Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Three-Dimensional Particle-in-Cell Analysis of Mechanical Design Tolerances of the Scorpius Injector With Warp

Here, this article examines the mechanical design tolerances for the Scorpius injector using a 3-D particle-in-cell (PIC) code. In order to meet its objective as a high-fidelity, multipulse flash X-ray source, the accelerator has requirements for the electron beam in order to minimize the spot size of the beam focused onto a foil target to create high fluence X-rays at energies greater than 10 MeV. The requirements for alignment of the cathode, anode beam pipe, focusing solenoids, and transport solenoids specified using Trak and AMBER are independently verified using a 3-D electrostatic/magnetostatic model of the Scorpius injector, including transverse magnetic field errors that arise from mechanical alignment errors. It is predicted that the injector will meet the performance requirements for radiographic operation and has a design margin to correct for potentially unforeseen operating conditions.

42 ENGINEERING↗

Charged particle track reconstruction with SπRIT Time Projection Chamber

In this work, we present a software framework, SπRITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the SRIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlapping pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from 132 Sn + 124 Sn collision events with beam energy of 270 AMeV. Particle identification is established using < dE/dx >and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incident beamline design for a modern cold triple axis spectrometer at the High Flux Isotope Reactor

A modern cold triple axis spectrometer is being planned for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Here, we describe the design of an incident beamline that will put a flux of ~ 10 8 $\frac {n}{cm^{2}s}$ on a sample with an area of 2 cm X 2 cm. It takes current physical constraints at HFIR into account and it can accommodate both single and multiplexed analyzer-detector secondary spectrometers and large superconducting magnets. The proposed incident beamline includes a multi-channel guide with horizontal focusing, a neutron velocity selector, components to facilitate an incident beam polarization option, and a double-focusing pyrolytic graphite monochromator. Here, this work describes the process of optimizing the guide system and monochromator and summarizes the expected performance of the incident beamline for non-polarized operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controlled motion of domain walls in submicron amorphous wires

Results on the control of the domain wall displacement in cylindrical Fe{sub 77.5}Si{sub 7.5}B{sub 15} amorphous glass-coated submicron wires prepared by rapid quenching from the melt are reported. The control methods have relied on conical notches with various depths, up to a few tens of nm, made in the glass coating and in the metallic nucleus using a focused ion beam (FIB) system, and on the use of small nucleation coils at one of the sample ends in order to apply magnetic field pulses aimed to enhance the nucleation of reverse domains. The notch-based method is used for the first time in the case of cylindrical ultrathin wires. The results show that the most efficient technique of controlling the domain wall motion in this type of samples is the simultaneous use of notches and nucleation coils. Their effect depends on wire diameter, notch depth, its position on the wire length, and characteristics of the applied pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-416: Experimental Evaluation of a Commercial GPU-Based Monte Carlo Dose Calculation Algorithm

Purpose: A new commercial GPU-based Monte Carlo dose calculation algorithm (GPUMCD) developed by the vendor Elekta™ to be used in the Monaco Treatment Planning System (TPS) is capable of modeling dose for both a standard linear accelerator and for an Elekta MRI-Linear accelerator (modeling magnetic field effects). We are evaluating this algorithm in two parts: commissioning the algorithm for an Elekta Agility linear accelerator (the focus of this work) and evaluating the algorithm’s ability to model magnetic field effects for an MRI-linear accelerator. Methods: A beam model was developed in the Monaco TPS (v.5.09.06) using the commissioned beam data for a 6MV Agility linac. A heterogeneous phantom representing tumor-in-lung, lung, bone-in-tissue, and prosthetic was designed/built. Dose calculations in Monaco were done using the current clinical algorithm (XVMC) and the new GPUMCD algorithm (1 mm3 voxel size, 0.5% statistical uncertainty) and in the Pinnacle TPS using the collapsed cone convolution (CCC) algorithm. These were compared with the measured doses using an ionization chamber (A1SL) and Gafchromic EBT3 films for 2×2 cm{sup 2}, 5×5 cm{sup 2}, and 10×10 cm{sup 2} field sizes. Results: The calculated central axis percentage depth doses (PDDs) in homogeneous solid water were within 2% compared to measurements for XVMC and GPUMCD. For tumor-in-lung and lung phantoms, doses calculated by all of the algorithms were within the experimental uncertainty of the measurements (±2% in the homogeneous phantom and ±3% for the tumor-in-lung or lung phantoms), except for 2×2 cm{sup 2} field size where only the CCC algorithm differs from film by 5% in the lung region. The analysis for bone-in-tissue and the prosthetic phantoms are ongoing. Conclusion: The new GPUMCD algorithm calculated dose comparable to both the XVMC algorithm and to measurements in both a homogeneous solid water medium and the heterogeneous phantom representing lung or tumor-in-lung for 2×2 cm{sup 2}-10×10 cm{sup 2} field sizes. Funding support was obtained from Elekta.

60 APPLIED LIFE SCIENCES↗

Ribbon electron beam formation by a forevacuum plasma electron source

Results of the numerical analysis and experimental research on ribbon electron beam generation based on hollow cathode discharge at forevacuum gas pressure are presented. Geometry of the accelerating gap has modified. It lets us focus the ribbon electron beam and to transport it on a distance of several tens of centimeters in the absence of an axial magnetic field. The results of numerical simulations are confirmed by the experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

20-24 GeV FFA CEBAF Energy Upgrade

A proposal was formulated to increase the CEBAF energy from the present 12 GeV to 20-24 GeV by replacing the highest-energy arcs with Fixed Field Alternating Gradient (FFA) arcs. The new pair of arcs would provide six or seven new beam passes, going through this magnet array, allowing the energy to be nearly doubled using the existing CEBAF SRF cavity system. One of the immediate accelerator design tasks is to develop a proof-of-principle FFA arc magnet lattice that would support simultaneous transport of 6-7 passes with energies spanning a factor of two. We also examine the possibility of using combined function magnets to configure a cascade, six-way beam split switchyard. Finally, a novel multi-pass linac optics based on a weakly focusing lattice is being explored.

Bogacz, Slawomir Alex↗

CEBAF FFA Energy Upgrade

Encouraged by recent success of CBETA, a proposal was formulated to increase the CEBAF energy from the present 12 GeV to 20-24 GeV by replacing the highest-energy arcs with Fixed Field Alternating Gradient (FFA) arcs. The new pair of arcs would provide six or seven new beam passes, going through this magnet array, allowing the energy to be nearly doubled using the existing CEBAF SRF cavity system. One of the immediate accelerator design tasks is to develop a proof-of-principle FFA arc magnet lattice that would support simultaneous transport of 6-7 passes, with energies spanning a factor of two. We also examine a possibility of using combined function magnets to configure a cascade, six-way beam split switchyard. Finally, a novel, multi-pass linac optics based on a triplet focusing lattice is being explored.

Bogacz, S.↗

Tapered helical undulator system for high efficiency energy extraction from a high brightness electron beam

In this work we discuss the design choices and construction strategy of the tapered undulator system designed for a high energy extraction efficiency experiment in the ultraviolet region of the electromagnetic spectrum planned for installation at the Argonne National Laboratory Linac Extension Area (LEA) beamline. The undulator is comprised of 4 sections pure permanent magnet Halbach array separated by short break sections, each one of them housing a focusing quadrupole doublet and a phase shifter. The quadrupoles use a novel hybrid design which allows one to vary the gradient and match the beam transversely. Finally, the undulator tapering profile is optimized to maximize the energy conversion efficiency from a 340 MeV 1 kA beam into coherent 257.5 nm radiation taking into account the longitudinal current profile generated by the linac.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the LBNE Beamline

The Long Baseline Neutrino Experiment (LBNE) will utilize a beamline facility located at Fermilab to carry out a compelling research program in neutrino physics. The facility will aim a wide band beam of neutrinos toward a detector placed at the Sanford Underground Research Facility in South Dakota, about 1,300 km away. The main elements of the facility are a primary proton beamline and a neutrino beamline. The primary proton beam (60-120 GeV) will be extracted from the MI-10 section of Fermilab’s Main Injector. Neutrinos are produced after the protons hit a solid target and produce mesons which are sign selected and subsequently focused by a set of magnetic horns into a 204 m long decay pipe where they decay mostly into muons and neutrinos. The parameters of the facility were determined taking into account the physics goals, spacial and radiological constraints, and the experience gained by operating the NuMI facility at Fermilab. The initial beam power is expected to be ~1.2 MW; however, the facility is designed to be upgradeable for 2.3 MW operation. We discuss here the status of the design and the associated challenges.

43 PARTICLE ACCELERATORS↗

Axions: From magnetars and neutron star mergers to beam dumps and BECs

We review topics in searches for axion-like-particles (ALPs), covering material that is complementary to other recent reviews. The first half of our review covers ALPs in the extreme environments of neutron star cores, the magnetospheres of highly magnetized neutron stars (magnetars), and in neutron star mergers. The focus is on possible signals of ALPs in the photon spectrum of neutron stars and gravitational wave/electromagnetic signals from neutron star mergers. We then review recent developments in laboratory-produced ALP searches, focusing mainly on accelerator-based facilities including beam-dump type experiments and collider experiments. We provide a general-purpose discussion of the ALP search pipeline from production to detection, in steps, and our discussion is straightforwardly applicable to most beam-dump type and reactor experiments. We end with a selective look at the rapidly developing field of ultralight dark matter, specifically the formation of Bose–Einstein Condensates (BECs). We review the properties of BECs of ultralight dark matter and bridge these properties with developments in numerical simulations, and ultimately with their impact on experimental searches.

Astronomy & Astrophysics↗

Spin Asymmetries on Nucleon Experiment at Jefferson Lab

The Spin Asymmetries of the Nucleon Experiment (SANE) of Jefferson Lab is a comprehensive measurement of double spin asymmetries of the proton for both parallel and almost perpendicular spin configurations of the proton spin and the electron beam polarization directions. The experiment will provide both spin structure functions, g{sub 2} and g{sub 1} and spin observable A{sub 2} and A{sub 1} of the proton over Q{sup 2} region from 2.5 to 6.5 GeV{sup 2}/c{sup 2} and Bjorken x region of 0.3 to 0.8. Using the polarized electron beam of Thomas Jefferson National Accelerator Facility and the polarized frozen NH{sub 3} target, the data were taken early 2009 in Hall C of Jefferson Lab. Scattered electrons from the inclusive reaction were detected by the Big Electron Telescope Array (BETA), a new non-magnetic detector with a large acceptance of 194 msr. The current analysis effort is focused on the proton spin structure functions g{sub 2} and g{sub 1}. Physics motivations with the experimental methods will be presented with an overview of the current status of the data analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nanocluster building blocks of artificial square spin ice: Stray-field studies of thermal dynamics

We present measurements of the thermal dynamics of a Co-based single building block of an artificial square spin ice fabricated by focused electron-beam-induced deposition. We employ micro-Hall magnetometry, an ultra-sensitive tool to study the stray field emanating from magnetic nanostructures, as a new technique to access the dynamical properties during the magnetization reversal of the spin-ice nanocluster. The obtained hysteresis loop exhibits distinct steps, displaying a reduction of their “coercive field” with increasing temperature. Therefore, thermally unstable states could be repetitively prepared by relatively simple temperature and field protocols allowing one to investigate the statistics of their switching behavior within experimentally accessible timescales. For a selected switching event, we find a strong reduction of the so-prepared states' “survival time” with increasing temperature and magnetic field. Besides the possibility to control the lifetime of selected switching events at will, we find evidence for a more complex behavior caused by the special spin ice arrangement of the macrospins, i.e., that the magnetic reversal statistically follows distinct “paths” most likely driven by thermal perturbation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New Methods of Particle Collimation in Colliders

The collimation system is an essential part of the design of any high-power accelerator. Its functions include protection of components from accidental and intentional energy deposition, reduction of backgrounds, and beam diagnostics. Conventional multi-stage systems based on scatterers and absorbers offer robust shielding and efficient collection of losses. Two complementary concepts have been proposed to address some of the limitations of conventional systems: channeling and volume reflection in bent crystals and collimation with hollow electron beams. The main focus of this paper is the hollow electron beam collimator, a novel concept based on the interaction of the circulating beam with a 5-keV, magnetically confined, pulsed hollow electron beam in a 2-m-long section of the ring. The electrons enclose the circulating beam, kicking halo particles transversely and leaving the beam core unperturbed. By acting as a tunable diffusion enhancer and not as a hard aperture limitation, the hollow electron beam collimator extends conventional collimation systems beyond the intensity limits imposed by tolerable losses. The concept was tested experimentally at the Fermilab Tevatron proton-antiproton collider. Results on the collimation of 980-GeV antiprotons are presented, together with prospects for the future.

43 PARTICLE ACCELERATORS↗

New Methods of Particle Collimation in Colliders

The collimation system is an essential part of the design of any high-power accelerator. Its functions include protection of components from accidental and intentional energy deposition, reduction of backgrounds, and beam diagnostics. Conventional multi-stage systems based on scatterers and absorbers offer robust shielding and efficient collection of losses. Two complementary concepts have been proposed to address some of the limitations of conventional systems: channeling and volume reflection in bent crystals and collimation with hollow electron beams. The main focus of this paper is the hollow electron beam collimator, a novel concept based on the interaction of the circulating beam with a 5-keV, magnetically confined, pulsed hollow electron beam in a 2-m-long section of the ring. The electrons enclose the circulating beam, kicking halo particles transversely and leaving the beam core unperturbed. By acting as tunable diffusion enhancer and not as a hard aperture limitation, the hollow electron beam collimator extends conventional collimation systems beyond the intensity limits imposed by tolerable losses. The concept was tested experimentally at the Fermilab Tevatron proton-antiproton collider. Results on the collimation of 980-GeV antiprotons are presented, together with prospects for the future.

43 PARTICLE ACCELERATORS↗

3D imaging of magnetic domains in Nd 2 Fe 14 B using scanning hard X-ray nanotomography

Nanoscale structural and electronic heterogeneities are prevalent in condensed matter physics. Investigating these heterogeneities in 3D has become an important task for understanding material properties. To provide a tool to unravel the connection between nanoscale heterogeneity and macroscopic emergent properties in magnetic materials, scanning transmission X-ray microscopy (STXM) is combined with X-ray magnetic circular dichroism. A vector tomography algorithm has been developed to reconstruct the full 3D magnetic vector field without any prior noise assumptions or knowledge about the sample. Two tomographic scans around the vertical axis are acquired on single-crystalline Nd 2 Fe 14 B pillars tilted at two different angles, with 2D STXM projections recorded using a focused 120 nm X-ray beam with left and right circular polarization. Image alignment and iterative registration have been implemented based on the 2D STXM projections for the two tilts. Dichroic projections obtained from difference images are used for the tomographic reconstruction to obtain the 3D magnetization distribution at the nanoscale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Injection/Extraction Studies In The Non-scaling FFAG For The Neutrino Factory

The Neutrino Factory is under intensive study in the framework of the International Design Study for future precision neutrino oscillation physics. According to the current baseline the major part of muon acceleration is foreseen to take part in the non-scaling fixed field alternating gradient (NS-FFAG) ring. The NS-FFAG lattice design was recently modified to accommodate long straight sections necessary for the injection/extraction systems. The length of the long drift was optimized minimizing the necessary septum field, which according to present studies needs to be below 2 T. The injection/extraction schemes allowing to reuse the kickers for both signs of muons are presented. The design of the kicker system based on current technology is discussed. The preliminary design of a septum magnet focused on minimization of the stray field leakage is studied.

43 PARTICLE ACCELERATORS↗

Optimized cobalt nanowires for domain wall manipulation imaged by in situ Lorentz microscopy

Direct observation of domain wall (DW) nucleation and propagation in focused electron beam induced deposited Co nanowires as a function of their dimensions was carried out by Lorentz microscopy (LTEM) upon in situ application of magnetic field. Optimal dimensions favoring the unambiguous DW nucleation/propagation required for applications were found in 500-nm-wide and 13-nm-thick Co nanowires, with a maximum nucleation field and the largest gap between nucleation and propagation fields. The internal DW structures were resolved using the transport-of-intensity equation formalism in LTEM images and showed that the optimal nanowire dimensions correspond to the crossover between the nucleation of transverse and vortex walls.

77 NANOSCIENCE AND NANOTECHNOLOGY↗