Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Thermal and oxidative degradation studies of formulated C-ethers by gel-permeation chromatography

Gel-permeation chromatography was used to analyze C-ether lubricant formulations from high-temperature bearing tests and from micro-oxidation tests. Three mu-styragel columns (one 500 and two 100 A) and a tetrahydrofuran mobile phase were found to adequately separate the C-ether degradation products. The micro-oxidation tests yielded degradation results qualitatively similar to those observed from the bearing tests. Micro-oxidation tests conducted in air yielded more degradation than did tests in nitrogen. No great differences were observed between the thermal-oxidative stabilities of the two C-ether formulations or between the catalytic degradation activities of silver and M-50 steel. C-ether formulation I did yield more degradation than did formulation II in 111- and 25-hour bearing tests, respectively.

Jones, W. R., Jr.↗

Quantitative separation of tetralin hydroperoxide from its decomposition products by high performance liquid chromatography

A method for the separation and analysis of tetralin hydroperoxide and its decomposition products by high pressure liquid chromatography has been developed. Elution with a single, mixed solvent from a micron-Porasil column was employed. Constant response factors (internal standard method) over large concentration ranges and reproducible retention parameters are reported.

Worstell, J. H.↗

Analysis of a MIL-L-27502 lubricant from a gas-turbine engine test by size-exclusion chromatography

Size exclusion chromatography was used to determine the chemical degradation of MIL-L-27502 oil samples from a gas turbine engine test run at a bulk oil temperature of 216 C. Results revealed a progressive loss of primary ester and additive depletion and the formation of higher molecular weight products with time. The high molecular weight products absorbed strongly in the ultraviolet indicating the presence of chromophoric groups.

Jones, W. R., Jr.↗

Mineral Separation in a CELSS by Ion-exchange Chromatography

Operational parameters pertinent to ion exchange chromatography separation were identified. The experiments were performed with 9 mm diameter ion exchange columns and conventional column accessories. The cation separation beds were packed with AG 50W-X2 strong acid cation exchange resin in H(+) form and 200-400 dry mesh particle size. The stripper beds used in some experiments were packed with AG 1-XB strong base cation exchange resin in OH(-) form and 200-400 dry mesh particle size.

Ballou, E. V.↗

Rapid estimation of concentration of aromatic classes in middistillate fuels by high-performance liquid chromatography

An high performance liquid chromatography (HPLC) method to estimate four aromatic classes in middistillate fuels is presented. Average refractive indices are used in a correlation to obtain the concentrations of each of the aromatic classes from HPLC data. The aromatic class concentrations can be obtained in about 15 min when the concentration of the aromatic group is known. Seven fuels with a wide range of compositions were used to test the method. Relative errors in the concentration of the two major aromatic classes were not over 10 percent. Absolute errors of the minor classes were all less than 0.3 percent. The data show that errors in group-type analyses using sulfuric acid derived standards are greater for fuels containing high concentrations of polycyclic aromatics. Corrections are based on the change in refractive index of the aromatic fraction which can occur when sulfuric acid and the fuel react. These corrections improved both the precision and the accuracy of the group-type results.

Otterson, D. A.↗

multiplex gas chromatography: A novel analytical technique for future planetary studies

Determination of molecular species comprised of the biogenic elements in the atmospheres of planets and moons of the solar system is one the foremost requirements of the exobiologist studying chemical evolution and the origin of life. Multiplex chromatography is a technique where many samples are pseudo-randomly introduced to the chromatograph without regard to elution of preceding components. The resulting data are then reduced using mathematical techniques such as cross correlation or Fourier Transforms. To demonstrate the utility of this technique for future solar system exploration, chemical modulators were developed. Several advantages were realized from this technique in combination with these modulators: improvement in detection limits of several orders of magnitude, improvement in the analysis of complex mixtures by selectively modulating some of the components present in the sample, increase in the number of analyses that can be conducted in a given period of time, and reduction in the amount of expendables needed to run an analysis. In order to apply this technique in a real application, methane in ambient air was monitored continuously over a period of one week. By using ambient air as its own carrier all expendables beyond power were eliminated.

Valentin, J. R.↗

Determination of low molecular weight thiols using monobromobimane fluorescent labeling and high-performance liquid chromatography

Methods are described for the preparation and high-performance liquid chromatography (HPLC) analysis of monobromobimane derivatives of low molecular weight thiols in extracts of biological samples. Typical problems encountered in the development and application of these methods are discussed. Analysis of mung bean extract is used as an example.

Fahey, Robert C.↗

Inverse gas chromatography. V - Computer simulation of diffusion processes on the column

The elution behavior of low molecular weight probes on inverse gas chromatography (IGC) columns is simulated using a computer. The IGC model is based on a polymer stationary phase of uniform thickness with a nonnegligible resitance to probe penetration. Three characteristic numbers are found to determine the whole process: Z(p) characterizing the distribution of the probe between phases, Z(f) describing the diffusion in the polymer phase, and Z(g) related to diffusion in the gaseous phase. For situations when Z(p)/Z(f) is less than 2, the standard evaluation procedures are virtually useless. The actual behavior of such systems is described.

Hattam, Paul↗

Multiplex gas chromatography

The principles of the multiplex gas chromatography (GC) technique, which is a possible candidate for chemical analysis of planetary atmospheres, are discussed. Particular attention is given to the chemical modulators developed by present investigators for multiplex GC, namely, the thermal-desorption, thermal-decomposition, and catalytic modulators, as well as to mechanical modulators. The basic technique of multiplex GC using chemical modulators and a mechanical modulator is demonstrated. It is shown that, with the chemical modulators, only one gas stream consisting of the carrier in combination with the components is being analyzed, resulting in a simplified instrument that requires relatively few consumables. The mechanical modulator demonstrated a direct application of multiplex GC for the analysis of gases in atmosphere of Titan at very low pressures.

Valentin, Jose R.↗

Continuous monitoring of a changing sample by multiplex gas chromatography

Results are presented from a study in which a continuously changed gaseous sample was monitored by multiplex gas chromatography (MGC), using the exponential dilution (ED) technique of Ritter and Adams (1976) to change the composition and concentration of a gaseous mixture in such a way as to imitate changes in the atmospheric gases sampled by a descending aircraft. A calibration of the MGC system was performed with four different rates of sample dilution, and the errors resulting from various degrees of change in the sample concentration were determined.

Valentin, Jose R.↗

NASA Li/CF(x) cell problem analysis: Anion exchange chromatography analysis

An analysis was made of wiper samples used to wipe down lithium/chlorine fluorine battery components and production equipment. These components and equipment were potentially exposed to thionyl chloride vapors. In the presence of moisture, thionyl chloride decomposes to sulfur dioxide and hydrogen chloride. The wiper samples were analyzed for soluble chlorides and fluorides by anion exchange chromatography. During the examination of the test chromatographs, fluoride contamination was discovered in wiper samples from the test equipment. An analytical method to determine fluoride was developed. The first 3 extracts from the potentially exposed and clean wiper samples were tested, and the total fluoride from both groups determined. A comparison of the results from both groups was made to determine the extent of fluoride contamination.

Bytella, Joseph↗

Long term monitoring of methane in the atmosphere by multiplex gas chromatography

Methane is of interest in the study of the Earth's atmosphere because of its implication in the future global warming of the surface. This warming is produced by the absorption of infrared energy by trace gases. It has been estimated that in the next 40 to 50 years, methane could contribute 20 to 25 pct. as much atmospheric warming as that expected from carbon dioxide increases. Studies to examine sources, sinks, and cycles of methane will require analytical methods capable of continuous unattended measurement with temporal resolution of an hour or less for weeks at a time. Gas chromatography (GC) is one of the most practical methods available to conduct the analysis of air, but limitations in this technique still exist which can be alleviated with multiplex GC (MGC). MGC is a technique where many samples are pseudo-randomly introduced to the chromatograph without regard to the length of time required for an analysis. The resulting data must then be reduced using computational methods such as cross correlation. In the technique reported, a tube packed with silver oxide was used at the inlet of the GC column to create concentration pulses of methane in a sample stream of air. By using only one carrier, i.e., ambient air, an effective and accurate method to monitor the variations in concentration of methane in the atmosphere over long periods of time was developed. Methane in ambient air was monitored for an eight day period and an interesting temporal variability was found. This work has shown the utility of a relatively simple MGC for the analysis of a real environmental sample.

Valentin, Jose R.↗

Thermal History Of PMRs Via Pyrolysis-Gas Chromatography

Pyrolysis-gas chromatography (PY-GC) useful as analytical technique to determine extents of cure or postcure of PMR-15 polyimides and to lesser extent, cumulative thermal histories of PMR-15 polyimides exposed to high temperatures. Also applicable for same purposes to other PMR polyimides and to composite materials containing PMR polyimides. Valuable in reducing costs and promoting safety in aircraft industry by helping to identify improperly cured or postcured PMR-15 composite engine and airframe components and helping to identify composite parts nearing ends of their useful lives.

Gluyas, Richard E.↗

Highly crosslinked silicon polymers for gas chromatography columns

A new highly crosslinked silicone polymer particle for gas chromatography application and a process for synthesizing such copolymer are described. The new copolymer comprises vinyltriethoxysilane and octadecyltrichlorosilane. The copolymer has a high degree of crosslinking and a cool balance of polar to nonpolar sites in the porous silicon polymer assuring fast separation of compounds of variable polarity.

Shen, Thomas C.↗

Hand-portable gas chromatography-ion mobility spectrometer for the determination of the freshness of fish

A hand-held, portable gas chromatography-ion mobility spectrometer (GC-IMS) device was used to detect the presence of volatile amine compounds in the headspace of decomposing fish. The Food and Drug Administration (FDA) largely relies on olfactory discrimination with respect to fresh and spoiled, frozen and unfrozen fish. The fish are delivered at ship docks on pallets, and each pallet of fish can range from 30-40 thousand dollars in value. Fresh fish were placed in a teflon bag and the direct headspace was interrogated. In the first three days, only low molecular weight volatile amines were detected. On the fourth day, a number of spectral signatures were observed which indicated the presence of 1,5-diaminopentane, cadaverine. Analyses typically took from 0.5-1 minute.

Snyder, A. Peter↗

Separation of 'Uncharged' Oligodeoxynucleotide Analogs by Anion-Exchange Chromatography at High pH

Ion-exchange chromatography is a well-established method for the analysis and purification of phosphodiester-linked oligonucleotides. If elution is carried out under alkaline conditions, the secondary structure of G- and C-rich oligomers is disrupted. Furthermore, elution times become more sensitive to the G and T content of the oligomer, because G and T are deprotonated at pH 10. In recent work on peptide-nucleic acids (PNAs) we noted that mixtures of PNA oligomers G(sub 4), G(sub 6), G(sub 8), and G9(sub 10) are readily separated by elution at pH 12 on an RPC-5 column. Here we show that this separation method is more generally applicable.

Schmidt, Jurgen G.↗

Separation of Uncharged Oligodeoxynucleotide Analogs by Anion-Exchange Chromatography at High pH

Ion-exchange chromatography is a well-established method for the analysis and purification of phosphodiester-linked oligonucleotides. If elution is carried out under alkaline conditions, the secondary structure of G- and C-rich oligomers is disrupted. Furthermore, elution times become more sensitive to the G and T content of the oligomer, because G and T are deprotonated at pH 10. In recent work on peptide-nucleic acids (PNAs) we noted that mixtures of PNA oligomers G(sub 4), G(Sub 6), G(sub 8), and G(sub 10) are readily separated by elution at pH 12 on an RPC-5 column. Here we show that this separation method is more generally applicable.

Schmidt, Jurgen G.↗

Gel Permeation Chromatography of Fluoroether Polymers

A Method is described for determining the molecular weight distribution of fluorinated polymers by gel permeation chromatography. Porous silica-packed columns are used with Freon 113 as the chromatographic solvent. Fluoroether oligomers are used for column calibration in the molecular weight range of 1400 to 12000.

Korus, Roger A.↗