Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Pupil Alignment Considerations for Large, Deployable Space Telescopes

For many optical systems the properties and alignment of the internal apertures and pupils are not critical or controlled with high precision during optical system design, fabrication or assembly. In wide angle imaging systems, for instance, the entrance pupil position and orientation is typically unconstrained and varies over the system s field of view in order to optimize image quality. Aperture tolerances usually do not receive the same amount of scrutiny as optical surface aberrations or throughput characteristics because performance degradation is typically graceful with misalignment, generally only causing a slight reduction in system sensitivity due to vignetting. But for a large deployable space-based observatory like the James Webb Space Telescope (JWST), we have found that pupil alignment is a key parameter. For in addition to vignetting, JWST pupil errors cause uncertainty in the wavefront sensing process that is used to construct the observatory on-orbit. Furthermore they also open stray light paths that degrade the science return from some of the telescope s instrument channels. In response to these consequences, we have developed several pupil measurement techniques for the cryogenic vacuum test where JWST science instrument pupil alignment is verified. These approaches use pupil alignment references within the JWST science instruments; pupil imaging lenses in three science instrument channels; and unique pupil characterization features in the optical test equipment. This will allow us to verify and crosscheck the lateral pupil alignment of the JWST science instruments to approximately 1-2% of their pupil diameters.

Bos, Brent J.↗

Alignment and Integration of Lightweight Mirror Segments

The optics for the International X-Ray Observatory (IXO) require alignment and integration of about fourteen thousand thin mirror segments to achieve the mission goal of 3.0 square meters of effective area at 1.25 keV with an angular resolution of five arc-seconds. These mirror segments are 0.4 mm thick, and 200 to 400 mm in size, which makes it difficult not to impart distortion at the sub-arc-second level. This paper outlines the precise alignment, permanent bonding, and verification testing techniques developed at NASA's Goddard Space Flight Center (GSFC). Improvements in alignment include new hardware and automation software. Improvements in bonding include two module new simulators to bond mirrors into, a glass housing for proving single pair bonding, and a Kovar module for bonding multiple pairs of mirrors. Three separate bonding trials were x-ray tested producing results meeting the requirement of sub ten arc-second alignment. This paper will highlight these recent advances in alignment, testing, and bonding techniques and the exciting developments in thin x-ray optic technology development.

Evans, Tyler↗

Alignment and Scaling of Large-Scale Fluctuations in Solar Wind Turbulence

We investigate the dependence of solar wind fluctuations measured by the Wind spacecraft on scale and on the degree of alignment between oppositely directed Elsasser fields. This alignment controls the strength of the non-linear interactions and, therefore, the turbulence. We find that at scales larger than the outer scale of the turbulence the Elsasser fluctuations become on average more anti-aligned as the outer scale is approached from above. Conditioning their structure functions using the alignment angle reveals turbulent scaling of unaligned fluctuations at scales previously believed to lie outside the turbulent cascade in the '1/f range'. We argue that the 1/f range contains a mixture of non-interacting anti-aligned population of Alfven waves and magnetic force-free structures plus a subdominant population of unaligned cascading turbulent fluctuations.

Wicks, R. T.↗

Motorized Beam Alignment of a Commercial X-ray Diffractometer

X-ray diffraction (XRD) is a powerful analysis method that allows researchers to noninvasively probe the crystalline structure of a material. This includes the ability to determine the crystalline phases present, quantify surface residual stresses, and measure the distribution of crystallographic orientations. The Structures and Materials Division at the NASA Glenn Research Center (GRC) heavily uses the on-site XRD lab to characterize advanced metal alloys, ceramics, and polymers. One of the x-ray diffractometers in the XRD lab (Bruker D8 Discover) uses three different x-ray tubes (Cu, Cr, and Mn) for optimal performance over numerous material types and various experimental techniques. This requires that the tubes be switched out and aligned between experiments. This alignment maximizes the x-ray tube s output through an iterative process involving four set screws. However, the output of the x-ray tube cannot be monitored during the adjustment process due to standard radiation safety engineering controls that prevent exposure to the x-ray beam when the diffractometer doors are open. Therefore, the adjustment process is a very tedious series of blind adjustments, each followed by measurement of the output beam using a PIN diode after the enclosure doors are shut. This process can take up to 4 hr to perform. This technical memorandum documents an in-house project to motorize this alignment process. Unlike a human, motors are not harmed by x-ray radiation of the energy range used in this instrument. Therefore, using motors to adjust the set screws will allow the researcher to monitor the x-ray tube s output while making interactive adjustments from outside the diffractometer. The motorized alignment system consists of four motors, a motor controller, and a hand-held user interface module. Our goal was to reduce the alignment time to less than 30 min. The time available was the 10-week span of the Lewis' Educational and Research Collaborative Internship Project (LERCIP) summer internship program and the budget goal was $1200. In this report, we will describe our motorization design and discuss the results of its implementation.

Van Zandt, Noah R.↗

On the Alignment and Focusing of the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket instrument that is designed to observe soft X-ray emissions from 24 - 6.0 A (0.5 - 2.0 keV energies) in the solar atmosphere. For the rst time, high-temperature, low-emission plasma will be observed directly with 5 arcsecond spatial resolution and 22 mA spectral resolution. The unique optical design consists of a Wolter - I telescope and a 3-optic grazing- incidence spectrometer. The spectrometer utilizes a nite conjugate mirror pair and a blazed planar, varied line spaced grating, which is directly printed on a silicon substrate using e-beam lithography. The grating design is being nalized and the grating will be fabricated by the Massachusetts Institute of Technology (MIT) and Izentis LLC. Marshall Space Flight Center (MSFC) is producing the nickel replicated telescope and spectrometer mirrors using the same facilities and techniques as those developed for the ART-XC and FOXSI mirrors. The Smithsonian Astrophysical Observatory (SAO) will mount and align the optical sub-assemblies based on previous experience with similar instruments, such as the Hinode X-Ray Telescope (XRT). The telescope and spectrometer assembly will be aligned in visible light through the implementation of a theodolite and reference mirrors, in addition to the centroid detector assembly (CDA) { a device designed to align the AXAF-I nested mirrors. Focusing of the telescope and spectrometer will be achieved using the X-ray source in the Stray Light Facility (SLF) at MSFC. We present results from an alignment sensitivity analysis performed on the on the system and we also discuss the method for aligning and focusing MaGIXS.

solar↗

Spacecraft Alignment Determination and Control for Dual Spacecraft Precision Formation Flying

Many proposed formation flying missions seek to advance the state of the art in spacecraft science imaging by utilizing dual-spacecraft precision formation flying (PFF) to enable a 'virtual' telescope (VT). Using precision dual-spacecraft alignment, very long focal lengths can be achieved by locating the optics on one spacecraft and the detector on the other. Proposed science missions include astrophysics concepts for X-ray imaging and exo-planet observation with large spacecraft separations (1000 km to 80,000 km), and heliophysics concepts for X-ray or extreme ultra-violet (EUV) imaging or solar coronagraphs with smaller separations (50m - 500m). These proposed missions require advances in guidance, navigation, and control (GN&C) for PFF to enable high resolution science imaging. For many applications, the dual-spacecraft dynamics are coupled through the GN&C system when the relative ranging and position alignment sensor components are not co-located with their respective spacecraft mass centers. We develop a model-based PFF system design approach for the VT application, considering the coupling inherent in precision dual-spacecraft inertial alignment. These systems employ a variety of GN&C sensors and actuators, including laser-based alignment and ranging systems, camera-based imaging sensors, inertial measurement units (IMU), as well as microthruster systems and image motion compensation platforms. Results of a GN&C performance assessment reveal how data from relative position sensors can be employed in a Kalman filter framework to significantly improve alignment estimation performance. The assessment provides a comparison of two different GN&C formation flying architectures, illustrating the performance trades inherent in the choice of PFF system architecture in the VT application.

Formation Flying↗

On-Ground Calibration and Optical Alignment for the Orion Optical Navigation Camera

The Orion Multi-Purpose Crew Vehicle on-board Navigation System will utilize the Optical Navigation measurements of the Moon and Earth during cis-lunar operations. Misalignment or an un-calibrated optical navigation camera may cause large measurement residuals in any on-board attitude determination and navigation system. Therefore, a novel estimation technique to calibrate the internal camera parameters, and a high accuracy optical alignment procedure to estimate the external camera alignment are introduced in this paper. The intrinsic camera parameters such as the focal length, the principle point offsets, and the camera lens distortion parameters will be estimated and evaluated using images of star fields. This calibration estimation technique can be used either on-ground or in flight. The proposed technique in this paper is using the discrepancy between imaged star vectors attained from the OpNav camera, and the matched star vectors from the star catalog to determine the changes in internal camera parameters. This gave rise to the two basic types of calibration the attitude dependent and attitude independent methods. The former utilizes the errors in imaged and cataloged vectors themselves, and the latter using the discrepancy in angles between pairs of vectors from the camera and catalog. The alignment procedure is carried out using Theodolite autocollimator measurements taken off alignment cubes mounted on the Orion frame and also the measurements from the OpNav focal plane. It is assumed that the alignment cubes and OpNav camera are rigidly mounted to the frame so that flexing effects do not significantly alter the orientation of the cubes relative to the OpNav camera.

Samaan, Malak↗

An Efficient Focal Plane Alignment Methodology with Application to the ASTERIA Nanosatellite Space Telescope

The process of aligning an instrument focal plane toprecursor optics such as a telescope can be a difficult and timeconsuming process. The final alignment must achieve sufficientperformance at multiple locations across the field of view. Inthe case of instruments with infinite conjugates, such as a spacetelescope, there are practical challenges in illuminating the system at multiple off-axis field points simultaneously. Iterationduring the alignment process can cause a lengthy search for localminima within the performance cost function.This paper presents a focal plane alignment methodology thatavoids the above difficulties and obtains the desired level ofoptical performance in an efficient manner. The approach isbased on systematically measuring spot size across a set of fieldpoints and defocus positions, and then using a least squaresfit to determine the optimal location for the focal plane. Thisapproach has the additional benefit of revealing the amount offield curvature present in the instrument. It also provides theanalyst with a direct calculation of the shims needed to place thefocal plane at the computed best-fit location.This approach was successfully applied to the Arcsecond SpaceTelescope Enabling Research In Astrophysics (ASTERIA) payload. ASTERIA is a cubesat mission that was deployed intolow-Earth orbit in November 2017 and operated until December2019. In addition to presenting the theoretical basis for themethodology, this paper will present laboratory measurementsobtained during the payload alignment campaign. This approach is applicable to future space-borne optical instrumentsthat require an efficient methodology for focal plane alignmentwith limited cost or schedule resources.

Smith, Matthew W↗

High Precision Track-Based Alignment of the Tracking Detector of the g-2 Experiment

In order for the analysis of data from the tracking detector to reduce the systematic uncertainty on the a_μ measurement and improve the sensitivity to a muon electric dipole moment, the internal position of the tracking modules must be known to a high level of precision. Track-based alignment was implemented with data from Run 1 using the Millepede II framework. An overview of the alignment methods, as well as the verification of alignment with simulation, will be given. A significant improvement in the mean p-value distribution and the fraction of reconstructed tracks after the alignment was achieved. A comparison of the accuracy in the determination of the beam's spatial distribution as a function of time will be presented before and after the alignment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Method of aligning a laser-based radiation source

A method for temporally and spatially aligning a laser-based x-ray source and maintaining alignment is disclosed. A pump laser beam, which interacts with a plasma source to create an electron beam, is aligned with the electron beam. A scattering laser beam is overlapped with the pump laser beam at an intersection point. The pump laser beam and scattering laser beam alignments are monitored and adjusted to maintain optimal alignment during operation of the laser-based x-ray source.

Umstadter, Donald↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are thus a key element of many beamlines at X-ray facilities, used to either to focus a beam or image a sample. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam; aligning CRLs is thus typically treated as a time-consuming manual process. Many groups circumvent day-to-day realignment by using engineering controls (e.g. mounting optics) that sacrifice some of the beam’s focusing characteristics, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. Our approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder-Mead (SNM) simplex method. We demonstrate the efficacy of this method by numerical simulation and then extend this test to real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron X-ray beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

97 MATHEMATICS AND COMPUTING↗

An Online Dynamic Amplitude-Correcting Gradient Estimation Technique to Align X-ray Focusing Optics

High-brightness X-ray pulses, as generated at synchrotrons and X-ray free electron lasers (XFELs), are used in a variety of scientific experiments. At these facilities, measurements often require optical equipment, e.g Compound Refractive Lenses (CRLs) to be precisely aligned and focused. The lateral alignment of CRLs to a beamline requires precise positioning along four axes: two translational, and the two rotational. At a synchrotron, alignment is often accomplished manually. However, XFEL beamlines present a beam brightness that fluctuates stochastically, making manual alignment a time-consuming endeavor. Automation using simplex or classic stochastic descent often fails, given the errant gradient estimates. Herein we present a dynamic-amplitude correction to the usual gradient based on the combination of a generalized finite difference stencil and a time-dependent sampling pattern. Intensity is recorded periodically, then used to normalize numerical derivatives against fluctuations. Error expectation is analyzed, and efficacy is demonstrated on classic benchmarks. We provide a proof of concept by laterally aligning optics on a simulated XFEL beamline using data recorded at both synchrotron and XFEL facilities.

97 MATHEMATICS AND COMPUTING↗

Embedded 3D printing of isotropically enhanced lattice structure with programmable elasticity via three-dimensional fiber alignment

Engineered composites with fiber orientation in a complete three-dimensional (3D) context are highly desired for maximizing structural performance as they mimic the well-organized fiber arrangement in natural composites. However, most fabrication techniques lack the capability for through-plane (z-axis) alignment, limiting the possibility for structural design and performance optimization. In this study, we present an embedded 3D printing approach that enables complete 3D fiber alignment, including region-specific alignment control along the through-plane direction. Our method utilizes the extrusion and suspension of composite inks within a supporting matrix. By regionally adjusting the ink extrusion rate and nozzle translation rate, we locally manipulated the fiber arrangement within the composite 3D architecture. Here, we demonstrate that the 3D alignment of carbon fibers in a structural composite significantly enhances both mechanical properties and thermal conductivity in the in-plane and through-plane directions. Furthermore, by strategically arranging regional fiber orientations within micro-architected materials, we fabricated metamaterial engineered composites with programmable anisotropy ratio and directional moduli.

36 MATERIALS SCIENCE↗

Soft-Shear-Aligned Vertically Oriented Lamellar Block Copolymers for Template-Free Sub-10 nm Patterning and Hybrid Nanostructures

The template-free unidirectional alignment of lamellar block copolymers (l-BCPs) for sub-10 nm high-resolution patterning and hybrid multicomponent nanostructures is important for technological applications. Here we demonstrate a modified soft-shear directed self-assembly (SDSA) approach for aligning pristine l-BCPs and l-BCPs with incorporated polymer grafted nanoparticles (PGNPs), as well as the l-BCPs conversion to aligned gold nanowires, and hybrid of metallic gold nanowire and dielectric silica nanoparticle in the form of line-dot nanostructures. The smallest patterns have a half-pitch as small as 9.8 nm. In all cases, soft-shear is achieved using a high molecular mass polymer topcoat layer, with support on a neutral bottom layer. We also show that the hybrid line-dot nanostructures have a red-shifted plasmonic response in comparison to the neat gold nanowires. These template-free aligned BCPs and nanowires have potential use in nanopatterning applications and the line-dot nanostructures should be useful in the plasmonic sensing of biomolecules and other molecular species based on the plasmonic response of the nanowires.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Origin of Strain-Induced Chain Alignment in PDPP-Based Semiconducting Polymeric Thin Films

Donor–acceptor (D–A) type semiconducting polymers have shown great potential for the application of deformable and stretchable electronics in recent decades. However, due to their heterogeneous structure with rigid backbones and long solubilizing side chains, the fundamental understanding of their molecular picture upon mechanical deformation still lacks investigation. Here, the molecular orientation of diketopyrrolopyrrole (DPP)-based D–A polymer thin films is probed under tensile deformation via both experimental measurements and molecular modeling. The detailed morphological analysis demonstrates highly aligned polymer crystallites upon deformation, while the degree of backbone alignment is limited within the crystalline domain. Besides, the aromatic ring on polymer backbones rotates parallel to the strain direction despite the relatively low overall chain anisotropy. Additionally, the effect of side-chain length on the DPP chain alignment is observed to be less noticeable. These observations are distinct from traditional linear-chain semicrystalline polymers like polyethylene due to distinct characteristics of backbone/side-chain combination and the crystallographic characteristics in DPP polymers. Furthermore, a stable and isotropic charge carrier mobility is obtained from fabricated organic field-effect transistors. This study deconvolutes the alignment of different components within the thin-film microstructure and highlights that crystallite rotation and chain slippage are the primary deformation mechanisms for semiconducting polymers.

36 MATERIALS SCIENCE↗

Exceptional Alignment in a Donor–Acceptor Conjugated Polymer via a Previously Unobserved Liquid Crystal Mesophase

Abstract Orienting polymer semiconductors is desirable to optimize device characteristics, provide insight into microstructure, and magnify subtle phase behavior. Here, a combination of uniaxial strain and subsequent heating of the donor–acceptor (DA) polymer PBnDT‐FTAZ is discovered to lead to exceptional optical dichroic ratios of up to 38 (and close to 50 near the polymer's absorption edge). This alignment is achieved due to the existence of a previously undetected thermotropic liquid crystal (LC) mesophase. The LC transition, not discernable through calorimetry, is uncovered through a combination of in situ UV–vis spectroscopy, X‐ray scattering, and dynamic mechanical analysis (DMA). Comparing PBnDT‐FTAZ to the non‐fluorinated PBnDT‐HTAZ and the homo polymer PBnDT, all of which show similar thermal transitions, reveals that exceptional alignment is only found in PBnDT‐FTAZ. This is attributed to the PBnDT‐FTAZ film having two distinct liquid crystal populations, and the polymer templating to a highly aligned, high‐clearing temperature population when heated. The DMA thermal relaxation behavior observed here is also seen in other DA conjugated polymers suggesting that such thermotropic LC mesophases may be common in these materials. These findings demonstrate a polymer semiconductor with remarkable alignment and uncover phase behavior with broad implications for process‐structure‐property relationships in polymer semiconductors.

36 MATERIALS SCIENCE↗

Alignment frustration in block copolymer films with block copolymer grafted TiO 2 nanoparticles under soft-shear cold zone annealing

Block copolymers (BCPs) have received significant attention as promising candidates for sequestering nanoparticles and fabrication of aligned nanostructures with optimal optical or electrical properties. We investigate the influence of static and dynamic thermal field on the alignment of polystyrene-block-poly(methyl methacrylate) (PS-b-PMMA) BCP morphology with the loading of novel poly(methyl methacrylate-block-Polystyrene) (PMMA-b-PS)-grafted-TiO 2 nanoparticles (BCP-g-TiO 2 ). Observation of characteristics IR peaks for PMMA and PS in BCP-g-TiO 2 nanoparticles and Transmission Electron Microscopy (TEM) results of the outer coating of core nanoparticle, validate the grafting to approach in synthesizing BCP-g-TiO 2 . In this work, we report that under the sharp dynamic thermal field, at low loading of BCP-g-TiO 2 , there is good dispersion of nanoparticles in unidirectionally aligned BCP matrix in film interior probed by GISAXS, while, at high nanoparticle loading (~10 wt%), there is local frustration in the unidirectional alignment of the BCP matrix due to aggregation of BCP-g-TiO 2 nanoparticles. However, Grazing incidence small angle X-ray scattering (GISAXS) shows clearly that the BCP films remain largely locally ordered at the domain scale, despite these large perturbations to long-range ordering even at high loading level, while bringing in new TiO 2 functionality to the BCP films, such as UVO absorptivity or biofouling prevention, important to potential new applications of such membranes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Phantom and Clinical Study of Differences in Cone Beam Computed Tomographic Registration When Aligned to Maximum and Average Intensity Projection

Purpose: To determine whether maximum or average intensity projection (MIP or AIP, respectively) reconstructed from 4-dimensional computed tomography (4DCT) is preferred for alignment to cone beam CT (CBCT) images in lung stereotactic body radiation therapy. Methods and Materials: Stationary CT and 4DCT images were acquired with a target phantom at the center of motion and moving along the superior–inferior (SI) direction, respectively. Motion profiles were asymmetrical waveforms with amplitudes of 10, 15, and 20 mm and a 4-second cycle. Stationary CBCT and dynamic CBCT images were acquired in the same manner as stationary CT and 4DCT images. Stationary CBCT was aligned to stationary CT, and the couch position was used as the baseline. Dynamic CBCT was aligned to the MIP and AIP of corresponding amplitudes. Registration error was defined as the SI deviation of the couch position from the baseline. In 16 patients with isolated lung lesions, free-breathing CBCT (FBCBCT) was registered to AIP and MIP (64 sessions in total), and the difference in couch shifts was calculated. Results: In the phantom study, registration errors were within 0.1 mm for AIP and 1.5 to 1.8 mm toward the inferior direction for MIP. In the patient study, the difference in the couch shifts (mean, range) was insignificant in the right-left (0.0 mm, ≤1.0 mm) and anterior–posterior (0.0 mm, ≤2.1 mm) directions. In the SI direction, however, the couch position significantly shifted in the inferior direction after MIP registration compared with after AIP registration (mean, −0.6 mm; ranging 1.7 mm to the superior side and 3.5 mm to the inferior side, P=.02). Conclusions: AIP is recommended as the reference image for registration to FBCBCT when target alignment is performed in the presence of asymmetrical respiratory motion, whereas MIP causes systematic target positioning error.

62 RADIOLOGY AND NUCLEAR MEDICINE↗