the center of the galaxy, within 5 pc projected distance of the AGN, infalling at 255 and 265 km s(exp −1) relative to the AGN. This indicates that the two giant molecular clouds seen in absorption are most likely within the sphere of influence of the supermassive black hole.

Galaxy clusters↗

A direct-interface fusible heat sink for astronaut cooling

Astronaut cooling during extravehicular activity is a critical design issue in developing a portable life support system that meets the requirements of a space station mission. Some the requirements are that the cooling device can be easily regenerable and nonventing during operation. In response to this, a direct-interface, fusible heat sink prototpye with freezable quick-disconnects was developed. A proof-of-concept prototype was constructed and tested that consists of an elastic container filled with normal tap water and having two quick-disconnects embedded in a wall. These quick-disconnects are designed so that they may be frozen with the ice and yet still be joined to the cooling system, allowing an immediate flow path. The inherent difficulties in a direct-interface heat sink have been overcome, i.e., (1) establishing an initial flow path; (2) avoiding low-flow freeze-up; and (3) achieving adequate heat-transfer rates at the end of the melting process. The requirements, design, fabrication, and testing are discussed.

Lomax, Curtis↗

A direct-interface, fusible heat sink for astronaut cooling

Astronaut cooling during extravehicular activity is a critical design issue in developing a portable life support system that meets the requirements of a space station mission. Some of the requirements are that the cooling device can be easily regenerable and nonventing during operation. In response to this, a direct-interface, fusible heat sink prototype with freezable quick-disconnects was developed. A proof-of-concept prototype was constructed and tested that consists of an elastic container filled with normal tap water and having two quick-disconnects embedded in a wall. These quick-disconnects are designed so that they may be frozen with the ice and yet still be joined to the cooling system, allowing an immediate flow path. The inherent difficulties in a direct-interface heat sink have been overcome, i.e., (1) establishing an initial flow path; (2) avoiding low-flow freeze-up; and (3) achieving adequate heat-transfer rates at the end of the melting process. The requirements, design, fabrication, and testing are discussed.

Lomax, Curtis↗

Physiological and Thermal Responses of MS Patients to Head and Vest Cooling: A Case Study

Personal cooling systems are used to alleviate symptoms of multiple sclerosis (MS) and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term application of the stationary thermal control system used by most clinical institutions. The Life Enhancement Tech (LET) Mark VII portable cooling system and a lightweight Head-vest active cooling garment were used to cool the head and chest regions of 4 male and 3 female MS patients (30 to 66 yrs. old) in this study. The subjects, seated in an upright position at normal room temperature (approx. 24 C), were tested for 60 min. with the liquid cooling garment (LCG) operated at 50 F. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures, heart rate, respiration, and an activity index were recorded continuously on a U.F.I., Inc., Biolog ambulatory monitor. All temperature responses showed extreme variation among subjects. The cold-sensitive subject's rectal temperature increased initially in response to cooling; the heat sensitive subject's rectal temperature decreased. After 40 min. of cooling and during recovery, all subjects'rectal temperatures decreased. Oral temperatures began to decrease after 30 min. of cooling. After 60 min. of cooling, temperature drops ranged from approx. 0.3 - 0.8 C. Oral temperatures continued to decrease during recovery (approx. 0.2 C). The car temperature of the heat sensitive subject was increased after cooling, other subjects exhibited an ear temperature decrease (0.0 - 0.5 C). These data indicate that head and vest cooling may be used to reduce the oral temperatures of MS patients by the approximate amount needed for symptomatic relief as shown by other researchers. The combination of a small subject population and a large subject variance does not permit us to draw statistical conclusions about the temperature response of MS patients. An individual's heat or cold sensitivity may influence their thermal response to cooling. This factor should be considered in the prescribed use of liquid cooling garments in the therapeutic management of MS.

Luna, Bernadette↗