Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A Framework for Quantifying Measurement Uncertainties and Uncertainty Propagation in HCCI/LTGC Engine Experiments

In this study, a framework for estimating experimental measurement uncertainties for a Homogenous Charge Compression Ignition (HCCI)/Low-Temperature Gasoline Combustion (LTGC) engine testing facility is presented. Detailed uncertainty quantification is first carried out for the measurement of the in-cylinder pressure, whose variations during the cycle provide most of the information for performance evaluation. Standard uncertainties of other measured quantities, such as the engine geometry and speed, the air and fuel flow rate and the intake/exhaust dry molar fractions are also estimated. Propagating those uncertainties using a Monte Carlo simulation and Bayesian inference methods then allows for estimation of uncertainties of the mass-average temperature and composition at IVC and throughout the cycle; and also of the engine performances such as gross Integrated Mean Effective Pressure, Heat Release and Ringing Intensity. Throughout the analysis, nominal values for uncertainty inputs were taken from a well-characterized engine test facility. However, the analysis did not take into account the calibration practice of experiments run in that facility and the resulting uncertainty values are therefore not indicative of the expected accuracy of those experimental results. A future study will employ the methodology developed here to explore the effects of different calibration methods on the different uncertainty values in order to evaluate best practices for accurate engine measurements.

02 PETROLEUM↗

Blackbody comparator for thermocouple calibration

MIKES is developing a measurement set-up for calibrating thermocouples in the temperature range 960 °C - 1500 °C. The calibration method is based on direct comparison of thermocouples and radiation thermometers. We have designed a graphite blackbody comparator cell, which is operated in a horizontal single-zone tube furnace. The cell includes two blackbody cavities for radiation temperature measurements. The cavities have openings on opposite sides of the cell, allowing simultaneous measurement with two radiation thermometers. The design of the comparator allows three thermocouples to be calibrated simultaneously. The thermocouples to be calibrated are inserted in thermometer wells around one of the measurement cavities. We characterize the blackbody comparator in terms of repeatability, temperature distribution and emissivity. Finally, we validate the uncertainty analysis by comparing calibration results obtained for type B and S thermocouples to the calibration results reported by Technical Research Institute of Sweden (SP), and MIKES. The agreement in the temperature range 1000 °C - 1500 °C is within 0.90 °C, the average deviation being 0.17 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-07: Response Characteristics and Signal Conversion Modeling of KV Flat-Panel Detector in Cone Beam CT System

Purpose: The flat-panel detector response characteristics are investigated to optimize the scanning parameter considering the image quality and less radiation dose. The signal conversion model is also established to predict the tumor shape and physical thickness changes. Methods: With the ELEKTA XVI system, the planar images of 10cm water phantom were obtained under different image acquisition conditions, including tube voltage, electric current, exposure time and frames. The averaged responses of square area in center were analyzed using Origin8.0. The response characteristics for each scanning parameter were depicted by different fitting types. The transmission measured for 10cm water was compared to Monte Carlo simulation. Using the quadratic calibration method, a series of variable-thickness water phantoms images were acquired to derive the signal conversion model. A 20cm wedge water phantom with 2cm step thickness was used to verify the model. At last, the stability and reproducibility of the model were explored during a four week period. Results: The gray values of image center all decreased with the increase of different image acquisition parameter presets. The fitting types adopted were linear fitting, quadratic polynomial fitting, Gauss fitting and logarithmic fitting with the fitting R-Square 0.992, 0.995, 0.997 and 0.996 respectively. For 10cm water phantom, the transmission measured showed better uniformity than Monte Carlo simulation. The wedge phantom experiment show that the radiological thickness changes prediction error was in the range of (-4mm, 5mm). The signal conversion model remained consistent over a period of four weeks. Conclusion: The flat-panel response decrease with the increase of different scanning parameters. The preferred scanning parameter combination was 100kV, 10mA, 10ms, 15frames. It is suggested that the signal conversion model could effectively be used for tumor shape change and radiological thickness prediction. Supported by National Natural Science Foundation of China (81101132, 11305203) and Natural Science Foundation of Anhui Province (11040606Q55, 1308085QH138)

60 APPLIED LIFE SCIENCES↗

THE ATACAMA COSMOLOGY TELESCOPE: CALIBRATION WITH THE WILKINSON MICROWAVE ANISOTROPY PROBE USING CROSS-CORRELATIONS

We present a new calibration method based on cross-correlations with the Wilkinson Microwave Anisotropy Probe (WMAP) and apply it to data from the Atacama Cosmology Telescope (ACT). ACT's observing strategy and map-making procedure allows an unbiased reconstruction of the modes in the maps over a wide range of multipoles. By directly matching the ACT maps to WMAP observations in the multipole range of 400 < l < 1000, we determine the absolute calibration with an uncertainty of 2% in temperature. The precise measurement of the calibration error directly impacts the uncertainties in the cosmological parameters estimated from the ACT power spectra. We also present a combined map based on ACT and WMAP data that has a high signal-to-noise ratio over a wide range of multipoles.

79 ASTRONOMY AND ASTROPHYSICS↗

CALiPER Exploratory Study: Accounting for Uncertainty in Lumen Measurements

With a well-defined and shared understanding of uncertainty in lumen measurements, testing laboratories can better evaluate their processes, contributing to greater consistency and credibility of lighting testing a key component of the U.S. Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) program. Reliable lighting testing is a crucial underlying factor contributing toward the success of many energy-efficient lighting efforts, such as the DOE GATEWAY demonstrations, Lighting Facts Label, ENERGY STAR® energy efficient lighting programs, and many others. Uncertainty in measurements is inherent to all testing methodologies, including photometric and other lighting-related testing. Uncertainty exists for all equipment, processes, and systems of measurement in individual as well as combined ways. A major issue with testing and the resulting accuracy of the tests is the uncertainty of the complete process. Individual equipment uncertainties are typically identified, but their relative value in practice and their combined value with other equipment and processes in the same test are elusive concepts, particularly for complex types of testing such as photometry. The total combined uncertainty of a measurement result is important for repeatable and comparative measurements for light emitting diode (LED) products in comparison with other technologies as well as competing products. This study provides a detailed and step-by-step method for determining uncertainty in lumen measurements, working closely with related standards efforts and key industry experts. This report uses the structure proposed in the Guide to Uncertainty Measurements (GUM) for evaluating and expressing uncertainty in measurements. The steps of the procedure are described and a spreadsheet format adapted for integrating sphere and goniophotometric uncertainty measurements is provided for entering parameters, ordering the information, calculating intermediate values and, finally, obtaining expanded uncertainties. Using this basis and examining each step of the photometric measurement and calibration methods, mathematical uncertainty models are developed. Determination of estimated values of input variables is discussed. Guidance is provided for the evaluation of the standard uncertainties of each input estimate, covariances associated with input estimates and the calculation of the result measurements. With this basis, the combined uncertainty of the measurement results and finally, the expanded uncertainty can be determined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetic Methods for Tracking Particle Motions and Temperatures within Opaque Vessels

A three year LDRD was undertaken to look at the feasibility of using magnetic sensing to determine flows within sealed vessels at high temperatures and pressures. Uniqueness proofs were developed for tracking of single magnetic particles with multiple sensors. Experiments were shown to be able to track up to 3 dipole particles undergoing rigid-body rotational motion. Temperature was wirelessly monitored using magnetic particles in static and predictable motions. Finally high-speed vibrational motion was tracked using magnetic particles. Ideas for future work include using small particles for measuring vorticity and better calibration methods for tracking multiple particles.

47 OTHER INSTRUMENTATION↗

Statistical modeling support for calibration of a multiphysics model of subcooled boiling flows

Nuclear reactor system analyses rely on multiple complex models which describe the physics of reactor neutronics, thermal hydraulics, structural mechanics, coolant physico-chemistry, etc. Such coupled multiphysics models require extensive calibration and validation before they can be used in practical system safety study and/or design/technology optimization. This paper presents an application of statistical modeling and Bayesian inference in calibrating an example multiphysics model of subcooled boiling flows which is widely used in reactor thermal hydraulic analysis. The presence of complex coupling of physics in such a model together with the large number of model inputs, parameters and multidimensional outputs poses significant challenge to the model calibration method. However, the method proposed in this work is shown to be able to overcome these difficulties while allowing data (observation) uncertainty and model inadequacy to be taken into consideration. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thomson spectrometer-microchannel plate assembly calibration for MeV-range positive and negative ions, and neutral atoms

We report on the absolute calibration of a microchannel plate (MCP) detector, used in conjunction with a Thomson parabola spectrometer. The calibration delivers the relation between a registered count numbers in the CCD camera (on which the MCP phosphor screen is imaged) and the number of ions incident on MCP. The particle response of the MCP is evaluated for positive, negative, and neutral particles at energies below 1 MeV. As the response of MCP depends on the energy and the species of the ions, the calibration is fundamental for the correct interpretation of the experimental results. The calibration method and arrangement exploits the unique emission symmetry of a specific source of fast ions and atoms driven by a high power laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ADVANCED WAVEFORM SIMULATION FOR SEISMIC MONITORING EVENTS

The recent Nevada Earthquake (M=6) produced an extraordinary set of crustal guided waves. In this study, we examine the three-component data at all the USArray stations in terms of how well existing models perform in predicting the various phases, Rayleigh waves, Love waves, and Pnl waves. To establish the source parameters, we applied the Cut and Paste Code up to distance of 5° for an average local crustal model which produced a normal mechanism (strike=35°,dip=41°,rake=-85°) at a depth of 9 km and Mw=5.9. Assuming this mechanism, we generated synthetics at all distances for a number of 1D and 3D models. The Pnl observations fit the synthetics for the simple models well both in timing (VPn=7.9km/s) and waveform fits out to a distance of about 5°. Beyond this distance a great deal of complexity can be seen to the northwest apparently caused by shallow subducted slab material. These paths require considerable crustal thinning and higher P-velocities. Small delays and advances outline the various tectonic province to the south, Colorado Plateau, etc. with velocities compatible with that reported on by Song et al.(1996). Five-second Rayleigh waves (Airy Phase) can be observed throughout the whole array and show a great deal of variation ( up to 30s). In general, the Love waves are better behaved than the Rayleigh waves. We are presently adding higher frequency to the source description by including source complexity. Preliminary inversions suggest rupture to northeast with a shallow asperity. We are, also, inverting the aftershocks to extend the frequencies to 2 Hz and beyond following the calibration method outlined in Tan and Helmberger (2007). This will allow accurate directivity measurements for events with magnitude larger than 3.5. Thus, we will address the energy decay with distance as s function of frequency band for the various source types.

58 GEOSCIENCES↗

Commissioning of the discrete spot scanning proton beam delivery system at University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston

Purpose: To describe a summary of the clinical commissioning of the discrete spot scanning proton beam at the Proton Therapy Center, Houston (PTC-H). Methods: Discrete spot scanning system is composed of a delivery system (Hitachi ProBeat), an electronic medical record (Mosaiq V 1.5), and a treatment planning system (TPS) (Eclipse V 8.1). Discrete proton pencil beams (spots) are used to deposit dose spot by spot and layer by layer for the proton distal ranges spanning from 4.0 to 30.6 g/cm{sup 2} and over a maximum scan area at the isocenter of 30x30 cm{sup 2}. An arbitrarily chosen reference calibration condition has been selected to define the monitor units (MUs). Using radiochromic film and ion chambers, the authors have measured spot positions, the spot sizes in air, depth dose curves, and profiles for proton beams with various energies in water, and studied the linearity of the dose monitors. In addition to dosimetric measurements and TPS modeling, significant efforts were spent in testing information flow and recovery of the delivery system from treatment interruptions. Results: The main dose monitors have been adjusted such that a specific amount of charge is collected in the monitor chamber corresponding to a single MU, following the IAEA TRS 398 protocol under a specific reference condition. The dose monitor calibration method is based on the absolute dose per MU, which is equivalent to the absolute dose per particle, the approach used by other scanning beam institutions. The full width at half maximum for the spot size in air varies from approximately 1.2 cm for 221.8 MeV to 3.4 cm for 72.5 MeV. The measured versus requested 90% depth dose in water agrees to within 1 mm over ranges of 4.0-30.6 cm. The beam delivery interlocks perform as expected, guarantying the safe and accurate delivery of the planned dose. Conclusions: The dosimetric parameters of the discrete spot scanning proton beam have been measured as part of the clinical commissioning program, and the machine is found to function in a safe manner, making it suitable for patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Humidity effects on calibrations of radiation therapy electrometers

Purpose: To eliminate variation in electrometer calibration results caused by high humidity and suboptimal connectors on the standard capacitors and to implement hardware that prevents overloading of the input stage of electrometers during calibration. Methods: A humidity-controlled cabinet was installed to provide a low-humidity environment for the standard capacitors. All of the coaxial BNC connections were replaced with Triax (TRB) connectors with the exception of the output from the voltage source. A three-stage RC filter with cascaded RC low-pass sections was designed and tested. Results: The installation of the humidity cabinet resulted in a major improvement in the stability and reproducibility of the electrometer calibration system. For the three years since this upgrade, the Ionizing Radiation Standards (IRS) electrometer calibration results have been consistent regardless of the ambient relative humidity in the lab. The connector replacements improved grounding in the calibration circuit. The three-stage filter allows the voltage at the output to rise in an S-shaped waveform, resulting in a smooth rise of the current through the isolation resistor from zero and back again, with no abrupt transition. For the filter design chosen, 99.99% of the charge is delivered within 6 s. Conclusions: A three-way improvement to the calibration measurement system was successful in eliminating the observed variations, resulting in an electrometer calibration measurement system that is unaffected by humidity and allowing reliable year-round calibrations of any electrometer encountered since the implementation of these changes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian calibration of the Community Land Model using surrogates

We present results from the Bayesian calibration of hydrological parameters of the Community Land Model (CLM), which is often used in climate simulations and Earth system models. A statistical inverse problem is formulated for three hydrological parameters, conditional on observations of latent heat surface fluxes over 48 months. Our calibration method uses polynomial and Gaussian process surrogates of the CLM, and solves the parameter estimation problem using a Markov chain Monte Carlo sampler. Posterior probability densities for the parameters are developed for two sites with different soil and vegetation covers. Our method also allows us to examine the structural error in CLM under two error models. We find that surrogate models can be created for CLM in most cases. The posterior distributions are more predictive than the default parameter values in CLM. Climatologically averaging the observations does not modify the parameters' distributions significantly. The structural error model reveals a correlation time-scale which can be used to identify the physical process that could be contributing to it. While the calibrated CLM has a higher predictive skill, the calibration is under-dispersive.

54 ENVIRONMENTAL SCIENCES↗

Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement

The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration.

42 ENGINEERING↗

Out-of-pile performance of High Temperature Irradiation Resistant and Cladding Thermocouples

The High Temperature Irradiation Resistant thermocouple (HTIR-TCs) has proven to be the nuclear temperature sensor. It outlast and outperforms all other commercially available thermocouples above 1100 °C inside reactor pressure vessels; also, recent calibration methods have pushed the HTIR-TC to accurately read temperatures through thermal transients during reactor shutdowns and restarts. The new temperature range of HTIR-TCs is from 0 °C to 1650 °C. The main objective of this study is to address manufacturing a more robust TC for handling and inserting into reactor experiments; to also apply the TC to a wider application. The TC has shown to be mainly susceptible to oxygen levels inside the heat treatment and calibration process and it is recommended that O2 levels be brought to as low as possible. However, through modeling efforts the O2 has been found to intercalate only within the first few layers of niobium on the outer sheath. Lastly, multiple materials were used for the sheath and insulators; all with similar outcomes when testing occurred over a long period of time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian Calibration of the Community Land Model using Surrogates

We present results from the Bayesian calibration of hydrological parameters of the Community Land Model (CLM), which is often used in climate simulations and Earth system models. A statistical inverse problem is formulated for three hydrological parameters, conditioned on observations of latent heat surface fluxes over 48 months. Our calibration method uses polynomial and Gaussian process surrogates of the CLM, and solves the parameter estimation problem using a Markov chain Monte Carlo sampler. Posterior probability densities for the parameters are developed for two sites with different soil and vegetation covers. Our method also allows us to examine the structural error in CLM under two error models. We find that accurate surrogate models can be created for CLM in most cases. The posterior distributions lead to better prediction than the default parameter values in CLM. Climatologically averaging the observations does not modify the parameters’ distributions significantly. The structural error model reveals a correlation time-scale which can potentially be used to identify physical processes that could be contributing to it. While the calibrated CLM has a higher predictive skill, the calibration is under-dispersive.

Bayesian calibration↗

Exploring Uncertainty in Moment Estimation for Small Earthquakes in Southern Nevada Using the Coda Envelope Method

Compiling source parameter estimates for small earthquakes is important both for our understanding of earthquake physics and for accurately assessing earthquake hazard. Reliable source parameter estimates are difficult to achieve for small earthquakes, in part due to our inability to accurately model the relevant physical processes at high frequencies. The coda envelope methodology developed by Mayeda and Walter (1996) and Mayeda et al. (2003) can mitigate this concern and estimate the moment of small earthquakes by determining the parameters that control the shape of the S-wave coda envelope while eliminating path effects by minimizing the scatter between seismic stations. Here, we use an open-source implementation of this technique called the Coda Calibration Tool (CCT; Barno, 2017) to calculate CCT-based moment magnitude estimates of small earthquakes (M L 0–3) in the Rock Valley, Nevada, region within the Nevada National Security Site. The Rock Valley data set is of particular interest because it allows us to explore the changes in uncertainties of the coda calibration method with earthquake size and depth. We found that a consistent linear relationship exists between the local magnitude M L and our coda-derived M w estimates for earthquakes as small as M L 0–3, but that current CCT workflows do not accurately characterize very shallow events. We also demonstrate that the epistemic uncertainty in the apparent stress value assumed by the CCT algorithm can influence magnitude estimates of small earthquakes. In conclusion, these results provide valuable insight into the seismicity of this region, and inform future analysis and modeling efforts for nuclear monitoring and seismic hazard.

58 GEOSCIENCES↗

Application of Generalized Standard Addition Method and Ultraviolet Spectroscopy to Quantify Electrolytic Depolymerization of Lignin

Industrial lignin waste is an important byproduct of bio-refineries and the paper industry. Depolymerization of this industrial lignin could generate useful aromatic compounds. This group has focused on electrolytic decomposition of biorefinery lignin. To quantify electrolytic decomposition of the lignin in a highly caustic solution, ultraviolet (UV) spectroscopy provides a useful probe. The conversion of the neat lignin to the oxidized products achieved by the electrolytic reactor may be measured by quantifying the amount of unreacted neat lignin that remains in the effluent. Because the properties of electrolytic decomposition products are largely unknown, a useful approach to quantify decomposition of the neat lignin is to use a multivariate calibration method referred to as the generalized standard addition method (GSAM). In this approach, the electrolytic decomposition products represent a background interference and the neat lignin that remains can be quantified. Furthermore, this approach allows the conversion of the neat lignin to be calculated in a solution that is a complex mixture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗