Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analytical detection method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Classification and Fusion of Two Disparate Data Streams and Nuclear Dissolutions Application

We consider two streams of data or measurements with disparate qualities and time resolutions that need to be classified. The first stream consists of higher quality data at a coarser time resolution, and the other consists of lower quality data at a finer time resolution. We present a fuser-switch method that fuses the set of classifiers of each stream separately and switches between them. We show that this method provides classification decisions at a finer time resolution with superior detection and false alarm probabilities compared to individual classifiers, under the statistical independence and time resolution ratio conditions. When classifiers are trained using machine learning methods, we show that this superior performance is guaranteed with a confidence probability specified by the classifiers' generalization equations. We use these results to provide analytical foundations for previous practical results that achieved significant performance improvements in classifying Pu/Np target dissolution events at a radiochemical processing facility.

Rao, Nageswara↗

State-of-the-art Instruments for Detecting Extraterrestrial Life

In the coming decades, state-of-the-art spacecraft-based instruments that can detect key components associated with life as we know it on Earth will directly search for extinct or extant extraterrestrial life in our solar system. Advances in our analytical and detection capabilities, especially those based on microscale technologies, will be important in enhancing the abilities of these instruments. Remote sensing investigations of the atmospheres of extrasolar planets could provide evidence of photosynthetic-based life outside our solar system, although less advanced life will remain undetectable by these methods. Finding evidence of extraterrestrial life would have profound consequences both with respect to our understanding of chemical and biological evolution, and whether the biochemistry on Earth is unique in the universe.

Bada, Jeffrey L.↗

Air Coupled Acoustic Thermography (ACAT) Inspection Technique

The scope of this effort is to determine the viability of a new heating technique using a noncontact acoustic excitation source. Because of low coupling between air and the structure, a synchronous detection method is employed. Any reduction in the out of plane stiffness improves the acoustic coupling efficiency and as a result, defective areas have an increase in temperature relative to the surrounding area. Hence a new measurement system, based on air-coupled acoustic energy and synchronous detection is presented. An analytical model of a clamped circular plate is given, experimentally tested, and verified. Repeatability confirms the technique with a measurement uncertainty of plus or minus 6.2 percent. The range of frequencies used was 800-2,000 Hertz. Acoustic excitation and consequent thermal detection of flaws in a helicopter blade is examined and results indicate that air coupled acoustic excitation enables the detection of core damage in sandwich honeycomb structures.

Zalameda, Joseph↗

Automated Lab-on-a-Chip Electrophoresis System

Capillary electrophoresis is an analytical technique that can be used to detect and quantify extremely small amounts of various biological molecules. In the search for biochemical traces of life on other planets, part of this search involves an examination of amino acids, which are the building blocks of life on Earth. The most sensitive method for detecting amino acids is the use of laser induced fluorescence. However, since amino acids do not, in general, fluoresce, they first must be reacted with a fluorescent dye label prior to analysis. After this process is completed, the liquid sample then must be transported into the electrophoresis system. If the system is to be reused multiple times, samples must be added and removed each time. In typical laboratories, this process is performed manually by skilled human operators using standard laboratory equipment. This level of human intervention is not possible if this technology is to be implemented on extraterrestrial targets. Microchip capillary electrophoresis (CE) combined with laser induced fluorescence detection (LIF) was selected as an extremely sensitive method to detect amino acids and other compounds that can be tagged with a fluorescent dye. It is highly desirable to package this technology into an integrated, autonomous, in situ instrument capable of performing CE-LIF on the surface of an extraterrestrial body. However, to be fully autonomous, the CE device must be able to perform a large number of sample preparation and analysis operations without the direct intervention of a human.

Willis, Peter A.↗

Persistent Acoustic Sensing for Monitoring A Reactor Facility

Measurements over the past few years, taking place within the Multi-Informatics for Nuclear Operations Scenarios project, show that infrasound and low-frequency acoustic monitoring can detect, and often quantify, activities that occur on-site at the High Flux Isotope Reactor. Observable activities include: crane translation, lifting, and lowering; differentiation between loaded and unloaded crane operations; access door opening and closing; vehicle operations; and cooling tower fan operations. Advanced data analytic and spectral feature extraction methods can be used to interpret selected signatures to reach a deeper understanding of different reactor activities. These measurements are being conducted using a network of smartphones that continuously operate in conjunction with cloud-based architectures. A recent addition to the system is the development and deployment of a real-time, cloud-based analytic framework that supports near-real-time alarming which can facilitate tip-and-cue protocols. This paper presents recent research in this area including the use of low-frequency acoustics to tip-off transfer operations and cue a more comprehensive analysis by other sensor networks.

42 ENGINEERING↗

How to detect lensing rotation

Gravitational lensing rotation of images is predicted to be negligible at linear order in density perturbations, but can be produced by the post-Born lens-lens coupling at second order. This rotation is somewhat enhanced for Cosmic Microwave Background (CMB) lensing due to the large source path length, but remains small and very challenging to detect directly by CMB lensing reconstruction alone. We show the rotation may be detectable at high significance as a cross-correlation signal between the curl reconstructed with Simons Observatory (SO) or CMB-S4 data, and a template constructed from quadratic combinations of large-scale structure (LSS) tracers. Equivalently, the lensing rotation-tracer-tracer bispectrum can also be detected, where LSS tracers considered include the CMB lensing convergence, galaxy density, and the Cosmic Infrared Background (CIB), or optimal combinations thereof. We forecast that an optimal combination of these tracers can probe post-Born rotation at the level of 5.7σ–6.1σ with SO and 13.6σ–14.7σ for CMB-S4, depending on whether standard quadratic estimators or maximum a posteriori iterative methods are deployed. We also show possible improvement up to 21.3σ using a CMB-S4 deep patch observation with polarization-only iterative lensing reconstruction. However, these cross-correlation signals have non-zero bias because the rotation template is quadratic in the tracers, and exists even if the lensing is rotation free. We estimate this bias analytically, and test it using simple null-hypothesis simulations to confirm that the bias remains subdominant to the rotation signal of interest. Detection and then measurement of the lensing rotation cross-spectrum is therefore a realistic target for future observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of the dielectric properties of simulated comet material as part of the KOSI 10 experiment

The dielectric constant epsilon of the snow-mineral used for the comet simulation in the German KOSI 10 experiment was measured in the radio frequency range from 2 to 4 GHz. The traditional microwave bridge method was used, but instead of using a waveguide that contains the sample material small lambda/4 antennas were used as sensors. A change in the dielectric properties indicates a change in density and/or composition, respectively. The method is presented as an analytical tool for measuring such density or composition changes during alteration snow-dust materials. The KOSI (determined from the German: Kometen Simulation) experiments, performed in the Space simulator of the DLR/Institut for Raumsimulation, during the last years revealed many processes that presumably take place on comets. So far, modifications of the internal structure could be identified only during the post-experiment inspection via hardness tests. It was the aim of the KOSI 10 and KOSI 10a experiments to emphasize on a synoptic detection of events like particle emission or crust formation. The composition of the KOSI 10 sample material was an ice-mineral mixture with about 10 percent mineral (olivine) content. An excellent method to investigate the change of the density of the probe material during its exposure to the artificial sun in situ is to do it via the measurement of the dielectric constant. The traditional method to determine epsilon, by using a microwave-bridge to measure the transmission and the reflection factor of the sample material for electromagnetic waves in the radio frequency range, was modified, since the commonly used practice to fill the sample material into a waveguide was not compatible with the need for in situ measurements during the simulation experiment.

Ulamec, S.↗

Laboratory measurements and a theoretical analysis of the TCT fading channel radio system

This paper documents the laboratory and theoretical performance of a pilot-aided digital radio system. The technique considered transmits a midband pilot tone to improve the receiver data detection performance in a multipath fading channel and is referred to as the tone calibrated technique (TCT). The performance of a 860 MHz prototype system carrying 2.4 kbit/s data under Rician fading conditions is reported. Both experimental and analytical results show that the error floor experienced with nonpilot-aided transmission methods is effectively removed by the TCT scheme, resulting in significant performance gains at high signal-to-noise ratio values. The paper also examines the TCT system performance under typical operating conditions and presents a new analysis of the TCT theoretical error probability.

Rafferty, William↗

A microarray immunoassay for simultaneous detection of proteins and bacteria

We report the development and characterization of an antibody microarray biosensor for the rapid detection of both protein and bacterial analytes under flow conditions. Using a noncontact microarray printer, biotinylated capture antibodies were immobilized at discrete locations on the surface of an avidin-coated glass microscope slide. Preservation of capture antibody function during the deposition process was accomplished with the use of a low-salt buffer containing sucrose and bovine serum albumin. The slide was fitted with a six-channel flow module that conducted analyte-containing solutions over the array of capture antibody microspots. Detection of bound analyte was subsequently achieved using fluorescent tracer antibodies. The pattern of fluorescent complexes was interrogated using a scanning confocal microscope equipped with a 635-nm laser. This microarray system was employed to detect protein and bacterial analytes both individually and in samples containing mixtures of analytes. Assays were completed in 15 min, and detection of cholera toxin, staphylococcal enterotoxin B, ricin, and Bacillus globigii was demonstrated at levels as low as 8 ng/mL, 4 ng/mL, 10 ng/mL, and 6.2 x 10(4) cfu/mL, respectively. The assays presented here are very fast, as compared to previously published methods for measuring antibody-antigen interactions using microarrays (minutes versus hours).

Non-NASA Center↗

Nanoscale Surface Plasmonics Sensor With Nanofluidic Control

Conventional quantitative protein assays of bodily fluids typically involve multiple steps to obtain desired measurements. Such methods are not well suited for fast and accurate assay measurements in austere environments such as spaceflight and in the aftermath of disasters. Consequently, there is a need for a protein assay technology capable of routinely monitoring proteins in austere environments. For example, there is an immediate need for a urine protein assay to assess astronaut renal health during spaceflight. The disclosed nanoscale surface plasmonics sensor provides a core detection method that can be integrated to a lab-on-chip device that satisfies the unmet need for such a protein assay technology. Assays based upon combinations of nanoholes, nanorings, and nanoslits with transmission surface plasmon resonance (SPR) are used for assays requiring extreme sensitivity, and are capable of detecting specific analytes at concentrations as low as picomole to femtomole level in well-controlled environments. The device operates in a transmission mode configuration in which light is directed at one planar surface of the array, which functions as an optical aperture. The incident light induces surface plasmon light transmission from the opposite surface of the array. The presence of a target analyte is detected by changes in the spectrum of light transmitted by the array when a target analyte induces a change in the refractive index of the fluid within the nanochannels. This occurs, for example, when a target analyte binds to a receptor fixed to the walls of the nanochannels in the array. Independent fluid handling capability for individual nanoarrays on a nanofluidic chip containing a plurality of nanochannel arrays allows each array to be used to sense a different target analyte and/or for paired arrays to analyze control and test samples simultaneously in parallel. The present invention incorporates transmission mode nanoplasmonics and nanofluidics into a single, microfluidically controlled device. The device comprises one or more arrays of aligned nanochannels that are in fluid communication with inflowing and outflowing fluid handling manifolds that control the flow of fluid through the arrays. The array acts as an aperture in a plasmonic sensor. Fluid, in the form of a liquid or a gas and comprising a sample for analysis, is moved from an inlet manifold through the nanochannel array, and out through an exit manifold. The fluid may also contain a reagent used to modify the interior surfaces of the nanochannels, and/or a reagent required for the detection of an analyte.

Wei, Jianjun↗

Ultrasonic degradation of GenX (HFPO-DA) – Performance comparison to PFOA and PFOS at high frequencies

Sonolytic degradation kinetics of hexafluoropropylene oxide-dimer acid (HFPO-DA or GenX) were studied for the first time at four high ultrasonic frequencies (375, 580, 860 and 1,140kHz) and three power densities (200, 300 and 400W/L), and compared to the degradation of previously studied perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS). The frequency of 580kHz displayed the highest degradation of all three PFAS tested. Within each frequency, the degradation performance increased consistently with increasing power density. Degradation rates were highest for GenX over PFOA to PFOS (k GenX = 0.0501 min -1 , k PFOA = 0.0444 min -1 , k PFOS 0.0153 min -1 ), which is in direct agreement with their reported thermal stability (PFOS > PFOA > GenX). No known by-product formation as expected from the literature on truncation mechanism was detected in the samples (i.e. shorter chain carboxylic acid PFAS). Further, fluorine mass balance experiments at 580kHz and 400W/ L confirmed that GenX defluorinated fastest among the three tested PFAS and had lowest loss of fluorine in the mass balance. Degradation experiments with a mixture of all three PFAS displayed lower degradation rates than the individual experiments, where PFOA exhibited the largest reduction in degradation rate (by 31%), followed by GenX (by 19%), and finally by PFOS (by 17%). Overall, our study demonstrates that ultrasound can provide effective destruction of different PFAS (70-90% fluorine from mitigated PFAS was detected as inorganic fluoride) with a similar energy demand to alternative PFAS treatment methods reported in literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detecting Low-level Radiation Sources Using Border Monitoring Gamma Sensors

We consider a problem of detecting a low-level radiation source using a network of Gamma spectral sensors placed on the periphery of a monitored region. We propose a computationally light-weight, correlation-based method which is primarily intended for systems with limited computing capacity. Sensor measurements are combined at the fusion by first generating decisions at each time step and then taking their majority vote within a time widow. At each time step, decisions are generated using two strategies: (i) SUM method based on a threshold decision on a correlation statistic derived from measurements from all sensors, and (ii) OR method based on logical-OR of threshold decisions based on correlations statistics of individual sensor measurements. We derive analytical performance bounds for false alarm rates of SUM and OR methods, and show that their performance is enhanced by the temporal smoothing of majority vote within a time window. Using measurements from a test campaign, we generate a border monitoring scenario with twelve 2"x2" NaI Gamma sensors deployed on the periphery of 42m x 42m outdoor region. A Cs-137 source is moved in a straight-line across this region, starting several meters outside and finally moving away from it. We illustrate the performance of both correlation-based detection methods, and compare their performances with each other and with a particle filter method. Overall, under small false-alarm conditions, the OR fusion is found to produce better detection performance.

Sen, Satyabrata↗

Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS

The ability to directly measure uranium isotope ratios on environmental swipes has been achieved through a solution-based microextraction process and represents a significant advancement toward the development of a rapid method to analyze international nuclear safeguard samples. Here, a microextraction probe is lowered and sealed onto the swipe surface, and analytes within the sampling site (~8 mm2) are dissolved and extracted into a flowing solvent of 2% nitric acid (HNO 3 ). The mobilized species are subsequently directed into an inductively coupled plasma-mass spectrometer (ICP-MS) for accurate and precise isotope ratio determination. This work highlights the novelty of the sampling mechanism, particularly with the direct coupling of the microextraction probe to the ICP-MS and measurement of uranium isotope ratios. The preliminary method detection limit for the microextraction-ICP-MS method, utilizing a quadrupole-based MS, was determined to be ~50 pg of 238 U. Additionally, precise and accurate isotope ratio measurements were achieved on uranium reference materials for both the major ( 235 U/ 238 U) and minor ( 234 U/ 238 U and 236 U/ 238 U) ratios. While the present work is focused on directly measuring uranium isotopic systems on swipe surfaces for nuclear safeguards and verification applications, the benefits would extend across many applications in which direct solid sampling is sought for elemental and isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SEDONA SpEctroscopic Detection Of Nerve Agents

Although the threat of a liquid explosive attack on a passenger aircraft has been mitigated by limiting the size of carry-on bottles, highly potent chemicals (e.g., nerve agents) are a very serious threat. A single travel bottle full of such chemicals would cause great harm to many people and create a national security incident disrupting civilian air travel. Current screening methods to detect highly potent chemicals require opening a closed bottle. Experts at Los Alamos National Laboratory have developed SEDONA, a low magnetic field nuclear magnetic resonance (NMR) to detect chemical threats through unopened bottles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine Learning Using Open Data Sources for Detection of Nuclear Proliferation Activities (U)

In FY2020, Savannah River National Laboratory (SRNL) in collaboration with the Sanghani Center for Artificial Intelligence and Data Analytics (SCAIDA) at Virginia Polytechnic Institute and State University (VT) and funded by the Department of Energy’s (DOE) Defense Nuclear Nonproliferation Research and Development, began developing a demonstration prototype system that uses multiple machine learning and data analytic methods on large-scale open data sources to identify new, developing, and/or undeclared nuclear programs. Using the announcement in May 2018 of the proposed Savannah River Plutonium Processing Facility (SRPPF) as a test subject, the goal of this 2-year project is to forecast the SRPPF using only data prior to May 2018. The project work is split into a preliminary prototype development for the first year with an initial evaluation of viability followed by the second year of development to create an integrated prototype system and more extensive performance evaluation. This report documents the results of the preliminary-phase tasks.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Chemiluminescent measurement of atmospheric acid

The design and construction of a gas phase acid sensitive analyzer are reported. These studies showed that the chemical system was a practical analytical method. A complete instrument was developed and prepared for field testing. A Titan 3-C rocket was scheduled for launching on February 11, 1974. Through preparations made by NASA Langley the instrument was set up to monitor the acid concentration in the rocket exhaust. Due to adverse wind conditions no acid was detected. This entire trip is described in detail.

Stedman, D. H.↗

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗