Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Energy Codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Annual Energy Savings and Peak Power Reduction Simulated for CCHP Design and Baseline HP in Cold Climate Cities

This report assesses energy savings and peak power reduction of three heat pumps in multiple US cold climate cities and building types. The three heat pumps comprise a baseline heat pump and two high efficiency cold climate heat pumps (CCHP). The DOE/ORNL Heat Pump Design Model was used to simulate the heat pumps and generate performance curves for EnergyPlus building energy simulations. The annual energy simulations were performed over seven cold climates: 1) Minneapolis, MN; 2) Duluth, MN; 3) Fairbanks, AK; 4) Helena, MT; 5) Indianapolis, IN; 6) Peoria, IL and 7) Eagle County, CO. In order to assess impact of residential building types matching different energy codes, we simulated six single-family houses in Indianapolis, IN, including : 1) single-family house having a crawlspace; 2) having a slab foundation; 3) having a heated basement; 4) having an unheated basement; 5) one single-family house having a heated basement matching IECC code of 2009, 6) and one single-family house having a heated basement matching IECC code of 2012. The former 4 houses match the IECC 2006 code.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Codes Don't Always Get Enforced, But Contracts Do: Changing the Procurement Paradigm to Drive Building Energy Performance

New construction could account for more than 25% of the U.S. energy consumption by 2030. Millions of square feet are built every year that will not perform as expected - despite advancing codes, rating systems, super-efficient technologies, and advanced utility programs. With retrofits of these under-performers decades away, savings potential will be lost for years to come. Only the building owner is in the driver's seat to demand - and verify - higher-performing buildings. Yet our current policy and market interventions really target the design team, not the owner. Accelerate Performance, a U.S. Department of Energy funded initiative, is changing the building procurement approach to drive deeper, verified savings in three pilot states: Illinois, Minnesota, and Connecticut. Performance-based procurement ties energy performance to design and contractor team compensation while freeing them to meet energy targets with strategies most familiar to them. The process teases out the creativity of the design and contracting teams to deliver energy performance - without driving up the construction cost. The paper will share early results and lessons learned from new procurement and contract approaches in government, public, and private sector building projects. The paper provides practical guidance for building owners, facilities managers, design, and contractor teams who wish to incorporate effective performance-based procurement for deeper energy savings in their buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Energy Efficiency Design Guide for Tribal Lands

Homeowners and renters on tribal lands have historically faced a disproportionate energy burden compared to the United States as a whole. The Indian Health Service (IHS), which serves these communities, strives to meet aggressive energy performance goals when constructing their residential housing. Challenges common in rural locations can hinder progress toward those goals, such as availability of materials, access to specialized labor, and budget constraints. This guide is for architects and builders who aim to incorporate energy efficiency (EE) into their residential designs. This report presents commercially viable energy efficiency packages for a variety of locations and home inputs to help guide home builders in choosing improvements for energy performance. The intention is to provide a diverse set of packages that can be used during the design phase to achieve energy savings compared to a code minimum building design. By presenting a set of diverse options with similar expected energy savings and life-cycle costs, final decisions can be left up to the building designers who can better determine the appropriate package given local costs, materials, and labor availability. Although this guide was developed for IHS projects, it can be used to help designers and construction professionals better make cost-effective choices when a detailed, project-specific building energy analysis is not possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Energy Calculator for Simple Commercial Buildings

According to the EIA, simple commercial buildings account for 97% of total commercial building stock. However, most simple commercial buildings for example small- to mid-sized offices, retail, schools and warehouses do not benefit from the data-driven decision-making capabilities of whole-building energy modeling. The high cost of custom modeling limits the use of energy modeling of simple buildings for new construction or retrofit measures. Lack of tools providing helpful information on interactive savings estimates creates difficulties in meeting aggressive decarbonization and energy efficiency goals for simple building designers and utility program managers. This paper reviews a beta phase Simple Building Calculator with the ability to generate relatively accurate and interactive modeling results based on a limited but robust set of inputs. It can evaluate whole-building or single measure savings in new or existing buildings, compare measure package choices, or provide simplified performance modeling for energy codes and utility incentives. The tool combines physical (annual whole building prototype simulation) and statistical modeling techniques to predict annual energy performance. It supports a variety of building characteristics for envelope, HVAC, and lighting with parameters ranging from vintage to max tech configurations, as well as support for single-zone and simple multi-zone HVAC systems. The Simple Building Calculator was designed to provide immediate feedback for otherwise computationally intensive tasks like measure comparison, development of multiple measure package combinations, or verification that measures meet efficiency targets—all with the goal of providing a tool for quick annual energy simulation of simple commercial buildings.

Hart, Reid↗

Preserving Envelope Efficiency in Performance Based Code Compliance

The City of Seattle 2012 Energy Code (Seattle 2014), one of the most progressive in the country, is under revision for its 2015 edition. Additionally, city personnel participate in the development of the next generation of the Washington State Energy Code and the International Energy Code. Seattle has pledged carbon neutrality by 2050 including buildings, transportation and other sectors. The United States Department of Energy (DOE), through Pacific Northwest National Laboratory (PNNL) provided technical assistance to Seattle in order to understand the implications of one potential direction for its code development, limiting trade-offs of long-lived building envelope components less stringent than the prescriptive code envelope requirements by using better-than-code but shorter-lived lighting and heating, ventilation, and air-conditioning (HVAC) components through the total building performance modeled energy compliance path. Weaker building envelopes can permanently limit building energy performance even as lighting and HVAC components are upgraded over time, because retrofitting the envelope is less likely and more expensive. Weaker building envelopes may also increase the required size, cost and complexity of HVAC systems and may adversely affect occupant comfort. This report presents the results of this technical assistance. The use of modeled energy code compliance to trade-off envelope components with shorter-lived building components is not unique to Seattle and the lessons and possible solutions described in this report have implications for other jurisdictions and energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Energy Cost Savings from Increased Commercial Energy Code Compliance

An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed office buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.

code compliance↗

Potential Energy Cost Savings from Increased Commercial Energy Code Compliance

An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed office buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.

code compliance, commercial energy code, energy co↗

Municipal Portfolio Performance and Policy Opportunities

A wide range of policy tools are in place to enhance energy efficiency in the built environment. However, the lion’s share of today’s energy savings opportunities have to do with energy consumption in existing buildings currently in operation. Many of the policy tools in play, including energy codes, have little to no effect on these existing buildings. New tools and resources are needed to bring existing buildings up to higher levels of energy performance. This project was focused on building a replicable framework, complete with open-source software tools and resources, to empower cities around the country to significantly enhance the energy performance of their own existing buildings and identify opportunities for future improvements. These issues were addressed through the evaluation of the performance of the municipal building stock and policy environments of four mid-size cities: Eugene, Oregon; Providence, Rhode Island; Grand Rapids, Michigan; and Tacoma, Washington. The project team worked closely with these cities to help city staff lead by example and create actionable, implementation-focused strategic energy plans for their own municipal building portfolios and to evaluate and improve city policies. A major focus throughout has been replicability and knowledge transfer (“teaching them to fish” rather than doing the work for the city).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impacts of the 2009 IECC for Residential Buildings at State Level

This analysis of residential energy code compares the requirements of the 2009 International Energy Conservation Code (IECC) with the residential code - or typical construction practice in the absence of a code - in most states as of June 2009. The results, which include estimated typical energy savings of updating each state's code to the 2009 IECC, are provided in chapters specific to each state. Several states have either not adopted a mandatory energy code or developed their own codes that have minimal or no connection to the IECC. The latter - including California, Florida, Oregon, and Washington - were not included in this analysis because the codes in these states would be difficult to appropriately compare to the 2009 IECC and most of these states have energy offices that have already assessed the IECC on their own.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

40% Whole-House Energy Savings in the Hot-Humid Climate

This guide book is a resource to help builders design and construct highly energy-efficient homes, while addressing building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-humid climate can build homes that achieve whole house energy savings of 40% over the Building America benchmark (the 1993 Model Energy Code) with no added overall costs for consumers.

Best Practices guides↗

Through the Past Decade: How Advanced Energy Design Guides have influenced the Design Industry

Advanced Energy Design Guides (AEDGs) were originally developed intended to provide a simple approach to building professionals seeking energy efficient building designs better than ASHRAE Standard 90.1. Since its first book was released in 2004, the AEDG series provided inspiration for the design industry and were seen by designers as a starting point for buildings that wished to go beyond minimum codes and standards. In addition, U.S. Department of Energy’s successful Commercial Building Partnerships (CBP) program leveraged many of the recommendations from the AEDGs to achieve 50% energy savings over ASHRAE Standard 90.1-2004 for prototypical designs of large commercial entities in the retail, banking and lodging sectors. Low-energy technologies and strategies developed during the CBP process have been applied by commercial partners throughout their national portfolio of buildings. Later, the AEDGs served as the perfect platform for both Standard 90.1 and ASHRAE’s high performance buildings standard, Standard 189.1. What was high performance a few years ago, however, has become minimum code today. Indeed, most of the prescriptive envelope component requirements in ASHRAE Standard 90.1-2013 are values recommended in the 50% AEDGs several years ago. Similarly, AEDG strategies and recommendations have penetrated the lighting and HVAC sections of both Standard 189.1 and Standard 90.1. Finally, as we look to the future of codes and standards, the AEDGs are serving as a blueprint for how minimum code requirements could be expressed. By customizing codes to specific building types, design strategies tailored for individual buildings could be prescribed as minimum code, just like in the AEDGs. This paper describes the impact that AEDGs have had over the last decade on the design industry and how they continue to influence the future of codes and Standards. From design professionals to code officials, everyone in the building industry has been affected by the AEDGs.

Advanced Energy Design Guides↗

Total System Performance Ratio—A Systems Based Approach for Evaluating HVAC System Efficiency

The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing PCM-integrated walls for potential energy savings in U.S. Buildings

Buildings in the United States account for nearly half of total U.S. energy use. The energy used for space conditioning can be reduced by utilizing thermal energy storage, such as phase change materials (PCMs), into building envelopes; however, the energy savings of PCM-integrated building envelopes reported in the literature vary widely. In the absence of established guidelines, thermophysical requirements of an optimal PCM, its method of application into the building envelope, and the corresponding energy savings under various climates remain unknown. Here, we perform an extensive numerical investigation on the integration of PCM into building walls to establish the key conditions required for effective utilization of PCM in reducing heat gains in the cooling season and heat losses in the heating season. We also determine the optimal transition temperature, optimal PCM location in the wall, and the energy-saving potential of the PCM-integrated building walls in five U.S. cities located in different International Energy Conservation Code climate zones. Results show that employing PCMs in building walls does not always lead to an improvement; in fact, incorrect applications of PCMs can substantially increase energy use in the buildings. In the climates we studied, PCMs were found effective in reducing heat gains during the cooling season while mostly ineffective in managing heat losses during heating season. Depending on the climate, optimized PCMs in U.S. building walls can provide reduction in the annual heat gain in the range of 3.5% to 47.2% and the annual heat loss in the range of -2.8% to 8.3%. Future consideration of buildings with substantial solar gains in winter may lead to more reduction in heat losses by PCMs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TASK 2.5.4 DEVELOPMENT OF AN ENERGY SAVINGS CALCULATOR

California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) Building Technologies Program. The Roof Savings Calculator (RSC) tool is designed to help building owners, manufacturers, distributors, contractors and practitioners easily run complex simulations. The latest web technologies and usability design were employed to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned based on the best available statistical evidence and can provide energy and cost savings after the user selects nothing more than the building location. A key goal for the tool is to promote the energy benefits of cool color tile, metal and asphalt shingle roof products and other energy saving systems. The RSC tool focuses on applications for the roof and attic; however, the code conducts a whole building simulation that puts the energy and heat flows of the roof and attic into the perspective of the whole house. An annual simulation runs in about 30 sec. In addition to cool reflective roofs, the RSC tool will simulate high- medium- and low-slope roofs, and has a custom selection for the user whose house has a unique inclination. There is an option for above sheathing ventilation, which is prevalent in tile and stone-coated metal roof assemblies. The tool also accommodates the effects of radiant barriers and low-emittance surfaces in the inclined air space above the sheathing. The practitioner can select to have air-conditioning ducts either in the conditioned space or in the attic. If in the attic, the user can select one of three air leakage options. Option 1 is an inspected duct having 4% leakage and code level of duct insulation; option 2 is a poorly insulated duct having 14% air leakage; and option 3 is a custom leakage rate specified by the user. The practitioner can setup multiple layers of ceiling insulation. AtticSim is benchmarked against the field data acquired for Ft. Irwin located near Barstow, CA, first as a standalone simulation program and then again integrated within the DOE-2.1E program. The standalone benchmark was very useful to determining how well AtticSim replicates the building physics of an attic. The coupled benchmark was useful to verify that the DOE-2.1E/AtticSim code is modeling correctly the dynamic relationship between the attic and the occupied space below, as well as the interactions between the attic and the HVAC system, in particular when the ducts are located in the attic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Opportunity Analysis Based on Standard 90.1-2016

This report summarizes technical analysis conducted by Pacific Northwest National Laboratory (PNNL), assessing expected end-use energy consumption in commercial buildings, based on recent editions of the model energy code for the commercial sector, ANSI/ASHRAE/IES Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Duct Insulation and Sealing Requirements in Commercial Buildings - Code Notes

Duct insulation and sealing, especially insulated supply ducts delivering conditioned air within a building, save energy. The intent of energy-efficiency codes, as related to duct insulation and sealing, is to keep mechanically warmed or cooled air as close to a constant, desired temperature as possible and prevent the conditioned air from escaping the duct system while it is being moved to spaces where it is needed. If reduced heat transfer through insulated ducts is accounted for in the heating, ventilating, and air conditioning (HVAC) load calculations, it may even be possible to reduce the size of HVAC equipment.

Duct systems, thermal envelope, conditioned air, H↗