Search NASA⌕ Search

SEARCH · Search NASA

Results for “CLINICAL MEDICINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

334 records · Page 19

Optimization of a Lethal, Combat-Relevant Model of Sterile Inflammation in Mice for Drug Candidate Screening

ABSTRACT Introduction Extensive trauma, commonly seen in wounded military Service Members, often leads to a severe sterile inflammation termed systemic inflammatory response syndrome (SIRS), which can progress to multiple organ dysfunction syndrome (MODS) and death. MODS is a serious threat to wounded Service Members, historically causing 10% of all deaths in trauma admissions at a forward deployed combat hospital. The importance of this problem will be exacerbated in large-scale combat operations, in which evacuation will be delayed and care of complex injuries at lower echelons of care may be prolonged. The main goal of this study was to optimize an existing mouse model of lethal SIRS/MODS as a therapeutic screening platform for the evaluation of immunomodulatory drugs. Materials and Methods Male C57BL/6 mice were euthanized, and the bones and muscles were collected and blended into a paste termed tissue–bone matrix (TBX). The TBX at 12.5%–20% relative to body weight of each recipient mouse was implanted into subcutaneous pouches created on the dorsum of anesthetized animals. Mice were observed for clinical scores for up to 48 hours postimplantation and euthanized at the preset point of moribundity. To test effects of anesthetics on TBX-induced mortality, animals received isoflurane or ketamine/xylazine (K/X). In a separate set of studies, mice received TBX followed by intraperitoneal injection with 20 mg/kg or 40 mg/kg Eritoran or a placebo carrier. All Eritoran studies were performed in a blinded fashion. Results We observed that K/X anesthesia significantly increased the lethality of the implanted TBX in comparison to inhaled anesthetics. Although all the mice anesthetized with isoflurane and implanted with 12.5% TBX survived for 24 hours, 60% of mice anesthetized with K/X were moribund by 24 hours postimplantation. To mimic more closely the timing of lethal SIRS/MODS following polytrauma in human patients, we extended observation to 48 hours. We performed TBX dose–response studies and found that as low as 15%, 17.5%, and 20% TBX caused moribundity/mortality in 50%, 80%, and 100% mice, respectively, over a 48-hour time period. With 17.5% TBX, we tested if moribundity/mortality could be rescued by anti-inflammatory drug Eritoran, a toll-like receptor 4 antagonist. Neither 20 mg/kg nor 40 mg/kg doses of Eritoran were found to be effective in this model. Conclusions We optimized a TBX mouse model of SIRS/MODS for the purpose of evaluating novel therapeutic interventions to prevent trauma-related pathophysiologies in wounded Service Members. Negative effects of K/X on lethality of TBX should be further evaluated, particularly in the light of widespread use of ketamine in treatment of pain. By mimicking muscle crush, bone fracture, and necrosis, the TBX model has pleiotropic effects on physiology and immunology that make it uniquely valuable as a screening tool for the evaluation of novel therapeutics against trauma-induced SIRS/MODS.

General & Internal Medicine↗

Announcing the Biomedical Data Translator: Initial Public Release

ABSTRACT The growing availability of biomedical data offers vast potential to improve human health, but the complexity and lack of integration of these datasets often limit their utility. To address this, the Biomedical Data Translator Consortium has developed an open‐source knowledge graph–based system—Translator—designed to integrate, harmonize, and make inferences over diverse biomedical data sources. We announce here Translator's initial public release and provide an overview of its architecture, standards, user interface, and core features. Translator employs a scalable, federated, knowledge graph framework for the integration of clinical, genomic, pharmacological, and other biomedical knowledge sources, enabling query retrieval, inference, and hypothesis generation. Translator's user interface is designed to support the exploration of knowledge relationships and the generation of insights, without requiring deep technical expertise and gradually revealing more detailed evidence, provenance, and confidence information, as needed by a given user. To demonstrate Translator's application and impact, we highlight features of the user interface in the context of three real‐world use cases: suggesting potential therapeutics for patients with rare disease; explaining the mechanism of action of a pipeline drug; and screening and validating drug candidates in a model organism. We discuss strengths and limitations of reasoning within a largely federated system and the need for rich concept modeling and deep provenance tracking. Finally, we outline future directions for enhancing Translator's functionality and expanding its data sources. Translator represents a significant step forward in making complex biomedical knowledge more accessible and actionable, aiming to accelerate translational research and improve patient care.

Research & Experimental Medicine↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Influence of the broadly neutralizing antibody VRC01 on HIV breakthrough virus populations in antibody-mediated prevention trials

In the antibody mediated prevention (AMP) trials, the broadly neutralizing antibody (bNAb) VRC01 demonstrated protective efficacy against susceptible HIV strains. To understand how VRC01 shaped breakthrough infections, deep sequencing was performed on 172 participants (>100,000 gag-Δpol and rev-env-Δnef sequences), at diagnosis and over time, in the placebo and treatment arms of the African (HVTN703/HPTN081; NCT02568215) and Americas/Europe (HVTN704/HPTN085; NCT02716675) cohorts. A high frequency of multilineage infections was detected (38%), including co-infection with both VRC01 sensitive and resistant viruses. This high frequency is largely accounted for by low-abundance lineages. Although VRC01 does not significantly affect the genetic transmission bottleneck compared to placebo, higher VRC01 doses trend towards greater VRC01 neutralization differences among co-infecting lineages. Two-thirds of multilineage infections showed evidence of recombination at the diagnostic timepoint. In the treatment group there is evidence of recombinant viruses preferentially inheriting resistance-associated mutations. This study provides critical insights into viral genetic and antigenic diversity that needs to be targeted to achieve protection, and highlights the role of recombination in facilitating escape.

59 BASIC BIOLOGICAL SCIENCES↗

Aeromonas in South Asia: genomic insights into an environmental pathogen and reservoir of antimicrobial resistance

Aeromonads are an ecologically versatile group of bacteria that cause infections in aquatic animals and are recognised as emerging human pathogens. Despite this, our understanding of Aeromonas diversity, especially the relationship between clinical and environmental strains, remains limited. Here, we present a genomic analysis of the Aeromonas genus, comprising 1853 genomes, and a detailed comparison of clinical and environmental strains from South Asia, including 996 newly sequenced genomes from Bangladesh and India. Phylogenetic analyses revealed that Aeromonas is a highly diverse genus, with no distinct clade separating clinical and environmental isolates. We identified 28 Aeromonas species and 905 novel sequence types, comprising 72.5% of the genomes. Notably, we show a high incidence of antimicrobial resistance (AMR) genes across all isolates, including against front and last-line antibiotics. Finally, we highlight frequent misidentification of Aeromonas as Vibrio cholerae, which is relevant to cholera-endemic regions where both genera co-exist and are associated with diarrhoeal disease. Our study underscores Aeromonas as an important environmental AMR reservoir and emerging multi-species pathogen capable of spilling over into human populations.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of Candidate Theranostics for 227 Th/ 89 Zr Paired Radioimmunotherapy of Lymphoma

227 Th is a promising radioisotope for targeted α-particle therapy. It produces 5 α-particles through its decay, with the clinically approved 223 Ra as its first daughter. There is an ample supply of 227 Th, allowing for clinical use; however, the chemical challenges of chelating this large tetravalent f-block cation are considerable. Using the CD20-targeting antibody ofatumumab, we evaluated chelation of 227 Th 4+ for α-particle–emitting and radiotheranostic applications. Methods: We compared 4 bifunctional chelators for thorium radiopharmaceutical preparation: S-2-(4-Isothiocyanatobenzyl)-1,4,7,10-tetraazacyclododecane tetraacetic acid (p-SCN-Bn-DOTA), 2-(4-isothicyanatobenzyl)-1,2,7,10,13-hexaazacyclooctadecane-1,4,7,10,13,16-hexaacetic acid (p-SCN-Bn-HEHA), p-isothiacyanatophenyl-1-hydroxy-2-oxopiperidine-desferrioxamine (DFOcyclo*-p-Phe-NCS), and macrocyclic 1,2-HOPO N-hydroxysuccinimide (L804-NHS). Immunoconstructs were evaluated for yield, purity, and stability in vitro and in vivo. Tumor targeting of the lead 227 Th-labeled compound in vivo was performed in CD20-expressing models and compared with a companion 89 Zr-labeled PET agent. Results: 227 Th-labeled ofatumumab-chelator constructs were synthesized to a radiochemical purity of more than 95%, excepting HEHA. 227 Th-HEHA-ofatumumab showed moderate in vitro stability. 227 Th-DFOcyclo*-ofatumumab presented excellent 227 Th labeling efficiency; however, high liver and spleen uptake was revealed in vivo, indicative of aggregation. 227 Th-DOTA-ofatumumab labeled poorly, yielding no more than 5%, with low specific activity (0.08 GBq/g) and modest long-term in vitro stability (<80%). 227 Th-L804-ofatumumab coordinated 227 Th rapidly and efficiently at high yields, purity, and specific activity (8 GBq/g) and demonstrated extended stability. In vivo tumor targeting confirmed the utility of this chelator, and the diagnostic analog, 89 Zr-L804-ofatumumab, showed organ distribution matching that of 227 Th to delineate SU-DHL-6 tumors. Conclusion: Commercially available and novel chelators for 227 Th showed a range of performances. The L804 chelator can be used with potent radiotheranostic capabilities for 89 Zr/ 227 Th quantitative imaging and α-particle therapy.

227Th↗

Nuclear excitation functions for medical isotope production: Targeted radionuclide therapy via nat IR$(d, x)$ 193m Pt

193m Pt is an Auger emitting radionuclide which may have therapeutic potential, particularly when labeled to the chemotherapeutic drug cisplatin. One challenge to broader explorations of its clinical potential is the need for production routes with high specific activity. As part of a larger campaign to address gaps in reaction data for emerging medical radionuclides, this work seeks to characterize the nat Ir(d,x) reactions as a potential production pathway for 193m Pt. A stacked target irradiation, consisting of natural iridium, iron, nickel, and copper foils, was performed using a 33 MeV deuteron beam at the Lawrence Berkeley National Laboratory 88-Inch Cyclotron. This measurement, along with previous experimental data, suggests an energy window between 11 to 18 MeV to maximize the production and radiopurity of 193m Pt. This experiment has yielded cross sections for 43 channels of deuteron-induced reactions from threshold to 30 MeV, including the first experimental results of nat Ir(d,x) 188m1+g,190m1+g Ir (cumulative), nat Ni(d,x) 56,57,58 m,58g Co (independent), nat Cu(d,x) 61 Co (cumulative) and nat Fe(d,x) 53 Fe, 48 V (cumulative). The results were compared with literature data, the TENDL-2023 database, and default theoretical calculations from the TALYS-2.04, CoH-3.6.0, EMPIRE 3.2.3, and ALICE-2020 reaction modeling codes. Here, this work presents another example of the lack of predictive capabilities for this set of modern nuclear-reaction modeling codes, and highlights the unsatisfactory modeling of experimental cross sections. Experimental data are important to improve the codes in general, and new experimental results can be used to improve the models. Finally, this measurement has revealed the need for an updated evaluation of the nat Cu(d,x) 63 Zn deuteron monitor reaction.

193mPt↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

Preemptive optimization of a clinical antibody for broad neutralization of SARS-CoV-2 variants and robustness against viral escape

Most previously authorized clinical antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have lost neutralizing activity to recent variants due to rapid viral evolution. To mitigate such escape, we preemptively enhance AZD3152, an antibody authorized for prophylaxis in immunocompromised individuals. Using deep mutational scanning (DMS) on the SARS-CoV-2 antigen, we identify AZD3152 vulnerabilities at antigen positions F456 and D420. Through two iterations of computational antibody design that integrates structure-based modeling, machine-learning, and experimental validation, we co-optimize AZD3152 against 24 contemporary and previous SARS-CoV-2 variants, as well as 20 potential future escape variants. Our top candidate, 3152-1142, restores full potency (100-fold improvement) against the more recently emerged XBB.1.5+F456L variant that escaped AZD3152, maintains potency against previous variants of concern, and shows no additional vulnerability as assessed by DMS. This preemptive mitigation demonstrates a generalizable approach for optimizing existing antibodies against potential future viral escape.

59 BASIC BIOLOGICAL SCIENCES↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗