Search NASA⌕ Search

SEARCH · Search NASA

Results for “CFD modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A Numerical Study on the Energy Performance of a Novel Furnace With Acidic Gas Trap Absorbers

Natural gas furnaces are widely used in US residential and commercial building markets. An important issue for natural gas furnaces is serious corrosion and fouling problems caused by acidic gas, such as SOx. An advanced adsorption technology based on acidic gas trap (AGT) absorbers offers the possibility to remove SOx acidic gas from natural gas furnaces with high efficiency and low cost, thereby enabling the development of condensing furnaces without the use of expensive corrosion resistant materials in the heat exchanger. A three-dimensional (3D) computational fluid dynamics (CFD) model has been developed to evaluate the heat transfer performance of a furnace with AGT absorbers and to compare it with a baseline conventional furnace without the AGT. Moreover, an axisymmetric model has been built focusing on the absorbing process in the AGT. The baseline conventional furnace used for the study is a commercial condensing furnace (Rheem 92% AFUE 84,000 BTU Multi-Position Gas Furnace). This furnace was completely disassembled, and the dimensions of each part were carefully measured and used to build a detailed CFD model. A model representing the new furnace, incorporating the AGT absorbers, was developed by adding the AGT system to the conventional furnace model. For the CFD analysis, a mixture model was employed to characterize the heat and mass transfer during the condensing process in the furnace while considering three components—air, water vapor and liquid water. Condensation takes place in the condensing heat exchanger, where water vapor changes phase to liquid water, and the latent heat is thus used in the furnace for useful heating. The simulation results characterize the energy performance of both the conventional furnace and the novel furnace with AGT absorbers, as well as the reactive processing in the AGT. These results provide insightful guidance for the development of the AGT absorber-based furnace from the perspective of its energy performance and will be used to further optimize this novel furnace design.

Laclair, Tim↗

Experimental and Numerical Investigation of Reduced Gravity Fluid Slosh Dynamics for the Characterization of Cryogenic Launch and Space Vehicle Propellants

As space programs increasingly investigate various options for long duration space missions the accurate prediction of propellant behavior over long periods of time in microgravity environment has become increasingly imperative. This has driven the development of a detailed, physics-based understanding of slosh behavior of cryogenic propellants over a range of conditions and environments that are relevant for rocket and space storage applications. Recent advancements in computational fluid dynamics (CFD) models and hardware capabilities have enabled the modeling of complex fluid behavior in microgravity environment. Historically, launch vehicles with moderate duration upper stage coast periods have contained very limited instrumentation to quantify propellant stratification and boil-off in these environments, thus the ability to benchmark these complex computational models is of great consequence. To benchmark enhanced CFD models, recent work focuses on establishing an extensive experimental database of liquid slosh under a wide range of relevant conditions. In addition, a mass gauging system specifically designed to provide high fidelity measurements for both liquid stratification and liquid/ullage position in a micro-gravity environment has been developed. This pUblication will summarize the various experimental programs established to produce this comprehensive database and unique flight measurement techniques.

Walls, Laurie K.↗

Assessment of Sodium Thermal Stratification Models Utilizing the TSTF Benchmark

As a result of certain transient scenarios, a thermally stratified layer of liquid sodium can develop in the bulk coolant volumes of a sodium-cooled fast reactor (SFR). In addition to the effects a stratification layer has on the temperature of the heat transport system, a stratification layer can also influence the transition to and establishment of natural circulation flow, which plays an important role in passive cooling and the inherent safety of a pool-type SFR. Therefore, the ability to accurately capture thermal stratification phenomena is important when demonstrating the safety basis of a pool-type SFR during transient sequences. The present work assesses various computational models with different fidelities in their ability to predict thermal stratification in the upper plenum of an SFR. Each computational model will be assessed using the data generated at the Thermal Stratification Test Facility (TSTF) located at the University of Wisconsin-Madison. Using measured flow rate and inlet temperature data, the measured temperature distributions of the tests are compared to the predictions of the lumped volume-based models in SAS4A/SASSYS-1, a 1D-based model in SAM, and a 3-D computational fluid dynamics (CFD) model using STAR-CCM+. The relative performance of the various computational methods is assessed with respect to key metrics such as bulk coolant temperature distribution and plenum exit temperature. A total of eight tests are analyzed, covering different combinations of flow rates (3 and 10 GPM) and upper internal structure (UIS) configurations (none, solid, porous, and open) The perfect mixing model of SAS4A/SASSYS-1 provides the highest accuracy when the flow rate is high and there is no UIS in the test vessel, as high flow rate injection promotes thermal mixing of the sodium in the test vessel. For most of the analyzed tests, the stratified volume model of SAS4A/SASSYS-1 is able to predict the delay in the outlet temperature drop and temperature distribution in the test vessel by a small number of layers to represent thermal stratification. However, the stratified volume model can only simulate a maximum of three temperature layers within a volume and when a layer approaches the elevation of the outlet, the predicted outlet temperature can demonstrate rapid, non-physical changes. The 1-D axial mixing model of SAM provides results that agree reasonably well with the measured data in the prediction of the temporal evolution of the outlet temperature with the exception of the case with a high flow rate and no UIS. The SAM 1-D model has a similar level of accuracy to CFD results when it comes to predicting the outlet temperature. CFD shows overall good agreement in predicting the temperature distribution in the test vessel and outlet temperature. As CFD can model the test vessel geometry in detail, it performs well in the cases of complex geometries such as tests that included a UIS and internal flow through the UIS resulting in active mixing of the coolant in the test vessel. Each of the models discussed in the present work has the potential to be useful during the various stages of reactor design, analysis, and licensing. The lumped-volume approach can be applied for fast turnaround safety calculations to obtain overall reactor behavior during transients. The 1-D models provide improved accuracy when stratification is expected for a relatively low increase in the computational cost. The CFD model can be utilized for confirmatory analysis of the 1-D model, when experimental measurements are not available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling Unsteady Cavitation and Dynamic Loads in Turbopumps

A computational fluid dynamics (CFD) model that includes representations of effects of unsteady cavitation and associated dynamic loads has been developed to increase the accuracy of simulations of the performances of turbopumps. Although the model was originally intended to serve as a means of analyzing preliminary designs of turbopumps that supply cryogenic propellant liquids to rocket engines, the model could also be applied to turbopumping of other liquids: this can be considered to have been already demonstrated, in that the validation of the model was performed by comparing results of simulations performed by use of the model with results of sub-scale experiments in water. The need for this or a similar model arises as follows: Cavitation instabilities in a turbopump are generated as inlet pressure drops and vapor cavities grow on inducer blades, eventually becoming unsteady. The unsteady vapor cavities lead to rotation cavitation, in which the cavities detach from the blades and become part of a fluid mass that rotates relative to the inducer, thereby generating a fluctuating load. Other instabilities (e.g., surge instabilities) can couple with cavitation instabilities, thereby compounding the deleterious effects of unsteadiness on other components of the fluid-handling system of which the turbopump is a part and thereby, further, adversely affecting the mechanical integrity and safety of the system. Therefore, an ability to predict cavitation- instability-induced dynamic pressure loads on the blades, the shaft, and other pump parts would be valuable in helping to quantify safe margins of inducer operation and in contributing to understanding of design compromises. Prior CFD models do not afford this ability. Heretofore, the primary parameter used in quantifying cavitation performance of a turbopump inducer has been the critical suction specific speed at which head breakdown occurs. This parameter is a mean quantity calculated on the basis of assumed steady-state operation of the inducer; it does not account for dynamic pressure loads associated with unsteady flow caused by instabilities. Because cavitation instabilities occur well before mean breakdown in inducers, engineers have, until now, found it necessary to use conservative factors of safety when analyzing the results of numerical simulations of flows in turbopumps.

Hosangadi, Ashvin↗

The Importance of Detailed Component Simulations in the Feedsystem Development for a Two-Stage-to Orbit Reusable Launch Vehicle

To meet the requirements for the 2nd Generation Reusable Launch Vehicle (RLV), a unique propulsion feed system concept was identified using crossfeed between the booster and orbiter stages that could reduce the Two-Stage-to-Orbit (TSTO) vehicle weight and development cost by approximately 25%. A Main Propulsion System (MPS) crossfeed water demonstration test program was configured to address all the activities required to reduce the risks for the MPS crossfeed system. A transient, one-dimensional system simulation was developed for the subscale crossfeed water flow tests. To ensure accurate representation of the crossfeed valve's dynamics in the system model, a high-fidelity, three-dimensional, computational fluid-dynamics (CFD) model was employed. The results from the CFD model were used to specify the valve's flow characteristics in the system simulation. This yielded a crossfeed system model that was anchored to the specific valve hardware and achieved good agreement with the measured test data. These results allowed the transient models to be correlated and validated and used for full scale mission predictions. The full scale model simulations indicate crossfeed is ' viable with the system pressure disturbances at the crossfeed transition being less than experienced by the propulsion system during engine start and shutdown transients.

Mazurkivich, Pete↗

Modeling Ullage Dynamics of Tank Pressure Control Experiment during Jet Mixing in Microgravity

A CFD model for simulating the fluid dynamics of the jet induced mixing process is utilized in this paper to model the pressure control portion of the Tank Pressure Control Experiment (TPCE) in microgravity1. The Volume of Fluid (VOF) method is used for modeling the dynamics of the interface during mixing. The simulations were performed at a range of jet Weber numbers from non-penetrating to fully penetrating. Two different initial ullage positions were considered. The computational results for the jet-ullage interaction are compared with still images from the video of the experiment. A qualitative comparison shows that the CFD model was able to capture the main features of the interfacial dynamics, as well as the jet penetration of the ullage.

active control↗

Quantifying transport and electrocatalytic reaction processes in a gastight rotating cylinder electrode reactor via integration of Computational Fluid Dynamics modeling and experiments

Understanding the complexity of the multiple processes of mass, momentum, charge, and heat transport, and how these affect reaction kinetics at the electrode/electrolyte interface is one of the major challenges in the field of energy and catalysis. The rapid and rational scale-up of electrocatalytic systems to industrial scales require a detailed understanding of nonlinear transport-reaction processes, accessible only through the building of multi-physics models that capture with high fidelity the complexity of real-world devices. The gastight rotating cylinder electrode (RCE) reactor is a promising lab-scale tool that can decouple transport from intrinsic kinetics to generate data for first-principle models useful in the design of industrial, electrochemical reactors. Computational Fluid Dynamics (CFD) studies have previously been used to investigate the bulk flow in RCE reactors for simple corrosion and electroplating processes. However, the quantification of changes in local concentration within the viscous layer where catalysis takes place requires capturing the correct flow conditions inside the hydrodynamic boundary layer near the surface of the electrode. Further, this requires simulations with spatial resolution in the nm and μm scale and temporal resolutions between ms and s scales that are similar to the timescales for reactions on the electrode surface. In this study, experimental electrocatalysis is combined with CFD modeling to elucidate and parameterize the hydrodynamics in a gastight RCE reactor. CFD simulations of the electrochemical ferricyanide reduction reaction under mass transport limited conditions are used to evaluate the validity of the CFD model parameters by comparing calculated dimensionless mass transport descriptors to dimensionless correlations obtained experimentally. Justifications for assumptions and details of the simulation methods used in this study are presented to provide a detailed understanding of the effect that each model parameter has on the ability to accurately simulate electrocatalysis in RCE systems. The simulation methodology reported here is a first step towards the development of multi-scale models for the study of transport dependent electrocatalytic processes, such as the electrochemical transformation of CO 2 to fuels and chemicals.

42 ENGINEERING↗

Predicting and analyzing the performance of biomass-burning natural draft rocket cookstoves using computational fluid dynamics

Nearly three billion people in the world today rely on biomass for their cooking needs. Indoor cooking using biomass has been identified as a major cause of respiratory illnesses, resulting in four million premature deaths every year. Improved biomass cookstoves may help mitigate this challenge. This paper presents a two-dimensional axisymmetric steady-state computational fluid dynamics (CFD) model of a biomass burning, natural draft rocket cookstove. The CFD model includes coupled sub-models representing combustion, turbulence, and heat transfer. The model is validated against experimental data and used to predict temperatures and flow inside the cookstove, including the airflow rate through the cookstove and heat transfer to the cookpot. We find that the excess air is typically many times stoichiometric air during standard operating conditions and is sensitive to flow field obstructions. We analyze the effects of geometric and operational features such as the pot support height, secondary air entrainment, cone-deck shape, and baffle placement within the cookstove on the flow, airflow rate, mixing, and stove thermal efficiency. The model shows that secondary air entrainment, though ineffective by itself, increases turbulent mixing when used in conjunction with a central baffle but reduces thermal efficiencies due to enhanced heat transfer to the walls. We find that a lower pot support height decreases the airflow rate and increases thermal efficiency. We model thirty-six cone-deck configurations and find that the cone-deck shape primarily affects the airflow rate through the stove, with more constricted designs leading to higher thermal efficiencies.

09 BIOMASS FUELS↗

Numerical simulation of flow regions in red mud separation thickener's feedwell by analysis of residence-time distribution

The residence-time distribution (RTD) and the compartment model were applied to characterizing the flow regions in red mud separation thickener’s feedwells. Combined with the experimental work, validated mathematical model as well as three-dimensional computational fluid dynamics (CFD) model was established to analyze the flow regions of feedwells on an industrial scale. The concept of RTD, although a well-known method for the characterization of mixing behavior in conventional mixers and reactors, is still a novel measure for the characterization of mixing in feedwells. Numerical simulation results show that the inlet feed rate and the aspect ratio of feedwells are the most critical parameters which affect the RTD of feedwell. Further simulation experiments were then carried out. Under the optimal operation conditions, the volume fraction of dead zone can reduce by10.8% and an increasement of mixing flow volume fraction by 6.5% is also observed. There is an optimum feed inlet rate depending on the feedwell design. The CFD model in conjunction with the RTD analysis then can be used as an effective tool in the design, evaluation and optimization of thickener feedwell in the red mud separation.

42 ENGINEERING↗

Implementation of a High-Fidelity Interface Resolving Method in Nek5000

The development and utilization of computational fluid dynamics (CFD) models for large, high-temperature electric melters in the Waste Treatment and Immobilization Plant (WTP) in eastern Washington State have proven to be valuable for various purposes. These models allow for a better understanding of the physio-chemical processes occurring within the melter vessels and can contribute to improving operational efficiency, throughput, and addressing operational issues related to vitrification. The CFD models employed for these melter vessels incorporate multiphase fluid flow and heat transfer simulations in different regions, including the plenum, cold cap, and molten glass regions. As the tank waste and glass formers are introduced into the melter, a reacting batch layer known as the cold cap forms on top of the molten glass. To enhance the melt rate, forced convection bubblers located at the bottom of the melters generate convection currents that help homogenize the molten glass and provide heat to the cold cap. As the bubbles rise through the highly viscous glass, they adopt a spherical-cap shape [1]. Meanwhile, the conversion of the batch to glass generates significant amounts of gases (such as water vapor, carbon dioxide, sulfur dioxide, and NOx) due to thermal decomposition [2]. These gases become trapped between the cold cap and molten glass, forming a foam layer [3]. For modeling multiphase flow in CFD and heat transfer simulations of waste glass melters at different scales, efforts are underway to augment the capabilities of the Nek5000 [4] and NekRS [5] open-source codes [6]. Nek5000/NekRS is a scalable and efficient spectral element code that has been successfully applied to a wide range of fluid dynamics problems. By leveraging the Nek5000/NekRS software, it becomes possible to model the melter systems more affordably and with lower computational requirements compared to currently utilized commercial CFD software. The specific objectives of this ongoing effort include: 1. Implementation of a level set method in Nek5000/NekRS: The level set method is a numerical technique commonly employed in CFD simulations to track and represent the interface between different phases or materials accurately. By incorporating this method into Nek5000/NekRS, the ability to simulate multiphase flows in waste glass melters at a high level of fidelity can be achieved. 2. Demonstration of capability for air bubbling through molten glass: As part of the development process, a specific case of air bubbling through molten glass will be simulated using the augmented Nek5000/NekRS code. This demonstration aims to showcase the ability of the software to accurately capture and analyze the complex phenomena involved in the multiphase flow within waste glass melters. By achieving these objectives, the improved Nek5000/NekRS code will offer a powerful computational tool for simulating and analyzing waste glass melter systems, enabling better understanding, optimization, and troubleshooting of these vitrification processes. The ability to accurately model and simulate multiphase flows has broad relevance across many industries and scientific domains, and the improved functionality can contribute to advancements in various fields beyond waste glass melter simulations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Device Scale Modeling of Solvent Absorption using MFIX-TFM

Recent climate change is largely attributed to greenhouse gases (e.g., carbon dioxide, methane) and fossil fuels account for a large majority of global CO 2 emissions. That said, fossil fuels will continue to play a significant role in the generation of power for the foreseeable future. The extent to which CO 2 is emitted needs to be reduced, however, carbon capture and sequestration are also necessary actions to tackle climate change. Different approaches exist for CO 2 capture including both post-combustion and pre-combustion technologies, oxy-fuel combustion and/or chemical looping combustion. The focus of this effort is on post-combustion solvent-absorption technology. To apply CO 2 technologies at commercial scale, the availability and maturity and the potential for scalability of that technology need to be considered. Solvent absorption is a proven technology but not at the scale needed by typical power plant. The scale up and down and design of laboratory and commercial packed bed reactors depends heavily on the specific knowledge of two-phase pressure drop, liquid holdup, the wetting efficiency and mass transfer efficiency as a function of operating conditions. Simple scaling rules often fail to provide proper design. Conventional reactor design modeling approaches will generally characterize complex non-ideal flow and mixing patterns using simplified and/or mechanistic flow assumptions. While there are varying levels of complexity used within these approaches, none of these models resolve the local velocity fields. Consequently, they are unable to account for important design factors such as flow maldistribution and channeling from a fundamental perspective. Ideally design would be aided by development of predictive models based on truer representation of the physical and chemical processes that occur at different scales. Computational fluid dynamic (CFD) models are based on multidimensional flow equations with first principle foundations. CFD models can include a more accurate physical description of flow processes and be modified to include more complex behavior. Wetting performance and spatial liquid distribution inside the absorber are recognized as weak areas of knowledge requiring further investigation. CFD tools offer a possible method to investigating such topics and gaining a better understanding of their influence on reactor performance. This report focuses first on describing a hydrodynamic model for countercurrent gas-liquid flow through a packed column and then on the chemistry, heat and mass transfer specific to CO 2 absorption using monoethanolamine (MEA). The indicated model is implemented in MFIX, a CFD open source software package. The user defined functions needed to build this model are described in detail along with the keywords for the corresponding input file. A test case is outlined along with a few results. The example serves to briefly illustrate the developed CFD tool and its potential capability to investigate solvent absorption.

09 BIOMASS FUELS↗

Loci/STREAM Sharp Interface Model Validation of Cryogenic Propellant Tank Self-Pressurization

This paper documents a model validation effort for the prediction of cryogenic propellant tank selfpressurization physics using the Loci/STREAM sharp interface CFD model developed at NASA MSFC. Cryogenic fluid management (CFM) applications for long duration spaceflight missions require accurate modeling of heat transfer and thermodynamics. Therefore, detailed validation of those physics is important to ensure simulation accuracy. In the past, the MSFC Propulsion Fluid Dynamics Branch has validated and used the Loci/STREAM Volume of Fluid (VOF) module extensively for propellant slosh applications, which are dominated by fluid motion. For cases where the interface gas/liquid interface is essentially static, the Loci/STREAM sharp interface was developed for more rapid and efficient CFM analysis. In the present study, Loci/STREAM sharp interface simulations were compared with the NASA K-site self-pressurization experiment of a flight weight, partially full, LH2 tank in normal gravity. This study investigated several parametric effects and made a number of important observations on the performance of the Loci/STREAM sharp interface method: - First, a homogeneous model was derived to verify the CFD model. The homogeneous model assumes both gas and liquid phases are uniform and are at saturation temperature. The predicted pressure rise rates at 3.5 W/m2 and 2.0 W/m2 with a 49% fill level are all lower than the experimental measurement. This is expected due to the observed temperature stratification near the gas-liquid interface during testing. - The k-w and k-e turbulence models predict comparable pressurization rates, which are much lower than the experiment measurement. On the other hand, the pressure values and pressurization rates from both models are almost the same as those of the homogeneous model. The current turbulence model is too diffusive and is not capable of capturing the thermal stratification in the liquid and ullage. - When using the laminar flow model, the pressurization rate is found to be very close to the experimental value when a quasi-steady flow field is allowed to develop by continuously venting the tank prior to pressurization as was done during testing. On the other hand, without initial venting, the rate is not constant. Additionally, the development time to reach a quasi-steady flow field differed from the experiment due to the lack of turbulent mixing away from the gas-liquid interface that is expected in reality. - Using the laminar flow model and appropriate initial conditioning, the pressurization rate is within 15% of the experimental value for 49% fill level at 3.5 W/m 2 and is within 18% for 2.0 W/m 2 heat loading. - Using the laminar flow model and appropriate initial conditioning, the pressurization rate is within 18% of the experimental value for a 29% fill level and within 15% for an 83% fill level.

H. Q. Yang↗

Comment on: The current status of turbulence modeling in CFD and its future prospects

Information is given in viewgraph form on computational fluid dynamics (CFD). Topics covered include the fundamental problem with conventional turbulence modeling, the fundamental problems with the state-of-the-art turbulence modeling approach of 'eddy viscosity', major problems with Reynolds stress equation (RSE) closures, RSE challenges that are probably addressable within the context of Reynolds averaging, RSE challenges which may require theoretical/numerical spectral adjuncts for satisfactory solutions, tools available to aid RSE modeling, and a simplex view of the status of turbulence modeling.

Bushnell, D. M.↗

Scaling of thermal stratification in outlet plena of SFRs with gallium as a surrogate fluid

Due to its high thermal diffusivity, liquid sodium can develop thermally stratified regions in the hot and cold pools of SFRs under certain off normal operating conditions. The temperature gradients in the fluid give rise to mixed convection flow in which flow velocities result both from pressure gradients and from volume forces induced by density gradients. High thermal diffusivity and low momentum diffusivity leads to reduced thermal mixing and enhanced stratification. Thermal stratification, if not looked carefully in the design, can lead to severe consequences in normal operation with forced coolant circulation and during off-normal natural circulation. The resulting hydraulic and thermal loads can cause the failure modes in structures and components critical for reactor safety. Thermal stratification in the SFR pools can lead to thermal fatigue, which can lead to structural and material failure, or pose serious concerns for the reactor safety. In addition to thermo-structural issues, the reactivity changes are significantly impacted due to density or temperature driven movement of liquid sodium. Temperature changes or gradients in the Upper Instrumentation Structures (UIS) of SFRs can lead to thermal contraction, a case that can lead to positive reactivity insertion after core shut-down. The motivation of this work is to design a scaled down experimental facility which can generate high fidelity data for thermal stratification physics to validate 3-dimensional (3D) Computational Fluid Dynamics (CFD) models. These validated CFD codes can be used to improve the 1-dimensional (1D) system level codes such as SAS4A/SASSYS-1 which are currently not capable of simulating thermal stratification accurately. These improvements in 1D system level SAS4A/SASSYS-1 codes can significantly improve the safety analyses and design of SFRs. The GaTE facility outlet plenum model is designed based on physics based similarities. Thermal stratification physics is governed primarily by the Richardson numbers (Ri). The expected low flow rates during off-normal conditions can lead to a high degree of thermal stratification in the outlet plenum with a corresponding Ri = 530. Therefore, the inlet flow velocities and inlet hydraulic diameter for the gallium coolant entering the test vessel are required to achieve same Ri. The design of test vessel in GaTE facility is finalized to a 1/20. scale outlet plenum height of the ABTR. This design of the test facility will allow the decoupling of the thermal stratification physics at low flow rates with the transient natural circulation. In other words, it will enable effective control to study thermal stratification at very low flow rates. Numerical studies are conducted with a 3D CFD code to examine the thermal behavior of the selected test design. Simulation results show that thermal gradients are present only in the vertical or axial direction which are similar to the behavior reported in previous studies on full scale SFR models. Future work will involve the experimental studies using the GaTE facility with the high fidelity instrumentation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity study of coupled chemical-CFD simulations for analyzing aluminum-clad spent nuclear fuel storage in sealed canisters

We report the United States Department of Energy (DOE) manages over 50 Metric Tons Heavy Metal (MTHM) of aluminum-clad spent nuclear fuel. One main source for DOE’s Aluminum-clad spent nuclear fuel (ASNF) inventory is the advanced test reactor (ATR) at the INL site, which makes this fuel of particular interest for storage scenarios. Road-ready and final disposition packaging configurations for the ATR fuel dictates storage within helium-backfilled, sealed DOE standard canisters. The conditions within these sealed canisters for extended (greater than50 year dry) storage is of interest. To further this goal, a three-dimensional (3D) multi-physics computational fluid dynamics (CFD) model is developed of the sealed DOE standard canisters. This 3D CFD model is one-way coupled with bulk gas radiolysis reactions considering sealed canisters with inert gas and possible trace amounts of air and water vapor. This study looks at the evolution of the thermal history of the canisters over a 50 year time period with a coupling to the chemical reactions occurring from radiolytic breakdown of residual water. A sensitivity study is then carried out over the parameters of the model including the fuel decay heat, residual water content, sealed pressure, canister external temperature, and canister emissivity. In pure helium, hydrogen generation rates are low, under 10 ppm, but hydrogen generation rates are affected greatly by the presence of even 1% residual air, increasing by 50-plus-fold, and nitric acid generation with residual air also occurs ranging from 500 to 4000 ppm after 50 years. The fuel decay heat and the residual water content show the most importance in the generation of hydrogen gas in pure air, and for nitric acid with a residual air condition. External temperature, canister emissivity and sealed pressure all show minor sensitivity effects to the generation of potentially harmful species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of effect of PWR cold leg temperature gradient on reactor core condition

Effects of temperature and flow gradients in Westinghouse designed three-loop Pressurized Water Reactor (PWR) cold legs, the piping between the main coolant pump and the reactor vessel, were evaluated using Computational Fluid Dynamics (CFD) code STAR CCM+ and coupled neutronic and thermal-hydraulic (T/H) code system VERA. In the parametric study, several symmetric and asymmetric temperature gradients that were significantly larger than those observed from plant measurements were applied to the cold leg inlets for comparison with the base case without any temperature gradient. A CFD model using the STAR-CCM+ code was developed for a portion of the RCS region between the Reactor Coolant Pump (RCP) and the core inlet based on previously validated modeling approach. The CFD simulation results were processed for the temperature and flow rate distributions at the core inlet as input to the VERA calculations. The VERA code system consists of COBRA-TF (CTF) for thermal-hydraulics, MPACT for reactor physics and neutron transport, and ORIGEN for isotopic depletion. The VERA model was for depletion calculations of a high-burnup loading pattern with the reactor core in pin-by-pin and subchannel resolution. The results of the study indicate that the postulated temperature gradients within the PWR cold legs do not result in any significant changes in the core inlet temperature distributions and the core power distributions during the reactor operation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Modeling-Based Flammable Risk Treatment of Refrigerant Leakage from a Commercial R-290 Refrigeration Machine

Because of serious concerns about global warming, manufacturers have started phasing out high global warming potential (GWP) refrigerants in commercial refrigeration equipment (e.g., R-134a). As a potential replacement, propane (R-290) is an environmentally friendly refrigerant for commercial refrigeration equipment because its GWP is only three. However, propane is flammable and is therefore classified as a Class A3 refrigerant per ASHRAE Standards, so safety is a very important consideration when propane-based equipment is designed and deployed in buildings. In the event of a refrigerant leak, flammability of the refrigerant depends on the refrigerant’s local concentration, which is highly affected by the indoor air environment, including temperature and air flow. In this study, a ventilation system attached to a commercial R-290 refrigeration device was designed to eliminate the flammability risk. Moreover, a computational fluid dynamics (CFD) model was developed to investigate the refrigerant leak, thereby evaluating effects of the ventilation system. The CFD model can visualize the flammable zones owing to the leak.

42 ENGINEERING↗

Achieving Tier 4 Emissions in Biomass Cookstoves

Previous literature on top-lit updraft (TLUD) gasifier cookstoves suggested that these stoves have the potential to be the lowest emitting biomass cookstove. However, the previous literature also demonstrated a high degree of variability in TLUD emissions and performance, and a lack of general understanding of the TLUD combustion process. The objective of this study was to improve understanding of the combustion process in TLUD cookstoves. In a TLUD, biomass is gasified and the resulting producer gas is burned in a secondary flame located just above the fuel bed. The goal of this project is to enable the design of a more robust TLUD that consistently meets Tier 4 performance targets through a better understanding of the underlying combustion physics. The project featured a combined modeling, experimental and product design/development effort comprised of four different activities: Development of a model of the gasification process in the biomass fuel bed; Development of a CFD model of the secondary combustion zone; Experiments with a modular TLUD test bed to provide information on how stove design, fuel properties, and operating mode influence performance and provide data needed to validate the fuel bed model; Planar laser-induced fluorescence (PLIF) experiments with a two-dimensional optical test bed to provide insight into the flame dynamics in the secondary combustion zone and data to validate the CFD model; Design, development and field testing of a market ready TLUD prototype. Over 180 tests of 40 different configurations of the modular TLUD test bed were performed to demonstrate how stove design, fuel properties and operating mode influences performance, and the conditions under which Tier 4 emissions are obtainable. Images of OH and acetone PLIF were collected at 10 kHz with the optical test bed. The modeling and experimental results informed the design of a TLUD prototype that met Tier 3 to Tier 4 specifications in emissions and Tier 2 in efficiency. The final prototype was field tested in India.

09 BIOMASS FUELS↗