Search NASA⌕ Search

SEARCH · Search NASA

Results for “CRYOGENIC TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Measuring higher-order moments of neutron-time-of-flight data for cryogenic inertial confinement fusion implosions on OMEGA

Ion temperatures serve as an important diagnostic for inertial confinement fusion (ICF) implosions. In direct-drive ICF experiments on OMEGA, neutron-time-of-flight (nTOF) data are used to infer the ion temperature of the fusing plasma produced in the implosion experiment. The analysis of the nTOF data requires an assumption about the shape of the underlying source signal. Since the source nTOF signal is a near-replica of the neutron energy spectrum, an ideal Gaussian shape, corresponding to the neutron energy spectrum of a uniform temperature plasma, is routinely employed. However, spatial and temporal variations of the ion temperature in the plasma give rise to higher-order moments, which were first described by Munro [Nucl. Fusion 56, 036001 (2016)]. In this work, we show a simpler alternative analysis to derive moments of the neutron energy spectrum for a plasma with variations in ion temperature. We also present a revised analysis of measured nTOF signals that uses a model with an additional degree of freedom to take into account the effect of ion temperature variations on the shape of the spectrum. Compared to presently used nTOF analysis, the revised analysis yields on average ≈2× more accurate fits to the data and up to 15% higher ion temperatures for cryogenic experiments. As a result, we quantify the ion temperature inflation caused by radially symmetric fluid flows, which are present even in a symmetric implosion, and which serve as a lower bound on the ion temperature inflation in real implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structural analysis of wild-type and Val120Thr mutant Candida boidinii formate dehydrogenase by X-ray crystallography

Candida boidinii NAD + -dependent formate dehydrogenase (CbFDH) has gained significant attention for its potential application in the production of biofuels and various industrial chemicals from inorganic carbon dioxide. The present study reports the atomic X-ray crystal structures of wild-type CbFDH at cryogenic and ambient temperatures, as well as that of the Val120Thr mutant at cryogenic temperature, determined at the Turkish Light Source ‘Turkish DeLight’. The structures reveal new hydrogen bonds between Thr120 and water molecules in the active site of the mutant CbFDH, suggesting increased stability of the active site and more efficient electron transfer during the reaction. Further experimental data is needed to test these hypotheses. Collectively, these findings provide invaluable insights into future protein-engineering efforts that could potentially enhance the efficiency and effectiveness of CbFDH.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a liquid-helium free cryogenic sample holder with mK temperature control for autonomous electron microscopy

The automated and autonomous cryogenic transmission electron microscopy (Cryo-EM) demands a sample holder capable of maintaining temperatures below 10 K with precise control, long holding times, and minimal helium use. Rising to this challenge, we initiated an ambitious project to develop a novel closed-cycle cryocooler-based cryogenic sample holder that operates without the use of liquid helium and the consumption of gaseous helium. Here, this article presents the design, construction, and experimental testing of the initial prototype, which achieves an ultimate temperature of 5.6 K with exceptional stability close to 1mK, while providing a wide temperature control range from 295 K to 5.6 K, marking a clear advancement in cryo-EM holder development. While the prototype was not designed for atomic resolution imaging and thus lacks a sturdy support system to mitigate mechanical vibrations from the cryocooler's pulsed tube, this innovative approach successfully demonstrates proof of concept. It offers unprecedented capabilities for state-of-the-art cryogenic microscopy and microanalysis in materials and biological sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cooperative allostery and structural dynamics of streptavidin at cryogenic- and ambient-temperature

Multimeric protein assemblies are abundant in nature. Streptavidin is an attractive protein that provides a paradigm system to investigate the intra- and intermolecular interactions of multimeric protein complexes. Also, it offers a versatile tool for biotechnological applications. Here, we present two apo-streptavidin structures, the first one is an ambient temperature Serial Femtosecond X-ray crystal (Apo-SFX) structure at 1.7 Å resolution and the second one is a cryogenic crystal structure (Apo-Cryo) at 1.1 Å resolution. These structures are mostly in agreement with previous structural data. Combined with computational analysis, these structures provide invaluable information about structural dynamics of apo streptavidin. Collectively, these data further reveal a novel cooperative allostery of streptavidin which binds to substrate via water molecules that provide a polar interaction network and mimics the substrate biotin which displays one of the strongest affinities found in nature.

60 APPLIED LIFE SCIENCES↗

Phonon-mediated high-voltage detector with background rejection for low-mass dark matter and reactor coherent neutrino scattering experiments

We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov-Trofimov-Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. Furthermore, this new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Validation of a Cryogenic Dilatometer

This project focuses on the design and development of a cryogenic dilatometer capable of measuring the thermal expansion of materials at extremely low temperatures. Understanding how materials change dimension with temperature is critical for applications involving cryogenic environments, particularly laminated systems housing superconducting magnets, where small dimensional changes can significantly affect performance and reliability. To address this, a dilatometer system was designed to operate within a liquid nitrogen environment while accurately measuring displacements caused by thermal contraction. The purpose of this device is to determine the coefficient of thermal expansion (CTE) of a material. The design process involved defining functional requirements, developing mechanical and thermal concepts for the measurement apparatus, selecting appropriate materials compatible with cryogenic temperatures, and integrating sensors capable of detecting small dimensional changes. The resulting system aims to provide a practical and repeatable method for evaluating material thermal expansion at cryogenic temperatures, supporting research into composite use in superconducting applications that require accurate characterization of material behavior in low-temperature environments.

Schmitt, Nicholas [Northern Illinois U.]↗

In Situ Formation of Ripplocations in Hybrid Organic–Inorganic MXenes

Abstract Inorganic–organic hybrid MXenes (h‐MXenes) are a family of 2D transition metal carbides and nitrides functionalized with alkylimido and alkylamido surface groups. Using cryogenic and room temperature scanning transmission electron microscopy (STEM) and electron energy‐loss spectroscopy (EELS), it is shown that ripplocations, a form of a fundamental defect in 2D and layered structures, are abundant in this family of materials. Furthermore, detailed studies of electron probe sample interactions, focusing on structural deformations caused by the electron beam are presented. The findings indicate that at cryogenic temperatures (≈100 K) and below a specific dose threshold, the structure of h‐MXenes remains largely intact. However, exceeding this threshold leads to electron beam‐induced deformation through ripplocations. Interestingly, the deformation behavior, required dose, and resultant structure are highly dependent on temperature. At 100 K, it is demonstrated that the electron beam can induce ripplocations in situ with a high degree of precision.

Chemistry↗

Use of Au@Void@TiO 2 yolk-shell nanostructures to probe the influence of oxide crystallinity on catalytic activity for low-temperature oxidations

A series of Au@Void@TiO 2 yolk-shell structures were synthesized and characterized, and their catalytic activity was tested for the oxidation of carbon monoxide. The target of this study was to evaluate the effects of (1) the crystallinity of the TiO 2 shell and (2) the presence of titanate phases. Transmission electron microscopy and X-ray diffraction data show that increasing calcination temperatures, from 850 to 1250 K, leads to the formation of larger titania crystallites. These crystallites are typically in the form of anatase, but some rutile is also made at high temperatures. The general yolk-shell nanostructures retain their basic characteristics upon calcination and upon treatment with HCl (used to remove the titanate phases), but a few structural and chemical changes do take place: (1) the void-space diameter is reduced by approximately 10% when going from T Calc = 850 K to T Calc = 1250 K, a change that is accompanied by a decrease in the surface area (estimated from N 2 adsorption-desorption isotherms); (2) the shell thickness remains unaffected by either calcination or HCl treatment; (3) the pore volume also remains approximately constant with increasing calcination temperature in the catalysts free of titanates but diminishes significantly in the samples with titanate phases; (4) the mesoporosity is minimal in all yolk-shell nanostructures but more noticeable with the pure TiO 2 shells; (5) the titanates have high Na content (measured by X-ray photoelectron spectroscopy), but that Na is fully removed upon treatment with HCl; (6) no Ti 3+ was detectable in any of the samples, but silica, together with C and (minor amounts of) N, was present in all; (7) all Au is in metallic form; (8) two temperature regimes were observed for the catalytic oxidation of CO, as reported for other similar samples in the past, an Arrhenius regime around or above room temperature, and a cryogenic range going to temperatures as low as 120 K; (9) the latter regime is only seen with the samples containing titanate phases; (10) the titanates seem to also aid in the oxidation at higher temperatures; and (11) in general, increasing titania crystallinity leads to a decrease the catalytic activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature-dependent deformation behavior of a CuZr-based bulk metallic glass composite

In this study, the effect of cryogenic testing temperatures on the deformation behavior of a CuZr-based bulk metallic glass composite (BMGC) has been investigated using in situ high energy X-ray diffraction. The yield strength and work-hardenability of the studied BMGC show an increasing trend from 298 K to 153 K. A higher yield strength at a lower temperature can be attributed to the larger difference in the volume shrinkage between the crystalline phase and the amorphous matrix. The increasing martensitic transformation degree of the crystalline phase from 298 K to 153 K results in the enhanced work-hardenability. These results lead to a better understanding of the temperature dependence of phase-transformation induced plasticity in CuZr-based BMGCs. (C) 2020 Elsevier B.V. All rights reserved.

36 MATERIALS SCIENCE↗

DC Cryogenic Modeling of Open-Source SkyWater 130 nm MOSFETs at 77 K Using BSIM4

Cryogenic applications in high-energy physics (HEP) demand reliable, low-power CMOS electronics capable of operating at liquid nitrogen temperatures (77 K). The open-source SkyWater 130nm (SKY130) CMOS process has previously been shown to operate at temperatures as low as 4 K making it a promising candidate for HEP applications. In this work, we characterize and model SKY130 low-threshold voltage transistors at 77 K, which is a temperature commonly used in modeling applications for liquid argon detectors. DC characteristic measurements were performed at both room temperature and liquid nitrogen temperature. We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K. The resulting model agrees with data at 77 K with an average error on the order of 20% (relative RMS) and shows no dependence on drain voltage. Due to the open-source nature of SKY130, we have made our models publicly available on Github. We hope this work will continue the trend for democratizing circuit design at cryogenic temperatures in high-energy physics by enabling open access to accurate cryogenic CMOS device models at 77 K.

Beall, F. [Texas U., Arlington]↗

Integral Experiment Final Design for Thermal/Epithermal eXperiments (TEX) using Highly Enriched Uranium with Polyethylene at Low Temperature (IER-479 CED-2 Report)

The goal of IER-479 is to design uranium critical experiments that can be used to validate low temperature cross sections and criticality safety analyses over multiple neutron energy regimes. Currently, there are no benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) handbook at temperatures lower than room temperature (International Criticality Safety Benchmark Evaluation Project Handbook, 2019). However, there are many needs for validation of criticality safety analysis at lower temperatures, including meeting transportation requirements and operations conducted outside or in unheated facilities. Additionally, NCSP has funded North Carolina State (NCSU) to generate new thermal scattering laws, including at lower temperatures, and the lack of integral benchmarks impedes data testing of these new cross sections. To address these needs, this report will present a critical experiment design covering various fission energy regimes with a goal temperature of -40°C (-40°F), which is based on the lower bound of expected non-cryogenic operational temperatures. The goal of the U.S. Nuclear Criticality Safety Program’s (NCSP) Thermal/Epithermal eXperiments (TEX) is to design and conduct new critical experiments to address high priority nuclear data needs from the nuclear criticality safety and nuclear data communities. The TEX program includes two series of baseline experimental configurations, one based on plutonium fuel (plutonium-aluminum Zero Power Physics Reactor (ZPPR) plates) and the other based on uranium fuel (highly enriched uranium (HEU) plates), that are moderated with varying thickness of polyethylene to create assemblies which span the thermal, intermediate, and fast fission energy regimes. The configurations are designed to be easily modified (for example, to add diluent materials of interest) to allow for efficient generation of additional benchmark configurations and allow for added nuclear data testing utility when comparing modified configurations to baseline configurations. The goal of IER-479 is to use the TEX-HEU concept (stack of HEU plates and polyethylene moderators) to design a critical experiment that can be used to validate low temperature cross sections and criticality safety analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Balancing sugar recovery and inhibitor generation during energycane processing: Coupling cryogenic grinding with hydrothermal pretreatment at low temperatures

Pretreatment of lignocellulosic biomass at high temperatures or with oxidizing chemicals generate various inhibitors that restrict the efficient bioconversion of sugars in subsequent steps. The present study systematically investigates individual and combinatorial effects of pretreatment parameters on the generation of inhibitors. Herein, a plot between pretreatment temperature and inhibitor revealed optimum pretreatment temperature for energycane bagasse i.e., 170 °C beyond which total inhibitor production increased exponentially. No inhibitor production was observed on mechanical processing i.e., disk milling/cryogenic grinding of biomass. Evaluation of response surface regression exhibited that biomass solids loading has a significant effect on inhibitor generation at higher temperatures. The concentrations of certain inhibitors such as acetic acid, furfurals, and HMF increased more than 3-folds on doubling the solids loading. Furthermore, a novel low-severity approach of low-temperature hydrothermal pretreatment coupled with cryogenic grinding for lignocellulosic biomasses has been introduced which improved sugar yields while maintaining a low inhibitor concentration.

09 BIOMASS FUELS↗

Reduced-order CFD modeling of cryogenic hydrogen isotope extrusion for pellet fueling

This study presents a reduced-order model (ROM) for computational fluid dynamics (CFD) simulations of cryogenic hydrogen isotope extrusions, focusing on protium (H₂) and deuterium (D₂) piston extruders. Using a 2D axisymmetric ROM in ANSYS-Polyflow, significant computational savings were achieved (runtime reduced from 9∼24 h to 3∼5 min), with extrusion force discrepancies between the 2D ROM and 3D models being on the order of 1%. Parametric studies identified optimal cutoff shear rates in the viscosity model (0.01/s for H₂ and 0.001/s for D₂), providing recommendations for future simulations. Finally, a comprehensive comparison of ROM results with experimental data was performed across varying geometries, cryogenic materials, temperatures, extrusion lengths, and piston velocities. Predictions at low extrusion temperatures met the objective of providing quick and efficient solutions with an acceptable extrusion force error of approximately 10% or less, validating the effectiveness of the 2D ROM approach. However, at high temperatures closer to the triple point, extrusion force error grows, which necessitates developing an improved model that accounts for temperature effects, e.g. melting. Nevertheless, the findings still represent a significant improvement in efficiency of CFD modeling of cryogenic hydrogenic extrusion. The ROM framework can also be extended to tritium (T2) and screw extruders, which will ultimately provide a fast and effective tool for optimizing pellet injector design for ITER and future reactor systems.

Fan, Joy [ORNL] (ORCID:0000000229751735)↗

Cryogenic mechanical behaviors of CrMnFeCoNi high-entropy alloy

The CrMnFeCoNi high-entropy alloy (HEA) exhibits higher yield strength, ultimate strength and ductility at lower temperature. To further clarify the effect of the testing temperature on microstructure evolution, in this study in-situ synchrotron-based high-energy X-ray diffraction tensile tests were carried out from 298 K down to 123 K. The enhanced yield strength of the alloy at cryogenic temperatures can be attributed to the greater lattice distortion prior to plastic deformation. Higher strain hardening rate leads to the simultaneously enhanced strength and ductility of the studied HEA below room temperature. Both dynamic Hall-Petch hardening (twinning) and dislocation hardening provide high work hardening capacity for this alloy during the plastic deformation at cryogenic temperatures. The increased dislocation density and nano-twins at cryogenic temperatures can be attributed to the decrease in the stacking fault energy as the deformation temperature decreases. These studies could provide an in-depth understanding for the strengthening mechanisms of the HEA in different temperature conditions and guide the exploration of HEAs with superb mechanical properties at cryogenic environments.

36 MATERIALS SCIENCE↗

Dispersion of cryogenic hydrogen through high-aspect ratio nozzles

Liquid hydrogen is increasingly being used as a delivery and storage medium for stations that provide compressed gaseous hydrogen for fuel cell electric vehicles. In efforts to provide scientific justification for separation distances for liquid hydrogen infrastructure in fire codes, the dispersion characteristics of cryogenic hydrogen jets (50–64 K) from high aspect ratio nozzles have been measured at 3 and 5 bar abs stagnation pressures. These nozzles are more characteristic of unintended leaks, which would be expected to be cracks, rather than conventional round nozzles. Spontaneous Raman scattering was used to measure the concentration and temperature field along the major and minor axes. Within the field of interrogation, the axis-switching phenomena was not observed, but rather a self-similar Gaussian-profile flow regime similar to room temperature or cryogenic hydrogen releases through round nozzles. The concentration decay rate and half-widths for the planar cryogenic jets were found to be nominally equivalent to that of round nozzle cryogenic hydrogen jets indicating a similar flammable envelope. The results from these experiments will be used to validate models for cryogenic hydrogen dispersion that will be used for simulations of alternative scenarios and quantitative risk assessment.

08 HYDROGEN↗

Powerful Terahertz Emission from a Bi 2 Sr 2 Ca Cu 2 O 8+ δ Mesa Operating Above 77 K

Mesa-shaped structures of the high critical temperature (high-T c ) superconductor Bi 2 Sr 2 CaCu 2 O 8+δ ; contain stacked intrinsic Josephson junctions. As such, they are a promising source of coherent radiation in the "terahertz gap" range, spanning from approximately 0.3 to 2.0 THz. Technological applications of these devices become far more practical if they can be operated at a cryogenic bath temperature of 77 K or higher. Previous works have reported emission from this type of device at high terahertz power levels at lower operating temperatures, 40-60 K, while at T bath >= 77 K observed power levels have generally been low. Here we report generation of 130 mu W of coherent power at 0.456 THz from a mesa of Bi 2 Sr 2 CaCu 2 O 8+δ ; doped with 0.16 holes per Cu atom, at a bath temperature of 77.4 K. Here, we find that the device radiates terahertz power when clearly identifiable cavity modes are excited, and that the frequency and bias voltage corresponding to each of these modes is almost independent of temperature. This is consistent with these modes having terahertz-frequency electric fields with very little dependence on vertical position within the mesa. We also find that the terahertz power radiated from any given mode decreases monotonically as the mesa temperature is increased. On the other hand, the low-frequency modes become inaccessible at low temperatures due to retrapping of the intrinsic Josephson junctions, and the maximum radiation power for the emitting mode is typically achieved at the temperature at which the retrapping voltage reaches the resonance voltage for this mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Beam Induced Heating Analysis Update for the EIC Vacuum Chamber Components

One of the challenges of designing the Electron-Ion Col lider (EIC) is to mitigate beam-induced heating due to the intense electron and hadron beams. Heating of the ESR vac uum chamber components is mainly due to beam-induced resistive wall (RW) losses and synchrotron radiation. For the HSR heating is mainly due to large radial offsets and heat conduction from room temperature to cryogenic tem perature for cryo-components. In this paper, we provide an update on the beam-induced heating and thermal analysis of some critical ESR vacuum chamber components, such as the ESR Large Angle Bremhustraulung Monitor (LABM). We also provide a similar update for critical HSR vacuum com ponents, including the cryo-cooled BPM button assembly, beam screen, abort kicker, and polarimeter. To perform the thermal analyses, the resistive wall loss on individual compo nents is calculated with CST and the synchrotron radiation (if exists) is evaluated using SynRad. These losses, along with realistic boundary conditions are then fed to ANSYS to determine the temperature distribution.

43 PARTICLE ACCELERATORS↗