Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Changes in Head Stability Control in Response to a Lateral Perturbation while Walking in Older Adults

Falling is a main contributor of injury in older adults. The decline in sensory systems associated with aging limits information needed to successfully compensate for unexpected perturbations. Therefore, sensory changes result in older adults having problems maintaining balance stability when experiencing an unexpected lateral perturbation (e.g. slip) in the environment. The goal of this study was to determine head stability movement strategies used by older adults when experiencing an unexpected lateral perturbation during walking. A total of 16 healthy adults, aged 66-81 years, walked across a foam pathway 6 times. One piece of the foam pathway covered a movable platform that translated to the left when the subject stepped on the foam. Three trials were randomized in which the platform shifted. Angular rate sensors were placed on the center of mass for the head and trunk segments to collect head and trunk movement in all three planes of motion. The predominant movement strategies for maintaining head stability were determined from the results of the cross-correlation analyses between the head and trunk segments. The Chi square test of independence was used to evaluate the movement pattern distributions of head-trunk coordination during perturbed and non-perturbed walking. When perturbed, head stabilization was significantly challenged in the yaw and roll planes of motion. Subjects demonstrated a movement pattern of the head leading the trunk in an effort to stabilize the head. The older adult subjects used this head stabilization movement pattern to compensate for sensory changes when experiencing the unexpected lateral perturbation.

Buccello, Regina R.↗

Lightning Charge Retrievals: Dimensional Reduction, LDAR Constraints, and a First Comparison w/ LIS Satellite Data

A "dimensional reduction" (DR) method is introduced for analyzing lightning field changes whereby the number of unknowns in a discrete two-charge model is reduced from the standard eight to just four. The four unknowns are found by performing a numerical minimization of a chi-squared goodness-of-fit function. At each step of the minimization, an Overdetermined Fixed Matrix (OFM) method is used to immediately retrieve the best "residual source". In this way, all 8 parameters are found, yet a numerical search of only 4 parameters is required. The inversion method is applied to the understanding of lightning charge retrievals. The accuracy of the DR method has been assessed by comparing retrievals with data provided by the Lightning Detection And Ranging (LDAR) instrument. Because lightning effectively deposits charge within thundercloud charge centers and because LDAR traces the geometrical development of the lightning channel with high precision, the LDAR data provides an ideal constraint for finding the best model charge solutions. In particular, LDAR data can be used to help determine both the horizontal and vertical positions of the model charges, thereby eliminating dipole ambiguities. The results of the LDAR-constrained charge retrieval method have been compared to the locations of optical pulses/flash locations detected by the Lightning Imaging Sensor (LIS).

Koshak, William↗

Lightning Charge Retrievals: Dimensional Reduction, LDAR Constraints, and a First Comparison with LIS Satellite Data

A "dimensional reduction" ("DR") method is introduced for analyzing lightning field changes ((Delta)Es) whereby the number of unknowns in a discrete two-charge model is reduced from the standard eight (x, y, z, Q, x', y', z', Q') to just four (x, y, z, Q). The four unknowns (x, y, z, Q) are found by performing a numerical minimization of a chi-square function. At each step of the minimization, an overdetermined fixed matrix (OFM) method is used to immediately retrieve the best "residual source" (x', y', z', Q'), given the values of (x, y, z, Q). In this way, all eight parameters Ix. y, z, Q, x', y', z', Q') are found, yet a numerical search of only four parameters (x, y, z, Q) is required. The DR method has been used to analyze lightning-caused (Delta)Es derived from multiple ground-based electric field measurements at the NASA Kennedy Space Center (KSC) and U.S. Air Force Eastern Range (ER). The accuracy of the DR method has been assessed by comparing retrievals with data provided by the lightning detection and ranging (LDAR) system at the KSC-ER. and from least squares error estimation theory, and the method is shown to be a useful "stand alone" charge retrieval tool. Since more than one charge distribution describes a finite set of (Delta)Es (i.e., solutions are nonunique), and since there can be appreciable differences in the physical characteristics of these solutions, not all DR solutions are physically acceptable. Hence. an alternative and more accurate method of analysis is introduced that uses LDAR data to constrain the geometry of the charge solutions. thereby removing physically unacceptable retrievals. The charge solutions derived from this method are shown to compare well with independent satellite- and ground-based observations of lightning m several Florida storms.

Koshak, W. J.↗

The Integrated Medical Model - Optimizing In-flight Space Medical Systems to Reduce Crew Health Risk and Mission Impacts

The Integrated Medical Model (IMM) is a decision support tool used by medical system planners and designers as they prepare for exploration planning activities of the Constellation program (CxP). IMM provides an evidence-based approach to help optimize the allocation of in-flight medical resources for a specified level of risk within spacecraft operational constraints. Eighty medical conditions and associated resources are represented in IMM. Nine conditions are due to Space Adaptation Syndrome. The IMM helps answer fundamental medical mission planning questions such as What medical conditions can be expected? What type and quantity of medical resources are most likely to be used?", and "What is the probability of crew death or evacuation due to medical events?" For a specified mission and crew profile, the IMM effectively characterizes the sequence of events that could potentially occur should a medical condition happen. The mathematical relationships among mission and crew attributes, medical conditions and incidence data, in-flight medical resources, potential clinical and crew health end states are established to generate end state probabilities. A Monte Carlo computational method is used to determine the probable outcomes and requires up to 25,000 mission trials to reach convergence. For each mission trial, the pharmaceuticals and supplies required to diagnose and treat prevalent medical conditions are tracked and decremented. The uncertainty of patient response to treatment is bounded via a best-case, worst-case, untreated case algorithm. A Crew Health Index (CHI) metric, developed to account for functional impairment due to a medical condition, provides a quantified measure of risk and enables risk comparisons across mission scenarios. The use of historical in-flight medical data, terrestrial surrogate data as appropriate, and space medicine subject matter expertise has enabled the development of a probabilistic, stochastic decision support tool capable of optimizing in-flight medical systems based on crew and mission parameters. This presentation will illustrate how to apply quantitative risk assessment methods to optimize the mass and volume of space-based medical systems for a space flight mission given the level of crew health and mission risk.

Kerstman, Eric↗

The Spectrum of Ultrahigh Energy Cosmic Rays and Constraints on Lorentz Invariance Violation

There has been much interest in possible violations of Lorentz invariance, particularly motivated by quantum gravity theories. It has been suggested that a small amount of Lorentz invariance violation (LIV) could turn off photomeson interactions of ultrahigh energy cosmic rays (UHECRs) with photons of the cosmic background radiation and thereby eliminate the resulting sharp steepening in the spectrum of the highest energy CRs predicted by Greisen Zatsepin and Kuzmin (GZK). Recent measurements of the UHECR spectrum reported by the HiRes and Auger collaborations, however, indicate the presence of the GZK effect. We present the results of a detailed calculation of the modification of the UHECR spectrum caused by LIV using the formalism of Coleman and Glashow. We then use a chi-squared analysis to compare our results with the experimental UHECR data and thereby place limits on the amount of LIV. We also discuss how a small amount of LIV that is consistent with the experimental data can still lead to a recovery of the cosmic ray flux at higher energies than presently observed.

Stecker, F. W.↗

Analytic Confusion Matrix Bounds for Fault Detection and Isolation Using a Sum-of-Squared- Residuals Approach

Given a system which can fail in 1 or n different ways, a fault detection and isolation (FDI) algorithm uses sensor data in order to determine which fault is the most likely to have occurred. The effectiveness of an FDI algorithm can be quantified by a confusion matrix, which i ndicates the probability that each fault is isolated given that each fault has occurred. Confusion matrices are often generated with simulation data, particularly for complex systems. In this paper we perform FDI using sums of squares of sensor residuals (SSRs). We assume that the sensor residuals are Gaussian, which gives the SSRs a chi-squared distribution. We then generate analytic lower and upper bounds on the confusion matrix elements. This allows for the generation of optimal sensor sets without numerical simulations. The confusion matrix bound s are verified with simulated aircraft engine data.

Simon, Dan↗

Suzaku observation of IGR J16318-4848

We report on the first Suzaku observation of IGR J16318-4848, the most extreme example of a new group of highly absorbed X-ray binaries that have recently been discovered by the International Gamma-Ray Astrophysics Laboratory (INTEGRAL). The Suzaku observation was carried out between 2006 August 14 and 17, with a net exposure time of 97 ks. The average X-ray spectrum of the source can be well described (chi-square (sub red)= 0.99) with a continuum model typical for neutron stars i.e., a strongly absorbed power law continuum with a photon index of 0.676(42) and an exponential cutoff at 20.5(6) keY. The absorbing column is N(sub H) = 1.95(3) X 10(exp 24)/square cm. Consistent with earlier work, strong fluorescent emission lines of Fe K-alpha, Fe K-beta, and Ni K-alpha are observed. Despite the large N(sub H), no Compton shoulder is seen in the lines, arguing for a non-spherical and inhomogeneous absorber. Seen at an average 5-60 keV absorbed flux of 3.4 x 10(exp -10) erg/square cm/second, the source exhibits significant variability on timescales of hours.

Barragan, Laura↗

Mineralogy of SNC Meteorite EET79001 by Simultaneous Fitting of Moessbauer Backscatter Spectra

We have acquired M ssbauer spectra for SNC meteorite EET79001 with a MIMOS II backscatter M ssbauer spectrometer [1] similar to those now operating on Mars as part of the Mars Exploration Rover (MER) missions. We are working to compare the Fe mineralogical composition of martian meteorites with in-situ measurements on Mars. Our samples were hand picked from the >1 mm size fraction of saw fines on the basis of lithology, color, and grain size (Table 1). The chips were individually analyzed at approx.300K by placing them on a piece of plastic that was in turn supported by the contact ring of the instrument (oriented vertically). Tungsten foil was used to mask certain areas from analysis. As shown in Figure 1, a variety of spectra was obtained, each resulting from different relative contributions of the Fe-bearing minerals present in the sample. Because the nine samples are reasonably mixtures of the same Fe-bearing phases in variable proportions, the nine spectra were fit simultaneously (simfit) with a common model, adjusting parameters to a single minimum chi-squared convergence criterion [2]. The starting point for the fitting model and values of hyperfine parameters was the work of Solberg and Burns [3], who identified olivine, pyroxene, and ferrous glass as major, and ilmenite and a ferric phase as minor (<5%), Fe-bearing phases in EET79001.

Morris, Richard V.↗

Nanomaterials Transform Hairstyling Tools

Dr. Dennis Morrison, a former scientist at Johnson Space Center, conducted research on microcapsules that were developed in space and designed to deliver drugs to cancerous tumors. This work led to research on nanoceramic materials, and in 2001, Morrison shared his expertise with Farouk Shami, the owner of Farouk Systems Inc., of Houston, Texas. After learning more, Shami developed a ceramic composite for his CHI (Cationic Hydration Interlink) hairstyling irons, brushes, nail lacquers, and hair dryers. Morrison also used his NASA research expertise as a platform to incorporate nanosilver and near-infrared light into the products.

Source record↗

An Empirical State Error Covariance Matrix for Batch State Estimation

State estimation techniques serve effectively to provide mean state estimates. However, the state error covariance matrices provided as part of these techniques suffer from some degree of lack of confidence in their ability to adequately describe the uncertainty in the estimated states. A specific problem with the traditional form of state error covariance matrices is that they represent only a mapping of the assumed observation error characteristics into the state space. Any errors that arise from other sources (environment modeling, precision, etc.) are not directly represented in a traditional, theoretical state error covariance matrix. Consider that an actual observation contains only measurement error and that an estimated observation contains all other errors, known and unknown. It then follows that a measurement residual (the difference between expected and observed measurements) contains all errors for that measurement. Therefore, a direct and appropriate inclusion of the actual measurement residuals in the state error covariance matrix will result in an empirical state error covariance matrix. This empirical state error covariance matrix will fully account for the error in the state estimate. By way of a literal reinterpretation of the equations involved in the weighted least squares estimation algorithm, it is possible to arrive at an appropriate, and formally correct, empirical state error covariance matrix. The first specific step of the method is to use the average form of the weighted measurement residual variance performance index rather than its usual total weighted residual form. Next it is helpful to interpret the solution to the normal equations as the average of a collection of sample vectors drawn from a hypothetical parent population. From here, using a standard statistical analysis approach, it directly follows as to how to determine the standard empirical state error covariance matrix. This matrix will contain the total uncertainty in the state estimate, regardless as to the source of the uncertainty. Also, in its most straight forward form, the technique only requires supplemental calculations to be added to existing batch algorithms. The generation of this direct, empirical form of the state error covariance matrix is independent of the dimensionality of the observations. Mixed degrees of freedom for an observation set are allowed. As is the case with any simple, empirical sample variance problems, the presented approach offers an opportunity (at least in the case of weighted least squares) to investigate confidence interval estimates for the error covariance matrix elements. The diagonal or variance terms of the error covariance matrix have a particularly simple form to associate with either a multiple degree of freedom chi-square distribution (more approximate) or with a gamma distribution (less approximate). The off diagonal or covariance terms of the matrix are less clear in their statistical behavior. However, the off diagonal covariance matrix elements still lend themselves to standard confidence interval error analysis. The distributional forms associated with the off diagonal terms are more varied and, perhaps, more approximate than those associated with the diagonal terms. Using a simple weighted least squares sample problem, results obtained through use of the proposed technique are presented. The example consists of a simple, two observer, triangulation problem with range only measurements. Variations of this problem reflect an ideal case (perfect knowledge of the range errors) and a mismodeled case (incorrect knowledge of the range errors).

Frisbee, Joseph H., Jr.↗

Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (<50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also >100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P < 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P < 0.05), whereas mean HF QRS amplitude was decreased significantly (P < 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P < 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection of canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.

Spiljak, M.↗

Star Confusion Effect on SIM PlanetQuest Astrometric Performance

SIM PlanetQuest will measure star positions to an accuracy of a few microarcseconds using precise white light fringe measurements. One challenge for SIM observation scenario is "star confusion," where multiple stars are present in the instrument field of view. This is especially relevant for observing dim science targets because the density of number of stars increases rapidly with star magnitude. We study the effect of star confusion on the SIM astrometric performance due to systematic fringe errors caused by the extra photons from the confusion star(s}. Since star confusion from multiple stars may be analyzed as a linear superposition of the effect from single star confusion, we quantify the astrometric errors due to single star confusion surveying over many spectral types, including AOV, FOV, K5III, and MOV, and for various visual magnitude differences. To the leading order, the star confusion effect is characterized by the magnitude difference, spectral difference, and the angular separation between the target and confusion stars.Strategies for dealing with star confusion are presented. For example, since the presence of additional sources in the field of view leads to inconsistent delay estimates from different channels, with sufficient signal to noise ratio, the star confusion can be detected using chi-square statistics of fringe measurements from multiple spectral channels. An interesting result is that the star confusion can be detected even though the interferometer cannot resolve the separation between the target and confusion stars when their spectra are sufficiently different. Other strategies for mitigating the star confusion effect are also discussed.

crowded field↗

The Atacama Cosmology Telescope: Cosmological Parameters from the 2008 Power Spectrum

We present cosmological parameters derived from the angular power spectrum of the cosmic microwave background (CMB) radiation observed at 148 GHz and 218 GHz over 296 deg(exp 2) with the Atacama Cosmology Telescope (ACT) during its 2008 season. ACT measures fluctuations at scales 500 < l < 10,000. We fit a model for the lensed CMB, Sunyaev-Zel'dovich (SZ), and foreground contribution to the 148 GHz and 218 GHz power spectra, including thermal and kinetic SZ, Poisson power from radio and infrared point sources, and clustered power from infrared point sources. At l = 3000, about half the power at 148 GHz comes from primary CMB after masking bright radio sources. The power from thermal and kinetic SZ is estimated to be Beta(sub 3000) is identical to 6.8 +/- 2.9 mu K (exp 2), where Beta (sub l) is identical to l(l + 1) C(sub l)/2pi. The IR Poisson power at 148 GHz is Bewta(sub 3000) 7.8 +/- 0.7 muK(exp 2) (C(sub l) = 5.5 +/- 0.5 nK(exp 2)), and a clustered IR component is required with Beta (sub 3000) = 4.6 +/- 0.9 muK(exp 2), assuming an analytic model for its power spectrum shape. At 218 GHz only about 15% of the power, approximately 27 mu K(exp 2), is CMB anisotropy at l = 3000. The remaining 85% is attributed to IR sources (approximately 50% Poisson and 35% clustered), with spectral index alpha = 3.69 +/- 0.14 for flux scaling as S(nu) varies as nu(sup alpha). We estimate primary cosmological parameters from the less contaminated 148 GHz spectrum, marginalizing over SZ and source power. The ACDM cosmological model is a good fit to the data (chi square/dof = 29/46), and ACDM parameters estimated from ACT+Wilkinson Microwave Anisotropy Probe (WMAP) are consistent with the seven-year WMAP limits, with scale invariant n(sub s) = 1 excluded at 99.7% confidence level (CL) (3 sigma). A model with no CMB lensing is disfavored at 2.8 sigma. By measuring the third to seventh acoustic peaks, and probing the Silk damping regime, the ACT data improve limits on cosmological parameters that affect the small-scale CMB power. The ACT data combined with WMAP give a 6 sigma detection of primordial helium, with Y(sub p) = 0.313 +/- 0.044, and a 4 sigma detection of relativistic species, assumed to be neutrinos, with N(sub eff) = 5.3 +/- 1.3 (4.6 +/- 0.8 with BAO+H(sub 0) data). From the CMB alone the running of the spectral index is constrained to be d(sub s) / d ln k = -0,034 +/- 0,018, the limit on the tensor-to-scalar ratio is r < 0,25 (95% CL), and the possible contribution of Nambu cosmic strings to the power spectrum is constrained to string tension G(sub mu) < 1.6 x 10(exp -7) (95% CL),

Dunkley, J.↗

Time-Average Measurement of Velocity, Density, Temperature, and Turbulence Using Molecular Rayleigh Scattering

Measurement of time-averaged velocity, density, temperature, and turbulence in gas flows using a nonintrusive, point-wise measurement technique based on molecular Rayleigh scattering is discussed. Subsonic and supersonic flows in a 25.4-mm diameter free jet facility were studied. The developed instrumentation utilizes a Fabry-Perot interferometer to spectrally resolve molecularly scattered light from a laser beam passed through a gas flow. The spectrum of the scattered light contains information about velocity, density, and temperature of the gas. The technique uses a slow scan, low noise 16-bit depth CCD camera to record images of the fringes formed by Rayleigh scattered light passing through the interferometer. A kinetic theory model of the Rayleigh scattered light is used in a nonlinear least squares fitting routine to estimate the unknown parameters from the fringe images. The ability to extract turbulence information from the fringe image data proved to be a challenge since the fringe is broadened by not only turbulence, but also thermal fluctuations and aperture effects from collecting light over a range of scattering angles. Figure 1 illustrates broadening of a Rayleigh spectrum typical of flow conditions observed in this work due to aperture effects and turbulence for a scattering angle, chi(sub s), of 90 degrees, f/3.67 collection optics, mean flow velocity, u(sub k), of 300 m/s, and turbulent velocity fluctuations, sigma (sub uk), of 55 m/s. The greatest difficulty in processing the image data was decoupling the thermal and turbulence broadening in the spectrum. To aid in this endeavor, it was necessary to seed the ambient air with smoke and dust particulates; taking advantage of the turbulence broadening in the Mie scattering component of the spectrum of the collected light (not shown in the figure). The primary jet flow was not seeded due to the difficulty of the task. For measurement points lacking particles, velocity, density, and temperature information could reliably be recovered, however the turbulence estimates contained significant uncertainty. Resulting flow parameter estimates are presented for surveys of Mach 0.6, 0.95, and 1.4 jet flows. Velocity, density, and temperature were determined with accuracies of 5 m/s, 1.5%, and 1%, respectively, in flows with no particles present, and with accuracies of 5 m/s, 1-4%, and 2% in flows with particles. Comparison with hotwire data for the Mach 0.6 condition demonstrated turbulence estimates with accuracies of about 5 m/s outside the jet core where Mie scattering from dust/smoke particulates aided in the estimation of turbulence. Turbulence estimates could not be recovered with any significant accuracy for measurement points where no particles were present.

Mielke, Amy F.↗

The Faint "Heartbeats" of IGR J17091-3624: An Exceptional Black Hole Candidate

We report on the first 180 days of Rossi X-Ray Timing Explorer observations of the outburst of the black hole candidate IGR Jl7091-3624. This source exhibits a broad variety of complex light curve patterns including periods of strong flares alternating with quiet intervals. Similar patterns in the X-ray light curves have been seen in the (up to now) unique black hole system GRS 1915+105. In the context of the variability classes defined by Belloni et al. for GRS 1915+105, we find that JGR J17091-3624 shows the nu, rho, alpha, lambda, Beta, and mu classes as well as quiet periods which resemble the chi class, all occurring at 2-60 keY count rate levels which can be 10-50 times lower than observed in GRS 1915+\05. The so-called rho class "heartbeats" occur as fast as every few seconds and as slow as approx 100 s, tracing a loop in the hardness-intensity diagram which resembles that previously seen in GRS 1915+\05. However, while GRS 1915+105 traverses this loop clockwise, IGR Jl7091-3624 does so in the opposite sense. We briefly discuss our findings in the context of the models proposed for GRS 1915+105 and find that either all models requiring near Eddington luminosities for GRS 1915+105-like variability fail, or IGR Il7091-3624 lies at a distance well in excess of 20 kpc, or it harbors one of the least massive black holes known( <3 solar M).

Altamirano, D.↗

Deriving Plasma Densities and Elemental Abundances from SERTS Differential Emission Measure Analysis

We use high-resolution spectral emission line data obtained by the SERTS instrument during three rocket flights to demonstrate a new approach for constraining electron densities of solar active region plasma.We apply differential emission measure (DEM) forward-fitting techniques to characterize the multithermal solar plasma producing the observed EUV spectra, with constraints on the high-temperature plasma from the Yohkoh Soft X-ray Telescope. In this iterative process, we compare line intensities predicted by an input source distribution to observed line intensities for multiple iron ion species, and search a broad range of densities to optimize chi-square simultaneously for the many available density-sensitive lines. This produces a density weighted by the DEM, which appears to be useful for characterizing the bulk of the emitting plasma over a significant range of temperature. This "DEM-weighted density" technique is complementary to the use of density-sensitive line ratios and less affected by uncertainties in atomic data and ionization fraction for any specific line. Once the DEM shape and the DEM-weighted density have been established from the iron lines, the relative elemental abundances can be determined for other lines in the spectrum. We have also identified spectral lines in the SERTS wavelength range that may be problematic

corona↗

Application of a Hough Search for Continuous Gravitational Waves on Data from the Fifth LIGO Science Run

We report on an all-sky search for periodic gravitational waves in the frequency range 50-1000 Hertz with the first derivative of frequency in the range −8.9 × 10(exp −10) Hertz per second to zero in two years of data collected during LIGO's fifth science run. Our results employ a Hough transform technique, introducing a chi(sup 2) test and analysis of coincidences between the signal levels in years 1 and 2 of observations that offers a significant improvement in the product of strain sensitivity with compute cycles per data sample compared to previously published searches. Since our search yields no surviving candidates, we present results taking the form of frequency dependent, 95% confidence upper limits on the strain amplitude h(sub 0). The most stringent upper limit from year 1 is 1.0 × 10(exp −24) in the 158.00-158.25 Hertz band. In year 2, the most stringent upper limit is 8.9 × 10(exp −25) in the 146.50-146.75 Hertz band. This improved detection pipeline, which is computationally efficient by at least two orders of magnitude better than our flagship Einstein@Home search, will be important for 'quicklook' searches in the Advanced LIGO and Virgo detector era.

neutron stars↗

Potential Energy Curves for CO

Potential energy curves for the Chi (sup 1) Epsilon (sup plus), alpha (sup 3) II (sub r), alpha prime (sup 3) epsilon (sup plus), d (sup 3) delta, e (sup 3) Epsilon (sup minus), Alpha (sup 1) II, and Beta (sup 1) Epsilon (sup plus), electronic states of the CO molecule have been calculated by the Rydberg-Klein-Rees method. The curve for the A III state will have to bend sharply in the range between 1.9 and 2.1 angstroms or it will have to pass through a maximum to reach the proper dissociation limit.

Tobias, Irwin↗