Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONCENTRATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Equilibrium concentrations of N2H4 and its decomposition products at elevated temperatures and pressures

Liquid hydrazine is considered as a convenient source of hydrogen rather than just as a rocket fuel. For such purposes, the hydrogen is usually obtained by passing the hydrazine through a heated catalytic bed. One convenient measure of the effectiveness of a catalytic decomposition device as a whole is to compare the quantity of hydrogen produced with the equilibrium concentration of the gaseous species N2H4, NH3, N3, and H2 which would exist at the temperature and pressure found in various parts of the device. Calculations of the concentrations were carried out and are reported here. Following presentation of the results in both tabular and graphical forms is a comparison between the computed equilibrium concentrations and available experimental data.

Smetana, F. O.↗

Upper atmospheric dust concentrations in polar regions.

Investigation of dust concentrations in the upper atmosphere at the polar regions by sounding rocket flights. The results indicate no normal existence of high concentration of dust and show no variation in the concentration of particles in the upper atmosphere as a function of the time of day.

Ferry, G. V.↗

Large ion concentration gradients below the equatorial F peak.

Very large vertical and longitudinal gradients in the ion concentrations are observed below the F peak near the magnetic equator with the retarding potential analyzer on Ogo 6. Ion concentration 'bite outs' of up to a factor of 1000 are observed above 400 km. They appear to be associated with the bottomside of the nighttime F layer. The ion composition in the minima may contain large fractions of ions heavier than O(+) (e.g., NO(+) and Fe(+)). It is suggested that convective electric fields associated with spread F steepen the bottomside of the F layer and also introduce longitudinal irregularities in the vertical ion concentration profiles.

Hanson, W. B.↗

Partial equilibrium model for predicting concentration of CO in combustion

A simple kinetic model, based upon the concept of partial equilibrium, is developed for predicting carbon monoxide concentrations in such steady-flow hydrocarbon-air combustion systems as gas-turbine combustors. The only two kinetic constraints used in the model are on the rate of change of the total number of gaseous particles in the system, and on the rate of change of the CO concentration. The accuracy of the model is verified by comparison with experimental results obtained by burning kerosene with air in a 130,000 Btu/hr atmospheric-pressure steady-flow burner. Burnt-gas cooling rates of 1,000,000 K/sec, about the magnitude encountered in the dilution zone of gas-turbine combustors, were obtained with a compact water-cooled heat exchanger. Good agreement between measured CO concentrations and the values predicted by the partial-equilibrium model was obtained.

Morr, A. R.↗

Gas sampling method for determining pollutant concentrations in the flame zone of two swirl-can combustor modules

A gas sampling probe and traversing mechanism were developed to obtain detailed measurements of gaseous pollutant concentrations in the primary and mixing regions of combustors in order to better understand how pollutants are formed. The gas sampling probe was actuated by a three-degree-of-freedom traversing mechanism and the samples obtained were analyzed by an on-line gas analysis system. The pollutants in the flame zone of two different swirl-can combustor modules were measured at an inlet-air temperature of 590 K, pressure of 6 atmospheres, and reference velocities of 23 and 30 meters per second at a fuel-air ratio of 0.02. Typical results show large spatial gradients in the gaseous pollutant concentration close to the swirl-can module. Average concentrations of unburned hydrocarbons and carbon monoxide decrease rapidly in the downstream wake regions of each module. By careful and detailed probing, the effect of various module design features on pollutant formation can be assessed. The techniques presently developed seem adequate to obtain the desired information.

Duerr, R. A.↗

Regular expansion solutions for small Peclet number heat or mass transfer in concentrated two-phase particulate systems

Steady state heat or mass transfer in concentrated ensembles of drops, bubbles or solid spheres in uniform, slow viscous motion, is investigated. Convective effects at small Peclet numbers are taken into account by expanding the nondimensional temperature or concentration in powers of the Peclet number. Uniformly valid solutions are obtained, which reflect the effects of dispersed phase content and rate of internal circulation within the fluid particles. The dependence of the range of Peclet and Reynolds numbers, for which regular expansions are valid, on particle concentration is discussed.

Yaron, I.↗

Investigation of terrestrial photovoltaic power systems with sunlight concentration

An analytical model of the silicon solar cells for high illumination is being used to design cells for different concentration factors. It is shown that a cell design using one centimeter length grid fingers would have an efficiency at 100 suns that is 90% of the efficiency of a typical cell at one sun. This may require about 30 fingers per centimeter. A decrease in efficiency comes from the greater coverage of the surface with grids as the concentration increases. The importance of base material resistivity on cell design for high concentration is outlined.

Backus, C. E.↗

Zinc depolarized electrochemical CO2 concentration

Two zinc depolarized electrochemical carbon dioxide concentrator concepts were analytically and experimentally evaluated for portable life support system carbon dioxide (CO2) removal application. The first concept, referred to as the zinc hydrogen generator electrochemical depolarized CO2 concentrator, uses a ZHG to generate hydrogen for direct use in an EDC. The second concept, referred to as the zinc/electrochemical depolarized concentrator, uses a standard EDC cell construction modified for use with the Zn anode. The Zn anode is consumed and subsequently regenerated, thereby eliminating the need to supply H2 to the EDC for the CO2 removal process. The evaluation was based primarily on an analytical evaluation of the two ZnDCs at projected end item performance and hardware design levels. Both ZnDC concepts for PLSS CO2 removal application were found to be noncompetitive in both total equivalent launch weight and individual extravehicular activity mission volume when compared to other candidate regenerable PLSS CO2 scrubbers.

Woods, R. R.↗

Experiments on solar photovoltaic power generation using concentrator and liquid cooling

Calculations and experimental data are presented leading to the development of a practical, economical solar photovoltaic power supply. The concept involves concentration of sunlight up to about 100 times normal solar intensity in a solar tracking collector and directing this to an array of solar cells. The cells are immersed in water circulated from a thermal reservoir which limits cell temperature rise to about 20 C above ambient during the day and which cools to ambient temperature during the night. Experiments were conducted on solar cells using a Fresnel lens for magnification, a telescope equatorial mount with clock drive, and tap water circulated through the solar cell holder cavity. Test results show that cells operate satisfactorily under these conditions. Power outputs achieved experimentally with cell optimized for 25 suns were linear with concentration to about 15 suns. Cells optimized for 100 suns were not available, but a corresponding linear relation of power output with concentration is anticipated. Test results have been used in a design analysis of the cost of systems utilizing this technique.

Beam, B. H.↗

An ultraviolet video technique for visualization of stack plumes and for measuring sulfur dioxide concentration and effluent velocity

Absorption spectroscopy utilizing a video sensing technique was investigated as a means of visualizing SO2 in power plant stack plumes and for measuring SO2 concentration and effluent velocity in these plumes. The absorption of SO2 is measured in the ultraviolet region by using the sky as a background source. An additional spectral channel is used to correct for particulate scattering encountered in coal fired power plant plumes. The video system also tracks fluctuations in the SO2 concentration which leads to the determination of an eddy convection velocity. Field measurements were performed to show that the eddy convection velocity is proportional to the average in-stack velocity and to empirically determine their relationship. It was concluded that the video absorption technique is an attractive method for remotely determining both SO2 concentration and plume velocity with the same instrument.

Exton, R. J.↗

Apparent lethal concentrations of pyrolysis products of some polymeric materials

Thirty-nine samples of polymeric materials were evaluated to determine the apparent lethal concentrations of their pyrolysis products. The materials were compared on the basis of the apparent lethal concentration for 50 percent of the test animals. Relative toxicity rankings based o apparent lethal concentration values can differ significantly depending on whether they are based on weight of sample charged or weight of sample pyrolyzed. The ranking of polyphenylene sulfide is particularly sensitive to this difference.

Hilado, C. J.↗

Effect of temperature and heating rate on apparent lethal concentrations of pyrolysis products

The apparent lethal concentrations for 50 percent of the test animals of the pyrolysis products from twelve polymeric materials were studied as a function of temperature and heating rate. The materials were polyethylene, nylon 6, ABS, polycarbonate, polyether sulfone, polyaryl sulfone, wool fabric, aromatic polyamide fabric, polychloroprene foam, polyvinyl fluoride film, Douglas fir, and red oak. The apparent lethal concentration values of most materials vary significantly with temperature and heating rate. The apparent lethal concentration values, based on weight of sample charged, appears to effectively integrate the thermophysical, thermochemical, and physiological responses from a known quantity of material under specified imposed conditions.

Hilado, C. J.↗

Does application of the Rosiwal Principle to lunar soils require that concentrations of solar-wind-implanted species be grain-size independent

A reconsideration of the application of the Rosiwal Principle to lunar soils indicates a flaw in arguments put forth previously by Criswell (1975). Specifically, by introducing a boundary condition which must exist at the lunar surface, it is shown that concentrations of solar-wind-implanted species showing a dependence on grain size may be able to develop in soils at concentration levels below those required for saturation of grain surfaces. As a result, observed grain-size-dependent concentrations of solar-wind species in lunar soils do not necessarily require the exposure time scales or solar-wind fluxes deduced from the arguments of Criswell.

Becker, R. H.↗

An experiment to measure variations in nighttime E-region neutral concentration

An experimental procedure is demonstrated which holds promise for the nighttime measurement of ion-neutral collision frequencies or net neutral concentration in the E-region by combining incoherent scatter data with appropriate photometric measurements. Data illustrating the technique are applied to comparing relative variations in atomic oxygen concentrations (from the E-region component of the O I 5577 A emission) near 100 km to those in the net neutral concentration obtained from combined incoherent scatter data and neutral temperature data extracted from Fabry-Perot measurement of the O I 5577 A line profile.

Cogger, L. L.↗

Prediction of hydrodynamics and chemistry of confined turbulent methane-air frames in a two concentric tube combustor

A formulation of the governing partial differential equations for fluid flow and reacting chemical species in a two-concentric-tube combustor is presented. A numerical procedure for the solution of the governing differential equations is described and models for chemical-equilibrium and chemical-kinetics calculations are presented. The chemical-equilibrium model is used to characterize the hydrocarbon reactions. The chemical-kinetics model is used to predict the concentrations of the oxides of nitrogen. The combustor considered consists of two coaxial ducts. Concentric streams of gaseous fuel and air enter the inlet duct at one end; the flow then reverses and flows out through the outer duct. Two sample cases with specified inlet and boundary conditions are considered and the results are discussed.

Markatos, N. C.↗

An analytical and experimental investigation of a 1.8 by 3.7 meter Fresnel lens solar concentrator

Line-focusing acrylic Fresnel lenses with application potential in the 200-370 C range are being analytically and experimentally investigated. The measured solar concentration characteristics of a 1.8 by 3.7 m lens and its utilization in a solar collection mode are summarized in this paper. A peak concentration ratio of 64 with 90% of the transmitted energy focused into a 5 cm width was achieved and demonstrated the feasibility of the Fresnel lens solar concentrator concept.

Hastings, L. J.↗

Flat-sided rectilinear trough as a solar concentrator - An analytical study

Formulas are derived for the concentration factor and irradiance distribution at the base of the flat-sided linear trough. Performance is affected by the number of reflections the solar rays undergo before reaching the base, the cone apex angle, and the coefficient of reflection. Results are presented graphically in such a way that one can choose the optimum configuration, which is the minimum material required, to achieve a given concentration factor. Practical concentration factors range from 1.5 to 4 depending on the geometry and coefficient of reflection.

Burkhard, D. G.↗