Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bricks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Technical Improvements to an Absorbing Supergel for Radiological Decontamination in Tropical Environments

Argonne National Laboratory (Argonne) developed a superabsorbing gel-based process (SuperGel) for the decontamination of cesium from concrete and other porous building materials. Here, we report on results that tested the gel decontamination technology on specific concrete and ceramic formulations from a coastal city in Southeast Asia, which may differ significantly from some U.S. sources. Results are given for the evaluation of americium and cesium sequestering agents that are commercially available at a reasonable cost; the evaluation of a new SuperGel formulation that combines the decontamination properties of cesium and americium; the variation of the contamination concentration to determine the effects on the decontamination factors with concrete, tile, and brick samples; and pilot-scale testing (0.02–0.09 m2 or 6–12 in. square coupons).

54 ENVIRONMENTAL SCIENCES↗

Advanced Scientific Computing Research Exascale Requirements Review. An Office of Science review sponsored by Advanced Scientific Computing Research, September 27-29, 2016, Rockville, Maryland

The widespread use of computing in the American economy would not be possible without a thoughtful, exploratory research and development (R&D) community pushing the performance edge of operating systems, computer languages, and software libraries. These are the tools and building blocks — the hammers, chisels, bricks, and mortar — of the smartphone, the cloud, and the computing services on which we rely. Engineers and scientists need ever-more specialized computing tools to discover new material properties for manufacturing, make energy generation safer and more efficient, and provide insight into the fundamentals of the universe, for example. The research division of the U.S. Department of Energy’s (DOE’s) Office of Advanced Scientific Computing and Research (ASCR Research) ensures that these tools and building blocks are being developed and honed to meet the extreme needs of modern science. See also http://exascaleage.org/ascr/ for additional information.

97 MATHEMATICS AND COMPUTING↗

Field-Distortion Air-Insulated Switches for Next-Generation Pulsed-Power Accelerators

We have developed two advanced designs of a field-distortion air-insulated spark-gap switch that reduce the size of a linear-transformer-driver (LTD) brick. Both designs operate at 200 kV and a peak current of ~50 kA. At these parameters, both achieve a jitter of less than 2 ns and a prefire rate of ~0.1% over 5000 shots. We have reduced the number of switch parts and assembly steps, which has resulted in a more uniform, design-driven assembly process. We will characterize the performance of tungsten-copper and graphite electrodes, and two different electrode geometries. The new switch designs will substantially improve the electrical and operational performance of next-generation pulsed-power accelerators.

36 MATERIALS SCIENCE↗

Light Water Reactor Sustainability Program Interrogation of Alkali-Silica Reaction Degraded Concrete Samples using Acoustic and Thermal Techniques to Support Development of a Structural Health Monitoring Framework

Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Health monitoring of concrete structures is performed to understand the current condition of a structure based on heterogeneous measurements and then produce high-confidence actionable information regarding structural integrity. This information can then be used to support operational and maintenance decisions. The proposed diagnosis and prognosis framework consists of four elements: health monitoring, data analytics, uncertainty quantification, and prognosis. The objectives of this ongoing research project focuses on health monitoring and data analytics of concrete slab cast, which is cured using four pockets of reactive aggregates: pure silica, wells, placitas, and spratt. A controlled concrete slab with four aggregates is cast at Vanderbilt University in representative conditions to accelerate degradation due to alkali-silica reaction (ASR). Four nondestructive evaluation (NDE) techniques (thermography, mechanical deformation measurements, nonlinear impact resonance-acoustic spectroscopy, and vibro-acoustic modulation) are used to examine the degraded concrete slab. Heterogeneous data from these techniques are analyzed for assessing ASRrelated degradation in concrete samples. In addition, this report discusses thermography assessment of three cement bricks cured under different conditions to accelerate ASR-related degradation. The application of the digital image correlation technique to study ASR-related degradation on a large concrete sample at the University of Tennessee Knoxville is discussed and initial observations are presented in this report. The results from the data analysis of the NDE techniques on concrete slab cured at Vanderbilt University are discussed in detail in this report. The major outcome of the analysis suggests that the nonlinear impact resonance acoustic spectroscopy is able to detect potential degradation in a concrete slab but is unable to locate or isolate the degradation. Alternatively, the vibro-acoustic technique is able to detect degradation and locate the damage in the concrete slab cast. The outcomes supports development of a structural health monitoring framework.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulations of the Large Surface Explosion Coupling Experiment (LSECE)

The Large Surface Explosion Coupling Experiment (LSECE) project will include two surface energetic events (chemical explosions) conducted as close as possible to ground zero (GZ) of the Source Physics Experiment (SPE) Phase II Dry Alluvium (DAG) site in Yucca Flat at the Nevada National Security Site (NNSS). Seismic and acoustic data from these events will complement DAG buried source data and improve interpretation of speed-of-sound signals from explosions for national security programs. A satellite image of the region near GZ along with some of the recording stations that we will use for the far- eld simulation is shown in Figure 1. The working design of the HE package is shown in the Figure 2 and is roughly a cube of C-4 bricks.

58 GEOSCIENCES↗

A comprehensive final summary of the MCNP calculations performed concerning the UW 137 Cs release event

This document combines and supersedes earlier reports (e.g. LA-UR-19-32358 and LA-UR-20- 22216) that discussed MCNP-calculated conversion factors (count rate per unit activity per unit area) for collimated 2”x2” NaI detectors (Ludlum model 44-10 and Thermo model SPA3) in contact with various surfaces of interest to the University of Washington 137 Cs release event. These surfaces include: Exterior surface of round and rectangular ducts, Exterior surface of outdoor brick work, Exterior surface of cast iron pipes, Exterior surface of an O 2 filter assembly For each surface, the calculated conversion factors allowed inferences on 137 Cs activity on interior surfaces based on exterior contact measurements of the 662 keV photopeak count rate. The MCNP calculations included the effect of attached collimators (i.e. either a Pb/Sb-based Ludlum or a W-based “Rees” model) on detector response. As a consequence, the conversion factors only apply to the appropriate collimated 2”x2” NaI detector operated in pulse height analysis (PHA) mode. Other assumptions affecting the calculations and valid application of the conversion factors will be outlined below.

54 ENVIRONMENTAL SCIENCES↗

Chicago Pile-1 paved the way for nuclear science and a lab in Los Alamos First self-sustaining nuclear chain reaction was nearly 80 years ago

On a bitter-cold winter day, 43 scientists gathered at an abandoned squash court at the University of Chicago where they would ultimately enable a secret lab in Los Alamos to change the world just years later. It was December 2, 1942. The group, led by Italian physicist and Nobel laureate Enrico Fermi, stacked graphite bricks, piling 57 layers that totaled more than 770,000 pounds. Later named Chicago Pile-1, their goal was to create the world’s first self-sustaining, controlled nuclear chain reaction. Inside the approximately 20-feet-tall pile were smaller blocks of uranium and control rods that, when removed, would cause the reaction to go critical – meaning create a nuclear chain reaction. It was roughly $1 million worth of materials, equivalent to nearly $16 million today, and a concept that a nuclear chain reaction would allow the weaponization of the atom. “Its success would be the crucial proof needed to know it would be possible to create an atomic bomb,” said LANL Historian Roger Meade (C-NR). “This was the precursor to the Lab we have today, nearly 80 years later.”

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a FHR

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to include non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR technologies under Strategy 2 of the NRC's near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enhancements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform fluoride-salt-cooled high-temperature reactor (FHR) safety evaluations. The generic plant model is based on publicly-available FHR design information. For plant aspects (e.g., reactor building leak rate and details of the cover-gas system) that are not described in the FHR references, the analysts made assumptions needed to construct a MELCOR full-plant model. The FHR model uses a TRi-structural ISOtropic (TRISO)-particle fuel pebble-bed reactor with a primary system rejecting heat to two coiled tube air heat ex changers. Three passive direct reactor auxiliary cooling systems provide heat removal to supplement or replace the emergency secondary system heat removal during accident conditions. Surrounding the reactor vessel is a low volume reactor cavity that insulates the reactor with fire bricks and thick concrete walls. A refractory reactor liner system provides water cooling to reduce the concrete wall temperatures. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing reactivity control, the primary system decay heat removal and also a piping leak of the line to the coolant drain tank.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

US Fallout Shelter

Being indoors (sheltering) reduces radiation exposures resulting from nuclear fallout or a power-plant accident. However, most US building types, particularly non-residential buildings, lack quantitative estimates. We provide here a high-level modeling analysis of modern US building protection based on a novel radiation protection building attribute taxonomy, a new building protection model, compilation of prior experimental results, and nationally representative building survey data. This approach provides a consistent, quantitative understanding of US building protection and, when combined with the distribution of people among different buildings, can assist in selecting emergency response strategies. We find that indoor radiation protection varies by orders of magnitude. Most people in non-residential buildings are adequately protected, particularly below ground or in the building center. Residential buildings are less protective and those with lighter weight walls lack adequate, above ground protection. This work also highlights key areas where further investigation will improve the current results. These include the improving the understanding of residential basement protection, additional experimental data on non-residential buildings (particularly schools and industrial buildings), and the frequency of brick veneer and stucco exterior residential buildings.

61 RADIATION PROTECTION AND DOSIMETRY↗

Defining the Prototype Convenience Store Building Characteristics

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 30 prototype building models (20 different building types), which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). This report documents the building and system characteristics of the prototype convenience store building model. Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype convenience store building characteristics, and a one-story, 3,000 ft 2 building was considered as the prototype convenience store to represent an average-sized convenience store in the United States. The Oak Ridge National Laboratory team defined the operational hours of the convenience store as 17 hours per day. The types of exterior walls, roof, and floor were defined as brick wall, metal surfacing roof, and slab-on-grade floor, respectively. Double glazing was selected, and the window-towall ratio was set as 15% on the front side. For the system part, packaged system and centralized water heater were selected for the space heating and cooling system and water heater system, respectively. In terms of the refrigerator system, the number of refrigerators and freezers were determined as eight closed cases and two walk-in units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Eco-Friendly High-Performance Carbon Building Material Development from Coal

The development of eco-friendly high-performance building materials based on coal-derived materials is greatly beneficial for promoting environmental sustainability and the coal industry. This project focused on advancing technology to create innovative and scalable construction materials from two domestic sources: (1) coal-derived pyrolyzed char (PC), and (2) solvent-extracted coal deposit, extracts, and residue (CDER). It aimed to simultaneously develop and produce two types of coal-derived building products: (1) char-based concrete bricks (CCB) for wall construction in buildings, and (2) carbon-based structural units (CSU) intended as alternatives to traditional wood, concrete, or steel framing structures. The project team has successfully developed methods for manufacturing CCB samples. Extensive experiments were conducted to assess various manufacturing techniques for these samples. This included measuring their physical properties such as thermal conductivity (ranging from 0.26 to 0.38 W/mK) and bulk density (ranging from 0.85 to 1.15 g/cm 3 ), along with their mechanical properties (e.g., compressive strength ranging from 14 to 16 MPa at 28 days) for samples with a PC composition of 70%. Quality assurance and quality control tests, focusing on density and compressive strength, were also performed on samples selected randomly from pilot-scale production, and cured for a long term (over three months). The average long-term compressive strength of two randomly selected CCB samples was measured as 15.1 MPa, which was higher than the required target strength of 14 MPa. This indicates that the manufactured CCB samples from the preliminary pilot scale production run have good quality control and long-term strength performance.

01 COAL, LIGNITE, AND PEAT↗

Oxide Semiconductor Sensors for Monitoring Advanced Energy Conversion and Manufacturing Processes at High Temperature

To optimize the operation and functionality of high temperature systems such as slagging gasifiers, coal boilers and glass/steel smelters, it is important to monitor temperature, corrosion and erosion of the refractory used in such systems. Both thermocouple and failure sensors (and arrays of these) would be useful to monitor the health of any refractory or coatings in these systems. Many of such type of sensors are installed into the systems through open access ports within the refractory; however, there are some disadvantages of this approach where corrosive/erosive gas and molten materials can penetrate and compromise the system. The current work presents the development and performance of refractory with embedded high temperature sensors such as thermocouples, thermistors, and various spallation/crack monitoring sensors, which may be used within a variety of refractory brick in different high temperature processes and applications. The objective of our work is to develop high-temperature sensors composed of electroceramic materials that are chemically stable at high temperatures (750°-1500°C) and high pressures (up to 1000 psi) that can be used in monitoring temperature, corrosion and erosion process in refractory used in high energy systems. The high-temperature sensors investigated in this work were composed of various oxide composites directly embedded into the refractory oxides. The composites used for this work were synthesized by a mixed-oxide route. Metal oxides were inserted within a matrix material composed of refractory oxides (Al2O3, ZrO2, etc.). The physical and electrical properties were specifically manipulated by altering the level of percolation of the conductive species (metal oxides) within the refractory constituent (refractory oxide). An example of one of these embedded sensors consisted of an electroceramic-based thermocouple fabricated with two separate oxide composite compositions which were patterned to produce a couple within the interior of a refractory matrix. The thermocouple successfully displayed thermoelectric voltage trend (as a function of temperature), and the voltage was 220.0 mV near 1400 °C. In addition, corrosion tests on the refractory embedded sensors were performed. To evaluate corrosion in the refractory was exposed to high-temperature glass compositions over a 90 h period. The penetration of the glass through the refractory could be monitored by both an amperometric and voltametric based sensor. With this experiment, it was demonstrated that the embedded sensor could dynamically monitor the corrosion process, and thus, provide real-time feedback on both temperature and the refractory health.

20 FOSSIL-FUELED POWER PLANTS↗

Alaska's Rural Building Stock: a Validation Study Using ResStock and Field Data

The availability of accurate national data on demographics, building stock, and energy use is vital for modeling residential buildings and evaluating decarbonization strategies. However, rural and Indigenous populations, including those in rural Alaska, are typically underrepresented in these datasets. These communities face unique challenges due to their remote locations, severe weather conditions, and limited access to resources, resulting in high energy burden. This report examines how rural Alaskan communities are underrepresented in the ResStock housing model and highlights the need for improved data to address their unique housing and energy challenges. Thus, this report examines the representation of rural Alaskan communities within the national housing stock model, ResStock. A validation study was conducted, considering ResStock, Field Data and Aerial and 3D-view data collection (A3DDC) datasets. The validation process started by using the down selecting approach on the ResStock building stock dataset. For the purpose of this study, only the rural Alaska Boroughs and Census areas located in ASHRAE IECC Climate Zone 8 were considered to ensure a more accurate and fair comparison with the field data, which was collected in rural areas located in climate zone 8, specifically within the Nome Census area. While ResStock may accurately represent several characteristics of the building stock for rural Alaska, some differences between modeled, field data, and aerial and 3D-view data collection datasets were identified. The following building characteristics have a high impact on modeled energy consumption and demonstrated large differences: Revisit heating setpoints and consider a substantially higher setpoint distribution, it could potentially address "missing loads" if this is the case. Develop and include Toyo heating in future modeling for ResStock and EnergyPlus. Remove natural gas as a water heater fuel type outside of North Slope County. Foundation type updated to have more crawlspaces rather than basements. Infiltration rates need reexamination for a larger distribution toward higher infiltration rates. Include more vinyl and less brick in exterior wall type and revise wall color for greater proportion of light rather than dark color. Roof material revised from majority shingles to majority metal. Update number of occupants to higher number of occupant count. Building orientation represents a higher proportion of south facing buildings rather than relatively equal. The findings suggest that updating ResStock's probability logic could better represent rural Alaskan buildings. ResStock can be utilized to identify the best upgrades or energy efficiency and energy efficiency improvements, helping community leaders in making more informed decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmentally Friendly Use of Carbon Ore for Advanced Building Materials for Homes and Commercial Buildings

Through this effort, X-MAT CCC sought to confirm the utility and commercialization potential of carbon-derived building materials (CDBM) technology licensed from our partner, Semplastics. These CDBM products contain at least 52% coal-derived carbon by mass. Including the binders within the resin, the products contain at least 71% carbon by mass overall, meeting a key criterion for DE-FOA-0002185 – Area of Interest (AOI) 5 – Design Research and Development, Validation, and Fabrication of a Prototype Carbon-Based Building. The Phase II project has resulted in a technology demonstrator prototype structure, a detailed design for a carbon-based building, and updated techno-economic analysis (TEA) including detailed market surveys to show the commercial viability of CDBM products. We pursued the following objectives in Phase II: (1) construction of a partial building shell as a technology demonstrator, (2) testing of CDBM products, individually and in assemblies, (3) demonstration of bonding of CDBM and traditional building materials (TBM) in structural applications, (4) production of a detailed design for a carbon-based building, and (5) an update of the TEA that was performed in Phase I. In Phase II, X-MAT CCC and our industry team performed the development and testing needed to improve the maturity of the technology from a Technology Readiness Level (TRL) of 5 to TRL 6. CDBM have been shown by our partner Semplastics to exhibit a number of high-performance characteristics, including high strength (five times the flexure strength of the best commercial brick, and more than twice the compressive strength of construction-grade concrete block), lower density, improved mechanical durability and abrasion resistance, very high temperature stability, and resistance to chemicals, acids, salts, and water. These properties offer significant improvements over conventional building materials. Phase II built upon the work accomplished in Phase I by performing technical and economic research and development to confirm the viability of CDBM as commercial products in various markets. Acknowledgment: This material is based upon work supported by the Department of Energy under Award Number DE-FE0031985.

01 COAL, LIGNITE, AND PEAT↗

Open Building Operating System: An Open-Source Grid Responsive Control Platform for Buildings

Grid-interactive efficient buildings (GEBs) with flexible loads are a promising method to decarbonize buildings, shift loads during peak hours, and lower energy use and electricity costs. Despite the promising benefits of GEBs, automation systems that manage flexible loads in response to energy prices or other grid signals are still uncommon in small and medium commercial buildings. Recent literature demonstrates such control solutions, but they often rely on custom integrations lacking the tools and drivers needed for scalability. To address these gaps, our team has created a fully open-source software stack capable of integrating heterogeneous flexible building loads and implementing integrated portable control applications called the Open Building Operating System (OpenBOS). The software can be deployed over existing control architecture with a small capital cost. OpenBOS leverages semantic models, which have been the subject of recent investigations to facilitate application portability. The use of semantic data reduces the labor and expense required to deploy and update smart control applications, increasing scalability. In this paper, the semantic modeling schema "Brick" was used, but the proposed approach can also be applied to ASHRAE standard 223P, when released. This paper describes the methodology and software components of OpenBOS and demonstrates its functionality with a rule-based demand flexibility control application configured using a semantic model. This application was tested at a real building in NY that uses a dual-fuel heating system made up of five ductless heat pump mini-splits and a central furnace serving a single zone. The demonstration reduced electricity costs at the site by 27%, demand during a shed event by 49%, and furnace usage by 35%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ferrites Analysis for the AC-Dipole

In this article, it’s presented the AC-Dipole magnet structure and a method to measure and model bricks of ferrite. These are the building blocks of the magnet. Aim of the project is obtaining a model of the magnetic permeability of the chosen material to get satisfying simulation of the AC-Dipole magnet’s behavior and to size power supply and cooling system.

43 PARTICLE ACCELERATORS↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 130: Storage Tanks, Nevada Test Site, Nevada, Revision 0

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 130, Storage Tanks, identified in the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended February 2008). Corrective Action Unit 130 consists of the seven following corrective action sites (CASs) located in Areas 1, 7, 10, 20, 22, and 23 of the Nevada Test Site: • 01-02-01, Underground Storage Tank • 07-02-01, Underground Storage Tanks • 10-02-01, Underground Storage Tank • 20-02-03, Underground Storage Tank • 20-99-05, Tar Residue • 22-02-02, Buried UST Piping • 23-02-07, Underground Storage Tank This plan provides the methodology for field activities needed to gather the necessary information for closing each CAS. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 130 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible recommendation that no further corrective action is necessary. This will be presented in a Closure Report that will be prepared and submitted to the Nevada Division of Environmental Protection (NDEP) for review and approval. The sites will be investigated based on the data quality objectives (DQOs) finalized on April 3, 2008, by representatives of NDEP; U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for each CAS in CAU 130. The DQO process developed for this CAU identified the following expected closure options: (1) investigation and confirmation that no contamination exists above the final action levels, leading to a no further action declaration; (2) characterization of the nature and extent of contamination, leading to closure in place with use restrictions; or (3) clean closure by remediation and verification. The following text summarizes the SAFER activities that will support the closure of CAU 130: • Perform site preparation activities (e.g., utilities clearances, geophysical surveys). • Move or remove and dispose of debris at various CASs, as required. • Collect environmental samples from designated target populations (e.g., stained soil) to confirm or disprove the presence of contaminants of concern (COCs) as necessary to supplement existing information. • If no COCs are present at a CAS, establish no further action as the corrective action. • If COCs exist, collect environmental samples from designated target populations (e.g., clean soil adjacent to contaminated soil) and submit for laboratory analyses to define the extent of COC contamination. • If a COC is present at a CAS, either: - Establish clean closure as the corrective action. The material to be remediated will be removed, disposed of as waste, and verification samples will be collected from remaining soil, or - Establish closure in place as the corrective action and implement the appropriate use restrictions. • Obtain consensus from NDEP that the preferred closure option is sufficient to protect human health and the environment. • Close the underground storage tank(s) and their contents, if any, in accordance with Nevada Administrative Code regulations. • Remove the lead brick(s) found at any CAS in accordance with the Resource Conservation and Recovery Act.

54 ENVIRONMENTAL SCIENCES↗

Wind Energy Management System EMS Integration Project: Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind and solar power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation), and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind/solar forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. To improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. Currently, uncertainties associated with wind and load forecasts, as well as uncertainties associated with random generator outages and unexpected disconnection of supply lines, are not taken into account in power grid operation. Thus, operators have little means to weigh the likelihood and magnitude of upcoming events of power imbalance. In this project, funded by the U.S. Department of Energy (DOE), a framework has been developed for incorporating uncertainties associated with wind and load forecast errors, unpredicted ramps, and forced generation disconnections into the energy management system (EMS) as well as generation dispatch and commitment applications. A new approach to evaluate the uncertainty ranges for the required generation performance envelope including balancing capacity, ramping capability, and ramp duration has been proposed. The approach includes three stages: forecast and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence levels. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis, incorporating all sources of uncertainties of both continuous (wind and load forecast errors) and discrete (forced generator outages and start-up failures) nature. A new method called the “flying brick” technique has been developed to evaluate the look-ahead required generation performance envelope for the worst case scenario within a user-specified confidence level. A self-validation algorithm has been developed to validate the accuracy of the confidence intervals.

24 POWER TRANSMISSION AND DISTRIBUTION↗