Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPRESSORS - RADIAL FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Experimental investigation of the performance of a supersonic compressor cascade

Supersonic cascade wind tunnel results are presented for a linear, supersonic compressor cascade derived from the near-tip section of a high-throughflow axial flow compressor rotor over the inlet Mach number range of 1.30-1.71. Laser anemometry was used to obtain flow-velocity measurements showing the wave pattern in the entrance region. Attention is given to the unique-incidence relationship for this cascade, which relates the supersonic inlet Mach number to the inlet flow direction. An empirical correlation is obtained for the influence of the independent parameters of back pressure, axial velocity density ratio, and blade element performance.

Tweedt, T. L.↗

Noise study of single stage compressor rotor-stator interaction

Study made of noise radiation from rotor-stator interaction in axial-flow compressors. The collected data were reduced to the form of radiation patterns and frequency spectra. These data show how the radiation patterns are affected by the relative number of rotor blades and stator vanes.

Copeland, W. L.↗

Altitude-Wind-Tunnel Investigation of a 4000-Pound-Thrust Axial-Flow Turbojet Engine. II - Operational Characteristics: Operational Characteristics - II

An investigation was conducted in the Cleveland altitude wind tunnel to determine the operational characteristics of an axial flow-type turbojet engine with a 4000-pound-thrust rating over a range of pressure altitudes from 5,000 to 50,OOO feet, ram pressure ratios from 1.00 to 1.86, and temperatures from 60 deg to -50 deg F. The low-flow (standard) compressor with which the engine was originally equipped was replaced by a high-flow compressor for part of the investigation. The effects of altitude and airspeed on such operating characteristics as operating range, stability of combustion, acceleration, starting, operation of fuel-control systems, and bearing cooling were investigated. With the low-flow compressor, the engine could be operated at full speed without serious burner unbalance at altitudes up to 50,000 feet. Increasing the altitude and airspeed greatly reduced the operable speed range of the engine by raising the minimum operating speed of the engine. In several runs with the high-flow compressor the maximum engine speed was limited to less than 7600 rpm by combustion blow-out, high tail-pipe temperatures, and compressor stall. Acceleration of the engine was relatively slow and the time required for acceleration increased with altitude. At maximum engine speed a sudden reduction in jet-nozzle area resulted in an immediate increase in thrust. The engine started normally and easily below 20,000 feet with each configuration. The use of a high-voltage ignition system made possible starts at a pressure altitude of 40,000 feet; but on these starts the tail-pipe temperatures were very high, a great deal of fuel burned in and behind the tail-pipe, and acceleration was very slow. Operation of the engine was similar with both fuel regulators except that the modified fuel regulator restricted the fuel flow in such a manner that the acceleration above 6000 rpm was very slow. The bearings did not cool properly at high altitudes and high engine speeds with a low-flow compressor, and bearing cooling was even poorer with a high-flow compressor.

Fleming, William A.↗

Similarity analysis of compressor tip clearance flow structure

A new approach is presented for analyzing compressor tip clearance flow. The basic idea is that the clearance velocity field can be (approximately) decomposed into independent throughflow and crossflow, since chordwise pressure gradients are much smaller than normal pressure gradients in the clearance region. As in the slender body approximation in external aerodynamics, this description implies that the three-dimensional steady clearance flow can be viewed as a two-dimensional, unsteady flow. Using this approach, a similarity scaling for the crossflow in the clearance region is developed and a generalized description of the clearance vortex is derived. Calculations based on the similarity scaling agree well with a wide range of experimental data in regard to flow features such as crossflow velocity field, static pressure field, and tip clearance vortex trajectory.

Chen, G. T.↗

Passive Controls of Tip Clearance Flow in A Transonic Compressor for Stall Margin Improvement: Common Flow Physics

Two passive tip clearance control devices for stall margin improvement in a transonic compressor are compared in detail. The primary objective of the current study is to examine the overall performance in terms of stall margin increase and any associated performance penalties near design operation with axial casing grooves (ACGs)and circumferential casing grooves (CCGs). The underlying flow physics of these passive flow control devices are examined and compared to identify any relative advantages in the development of optimized casing treatment designs.

compressor↗

Data for Design of Entrance Vanes from Two-Dimensional Tests of Airfoils in Cascade

As a part of a program of the NACA directed toward increasing the efficiency of compressors and turbines, data were obtained for application to the design of entrance vanes for axfax-flow compressors or turbines. A series of blower-blade sections with relatively high critical speeds have been developed for turning air efficiently from 0 deg to 80 deg starting with an axial direction. Tests were made of five NACA 65-series blower blades (modified NACA 65(216)-010 airfoils) and of four experimentally designed blower blades in a stationary cascade at low Mach numbers. The turning effectiveness and the pressure distributions of these blade sections at various angles of attack were evaluated over a range of solidities near 1. Entrance-vane design charts are presented that give a blade section and angle of attack for any desired turning angle. The blades thus obtained operate with peak-free pressure distributions. Approximate critical Mach numbers were calculated from the pressure distributions.

FLOW-VANES, GUIDE↗

Calculated effects of turbine rotor-blade cooling-air flow, altitude, and compressor bleed point on performance of a turbojet engine

Effects of air-cooling turbine rotor blades on performance of a turbojet engine were calculated for a range of altitudes from sea level to 40,000 feet and a range of coolant flows up to 3 percent of compressor air flow, for two conditions of coolant bleed from the compressor. Bleeding at required coolant pressure resulted in a sea-level thrust reduction approximately twice the percentage coolant flow and in an increase in specific fuel consumption approximately equal to percentage coolant flow. For any fixed value of coolant flow ratio the percentage thrust reduction and percentage increase in specific fuel consumption decreased with altitude. Bleeding coolant at the compressor discharge resulted in an additional 1 percent loss in performance at sea level and in smaller increase in loss of performance at higher altitudes.

TURBINE COOLING↗

The role of fluctuating forces in the generation of compressor noise

The results of a theoretical and experimental study on the role of aerodynamically-induced fluctuating forces in the sound generation by axial-flow compressors are presented. Analytical models for the generation and radiation of sound by rotor/stator combinations were developed. For the experimental substantiation of the analytical results, the technology was developed to measure fluctuating forces directly on rotating airfoils using miniature differential-pressure sensors and FM telemetry. Under the assumption of full coherence of the force field on the blade, radiated sound power was predicted from the force measurements on blades and compared with measured sound power. Both broadband radiation from a single rotating airfoil and discrete frequency radiation due to interaction of multi-bladed stator/rotor configurations were investigated. The results indicate the necessity to obtain information on the details of the force field for accurate prediction of the radiated sound spectrum.

Heller, H. H.↗

Effect of Angle of Incidence of Second-Stage Vane Assembly on Third-Stage Compressor-Blade Vibration and Engine Performance

Strain-gages were used to measure blade vibrations causing failures in the third stage of a production 11-stage axial-flow compressor. After the serious third-stage vibration was detected, a series of investigations were conducted with second-stage vane assemblies of varying angles of incidence. Curves presented herein show the effect of varying the angle of incidence of second-stage vane assembly on third-stage rotor-blade vibration amplitude and engine performance. A minimum vibration amplitude was obtained without greatly affecting the engine performance with a second-stage vane assembly of 9deg. greater angle of incidence than the assembly normally furnished with the engine.

Meyer, Andre J., Jr.↗

Flow Physics at a Large Rotor Tip Gap in a Multi-Stage Axial Compressor

The flow physics in a large rotor tip gap in a 1.5-stage axial compressor is investigated in the current study. The flow structure in the rotor tip region is complex with several dominant vortical structures of opposite rotation, resulting in inhomogeneous and highly anisotropic turbulence. Earlier measurements show that eddy viscosity is negative over large parts of the tip region and eddy viscosity varies among stress/strain components. The present study aims to understand how the complex nature of rotor tip leakage flow affects compressor performance when the tip gap size is greater than 4–5% of the rotor span, which is typical of advanced small core engines. Unsteady Reynolds-averaged Navier-Stokes (URANS) and Large Eddy Simulation (LES) techniques are applied to study flow physics in a large rotor tip gap (5.5% of rotor span) in a 1.5-stage axial compressor. Calculated flow fields from the two different approaches are compared with available measurements and examined in detail. LES calculates the pressure rise in the present compressor fairly well, while URANS with a standard two-equation turbulence closure underpredicts the pressure rise by 15-20% of the measured values. The current study shows that URANS with the current turbulence closure produces much higher all-positive eddy viscosity in the tip-gap region compared to measurements and LES. The distribution of eddy viscosity in the URANS simulation is also wrong. Consequently, the flow in the tip region is highly damped with significantly larger blockage generation, which results in the tip leakage vortex (TLV) staying closer to the blade suction side compared to the measurement. When the TLV stays closer to the blade, both flow turning and the pressure rise across the compressor are reduced compared to the measurements. It appears that this effect is amplified by a large rotor tip gap.

tip gap↗

A Model to Assess the Risk of Ice Accretion Due to Ice Crystal Ingestion in a Turbofan Engine and its Effects on Performance

The occurrence of ice accretion within commercial high bypass aircraft turbine engines has been reported under certain atmospheric conditions. Engine anomalies have taken place at high altitudes that were attributed to ice crystal ingestion, partially melting, and ice accretion on the compression system components. The result was one or more of the following anomalies: degraded engine performance, engine roll back, compressor surge and stall, and flameout of the combustor. The main focus of this research is the development of a computational tool that can estimate whether there is a risk of ice accretion by tracking key parameters through the compression system blade rows at all engine operating points within the flight trajectory. The tool has an engine system thermodynamic cycle code, coupled with a compressor flow analysis code, and an ice particle melt code that has the capability of determining the rate of sublimation, melting, and evaporation through the compressor blade rows. Assumptions are made to predict the complex physics involved in engine icing. Specifically, the code does not directly estimate ice accretion and does not have models for particle breakup or erosion. Two key parameters have been suggested as conditions that must be met at the same location for ice accretion to occur: the local wet-bulb temperature to be near freezing or below and the local melt ratio must be above 10%. These parameters were deduced from analyzing laboratory icing test data and are the criteria used to predict the possibility of ice accretion within an engine including the specific blade row where it could occur. Once the possibility of accretion is determined from these parameters, the degree of blockage due to ice accretion on the local stator vane can be estimated from an empirical model of ice growth rate and time spent at that operating point in the flight trajectory. The computational tool can be used to assess specific turbine engines to their susceptibility to ice accretion in an ice crystal environment.

Jorgenson, Philip C. E.↗

Generalized Fluid System Simulation Program (GFSSP) - Version 6

The Generalized Fluid System Simulation Program (GFSSP) is a finite-volume based general-purpose computer program for analyzing steady state and time-dependent flow rates, pressures, temperatures, and concentrations in a complex flow network. The program is capable of modeling real fluids with phase changes, compressibility, mixture thermodynamics, conjugate heat transfer between solid and fluid, fluid transients, pumps, compressors, flow control valves and external body forces such as gravity and centrifugal. The thermo-fluid system to be analyzed is discretized into nodes, branches, and conductors. The scalar properties such as pressure, temperature, and concentrations are calculated at nodes. Mass flow rates and heat transfer rates are computed in branches and conductors. The graphical user interface allows users to build their models using the 'point, drag, and click' method; the users can also run their models and post-process the results in the same environment. The integrated fluid library supplies thermodynamic and thermo-physical properties of 36 fluids, and 24 different resistance/source options are provided for modeling momentum sources or sinks in the branches. Users can introduce new physics, non-linear and time-dependent boundary conditions through user-subroutine.

Majumdar, Alok↗

Transient performance of fan engine with water ingestion

In a continuing investigation on effects of rain-water ingestion into bypass fan engines, it is shown that the performance of axial-flow compressors and fans is fundamentally time-dependent during ingestion of water. A code named WINCOF-I has been developed for establishing the performance of axial-flow turbomachinery operating with air-water vapor-water droplet-water film mixture, Illustrative examples of predictions and effects are provided for the case of the air-compression system of a generic bypass fan engine. Utilizing performance maps so-generated, the effects of water ingestion into the generic engine have been determined under test cell conditions simulating ingestion, flight operation (altitude and flight Mach number), and power-demand setting.

Murthy, S. N. B.↗

Experimental investigation of the performance of a supersonic compressor cascade

Results are presented from an experimental investigation of a linear, supersonic, compressor cascade tested in the supersonic cascade wind tunnel facility at the DFVLR in Cologne, Federal Republic of Germany. The cascade design was derived from the near-tip section of a high-through-flow axial flow compressor rotor with a design relative inlet Mach number of 1.61. Test data were obtained over a range of inlet Mach numbers from 1.23 to 1.71, and a range of static pressure ratios and axial-velocity-density ratios (AVDR) at the design inlet condition. Flow velocity measurements showing the wave pattern in the cascade entrance region were obtained using a laser transit anemometer. From these measurements, some unique-incidence conditions were determined, thus relating the supersonic inlet Mach number to the inlet flow direction. The influence of static pressure ratio and AVDR on the blade passage flow and the blade-element performance is described, and an empirical correlation is used to show the influence of these two (independent) parameters on the exit flow angle and total-pressure loss for the design inlet condition.

Tweedt, D. L.↗

Efficient laser anemometer for intra-rotor flow mapping in turbomachinery

A fringe type laser anemometer is described. Features of the anemometer include; a rapid and efficient data acquisition process; a detailed real time graphic display of the data being accumulated; and input laser beam positioning that maximizes the size of the intrarotor region being mapped. Results are presented that demonstrate the anemometer's capability in flow mapping within a transonic axial flow compressor rotor. A velocity profile, derived from 30,000 measurements along 1000 sequential circumferential positions covering 20 blade passages, was obtained in 30 seconds. The use of fluorescent seed particles allowed flow measurements near the rotor hub and the casing window.

Powell, J. A.↗

Advanced two-stage compressor program design of inlet stage

The aerodynamic design of an inlet stage for a two-stage, 10/1 pressure ratio, 2 lb/sec flow rate compressor is discussed. Initially a performance comparison was conducted for an axial, mixed flow and centrifugal second stage. A modified mixed flow configuration with tandem rotors and tandem stators was selected for the inlet stage. The term conical flow compressor was coined to describe a particular type of mixed flow compressor configuration which utilizes axial flow type blading and an increase in radius to increase the work input potential. Design details of the conical flow compressor are described.

Bryce, C. A.↗

Analysis of the Honeywell Uncertified Research Engine with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to provide operating conditions such that ice would accrete in either the fan-stator through the inlet guide vane region of the compression system or within the first stator of the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDESMELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan-stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet-bulb temperature thresholds were applied for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applied to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions. The goal of this study is to show that the computational process developed on earlier engine icing tests can be used to provide an icing risk assessment in adiabatic regions for other engines.

Turbofan engine↗

Analysis of the Honeywell Uncertified Research Engine (HURE) with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to have ice accrete in two regions of the compression system: region one, which consists of the fan-stator through the inlet guide vane (IGV), and region two which is the first stator within the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDES-MELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan-stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet bulb temperature thresholds were applicable for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applicable to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions.

Veres, Joseph P.↗