At least 343 records · Page 19

Advanced oxide dispersion strengthened sheet alloys for improved combustor durability

Burner design modifications that will take advantage of the improved creep and cyclic oxidation resistance of oxide dispersion strengthened (ODS) alloys while accommodating the reduced fatigue properties of these materials were evaluated based on preliminary analysis and life predictions, on construction and repair feasibility, and on maintenance and direct operating costs. Two designs - the film cooled, segmented louver and the transpiration cooled, segmented twin Wall - were selected for low cycle fatigue (LCF) component testing. Detailed thermal and structural analysis of these designs established the strain range and temprature at critical locations resulting in predicted lives of 10,000 cycles for MA 956 alloy. The ODs alloys, MA 956 and HDA 8077, demonstrated a 167 C (300 F) temperature advantage over Hastelloy X alloy in creep strength and oxidation resistance. The MA 956 alloy was selected for mechanical property and component test evaluations. The MA 956 alloy was superior to Hastelloy X in LCF component testing of the film cooled, segmented louver design.

Henricks, R. J.↗

Zero-g experiments with a He II active phase separator for space application

An active phase separator (APS) for temperature control of He II space cooling systems was tested in a zero-g environment during a series of parabolic flights on a NASA KC 135 aircraft. The APS provides for liquid-gas separation and features an annular gap, a downstream heat exchanger and an upstream ball closure. The apparatus was operated during acceleration and floating and in two different heat load situations. The tests confirmed that adequate mass flow rates could be maintained using a vacuum pump to simulate space vacuum and that residual liquid could be evaporated from the heat exchanger after closing a ball valve to seal off flows.

Denner, H. D.↗

Local heat transfer augmentation in channels with two opposite ribbed surfaces

The local heat transfer coefficient distribution of a square channel with two opposite ribbed walls was determined. The square channel was connected to a sudden contraction entrance in order to simulate the inlet condition of the turbine blade cooling passages. The test channel was heated by thin stainless steel foils with a thickness of 0.000025 m, and instrumented with 180 thermocouples. The brass ribs of a square cross-section were glued periodically, in line, onto the top and bottom walls of the foil-heated channel in patterns to achieve the desired spacing and angle-of-attack. The local heat transfer coefficients on the smooth side and the ribbed side walls, at the channel entrance and the downstream regions, were measured for eight rib configurations and three Reynolds numbers (Re = 10,000, 30,000, and 60,000).

Han, J. C.↗

OTVE combustor wall condition monitoring

Conventional ultrasonics, eddy current, and electromagnetic acoustic transduction (EMAT) technologies were evaluated to determine their capability of measuring wall thickness/wear of individual cooling channels in test specimens simulating conditions in the throat region of an OTVE combustion chamber liner. Quantitative results are presented for the eddy current technology, which was shown to measure up to the optimum 20-mil wall thickness with near single channel resolution. Additional results demonstrate the capability of the conventional ultrasonics and EMAT technologies to detect a thinning or cracked wall. Recommendations for additional eddy current and EMAT development tests are presented.

Szemenyei, Brian↗

Cryogenic optical tests of a lightweight HIP beryllium mirror

Five interferometric tests were conducted at cryogenic temperatures on a lightweight, 50 cm diameter, hot isostatic pressed (HIP) beryllium mirror in the Ames Research Center (ARC) Cryogenic Optics Test Facility. The purpose of the tests was to determine the stability of the mirror's figure when cooled to cryogenic temperatures. Test temperatures ranged from room ambient to 8 K. One cycle to 8 K and five cycles to 80 K were performed. Optical and thermal test methods are described. Data is presented to show the amount of cryogenic distortion and hysteresis present in the mirror when measured with an earlier, Shack interferometer, and with a newly-acquired, phase-measuring interferometer.

Melugin, Ramsey K.↗

Cool infalling gas and its interaction with the hot ISM of elliptical galaxies

The authors describe work leading to the suggestion that interaction between infalling cool gas and ambient hot, coronal plasma in elliptical galaxies is responsible for emission filaments, and might remove the need for large mass depositions in cooling flows. A test of the hypothesis is undertaken - the run of surface brightness with radius for the emission lines - and the prediction agrees well with the data.

Sparks, W. B.↗

A unique high heat flux facility for testing hypersonic engine components

This paper describes the Hot Gas Facility, a unique, reliable, and cost-effective high-heat-flux facility for testing hypersonic engine components developed at the NASA Lewis Research Center. The Hot Gas Facility is capable of providing heat fluxes ranging from 200 Btu/sq ft per sec on flat surfaces up to 8000 Btu/sq ft per sec at a leading edge stagnation point. The usefulness of the Hot Gas Facility for the NASP community was demonstrated by testing hydrogen-cooled structures over a range of temperatures and pressures. Ranges of the Reynolds numbers, Prandtl numbers, enthalpy, and heat fluxes similar to those expected during hypersonic flights were achieved.

Melis, Matthew E.↗

The Grain Structure of Castings: Some Aspects of Modelling

The efficacy of the modelling of the solidification of castings is typically tested against observed cooling curves and the final grain structures and sizes. Without thermo solutal convection, equiaxed grain formation is promoted by introduction of heterogeneous substrates into the melt, as grain refiners. With efficient thermo solutal convection, dendrite fragments from the mushy zone can act as an intrinsic source of equiaxed grains and resort to grain refining additions is unnecessary. The mechanisms of dendrite fragmentation and transport of these fragments are briefly considered.

Hellawell, A.↗

Novel Cryogenic Insulation Materials: Aerogel Composites

New insulation materials are being developed to economically and reliably insulate future reusable spacecraft cryogenic tanks over a planned lifecycle of extreme thermal challenges. These insulation materials must prevent heat loss as well as moisture and oxygen condensation on the cryogenic tanks during extended groundhold, must withstand spacecraft launch conditions, and must protect a partly full or empty reusable cryogenic tank from significant reentry heating. To perform over such an extreme temperature range, novel composites were developed from aerogels and high-temperature matrix material such as Space Shuttle tile. These materials were fabricated and tested for use both as cryogenic insulation and as high-temperature insulation. The test results given in this paper were generated during spacecraft re-entry heating simulation tests using cryogenic cooling.

White, Susan↗

An Assessment of NASA Glenn's Aeroacoustic Experimental and Predictive Capabilities for Installed Cooling Fans

Quiet, high performance electronics cooling fans are needed for both commercial applications and future manned space exploration missions. Researchers at NASA Glenn focusing on aircraft engine noise, have long been familiar with the challenge of reducing fan noise without sacrificing aerodynamic performance. Is it possible to capitalize on the lessons-learned in aircraft engine noise reduction to identify inexpensive ways to improve the aerodynamic and acoustic performance of electronics cooling fans? Recent tests at NASA Glenn have begun to look for answers to this question. The overall aerodynamic and acoustic performance of a commercially available, spaceflight qualified 80 mm diameter axial flow fan has been measured using an automated plenum in accordance with ISO 10302 in the hemi-anechoic chamber of NASA Glenn s Acoustical Testing Laboratory. These measurements are complemented by detailed aerodynamic measurements of the inlet, exhaust, and rotor wake regions of the fan using Particle Image Velocimetry and hot-wire probes. A study of preliminary results yielded recommendations for system designers, fan manufacturers, and researchers.

Koch, L. Danielle↗

Design and Fabrication of a Tank-Applied Broad Area Cooling Shield Coupon

The small-scale broad area cooling (BAC) shield test panel represents a section of the cryogenic propellant storage and transfer ground test article, a flight-like cryogenic propellant storage tank. The test panel design includes an aluminum tank shell, primer, spray-on foam insulation, multilayer insulation (MLI), and BAC shield hardware. This assembly was sized to accurately represent the character of the MLI/BAC shield system, be quickly and inexpensively assembled, and be tested in the Marshall Space Flight Center Acoustic Test Facility. Investigating the BAC shield response to a worst-case launch dynamic load was the key purpose for developing the test article and performing the test. A preliminary method for structurally supporting the BAC shield using low-conductivity standoffs was designed, manufactured, and evaluated as part of the test. The BAC tube-standoff interface and unsupported BAC tube lengths were key parameters for evaluation. No noticeable damage to any system hardware element was observed after acoustic testing.

Wood, J. J.↗

Characterization of Flat-Plate Heat Pipe Functionality for Fuel Cell Application

For many exothermic systems such as proton exchange membrane (PEM) fuel cells, cooling is necessary to maintain consistent and uniform operating temperatures which are generally in the range of 60 to 80°C. A potential solution is a heat pipe employing the principle of conduction in combination with a phase change. The purpose of this study was to fully characterize the operation of a heat pipe with unique geometry designed for fuel cell heat removal at operating temperatures up to 100°C and to assess the suitability of the resulting performance for cooling system integration. Test variables consist of cold sink thermal contact conductance coefficient improving material usage, heat rejection temperature, contact pressure and area, heat pipe orientation, operational hours, and variability between units. The test results showed that heat pipe performance improves through increased condenser and heat sink contact pressure, thermal contact coating usage, greater condenser area utilization, and colder heat sink temperature. Higher initial heat pipe temperature and greater age or operation time reduce the heat pipe capabilities. Placing the condenser lower than the evaporator is the only heat pipe orientation that affects evaporator plate temperature. Condensing fluid in the lower section reduces heat transfer capacity as that orientation requires liquid water to transport by wicking against gravity.

Smith, Phillip J.↗

Exploring Cryogenic Propellant Behavior in Low-Gravity Environments, Insights from the Saturn AS-203 Vent Experiments and CFD Analysis

In the 1960s, NASA embarked on a series of groundbreaking flight tests on the Saturn AS-203, aiming to understand the complex dynamics of propellants in the distinctive low-gravity lunar environment. These tests centered on venting experiments, subjecting cryogenic liquid hydrogen to conditions beneath its saturation pressure while accelerating the vehicle to manage the propellant's positioning. During these experiments, NASA meticulously scrutinized the propellant tank using a suite of instruments, including temperature and pressure sensors, as well as a camera placed internal to the liquid hydrogen tank. The outcomes provided anecdotal evidence revealing the phenomenon of boiling along the tank's walls and the intriguing formation of liquid globules and droplets in the ullage during the venting process. Notably, the substantial drop in liquid temperature during these tests suggests adiabatic cooling as liquid hydrogen evaporates. This evaporation leads to a cooling of the remaining hydrogen due to the heat it releases. This paper presents the outcomes of our initial analysis, wherein CFD models were used to simulate the observed boiling phenomena and the bulk movement of the liquid hydrogen propellant, both qualitatively and quantitatively. The implications of these findings may extend to mission and vehicle designers, providing invaluable insights for crafting more efficient and effective in-space propulsion systems utilizing cryogenic propellant including impacts to vehicle control systems. Understanding propellant behavior under these conditions may better inform GNC teams, ensuring more stable vehicle operations when utilizing cryogenic propellants. This includes essential considerations for cryogenic propellant transfer and storage systems, integral to NASA's forthcoming Artemis missions. While we recognize the challenges tied to CFD models, this study represents a step forward, highlighting current progress and signaling the potential for refining our predictive understanding in the future.

Computational Fluid Dynamics↗

Exploring Cryogenic Propellant Behavior in Low-Gravity Environments, Insights from the Saturn AS-203 Vent Experiments and CFD Analysis

In the 1960s, NASA embarked on a series of groundbreaking flight tests on the Saturn AS-203, aiming to understand the complex dynamics of propellants in the distinctive low-gravity lunar environment. These tests centered on venting experiments, subjecting cryogenic liquid hydrogen to conditions beneath its saturation pressure while accelerating the vehicle to manage the propellant's positioning. During these experiments, NASA meticulously scrutinized the propellant tank using a suite of instruments, including temperature and pressure sensors, as well as a camera placed internal to the liquid hydrogen tank. The outcomes provided anecdotal evidence revealing the phenomenon of boiling along the tank's walls and the intriguing formation of liquid globules and droplets in the ullage during the venting process. Notably, the substantial drop in liquid temperature during these tests suggests adiabatic cooling as liquid hydrogen evaporates. This evaporation leads to a cooling of the remaining hydrogen due to the heat it releases. This paper presents the outcomes of our initial analysis, wherein CFD models were used to simulate the observed boiling phenomena and the bulk movement of the liquid hydrogen propellant, both qualitatively and quantitatively. The implications of these findings may extend to mission and vehicle designers, providing invaluable insights for crafting more efficient and effective in-space propulsion systems utilizing cryogenic propellant including impacts to vehicle control systems. Understanding propellant behavior under these conditions may better inform GNC teams, ensuring more stable vehicle operations when utilizing cryogenic propellants. This includes essential considerations for cryogenic propellant transfer and storage systems, integral to NASA's forthcoming Artemis missions. While we recognize the challenges tied to CFD models, this study represents a step forward, highlighting current progress and signaling the potential for refining our predictive understanding in the future.

Computational Fluid Dynamics↗

Advanced radial inflow turbine rotor program: Design and dynamic testing

The advancement of small, cooled, radial inflow turbine technology in the area of operation at higher turbine inlet temperature is discussed. The first step was accomplished by designing, fabricating, and subjecting to limited mechanical testing an advanced gas generator rotating assembly comprising a radial inflow turbine and two-stage centrifugal compressor. The radial inflow turbine and second-stage compressor were designed as an integrally machined monorotor with turbine cooling taking place basically by conduction to the compressor. Design turbine inlet rotor gas temperature, rotational speed, and overall gas generator compressor pressure ratio were 1422 K (2560 R), 71,222 rpm, and 10/1 respectively. Mechanical testing on a fabricated rotating assembly and bearing system covered 1,000 cold start/stop cycles and three spins to 120 percent design speed (85,466 rpm).

Rodgers, C.↗

Nondestructive evaluation of regeneratively cooled thrust chambers for rocket engines

Review of a development program for nondestructive tests applicable to hardware with electroformed nickel bonds. The four steps of the program include the selection of some most promising nondestructive evaluation methods out of existing methods, the fabrication of test panels for simulation of cooled thrust chamber walls with bonds of various integrities, the evaluation of the test panels by personnel without previous knowledge of the planned bond integrity, and the verification of actual bond strength in the test panels by destructive tests. Ultrasonics, acoustic emission and holography are evaluated in nondestructive testing applications.

Stauffis, C. R.↗

Experimental Ablation Cooling

The film shows ablation tests on Teflon, nylon, a 27 percent phenolic resin, Haveg Rocketon, and graphite. Teflon hemisphere-shaped and flat face noses were tested with laboratory-scale ceramic-heated, pilot-model ceramic-heated, and electric-arc-powered air jets. Nylon hemisphere-shaped noses were tested with laboratory-scale ceramic-heated and electric-arc-powered air jets. Phenolic resin hemisphere-shaped noses were tested with laboratory-scaled ceramic-heated air jets. Haveg Rocketon and graphite hemisphere-shaped noses were tested with electric-arc-powered air jets.

Cooling↗