Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam polarization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A Near Perfect Spin Balance (Measurement in Chaos)

The stringent spin balance requirements arise from the predecessor of SSMIS, the SSMI. The SSMI sensor spinning portion weighed only 85 pounds and contained 7 channels of radiometric data. The Aerospace Corporation recommended to pass on the same requirements from the smaller SSMI to our larger SSMIS (with slight change for increased weight). The SSMIS spinning portion will weigh about 155 pounds and contain 24 channels of radiometeric data. The SSMIS, on orbit, spins a CCW direction at 31.6 RPM its own drive motor. The packaging of this SSMIS is unique, as it combines three sensor into one unit. This combination allows for concurrently reading data in one beam. The unit will have a polar orbit about 500 miles above the earths surface. One of the primary influences for our receipt of the follow-on contract for the next generation sensor, was the ability to package 24 channels of radiometeric data into about the some volume as its predecessor. The data from SSMIS will be used to measure the following: (1) Ocean surface wind speed, (2) Rain over land an ocean, (3) Cloud water over Ocean, (4) Soil moisture, (5) Ice Concentration, (6) Ice age, (7) Ice Edge and snow edge, (8) Water vapor over Ocean, (9) Surface type, (10) Snow water content, (11) Land surface Temperature, (12) Cloud amount over ocean.

Luntz, R. A.↗

On the Antenna Pattern of Orbitting Interferometer

We consider the response of an interferometer moving with respect to a fixed reference frame, and derive a simple expression for the beam-pattern factors and the polarization-averaged antenna power pattern...Then, we consider a class of motions where the detector's plane is constrained to move on the surface of a cone of constant aperture; at the same time, the two arms are rotating around a vertical axis...In addition, we consider the case of an Earth-based interferometer...Finally, we discuss LISA's response to circularly polarized sinusoidal waves, coming from a few known binary systems in our Galaxy.

interferometer interferometry antenna motions LISA↗

Scanning Miniature Microscopes without Lenses

The figure schematically depicts some alternative designs of proposed compact, lightweight optoelectronic microscopes that would contain no lenses and would generate magnified video images of specimens. Microscopes of this type were described previously in Miniature Microscope Without Lenses (NPO - 20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43 and Reflective Variants of Miniature Microscope Without Lenses (NPO 20610), NASA Tech Briefs, Vol. 26, No. 9 (September 1999), page 6a. To recapitulate: In the design and construction of a microscope of this type, the focusing optics of a conventional microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. Elimination of focusing optics reduces the size and weight of the instrument and eliminates the need for the time-consuming focusing operation. The microscopes described in the cited prior articles contained two-dimensional CCDs registered with two-dimensional arrays of microchannels and, as such, were designed to produce full two-dimensional images, without need for scanning. The microscopes of the present proposal would contain one-dimensional (line image) CCDs registered with linear arrays of microchannels. In the operation of such a microscope, one would scan a specimen along a line perpendicular to the array axis (in other words, one would scan in pushbroom fashion). One could then synthesize a full two-dimensional image of the specimen from the line-image data acquired at one-pixel increments of position along the scan. In one of the proposed microscopes, a beam of unpolarized light for illuminating the specimen would enter from the side. This light would be reflected down onto the specimen by a nonpolarizing beam splitter attached to the microchannels at their lower ends. A portion of the light incident on the specimen would be reflected upward, through the beam splitter and along the microchannels, to form an image on the CCD. If the nonpolarizing beam splitter were replaced by a polarizing one, then the specimen would be illuminated by s-polarized light. Upon reflection from the specimen, some of the s-polarized light would become p-polarized. Only the p-polarized light would contribute to the image on the CCD; in other words, the image would contain information on the polarization rotating characteristic of the specimen.

Wang, Yu↗

Open-Access, Low-Magnetic-Field MRI System for Lung Research

An open-access magnetic resonance imaging (MRI) system is being developed for use in research on orientational/gravitational effects on lung physiology and function. The open-access geometry enables study of human subjects in diverse orientations. This system operates at a magnetic flux density, considerably smaller than the flux densities of typical other MRI systems, that can be generated by resistive electromagnet coils (instead of the more-expensive superconducting coils of the other systems). The human subject inhales air containing He-3 or Xe-129 atoms, the nuclear spins of which have been polarized by use of a laser beam to obtain a magnetic resonance that enables high-resolution gas space imaging at the low applied magnetic field. The system includes a bi-planar, constant-current, four-coil electromagnet assembly and associated electronic circuitry to apply a static magnetic field of 6.5 mT throughout the lung volume; planar coils and associated circuitry to apply a pulsed magnetic-field-gradient for each spatial dimension; a single, detachable radio-frequency coil and associated circuitry for inducing and detecting MRI signals; a table for supporting a horizontal subject; and electromagnetic shielding surrounding the electromagnet coils.

Mair, Ross W.↗

Overview of SIM external calibration

Like all astrometric instruments, the Space Interferometry Mission (SIM) suffers from field-dependent errors requiring calibration. Diffraction effects in the delay line, polarization rotations on comer cubes, and beam walk across imperfect optics, all contribute to field-distortion that is significantly larger than is acceptable. The bulk of the systematic error is linear across the field - that is, it results in a magnification error. We show that the linear terms are inconsequential to the performance of SIM because they are inseparable from baseline length and orientation errors. One approach to calibrating the higher-order terms is to perform external' calibration; that is, SIM periodically makes differential measurements of a field of bright stars whose positions are not precisely known. We describe the requirements and constraints on the external calibration process and lay the groundwork for a specific procedure detailed in accompanying papers.

Space↗

High resolution Fourier interferometer-spectrophotopolarimeter

A high-resolution Fourier interferometer-spectrophotopolarimeter is provided using a single linear polarizer-analyzer the transmission axis azimuth of which is positioned successively in the three orientations of 0 deg, 45 deg, and 90 deg, in front of a detector; four flat mirrors, three of which are switchable to either of two positions to direct an incoming beam from an interferometer to the polarizer-analyzer around a sample cell transmitted through a medium in a cell and reflected by medium in the cell; and four fixed focussing lenses, all located in a sample chamber attached at the exit side of the interferometer. This arrangement can provide the distribution of energy and complete polarization state across the spectrum of the reference light entering from the interferometer; the same light after a fixed-angle reflection from the sample cell containing a medium to be analyzed; and the same light after direct transmission through the same sample cell, with the spectral resolution provided by the interferometer.

Fymat, A. L.↗

High-resolution Laboratory Measurements of K-shell X-ray Line Polarization and Excitation Cross Sections in Helium-like S XV Ions

We report measurements of electron-impact excitation cross sections for the strong K-shell n = 2 -> 1 transitions in S XV, using the LLNL EBIT-I electron beam ion trap, two crystal spectrometers, and the EBIT Calorimeter Spectrometer. The cross sections are determined by direct normalization to the well-known cross sections of radiative electron capture, measured simultaneously. Using contemporaneous polarization measurements with the two crystal spectrometers, whose dispersion planes are oriented parallel and perpendicular to the electron beam direction, the polarization of the direct excitation line emission is determined, and in turn the isotropic total cross sections are extracted. We further experimentally investigate various line-formation mechanisms, finding that radiative cascades and collisional inner-shell ionization dominate the degree of linear polarization and total line emission cross sections of the forbidden line, z.

atomic data↗

Polarimetry in X- and Gamma-Ray Astronomy: The Ultimate Dimension

Polarization has been a powerful diagnostic tool in radio, microwave, and visible astronomy, providing details of photonproduction mechanisms on much smaller scales than can bedirectly imaged or deduced from photon intensity and energyalone. While polarimetry at other these wavebands (radio,microwave, and optical) is an established technique, highenergy astrophysics lags far behind in this respect. Yet polarizationanalysis has the potential of revealing many detailsabout the magnetic fields, geometries, and emission mechanismsfound in high energy emitting sources. Deviations fromspherical symmetry and/or the presence of ordered magneticfields give rise to polarized radiation: some examples includeanisotropy in solar flares, the presence of jets in microquasarsand blazars, accretion disks around stellar and massive blackholes, accreting and rotation-powered pulsars, and beams ingamma-ray bursts. In addition, null polarization detectionsfrom gamma-ray bursts at x-ray energies have been usedas a test of fundamental physics by placing limits on the possibleviolation of Lorentz invariance.

Hunter, Stanley D.↗

Electron scattering by highly polar molecules. III - CsCl

Utilizing a crossed electron-beam-molecular-beam scattering geometry, relative values of differential electron scattering cross sections for cesium chloride at 5 and 20 eV electron impact energies and at scattering angles between 10 and 120 deg have been measured. These relative cross sections have been normalized to the cross section at 15 deg scattering angle calculated by the hybrid S-matrix technique. In the angular range between 0 and 10 deg and between 120 and 180 deg extrapolations have been made to obtain integral and momentum transfer cross sections. An energy-loss spectrum is also presented which gives various spectral features lying between the 4 and 10 eV regions in CsCl.

Vuskovic, L.↗

Wideband waveguide polarizer development for SETI

A wideband polarizer for the Deep Space Network (DSN) 34 meter beam waveguide antenna is needed for the Search for Extraterrestrial Intelligence (SETI) project. The results of a computer analysis of a wideband polarizer are presented.

Lee, P.↗

Directivity and spacing for the antenna elements

The optimum design choice for the MST radar antenna was considered. The following factors are required: directivity and gain; beam width and its symmetry; sidelobe levels, near and wide angle; impedance matching; feeder network losses; polarization diversity; steerability; cost effectiveness; and maintainability. The directivity and related beam forming aspects of various antenna elements and directivity aspects when such elements are formed into an array are discussed. Array performance for important variables, in particular, the spacing of the elements is considered.

Koshy, V. K.↗

Gravitational lensing of supernovae by dark matter candidates of mass M greater than about 0.001 solar masses

A review is presented concerning the gravitational lensing of supernovae by intervening condensed objects, including dark matter candidates such as dim stars and black holes. the expansion of the supernova beam within the lens produces characteristic time-dependent amplification and polarization which depend upon the mass of the lens. The effects of the shearing of the beam due to surrounding masses are considered, although the study of these effects is confined to isolated masses whose size is much less than that of the supernova (about 10 to the 15th cm). Equations for the effects of lensing and graphs comparing these effects in different classes of supernovae are compared. It is found that candidates for lensing would be those supernovae at least as bright as their parent galaxy, or above the range of luminosities expected for their spectral class.

Wagoner, Robert V.↗

Shallow-trap-induced positive absorptive two-beam coupling 'gain' and light-induced transparency in nominally undoped barium titanate

The asymmetry of beam coupling with respect to the orientation of the polar axis in a nominally undoped barium titanate crystal is used to determine the electro-optic and absorptive 'gain' in the usual beam-coupling geometry. For small grating wave vectors, the electrooptic coupling vanishes but the absorptive coupling remains finite and positive. Positive absorptive coupling at small grating wave vectors is correlated with the light-induced transparency of the crystal described herein. The intensity and grating wave vector dependence of the electrooptic and absorptive coupling, and the light-induced transparency are consistent with a model incorporating deep and shallow levels.

Garrett, M. H.↗

Polarization of Lyman-Alpha Radiation from Atomic Hydrogen Excited by Electron Impact form Near Threshold to 1800 eV

The polarization of Lyman-a radiation, produced by electron-impact excitation of atomic hydrogen, has been measured over the extended energy range from near threshold to 1800 eV. Measurements were obtained in a crossed-beam experiment using a silica-reflection linear polarization analyzer in tandem with a vacuum-ultraviolet monochromator to isolate the emitted line radiation. Comparison with various theoretical calculations shows that the present experimental results are in good agreement with theory over the entire range of electron-impact energies and, in particular, are in excellent agreement with theoretical convergent-close-coupling (CCC) calculations performed in the present work. Our polarization data are significantly different from the previous experimental measurements of Ott, Kauppila, and Fite.

James, G. K.↗

Polarization of Lyman-(alpha) Radiation from Atomic Hydrogen Excited by Electron Impact from Near-Threshold to 1800eV

The polarization of Lyman-(alpha) radiation, produced by electron impact excitation of atomic hydrogen, has been measured for the first time over the extended energy range from near-threshold to 1800eV. Measurements were obtained in a crossed-beams experiment using a silica-reflection linear polarization analyzer in tandem with a vacuum ultraviolet (VUV) monochromator to isolate the emitted line radiation.

Lyman atomic line radiation Zeeman effect VUV pola↗

Upward electron beams measured by DE-1 - A primary source of dayside region-1 Birkeland currents

Measurements made by the High Altitude Plasma Instrument on DE-1 have shown that intense upward electron beams with energies from about 20 eV to about 200 eV are a common feature of the region just equatorward of the morning-side polar cusp. Computations of the currents carried by these beams and by the precipitating cusp electrons show excellent agreement with the simultaneous DE-1 magnetometer measurements for both upward and downward Birkeland currents. The data indicate that cold ionospheric electrons, which carry the downward region-1 Birkeland currents on the morning side, are accelerated upward by potential drops of a few tens of eV at altitudes of several thousand kilometers. This acceleration process allows spacecraft above those altitudes to measure routinely the charge carriers of both downward and upward current systems.

Burch, J. L.↗

PRELIMINARY JPSS-3 VIIRS POLARIZATION SENSITIVITY AND COMPARISON WITH S-NPP, JPSS-1 AND -2

The Visible-Infrared Imaging Radiometer Suite (VIIRS) was first launched on-board the Suomi National Polar-orbiting Partnership (S-NPP) spacecraft in October of 2011. There have been three subsequent builds of the VIIRS sensor for the Joint Polar Satellite System (JPSS) program with JPSS-1, -2 and -3 having launch dates of November 2017, March 2022 and 2026 respectively. There is also a JPSS-4 VIIRS, that is in hardware integration during 2020, with a launch date of 2031. VIIRS has 22 bands: 7 thermal emissive bands (TEBs), 14 reflective solar bands (RSBs) and a Day Night Band (DNB). Ocean Color/Chlorophyll (OCC) products use calibrated Science Data Records (SDRs) for bands M1-M7(0.412-0.865μm) to compute their ocean chemistry products. These bands require accurate polarization sensitivity characterization to compensate for polarized upwelling Rayleigh scatter and produce accurate OCC Environment Data Products (EDRs). VIIRS polarization sensitivity requirement failures have driven hardware modifications to the bandpass filters and dichroic beam splitter over the program. This paper will discuss the preliminary JPSS-3 polarization results and how these hardware modifications, as the JPSS program progresses, have affected the sensor performance. Comparisons of the polarization sensitivities between sensor builds will be discussed along with the hardware modifications that contributed to their differences.

VIIRS↗