Search NASA⌕ Search

SEARCH · Search NASA

Results for “BACKGROUND RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Evaluating Radiation Impact on Transmon Qubits Using a Fast Decay Protocol in Above and Underground Laboratories

Superconducting qubits can be sensitive to sudden energy deposits caused by ambient radioactivity and cosmic rays. Previous studies have focused on understanding possible correlated effects over time and distance due to this radiation. In this study‚ for the first time‚ we directly compare the response of a transmon qubit measured initially at the SQMS above-ground facility (Fermilab‚ Illinois‚ USA) and then at the deep underground Gran Sasso Laboratory (INFN-LNGS‚ Italy). We observe the same average qubit lifetime of roughly 80 microseconds at both facilities. We then apply a fast decay detection protocol and investigate the time structure and relative rates of triggered events due to radiation versus intrinsic noise‚ comparing the above and underground performance of several high-coherence qubits. Using gamma sources of variable intensity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source‚ and it is possible to detect particle impacts. However‚ we do not observe a difference in radiation-induced-like events when comparing the above and underground results for niobium-based transmon qubits with sapphire substrates. We conclude that the majority of these events are not radiation-related and are attributed to other noise sources‚ which by far dominate single-qubit errors in modern transmon qubits. [1] Dominicis‚ Roy et al. arXiv:2405.18355

Roy, Tanay↗

Pregalactic black holes - A new constraint

Pregalactic black holes accrete matter in the early universe and produce copious amounts of X radiation. By using observations of the background radiation in the X and gamma wavebands, a strong constraint is imposed upon their possible abundance. If pregalactic black holes are actually present, several outstanding problems of cosmogony can be resolved with typical pregalactic black hole masses of 100 solar masses. Significantly more massive holes cannot constitute an appreciable mass fraction of the universe and are limited by a specific mass-density bound.

Barrow, J. D.↗

Shielding and Build-up Considerations for Radiation Detection

Abstract -- Shielding for gamma radiation has traditionally focused on the reduction of dose effects. For these applications, reducing the energy of the radiation is important along with reducing the actual number of photons, and therefore large masses of high Z material are typically used. However, for measurements requiring low backgrounds or for detecting low activity signals, such as in homeland security applications, the primary use of shielding is to decrease the total number of background photons (perhaps in a region of interest), and therefore the processes of buildup and down scattering become important. In these applications, where the important measure is count rate instead of dose and low background are important, improved reduction in counts from background radiation may be achieved with specially designed configurations of thin layers of different materials instead of a single thick layer. This paper briefly describes recent modeling and experimental investigations in layered-shielding methodology and provides results with comparison to single shielding material such as Pb. Application of these techniques to some real world problems, such as detector systems for homeland security, is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

Seasonal Variation of Indoor Radon Concentration in the Tropics: Comparative studies between Kuala Lumpur, Malaysia and Kerala, India

The radiation dose received by man from indoor radon and its progeny is the largest at more than 50% of total dose received. The seasonal variation of indoor radon concentration in Kerala, India and Kuala Lumpur, Malaysia were studied. The Southwest coast of the Kerala state in India is known to have very high levels of natural background radiation owing to the rare earths rich monazite sand available in large amount. Kuala Lumpur, Malaysia used to be a famous tin mining area where it was done using open cast system. One-year measurements of radon concentration in houses were done for these two regions. It was found that there is considerable seasonal variation in the levels of radon in Kerala but the variation in Kuala Lumpur is only less than 10%.

58 GEOSCIENCES↗

Flux and Photon Spectral Index Distributions of Fermi-LAT Blazars and Contribution to the Extragalactic Gamma-ray Background

We present a determination of the distributions of gamma-ray flux - the so called LogN-LogS relation - and photon spectral index for the 352 blazars detected with a greater than approximately seven sigma detection threshold and located above {+-} 20{sup o} Galactic latitude by the Large Area Telescope of the Fermi Gamma-ray Space Telescope in its first year catalog. Because the flux detection threshold depends on the photon index, the observed raw distributions do not provide the true LogN-LogS counts or the true distribution of the photon index. We use the non-parametric methods developed by Efron and Petrosian to reconstruct the intrinsic distributions from the observed ones which account for the data truncations introduced by observational bias and includes the effects of the possible correlation among the two variables. We demonstrate the robustness of our procedures using a simulated data set of blazars and then apply these to the real data and find that for the population as a whole the intrinsic flux distribution can be represented by a broken power law of slopes -2.37 {+-} 0.13 and -1.70 {+-} 0.26, and the intrinsic photon index distribution can be represented by a Gaussian with mean 2.41 {+-} 0.13 and 1{sigma} width of 0.25 {+-} 0.03. We also find the intrinsic distributions for the sub-populations of BL Lac and FSRQs type blazars separately. We then calculate the contribution of blazars to the diffuse cosmic gamma-ray background radiation to be 28% {+-} 19%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A NEW ALGORITHM FOR RADIOISOTOPE IDENTIFICATION OF SHIELDED AND MASKED SNM/RDD MATERIALS

Detection and identification of shielded and masked nuclear materials is crucial to national security, but vast borders and high volumes of traffic impose stringent requirements for practical detection systems. Such tools must be be mobile, and hence low power, provide a low false alarm rate, and be sufficiently robust to be operable by non-technical personnel. Currently fielded systems have not achieved all of these requirements simultaneously. Transport modeling such as that done in GADRAS is able to predict observed spectra to a high degree of fidelity; our research is focusing on a radionuclide identification algorithm that inverts this modeling within the constraints imposed by a handheld device. Key components of this work include incorporation of uncertainty as a function of both the background radiation estimate and the hypothesized sources, dimensionality reduction, and nonnegative matrix factorization. We have partially evaluated performance of our algorithm on a third-party data collection made with two different sodium iodide detection devices. Initial results indicate, with caveats, that our algorithm performs as good as or better than the on-board identification algorithms. The system developed was based on a probabilistic approach with an improved approach to variance modeling relative to past work. This system was chosen based on technical innovation and system performance over algorithms developed at two competing research institutions. One key outcome of this probabilistic approach was the development of an intuitive measure of confidence which was indeed useful enough that a classification algorithm was developed based around alarming on high confidence targets. This paper will present and discuss results of this novel approach to accurately identifying shielded or masked radioisotopes with radiation detection systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WE-D-BRF-03: Proton Beam Range Verification with a Single Prompt Gamma-Ray Detector

Purpose: To present an experimental study of a novel range verification method for scanned and scattered proton beams. Methods: A detection system consisting of an actively shielded lanthanum(III)bromide scintillator and a one-sided lead collimator was used to measure prompt gamma-rays emitted during the delivery of proton beams to a water phantom and an anthropomorphic head phantom. The residual proton range at the collimator position was determined by comparing gamma-ray intensities while the proton energy was modulated to the distal end of the target. We used a clinical field to deliver a 50 cGy dose to a 12 cm diameter target in the water phantom and to a 175 cc tumor-shaped target in the head phantom. The detector signals were acquired with a custom data acquisition system enabling energy and time-of-flight discrimination of prompt gamma-rays. Results: Range deviations were detected with a statistical accuracy of ± 0.2 mm and ± 1.4 mm at 90% confidence level, respectively for the water and head phantom. We obtained a time resolution of 1 ns FWHM and an energy resolution < 2% FWHM for the main gamma lines from proton-induced nuclear reactions with carbon and oxygen. This allowed for an accurate separation of the prompt gamma-rays from neutron-induced background. Conclusion: Proton range deviations can be detected with millimeter accuracy using a single prompt gamma-ray measurement point acquired during the delivery of a few proton energy layers to the distal part of the target. The method is also feasible in the presence of background radiation from passively scattered proton beam delivery.

60 APPLIED LIFE SCIENCES↗

Modeling the Effect of High Background Mitigation Techniques on Radiation Portal Monitors

The Oak Ridge National Laboratory (ORNL) has been tasked by the United States National Nuclear Security Administration’s Second Line of Defense (SLD) program with determining a viable method for mitigating high background radiation levels in radiation portal monitors (RPM). High background radiation levels adversely affect the ability of RPMs to detect small sources of radiation. For this reason, it is desirable to install RPMs in low background environments where a low false alarm rate can be achieved and small deviations in detector signals are able to trigger alarms. To investigate the mitigation of high background levels, a test bed was established at ORNL capable of reproducing many factors that contribute to radiation background levels. The controlled environment of the test bed allows the isolation of a variety of factors that influence background and are difficult to accurately characterize in the field. In this work, the test bed is used to characterize numerous RPM configurations encountered in the field and provide a benchmark for modeling RPM background levels. Accurately modeling the background measured by a RPM allows future background remediation techniques to first be modeled to test their validity before being installed in the field. The utilization of these tools can yield a cost savings to the program by minimizing costly field installations and understanding the outcome of remediation techniques prior to widespread implementation.

Guzzardo, Tyler↗

Gamma-ray luminosity and photon index evolution of FSRQ blazars and contribution to the gamma-ray background

We present the redshift evolutions and distributions of the gamma-ray luminosity and photon spectral index of flat spectrum radio quasar (FSRQ) type blazars, using non-parametric methods to obtain the evolutions and distributions directly from the data. The sample we use for analysis consists of almost all FSRQs observed with a greater than approximately 7σ detection threshold in the first-year catalog of the Fermi Gamma-ray Space Telescope's Large Area Telescope, with redshifts as determined from optical spectroscopy by Shaw et al. We find that FSQRs undergo rapid gamma-ray luminosity evolution, but negligible photon index evolution, with redshift. With these evolutions accounted for we determine the density evolution and luminosity function of FSRQs and calculate their total contribution to the extragalactic gamma-ray background radiation, resolved and unresolved, which is found to be 16(+10/–4)%, in agreement with previous studies.

79 ASTRONOMY AND ASTROPHYSICS↗

PHOTON-INDUCED EVOLUTIONARY RATES OF LiHe{sup +} ({sup 1}{Sigma}{sup +}) IN EARLY UNIVERSE FROM ACCURATE QUANTUM COMPUTATIONS

The radiative association rates for the formation of LiHe{sup +} molecules in their ground electronic state have been calculated employing an accurate ab initio potential energy curve and the dipole moment function. The enhancement of this rate, which may arise from stabilizing emissions stimulated by the cosmic background radiation field, has also been calculated and analyzed in the context of early universe conditions. Direct photodissociation processes have also been studied using local thermal equilibrium cross sections and rates are reported for temperatures between 600 and 9000 K. These photochemical processes are in turn analyzed and discussed as a function of the redshift z that is expected to operate in the early universe chemical kinetics. All data suggest very low residual abundances of this molecule and therefore its marginal role within early universe chemistry.

74 ATOMIC AND MOLECULAR PHYSICS↗

The extreme limit of the generalised Chaplygin gas

Unified Dark Matter models describe Dark Matter and Dark Energy as a single entity which is, in the simplest case, embodied in a perfect barotropic fluid. It is a well-established fact that small adiabatic perturbations of Unified Dark Matter have an evolution characterised by oscillations and decay which provide predictions on the Cosmic Background Radiation anisotropies which are in poor agreement with observation. In this paper we investigate the generalised Chaplygin gas and we find that the Integrated Sachs-Wolfe effect excludes the model for 10{sup −3} < α < 350. We discuss the implications on the background evolution of the Universe if large values of α are considered. In this case, the Universe expansion mimics a matter-dominated phase abruptly followed by a de Sitter one at the transition redshift z{sub tr}. Thanks to an analysis of the type Ia supernovae Constitution set we are able to place z{sub tr} = 0.22.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of radiation exposure and associated radiation-induced cancer risks from mammography and molecular imaging of the breast

Purpose: Recent studies have raised concerns about exposure to low-dose ionizing radiation from medical imaging procedures. Little has been published regarding the relative exposure and risks associated with breast imaging techniques such as breast specific gamma imaging (BSGI), molecular breast imaging (MBI), or positron emission mammography (PEM). The purpose of this article was to estimate and compare the risks of radiation-induced cancer from mammography and techniques such as PEM, BSGI, and MBI in a screening environment. Methods: The authors used a common scheme for all estimates of cancer incidence and mortality based on the excess absolute risk model from the BEIR VII report. The lifetime attributable risk model was used to estimate the lifetime risk of radiation-induced breast cancer incidence and mortality. All estimates of cancer incidence and mortality were based on a population of 100 000 females followed from birth to age 80 and adjusted for the fraction that survives to various ages between 0 and 80. Assuming annual screening from ages 40 to 80 and from ages 50 to 80, the cumulative cancer incidence and mortality attributed to digital mammography, screen-film mammography, MBI, BSGI, and PEM was calculated. The corresponding cancer incidence and mortality from natural background radiation was calculated as a useful reference. Assuming a 15%-32% reduction in mortality from screening, the benefit/risk ratio for the different imaging modalities was evaluated. Results: Using conventional doses of 925 MBq Tc-99m sestamibi for MBI and BSGI and 370 MBq F-18 FDG for PEM, the cumulative cancer incidence and mortality were found to be 15-30 times higher than digital mammography. The benefit/risk ratio for annual digital mammography was >50:1 for both the 40-80 and 50-80 screening groups, but dropped to 3:1 for the 40-49 age group. If the primary use of MBI, BSGI, and PEM is in women with dense breast tissue, then the administered doses need to be in the range 75-150 MBq for Tc-99m sestamibi and 35 MBq-70 MBq for F-18 FDG in order to obtain benefit/risk ratios comparable to those of mammography in these age groups. These dose ranges should be achievable with enhancements to current technology while maintaining a reasonable examination time. Conclusions: The results of the dose estimates in this study clearly indicate that if molecular imaging techniques are to be of value in screening for breast cancer, then the administered doses need to be substantially reduced to better match the effective doses of mammography.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiple-Coincidence Active Neutron Interrogation of Fissionable Materials

In an extension of the Associated Particle Imaging technique that is used for the detection and imaging of hidden explosives, the present measurements use a beam of tagged 14.1 MeV neutrons in coincidence with two or more gammas to probe for the presence of fissionable materials. We have measured neutron-gamma-gamma coincidences with targets of depleted uranium, tungsten, lead, iron, and carbon and will present results that show the multiple-coincidence counting rate for the depleted uranium is substantially higher than any of the non-fissionable materials. In addition, the presence of coincidences involving delayed particle spectra provides a signature for fissionable materials that is distinct from that for non-fissionable ones. Information from the tagged neutron involved in the coincidence event is used to compute the position of the fissionable material in all three dimensions. The result is an imaging probe for fissionable materials that is compact and portable, and produces relatively low levels of background radiation. Simultaneous measurements on packages of interest for both explosives and fissionable materials are now feasible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TeV gamma rays from 3C 279 - A possible probe of origin and intergalactic infrared radiation fields

The gamma-ray spectrum of 3C 279 during 1991 June exhibited a near-perfect power law between 50 MeV and over 5 GeV with a differential spectral index of -(2.02 +/- 0.07). If extrapolated, the gamma-ray spectrum of 3C 279 should be easily detectable with first-generation air Cerenkov detectors operating above about 0.3 TeV provided there is no intergalactic absorption. However, by using model-dependent lower and upper limits for the extragalactic infrared background radiation field, a sharp cutoff of the 3C 279 spectrum is predicted at between about 0.1 and about 1 TeV. The sensitivity of present air Cerenkov detectors is good enough to measure such a cutoff, which would provide the first opportunity to obtain a measurement of the extragalactic background infrared radiation field.

Stecker, F. W.↗

Design and Testing of a Novel Wide Range - Segmented Gamma Scanner Incorporating Tomographic Gamma Scanning for Measuring Both Low and Intermediate Level Waste in Drums - 13470

This paper describes the design and testing of a novel automated Wide Range Segmented Gamma ray Scanning (WR-SGS) assay instrument that also incorporates Tomographic Gamma Scanning (TGS). The instrument is designed for the measurement of both Low and Intermediate Level Waste (LLW and ILW) in 200 litre drums and other waste containers covering a wide range of density. Like earlier ANTECH WR-SGS instruments, the system employs a single shielded and collimated high purity germanium (HPGe) detector to quantify the radionuclide content of the waste and like conventional SGS instruments it is suitable for the measurement of relatively homogeneous waste matrices. Also, like earlier WR-SGS systems the instrument incorporates an automated variable aperture collimator, which allows the vertical segment height to be adjusted in order to measure both high dose-rate and very low activity drums. The instrument employs both conventional discrete SGS vertical segment measurements as well as vertical segment measurement by continuous helical-scanning of the drum as it rotates. This latter method reduces measurement times for SGS measurements. In order to determine the density corrections for both low and high-density drums, a high activity Eu-152 transmission source is employed. When not in use, and in place of a conventional shutter mechanism, the shielded transmission source is moved to a shielded storage position to eliminate background radiation from the source. Due to its novel features, the WR-SGS is applicable to the measurement of both very low and very high activity waste drums as well as waste drums with a wide range of density. If located in a low background position and with the effective shielding of the strong transmission source, the instrument can be used to measure very low level or exempt waste. In order to extend the range of applicability to the measurement of heterogeneous drums, TGS measurement capability has been included in the basic WR-SGS design. This is achieved by adding horizontal motion to the waste drum rotation platform and incorporating TGS collimation into the variable aperture collimator, as well as a filter to reduce the detector signal when straight-through measurements are made using the strong transmission source. Test measurements are presented of the system operating in both SGS and TGS modes using different drum densities and source strengths. The test measurement results are compared with benchmarked MCNP Monte Carlo calculations. The Wide Range SGS - TGS instrument extends the range of both activity and density that can be measured in 200 and 340 litre drums. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reanalysis of the Apollo cosmic gamma-ray spectrum in the 0.3 to 10 MeV energy region

Additional data obtained from the Apollo-16 and -17 missions, together with collateral calculations on background radiation effects, have enabled an improved subtraction of unwanted backgrounds from the diffuse cosmic gamma-ray data previously reported from Apollo-15. As a result, the 1- to 10-MeV spectrum is lowered significantly and connects smoothly with recent data at other energies. The inflection reported previously is much less pronounced and has no more than a 1.5-sigma significance. Sky occultation by the Apollo-16 spacecraft shows the bulk of the 0.3- to 1-MeV radiation to be diffuse. The analysis of spurious backgrounds points to important improvements for future experiments designed for this spectral region.

Trombka, J. I.↗