Search NASA⌕ Search

SEARCH · Search NASA

Results for “Body”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Pain Response After Stereotactic Body Radiation Therapy Versus Conventional Radiation Therapy in Patients With Bone Metastases—A Phase 2 Randomized Controlled Trial Within a Prospective Cohort

Pain response after conventional external beam radiation therapy (cRT) in patients with painful bone metastases is observed in 60% to 70% of patients. The aim of the VERTICAL trial was to investigate whether stereotactic body radiation therapy (SBRT) improves pain response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integration of Risk Survival Measures Estimated From Pre- and Posttreatment Computed Tomography Scans Improves Stratification of Patients With Early-Stage Non-small Cell Lung Cancer Treated With Stereotactic Body Radiation Therapy

To predict overall survival of patients receiving stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (ES-NSCLC), we developed a radiomic model that integrates risk of death estimates and changes based on pre- and posttreatment computed tomography (CT) scans. We hypothesize this innovation will improve our ability to stratify patients into various oncologic outcomes with greater accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase I Trial of Stereotactic Body Radiation Therapy Dose Escalation in Pancreatic Cancer

Stereotactic body radiation therapy (SBRT) has demonstrated encouraging local tumor control rates in the treatment of pancreatic cancer, yet we lack prospective clinical trials evaluating dose-escalation strategies among patients treated with 5-fraction SBRT. This phase 1 dose-escalation trial was conducted to determine the maximum tolerated dose of SBRT in patients with pancreatic cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiblock Discriminant Analysis of Integrative 18F-FDG-PET/CT Radiomics for Predicting Circulating Tumor Cells in Early-Stage Non-small Cell Lung Cancer Treated With Stereotactic Body Radiation Therapy

The main objective of the present study was to integrate {sup 18}F-FDG-PET/CT radiomics with multiblock discriminant analysis for predicting circulating tumor cells (CTCs) in early-stage non-small cell lung cancer (ES-NSCLC) treated with stereotactic body radiation therapy (SBRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Potential for Midtreatment Albumin-Bilirubin (ALBI) Score to Individualize Liver Stereotactic Body Radiation Therapy

Our individualized functional response adaptive approach to liver stereotactic body radiation therapy (SBRT) with assessment of indocyanine green (ICG) retention at baseline and midtreatment to detect subclinical changes in liver function, permitting dose adjustment, has decreased toxicity while preserving efficacy. We hypothesized that assessment of the albumin-bilirubin (ALBI) score at baseline and midtreatment would allow for more practical identification of patients at risk for treatment-related toxicity (TRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy With a High Maximum Dose Improves Local Control, Cancer-Specific Death, and Overall Survival in Peripheral Early-Stage Non-Small Cell Lung Cancer

We investigated whether delivery of a high biologically effective dose (BED) to primary tumors affects systemic outcomes of cancer-specific death (CSD) and overall survival (OS) rates after stereotactic body radiation therapy (SBRT) in patients with early-stage non-small cell lung cancer (ES-NSCLC).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Single-Dose Versus Hypofractionated Focused Radiation on Vertebral Body Structure and Biomechanical Integrity: Development of a Rabbit Radiation-Induced Vertebral Compression Fracture Model

Vertebral compression fracture is a common complication of spinal stereotactic body radiation therapy. Development of an in vivo model is crucial to fully understand how focal radiation treatment affects vertebral integrity and biology at various dose fractionation regimens. We present a clinically relevant animal model to analyze the effects of localized, high-dose radiation on vertebral microstructure and mechanical integrity. Using this model, we test the hypothesis that fractionation of radiation dosing can reduce focused radiation therapy's harmful effects on the spine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The lattice parameter – composition relationship of the body centered cubic uranium-niobium alloys

In this paper, in-situ time-of-flight neutron diffraction experiments were performed on uranium-niobium alloy with 6 wt% Nb to study the lattice parameter-composition relationship for the body centered cubic (bcc) alloys. Based on lattice-parameter measurements of Nb-supersaturated γs phase over the range of 450 – 790 °C, an improved Vegard's-type relationship was established for determination of Nb concentrations at elevated temperatures. Neutron diffraction data were also collected as a function of aging time over the 450 - 600 °C range when γs phase decomposed isothermally into the mixture of orthorhombic α-U and Nb-rich bcc phase, as well as at room-temperature on the alloys aged ex-situ at 500 °C up to five years. From these measurements, the average Nb concentrations in the bcc phase were determined based on the Rietveld refinements of weight fraction and mass conservation relations (lever rule). Over the 15at% – 78at% range of Nb concentrations that correspond to different experimental aging times, the lattice parameters at constant temperatures exhibit a nonlinear S-shaped variation with Nb concentration, and the associated excess volumes of mixing can be described by a subregular solution model of the Redlich–Kister type of polynomial. Over the full range of composition the S-shaped deviation from Vegard's law can be modeled using a combination of an elastic continuum model and a perturbation to the radii of the solute atoms in the solvent, suggesting that electronic interactions between solute and solvent atoms could play an important role in the compositional dependence of lattice parameter for the γ-phase U-Nb alloys. While Vegard's law is a straightforward and reasonably good approximation for the bcc solid solutions in the U-Nb system, the Nb concentrations determined from the weight fraction refinements of diffraction data provide internally consistent, mass-conserving estimates of solute redistribution for the monotectoid reaction.

36 MATERIALS SCIENCE↗

A simple Rice-Ashby ductile–brittle transition temperature (DBTT) model based on dislocation mobility for body-centered cubic complex concentrated alloys

A simple Rice-Ashby type model for ductile–brittle transition temperature (DBTT) of body-centered cubic (bcc) complex concentrated alloys (structures) is presented. The effect of accumulation of dislocation density on DBTT is also analyzed. The model results are compared with experimental yield stress vs. temperature data for four complex concentrated alloys: Nb 45 Ta 25 Ti 15 Hf 15 (NTTH), MoNbTaW, HfNbTaTiZr, NbTiZr and two pure bcc metals, Fe and W. It is shown that the DBTT behavior of these alloys and pure metals are in agreement with the simple ductility model presented in this manuscript. The DBTT model presented in this manuscript along with yield strength models for bcc complex concentrated alloys described in the literature should serve as a useful guide for designing such alloys with good high temperature strength and significant room temperature ductility.

Crack tip processes↗

Intrinsically stretchable neuromorphic devices for on-body processing of health data with artificial intelligence

For leveraging wearable technologies to advance precision medicine, personalized and learning-based analysis of continuously acquired health data is indispensable, for which neuromorphic computing could provide the most efficient implementation of artificial intelligence (AI) data processing. For realizing on-body neuromorphic computing, skin-like stretchability is required, but yet to be combined with the suite of desired neuromorphic metrics, including linear, symmetric weight update, and sufficient state retention, for achieving high computing efficiency. Here, we report an intrinsically stretchable neuromorphic device based on an electrochemical transistor, which provides a large number (>800) of states, linear/symmetric weight update, excellent switching endurance (>100 million), good state retention (>10 4 s), together with high stretchability of 100% strain. Further integration into a prototype array successfully realized the implementation of vector-matrix multiplication even at 100% strain. Finally, we demonstrate the feasibility of implementing AI-based classification of health signals (as exemplified by electrocardiograms) with a high accuracy that is minimally influenced by the stretched state of the neuromorphic hardware. Finally, this work breaks the ground for combining AI data analysis into skin-like wearable electronics for achieving human-integrated/mimetic intelligent systems.

60 APPLIED LIFE SCIENCES↗

Flow reduction of hydrocarbon liquid in silica nanochannel: Insight from many-body dissipative particle dynamics simulations

A modified many-body dissipative particle dynamics (mDPD) model recently developed for realistic mesoscale multiphase flow simulations is rigorously parameterized, calibrated, and applied for elucidating the flow mechanisms of hydrocarbon liquids (i.e., heptane in this work) in amorphous silica cylindrical nanochannels with inner diameters ranging from 4.5 to 22.5 nm. The simulation results suggest the presence of a strong threshold of pressure gradient under which heptane cannot be driven to flow. The threshold for the 4.5 nm diameter pore is 10 to 100 times as high as for the 9–22.5 nm diameter pore, highlighting a remarkable nanoconfinement effect. Fluid viscosity is found to exhibit a shear-thinning phenomenon with intensity to weaken with increasing channel diameter — a phenomenon not observed in nanochannel flow of liquid water and gas in literature. Most remarkably, the radial profiles of average longitudinal flow velocity fitted by the modified Hagen-Poiseuille equation showed a negative slip length (–2.5% to –0.5% relative to the diameter) and a reduction of apparent permeability by 16% to 23%. Furthermore, this finding suggests silica nanochannels tend to deter hydrocarbon flow, a phenomenon that is opposed to the flow enhancement reported in most of the prior nanochannel flow studies in literature.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dynamic response of a freely rotating butterfly valve in the advanced test reactor – dynamic fluid-body interaction modeling

To regulate primary coolant flow in the Advanced Test Reactor (ATR), a butterfly valve was installed between the primary coolant pumps and the reactor core. If the mechanical connection between the valve's disk and its shaft ever fails, the disk will rotate freely. Rapid disk rotation may induce pressure surges that could damage upstream pipes. In the present work, the rotational trajectory and pressure evolution during a disk free-rotation scenario were analyzed via the dynamic fluid-body interaction (DFBI) approach in STAR-CCM+, with the movement of a solid being driven by the forces and moment/torque imposed by its surrounding fluid. Assuming a large initial opening angle, the disk accelerates slowly, but swiftly passes the closed position. As a result of the sudden valve closure, a pressure surge occurs in the upstream pipes, exceeding their maximum allowable pressure. Furthermore, the disk does not stabilize at the closed position but continually oscillates due to the unsteady nature of the coolant flow. Because of the significant and continuous water hammer effect, a fix to the butterfly valve is being implemented to prevent rapid valve closure due to failure at the valve's disk/shaft mechanical connection.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗