Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analog Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Parametric test of a zirconium (4) oxide-polyacrylic acid dual layer hyperfiltration membrane with spacecraft washwater

Performance data consisting of solute rejections and product flux were measured, as dependent on the operation parameters. These parameters and ranges were pressure (500,000 n/m2 to 700,000 n/m2), temperature (74 C to 95 C), velocity (1.6 M/sec to 10 M/sec), and concentration (up to 14x). Tests were carried out on analog washwater. Data presented include rejections of organic materials, ammonia, urea, and an assortment of ions. The membrane used was deposited in situ on a porcelain ceramic substrate.

Brandon, C. A.↗

Parametric evaluation of a dual-layer dynamic hyperfiltration membrane for recovery of spacecraft wash water at elevated temperature

Performance data consisting of solute rejections and product flux have been measured, as dependent on the operational parameters. These parameters were pressure, 5,000,000 N/sq m (750 psia) to 7,000,000 N/sq m (1040 psia); temperature, 347 K (165 F) to 368 K (200 F); velocity, 1.6 m/s to 10 m/s; and concentration (up to 14x). Tests were carried out on analog wash water. Data taken include rejections of organic materials (TOC), ammonia, urea, and an assortment of ions. The membrane used was a dual-layer, polyacrylic acid over zirconium oxide, deposited in situ on a porcelain ceramic substrate.

Brandon, C. A.↗

Earth-based studies

Theoretical understanding of geologic processes of all planets and satellites is the ultimate goal of comparative geologic studies, simply because it is not possible to sample and study all bodies in the solar system in situ. Theories must make verifiable predictions, be able to test the aptness of terrestrial analogs, and ultimately should provide direction for future planetary research.

Dwornik, S.↗

Periodic control of the individual-blade-control helicopter rotor

Results of an investigation into methods of controller design for an individual helicopter rotor blade in the high forward-flight speed regime are described. This operating condition poses a unique control problem in that the perturbation equations of motion are linear with coefficients that vary periodically with time. The design of a control law was based on extensions to modern multivariate synthesis techniques and incorporated a novel approach to the reconstruction of the missing system state variables. The controller was tested on both an electronic analog computer simulation of the out-of-plane flapping dynamics, and on a four foot diameter single-bladed model helicopter rotor in the M.I.T. 5x7 subsonic wind tunnel at high levels of advance ratio. It is shown that modal control using the IBC concept is possible over a large range of advance ratios with only a modest amount of computational power required.

Mckillip, R. M., Jr.↗

A microprocessor based anti-aliasing filter for a PCM system

Described is the design and evaluation of a microprocessor based digital filter. The filter was made to investigate the feasibility of a digital replacement for the analog pre-sampling filters used in telemetry systems at the NASA Ames-Dryden Flight Research Facility (DFRF). The digital filter will utilize an Intel 2920 Analog Signal Processor (ASP) chip. Testing includes measurements of: (1) the filter frequency response and, (2) the filter signal resolution. The evaluation of the digital filter was made on the basis of circuit size, projected environmental stability and filter resolution. The 2920 based digital filter was found to meet or exceed the pre-sampling filter specifications for limited signal resolution applications.

Morrow, D. C.↗

Implementation of a noise reduction circuit for spaceflight IR spectrometers

The paper discusses the implementation and analysis of a correlated triple sampling circuit using analog subtractor/integrators. The software and test setup for noise measurements are also described. The correlation circuitry is part of the signal chain for a 256-element InSb line array used in the Visible and Infrared Mapping Spectrometer. Using a focal-plane array (FPA) simulator, system noise measurements of 0.7 DN are obtained. A test setup for FPA/SPE (signal processing electronics) characterization along with noise measurements is demonstrated.

Ramirez, L.↗

Design of Combustor for Long-range Ram-jet Engine and Performance of Rectangular Analog

The report describes the design of a piloted combustor intended for a ram-jet engine of long flight range. The unit comprises a large annular basket of V-type cross-section, the inner surface of which is slotted and bent into small V-gutters. At the trailing edge of the basket, eight V-gutters are used to propagate the flame into the main stream. A rectangular analog of this combustor was tested at air-flow conditions corresponding to those that might be obtained during cruise. At these conditions, combustion efficiencies of as much as 90 percent were calculated for the combustor at the design equivalence ratio of 0.52. The performance of the unit was relatively insensitive to mounting and flow variables; the greatest effect on efficiency was that of the manner and location of the fuel injection. A full-scale version of this combustor has been designed for a 48-inch-diameter engine.

ENGINES, RAM-JET - COMBUSTION CHAMBERS↗

Feed-forward control of gear mesh vibration using piezoelectric actuators

This paper presents a novel means for suppressing gear mesh-related vibrations. The key components in this approach are piezoelectric actuators and a high-frequency, analog feed-forward controller. Test results are presented and show up to a 70-percent reduction in gear mesh acceleration and vibration control up to 4500 Hz. The principle of the approach is explained by an analysis of a harmonically excited, general linear vibratory system.

Montague, Gerald T.↗

Adaptive-Grid Methods for Phase Field Models of Microstructure Development

Modeling solidification microstructures has become an area of intense study in recent years. The properties of large scale cast products, ranging from automobile engine blocks to aircraft components and other industrial applications, are strongly dependent on the physics that occur at the mesoscopic and microscopic length scales during solidification. The predominant morphology found in solidification microstructures is the dendrite, a tree-like pattern of solid around which solidification proceeds. The microscopic properties of cast products are determined by the length scales of these dendrites, and their associated segregation profiles. For this reason understanding the mechanisms for pattern selection in dendritic growth has attracted a great deal of interest from the experimental and theoretical communities. In particular, a great deal of research has been undertaken to understand such issues as dendrite morphology, shape and growth speed. Experiments on dendrite evolution in pure materials by Glicksman and coworkers on succinonitrile (SCN), and more recently pivalic acid (PVA), as well as other transparent analogs of metals, have provided tests of theories for dendritic growth, and have stimulated considerable theoretical progress. These experiments have clearly demonstrated that in certain parameter ranges the physics of the dendrite tip can be characterized by a steady value for the dendrite tip velocity, radius of curvature and shape. Away from the tip, the time-dependent dendrite exhibits a characteristic sidebranching as it propagates, which is not yet well understood. These experiments are performed by observing individual dendrites growing into an undercooled melt. The experiments are characterized by the dimensionless undercooling. Most experiments are performed at low undercooling.

Dantzig, Jonathan A.↗

Analog Techniques for Measuring the Frequency Response of Linear Physical Systems Excited by Frequency-Sweep Inputs

Data-reduction methods using general-purpose analog computer equipment and compatible testing techniques for determining the frequency response of linear physical systems are examined. The techniques considered may be classed as steady state or transient depending on the method of excitation. The relative merits of periodic, slow sweep, and transient (rapid sweep) forcing functions are discussed and applications are given that relate to dynamic-response tests of aeroelastic systems. Two frequency-sweep-input methods are considered in detail. one case the sweep rate is sufficiently slow that the response is approximately the same as that for steady-state conditions. With this input the frequency response can be evaluated and displayed in real time while the test is in progress. Errors due to treating sweep data as steady state can be eliminated, when desired, by reanalyzing tape-recorded time histories of the input and output as transient rather than as periodic data. In the second method the frequency-response function is deter- mined from the system's transient response to a very rapid sweep input. The purpose of frequency sweep in this case is to provide sufficient harmonic content in the input to overcome noise while keeping the test time as short as possible. tests and limited flight-test data presented herein, it appears that a transient-type rapid-sweep forcing function offers a considerable saving in test time while preserving the accuracy possible with steady-state sinusoidal inputs.

Wilmer H. Reed III↗

Development of a hydraulic model of the human systemic circulation

Physical and numeric models of the human circulation are constructed for a number of objectives, including studies and training in physiologic control, interpretation of clinical observations, and testing of prosthetic cardiovascular devices. For many of these purposes it is important to quantitatively validate the dynamic response of the models in terms of the input impedance (Z = oscillatory pressure/oscillatory flow). To address this need, the authors developed an improved physical model. Using a computer study, the authors first identified the configuration of lumped parameter elements in a model of the systemic circulation; the result was a good match with human aortic input impedance with a minimum number of elements. Design, construction, and testing of a hydraulic model analogous to the computer model followed. Numeric results showed that a three element model with two resistors and one compliance produced reasonable matching without undue complication. The subsequent analogous hydraulic model included adjustable resistors incorporating a sliding plate to vary the flow area through a porous material and an adjustable compliance consisting of a variable-volume air chamber. The response of the hydraulic model compared favorably with other circulation models.

NASA Program Biomedical Research and Countermeasur↗

Test Vehicle Forebody Wake Effects on CPAS Parachutes

Parachute drag performance has been reconstructed for a large number of Capsule Parachute Assembly System (CPAS) flight tests. This allows for determining forebody wake effects indirectly through statistical means. When data are available in a "clean" wake, such as behind a slender test vehicle, the relative degradation in performance for other test vehicles can be computed as a Pressure Recovery Fraction (PRF). All four CPAS parachute types were evaluated: Forward Bay Cover Parachutes (FBCPs), Drogues, Pilots, and Mains. Many tests used the missile-shaped Parachute Compartment Drop Test Vehicle (PCDTV) to obtain data at high airspeeds. Other tests used the Orion "boilerplate" Parachute Test Vehicle (PTV) to evaluate parachute performance in a representative heatshield wake. Drag data from both vehicles are normalized to a "capsule" forebody equivalent for Orion simulations. A separate database of PCDTV-specific performance is maintained to accurately predict flight tests. Data are shared among analogous parachutes whenever possible to maximize statistical significance.

Ray, Eric S.↗

Medical Data Architecture Prototype Development - Summary of Recent Work and Proposed Ideas for Upcoming Work

The Medical Data Architecture (MDA) project supports the Exploration Medical Capability (ExMC) risk to minimize or reduce the risk of adverse health outcomes and decrements in performance due to in-flight medical capabilities on human exploration missions. To mitigate this risk, the ExMC MDA project addresses the technical limitations identified in ExMC Gap Med 07: We do not have the capability to comprehensively process medically-relevant information to support medical operations during exploration missions, and in ExMC Gap Med 10: We do not have the capability to provide computed medical decision support during exploration missions. These gaps recognize the need for a comprehensive medical data management system and the accompanying computational support to provide autonomous medical care during long duration exploration missions. As the MDA matures—including the capability to comprehensively process and discover medically-relevant information to support medical operations during exploration missions—project focus will shift to maturing and extending the MDA platform to enable clinical decision support and real-time guidance. To date, the MDA foundational architecture has recommended exploration medical system Level of Care IV requirements through a series of test bed prototype developments and analog demonstrations. The next stage in the development will focus on more autonomous clinical decision making necessary to address challenges in executing a self-contained medical system that enables health care both with and without assistance from ground support. A thorough understanding of current state of medical decision support systems, advanced machine learning algorithms and vast and varied data sources is required. The development of a clinical decision support for exploration missions (Level of Care V) roadmap is needed: one that assesses of current state of the art of clinical decision support systems (CDSS), interoperability issues, identification of challenges in health and performance monitoring, obtaining and processing information from biosensors, knowledge and data management, data integration and fusion, and advanced algorithm development. This roadmap must also include rapid prototype development in the areas of data processing, advanced analysis and prediction of medical events, and treatment based on medically relevant information processing and evidence-based best practices. In this presentation, an overview of the relevant issues and the beginning framework of a Level of Care V CDSS development roadmap will be provided.

Krihak, M.↗

BioSentinel: To the Moon or Beyond?

BioSentinel, an Artemis-1 secondary spacecraft, will carry a biology experiment into deep space for the first time in 50 years. A 6U CubeSat form factor was utilized for the spacecraft and included technologies newly developed or adapted for operations beyond Earth orbit. This is the maiden deep-space voyage for the radio, propulsion system, electrical power system, and BioSensor payload. The spacecraft carries onboard budding yeast, Saccharomyces cerevisiae, as an analog to human cells to test the biological response to deep space radiation. Flying a secondary payload beyond LEO comes with unique challenges with respect to trajectory uncertainty and mission operations planning. BioSentinel does not carry propulsion for trajectory maneuvers, so plans for Comms and Power need to be developed for all trajectories. The nominal plan is a lunar flyby followed by an insertion into Heliocentric orbit. However, some possible scenarios include lunar eclipses that could severely impact the power budget during that phase of the mission, while others could result in a “Retrograde” hyperbola at swingby resulting in the spacecraft traveling inward toward Earth or even towards a collision with the lunar surface. BioSentinel’s final trajectory will not be known until after launch and deployment so possible scenarios need to be planned for ahead of time. This paper discusses the operational scenarios that were planned for as well as the actual execution of the mission operations including: command pass scheduling with the Deep Space Network, selecting bandwidth limits, medium gain antenna versus low gain antenna usage, and conserving power prior to a lunar eclipse. Note: Artemis-1 is planned to launch in the Spring of 2022

BioSentinel↗

Planetary Protection Policy and Technology Developments for the Crewed Exploration of Mars

As part of planning for potential future crewed exploration of Mars, NASA is developing its planetary protection policy for crewed missions, building on concepts developed within the international space exploration community. COSPAR (The Committee on Space Research), together with participating space agencies, has over the last several years organized and held interdisciplinary meetings to consider next steps in addressing knowledge gaps for planetary protection for the first human missions to Mars. Beginning with these workshop discussions as a base, NASA has held follow-on planning activities to identify the necessary steps to be accomplished to close those knowledge gaps. Significant overlap was identified between the planetary protection needs, including; microbial monitoring requirements for crew health and medical systems; studies of the microbiome of the built environment; environmental control and life support system (ECLSS) venting and disinfection strategies; waste management, and; planetary surface operations. In many cases, efforts to mature exploration systems for Mars that are occurring in other technology domains can be leveraged with minor changes to address planetary protection gaps as well. In other cases, work planned for testing on ISS as an analog for Mars transit, or on the lunar surface as an analog for Mars surface operations, can be used to close gaps in current planetary protection capabilities. This presentation provides a status update on the findings of the COSPAR Meetings on this topic to date, together with NASA’s responses in terms of agency-level plans and activities.

James N Benardini↗

BioSentinel SmallSat 2022 Presentation

BioSentinel, an Artemis-1 secondary spacecraft, will carry a biology experiment into deep space for the first time in 50 years. A 6U CubeSat form factor was utilized for the spacecraft and included technologies newly developed or adapted for operations beyond Earth orbit. This is the maiden deep-space voyage for the radio, propulsion system, electrical power system, and BioSensor payload. The spacecraft carries onboard budding yeast, Saccharomyces cerevisiae, as an analog to human cells to test the biological response to deep space radiation.

BioSentinel↗

NASA Goddard Space Flight Center’s Recent Radiation Effects Test Results

Total ionizing dose, displacement damage dose, and single event effects testing were performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include FPGAs, optoelectronics, digital, analog, and bipolar devices.

Single-Event Effects (SEE)↗