Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Differential Impact of Climate Change on the Hydropower Economies of Karakoram and Himalayan River Basins

Water stored in the form of snow and glaciers in the High Mountain Asia (HMA) region regulates the water supply, and resultant water-based economies, that support the livelihoods of millions of people. Trends in the seasonal and long-term melting of snow and glaciers, governed by initial ice reserves, meteorological factors and geographic features, vary across sub-basins in the HMA region. We examined the economic impacts of climate-led changes in river flow in two drainage basins, one each from the Karakoram and Central Himalaya region. We used an integrated assessment framework to estimate the changes in economic value of the hydropower generation from hydropower plants on rivers fed by snow and glacier melt in the two sub-basins. The framework, developed under a NASA High Mountain Asia project, coupled biophysical models (a suite of climate models, snow/glacier-hydrology, and hydropower model) with economic analysis. We compared the differences in estimated river flow over historic and future time using the water balance model in sixteen scenarios (eight climate models and two emissions scenarios) for rivers upstream of hydropower plants in each sub-basin. Using the hydropower model we developed, we estimated the changes in hydropower generation at the Naltar IV hydropower plant, with an 18 MW capacity, located in Hunza, Karakoram, and the Trishuli hydropower plant, with a 19.6 MW capacity, in Trishuli, Central Himalaya. When compared to their baselines, the estimated impact of climate change and temporal variability were higher for the Naltar plant than for the Trishuli plant. Our sensitivity analysis shows that hydropower plants with water storage facilities help reduce the impact of changes, but the estimated impacts are higher for the higher capacity plants. This study provides an example of the differential impacts of climate change on hydropower plants located in rivers fed by varying amounts of snow and glacier melt at different decades in this century. This type of integrated assessment of climate change impact will support the scientific understanding of hydrologic flow and its impacts on a hydropower economy under various climate scenarios, as well as generate information about water resource management in a changing climate.

climate change↗

Sedimentation and Nonlinear Trapping in Texas Reservoirs Identified Using Remote Sensing and Bathymetric Survey Records

Decreasing reservoir storage capacity due to sedimentation poses great challenges to aging U.S. reservoirs, as it reduces the efficacy and reliability of their socio‐economic services. However, systematic assessments of reservoir sedimentation rates and associated issues remain limited because of sparse and infrequent bathymetry survey data. In this study, we use remote sensing‐driven estimates of sediment concentrations to identify regions experiencing rapid reservoir capacity loss, as observed in repeated bathymetry surveys. Our analysis focuses on Texas, where one of the most reliable state‐level reservoir capacity loss data sets is available through a unique long‐term monitoring program by the Texas Water Development Board. We find that reservoirs with large storage capacities and high sedimentation rate are concentrated in Northeast Texas. We also show that reduced forest, increased barren land, and erosive soil properties are co‐varying with high reservoir sedimentation rates. Temporal changes in the longitudinal gradient of the remotely sensed sediment flux highlight the nonlinear nature of sediment trapping processes, and can be used to estimate the reservoir storage capacity loss over time. In combination with standard bathymetry surveys, our approach shows potential for more cost‐effective and frequent assessment of reservoir storage loss.

Lee, Jiyong [ORNL] (ORCID:0000000198957406)↗

IDAES Enterprise: Generation Expansion Planning with Enhanced Requirements for Capacity Adequacy Under Renewable Intermittency

Achieving net zero carbon emissions likely requires future power systems to integrate new, flexible energy technologies to accommodate higher levels of capacity from variable renewable energy sources. To determine the optimal deployment of new electricity capacity and to study the likelihood of deployments of new energy technologies, an expansion planning model has been developed as part of the IDAES-Enterprise suite of grid models. The Generation Expansion Planning (GEP) model is a multi-period model in which investment decisions occur yearly, and a Unit Commitment (UC) problem is examined on an hourly timescale. To reduce computational complexity of the GEP model, the UC problem is solved for average “representative days” which leaves out extreme, but relatively common, scenarios in which low renewable generation occurs, leaving the system with inadequacy in capacity. The IDAES-Enterprise GEP model has been modified to include these extreme scenarios while keeping the model reasonably tractable. Specifically, a lazy constraint technique was implemented to check for capacity adequacy on an hourly basis over a large data set of aligned load-wind-solar profiles. As a vast majority of the capacity constraints will not be violated, the technique lowers computational expense by searching for violated capacity constraints over an “iterative manner,” adding those infeasible constraints back into the model. Results on a test case of the Southwest Power Pool shows that the lazy constraint technique significantly reduces retirements and increases installments of natural gas combined cycles and flexible natural gas units. It also reduces some retirements of coal units. These modifications provide a more reasonable estimation of required dispatchable power generation capacity to ensure feasibility during peak net load.

Liu, Peng↗

Evaluation of Load Behavior for Select Analytes in Hanford Tank Waste

Crystalline silicotitanate (CST) inorganic ion exchanger is a candidate material for remediation of highly alkaline (pH > 14) aqueous nuclear waste streams containing high sodium concentrations (>5 M). In this work, ion exchange column testing with wastes from Hanford tanks AP-105, AP-107, and AW-102 was carried out to study the uptake of 137 Cs to estimate the decontamination factor (DF) value. Additionally, DF values for uptake of Al, Ca, Pb, Np, Pu, U, and Sr were determined and the ion exchange capacity of CST toward these analytes was estimated. Limited data is available on the load behavior of other minor and trace elements with recent CST production lots and this characterization will help improve understanding of the behavior of CST and assist in identifying potential disposition pathways as well as assessing removal capabilities of CST for other components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hourly Electricity Demand Profiles for Each County in the Contiguous United States

This dataset provides estimated hourly electricity demand for each county in the contiguous United States from 2016-2023. The demand profiles represent the sum of two components: (1) Weighted averages of reported hourly demand profiles for North American Electric Reliability Corporation balancing authority (BA) regions and subregions, scaled to match annual estimates of county-level retail sales and direct use of electricity and weighted by the estimated percentage of county load served by each BA region or subregion. (2) Weighted averages of modeled hourly, county- and sector-level distributed photovoltaic (DPV) capacity factor profiles, scaled to match annual estimates of on-site consumption of DPV-generated electricity for each county and weighted by the percentage of consumption attributable to each sector Annual county-level retail sales are estimated by aggregating utility-reported sales to the state level and allocating the results to counties according to each county's share of state population. Annual county-level direct use is calculated by aggregating power plant-reported direct use values. Annual county-level on-site consumption of DPV-generated electricity is estimated by aggregating utility-reported net metering data to determine the amount of DPV-generated electricity sold back to the grid for each state, subtracting those values from modeled state-level DPV generation estimates, and allocating the results to counties according to each county's share of statewide modeled DPV generation. The open-source Python code used to develop this dataset is available at "Historical Load Data Repository" link below.

14 SOLAR ENERGY↗

Future Wind Energy Resources and Cost Uncertainties Across the United States

This dataset contains results estimating projections of change of annual capacity factors and levelized cost of energy for several turbine technologies in the 2024 Annual Technology Baseline (ATB). Projections of change are based on downscaled earth system model (ESM) data from Sup3rCC. There has been evidence of reductions in average wind speeds over land in North America since the 1980s, and several models project that average wind speeds will continue to decrease. Concurrently, the cost of wind energy systems in the United States has been decreasing since around 2010, a trend also projected to continue. There is considerable uncertainty in these future projections, with quantitative estimates of future wind resource and system costs varying widely. To study this, we run land-based wind energy models with a range of possible future system costs, turbine designs, and meteorological inputs from multiple downscaled earth system models over the contiguous United States to estimate critical system performance metrics such as annual energy production (AEP) and levelized cost of energy. Where multiple earth system models agree, changes in mean AEP from the time period 2000-2019 to 2040-2059 can be as high as +10% in South Texas or as low as -20% in Iowa. Several additional states in the Midwest that currently have considerable wind generation capacity show the possibility of substantial decreases in AEP by mid-century. Larger turbines and moderate reductions in system costs can offset even the largest projected decreases in wind resource, but much uncertainty remains in the extent to which wind resources will actually change into the future and to what extent wind energy systems can drive down future costs. An analysis of variance shows, in several states in the Midwest, the uncertainty in future wind resource can be almost as important for future changes in the cost of wind energy as the uncertainty in future system costs.

17 WIND ENERGY↗

Advanced Processing of Coal and Coal Waste to Produce Graphite for Fast-Charging Lithium-Ion Battery Anode

The University of North Dakota (UND) Energy & Environmental Research Center (EERC), in collaboration with the UND Center for Process Engineering Research (CPER), conducted a project to validate two technologies capable of converting North Dakota lignite and lignite coal waste to high-quality graphite for fast-charging lithium-ion battery (LIB) anode. The project was conducted over about 3 years from April 7, 2022, to July 6, 2025. The two technological paths pursued in this project include path A – direct conversion of coal or coal waste to graphite by the upgraded carbon ores to products (UCOP) process being developed at the EERC and path B – lignite-derived coal tar pitch (CTP) conversion to graphite (CTP2G) process being developed at CPER. The results from this project validate the two technological approaches and are expected to be an integral part of a portfolio of emerging technologies for making high-quality graphite not only from North Dakota lignite, but from all ranks of U.S. domestic coal and coal waste resources. The quality of the graphite produced by these technologies is high enough for various applications, including batteries for the fast-growing electric vehicle industry, energy storage applications, electric arc furnace electrodes for steel production, and graphene production, among others. Although the two technologies can produce high-quality graphite, they are fundamentally different in that the UCOP technology provides a direct path to transform coal to graphite, while the CTP2G technology needs to go through a CTP intermediate and a coking process for the intermediate, which requires a special facility to accomplish. For application in the industry, the UCOP process is designed to be more flexible, with feedstock to include potentially any carbonaceous material such as all coal ranks and biochar, while the CTP2G process is designed to utilize CTP as the starting precursor. The key project accomplishments include the following: • Successful preparation of high-quality synthetic graphite from North Dakota lignite coal/coal wastes and lignite-derived CTP. • Patent application has been filed for the UCOP process and an internal invention disclosure has been filed for the CTP2G process. • The produced graphite performs better than a commercial battery-grade sample in LIB coin cells, especially fast-charging capability, stability, and long-duration cycling. • Coin-type Li-ion half-cells with CTP2G graphite showed excellent performance, with >370 mAh/g capacity, >90% initial coulombic efficiency, and 93%/67% retention at 1C/2C rate, which outperforms commercial graphite in charging speed, stability, and cycling. • Results of fabricated 18650 cells were consistent with the observations in coin cells. • Preliminary techno-economic analysis (TEA) estimates for the UCOP technology indicate a manufacturing cost of about $\$$39/kg based on 50-metric ton/year capacity. • Preliminary TEA estimates for the CTP2G technology indicate a market price of about $\$$7107/ton ($\$$7/kg) based on 22,000-ton/year production capacity.

01 COAL, LIGNITE, AND PEAT↗

Drain Tank Information for Developing Design Basis of the Preliminary Design - R00

Tokamak Cooling Water System (TCWS) drain tanks (DTs) serve two functions: normal operation and safety operation. Normal DTs are used for regular maintenance operations when draining is necessary. Safety DTs are used to receive the water leaked into the Vacuum Vessel (VV) after an in-vessel loss of cooling accident (LOCA) event. The preliminary design of the DTs shall be based on the information provided by this document. The capacity of the normal DTs is estimated based on the internal volume of in-vessel components [e.g., First Wall/Blanket (FW/BLK) and Divertor (DIV)], Neutral Beam Injector (NBI) components, and TCWS piping, heat exchangers, electric heaters, pump casing, pressurizers, and valves. Water volumes have been updated based on 2004 design information, changes adopted because of approved Project Change Requests (PCRs), and data verification by U.S. ITER. Two tanks will store water from normal draining operations of the FW/BLK and DIV Primary Heat Transfer Systems (PHTSs). One tank will store water from normal draining operations of the NBI PHTS. The capacity of the safety DTs is based on analysis of a design-basis accident:1 a large leak from in-vessel components. There are two safety DTs that will receive water from a VV LOCA event and drainage from the VV, as needed. In addition, there is one sump tank for the DIV that will be used for collecting drain water from the draining and drying processes and specifically for draining the DIV system as the DIV cassettes lines are at a lower elevation than the DT connection point. Information documented in this report must be refined and verified during the preliminary design of the DTs, and there are several aspects to be considered to complete the preliminary design. Input to these design considerations is discussed in this report and includes, but is not limited to, water inventory; operating procedures/maintenance; Failure Modes and Effects Analysis (FMEA); tank layout anddimensions, including design margin; classification under French Nuclear Pressure Directives, Equipements Sous Pression Nucleaires (ESPN); and adaptations for construction.

Cooling Water↗

Estimated Hourly Electricity Demand Profiles for Each County in the Contiguous United States

In this data descriptor, we present hourly electricity demand estimates for each county in the contiguous United States from 2016 to 2023. The demand profiles represent the sum of two components for each county. The first is the weighted average of reported hourly demand profiles for North American Electric Reliability Corporation balancing authority (BA) regions and subregions, scaled to match annual estimates of county-level retail sales and direct use of electricity and weighted by the estimated percentage of county load served by each BA region or subregion. The second is the weighted average of modeled hourly, county- and sector-level distributed photovoltaic (DPV) capacity factor profiles, scaled to match annual estimates of on-site consumption of DPV-generated electricity for each county and weighted by the percentage of consumption attributable to each sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Perennialization and Cover Cropping Mitigate Soil Carbon Loss from Residue Harvesting

While the US Midwest is expected to serve as a primary feedstock source for cellulosic biofuel production, the impacts of residue harvesting on soil organic carbon (SOC) may greatly limit sustainable production capacity. However, viable feedstock production could be realized through adoption of management practices and cropping systems that offset residue‐harvest‐induced SOC losses. Sequestration of SOC can be enhanced by increasing the duration of crop soil cover through cover or double cropping or cultivation of dedicated perennials. However, assessing the efficacy of such options across sites and over long periods is experimentally challenging. Hence, we use the Environmental Productivity Integrated Climate (EPIC) model to provide such an assessment. Model‐data integration was used to calibrate and evaluate model suitability, which exhibited reasonable effectiveness through R 2 of 0.97 and 0.63 for SOC stock and yield, respectively. Long‐term simulations indicate considerable capacity for offsetting SOC loss. Incorporating rye ( Secale cereal L.) into continuous corn ( Zea mays L.) and corn–soybean [ Glycine max (L.) Merr.] systems offset the SOC losses induced by harvesting 21.2 and 38.3% of available stover, respectively. Similarly, converting 20.4% of corn–soybean land to miscanthus ( Miscanthus × giganteus J.M. Greef & Deuter ex Hodkinson & Renvoize) or 27.5% of land to switchgrass ( Panicum virgatum L.) offset the SOC impacts of harvesting 60% of stover from the remaining corn–soybean lands. These responses indicate that adoption of such measures would sizably affect the life cycle consequences of residue‐derived biofuels and expand estimates of sustainable cellulosic feedstock production capacity from the US Midwest. Core Ideas EPIC suitably assessed SOC under annual, cover, double, and perennial crops. Perennial cultivation offset the SOC losses of considerable residue harvesting. Rye double crops offset sizable residue‐induced SOC losses. Adoption could greatly expand Midwestern sustainable biofuel production capacity.

Jones, Curtis D.↗

Drain Tank Information for Developing Design Basis of the Preliminary Design

Tokamak Cooling Water System (TCWS) drain tanks (DTs) serve two functions: normal operation and safety operation. Normal DTs are used for regular maintenance operations when draining is necessary. Safety DTs are used to receive the water leaked into the Vacuum Vessel (VV) after an in-vessel loss of coolant accident (LOCA) event. The preliminary design of the DTs shall be based on the information provided by this document. The capacity of the normal DTs is estimated based on the internal volume of in-vessel components [e.g., First Wall/Blanket (FW/BLK) and Divertor (DIV)]; Neutral Beam Injector (NBI) components; and TCWS piping, heat exchangers, electric heaters, pump casing, pressurizers, and valves. Water volumes have been updated based on 2004-design information, changes adopted because of approved Project Change Requests (PCRs), and data verification by US ITER and AREVA Federal Services, the US ITER A and E Company. Two tanks will store water from normal draining operations of the FW/BLK and DIV Primary Heat Transfer Systems (PHTSs). One tank will store water from normal draining operations of the NBI PHTS. The capacity of the safety DTs is based on analysis of a design basis accident: a large leak from in-vessel components. There are two safety DTs that will receive water from a VV LOCA event and drainage from the VV, as needed. In addition, there is one sump tank for the DIV that will be used for collecting drain water from the draining and drying processes and specifically for draining the DIV system as the DIV cassette lines are at a lower elevation than the DT connection point. Information documented in this report must be refined and verified during the preliminary design of the DTs, and there are several aspects to be considered to complete the preliminary design. Input to these design considerations is discussed in this report and includes, but is not limited to, water inventory; operating procedures/maintenance; Failure Modes and Effects Analysis (FMEA); tank layout and dimensions, including design margin; classification under French Nuclear Pressure Directives, Equipements Sous Pression Nucleaires (ESPN); and adaptations for construction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Machine-learning-based estimates of global natural vegetated wetland methane emissions (2000–2025)

Wetlands are the largest natural source of atmospheric methane (CH 4 ), yet comprehensive global budgets are typically delayed by years, preventing a timely understanding of CH 4 sources, sinks, and trends. To reduce this delay, we present a model emulator-driven framework and accompanying workflow that enable timely, continuous emission updates using a machine-learning emulator to reconstruct spatially explicit monthly emission fields at 1° × 1° resolution. We apply this framework to a global dataset of natural vegetated wetland CH 4 emissions to extend the most recent Global Methane Budget (GMB; Saunois et al., 2025) record that covers the 2000–2020 emissions through 2025. In the test data (∼ 30 % of the total dataset), the emulator achieved a global R 2 of 0.65 ± 0.003 (mean ± 95 % CI, hereafter) and an RMSE of 5.49 ± 0.12×10 -3 Tg CH 4 yr −1 . The emulator is trained on 35 GMB model estimates, including 22 process-based models and 13 atmospheric inversions, paired with 10 ensemble realizations of 11 gridded climate predictor variables from atmospheric reanalyses. Our results show that the global mean predicted wetland CH 4 emissions for 2021–2025 (157.8 ± 2.4 Tg CH 4 yr −1 ) are not significantly higher (∼ 0.05 Tg CH 4 yr −1 ) than the 2000–2020 baseline. However, this stability masks a significant hemispheric redistribution of emissions. We detect an increase in Northern Hemisphere (NH) emissions in 2021–2025, with mid- and high-latitudes increasing by 0.76 ± 0.07 and 0.35 ± 0.03 Tg CH 4 yr −1 , respectively, while the tropics and Southern Hemisphere (SH) extratropics show offsetting negative trends (−0.95 ± 0.19 and -0.11 ± 0.02 Tg CH 4 yr −1 , respectively). The predicted emissions are able to capture the low emissions in 2023 in South America linked to El Niño-related drought, as reported by recent studies (Ciais et al., 2026; Quinn et al., 2025). Furthermore, we identify a distinct seasonal amplification of global emission trends that peaks in late boreal summer. This new modeled dataset and operational framework bridge the gap between the latest updated budgets and low-latency monitoring, providing a scalable capacity to frequently update global emission estimates and critical early warnings of regional wetland feedback loops. The data are publicly available at https://doi.org/10.5281/zenodo.18870108 (Li et al., 2026).

Li, Mengze [National University of Singapore (Sing↗

Driving the grid forward: How electric vehicle adoption shapes power system infrastructure and emissions

We model the effect of plug-in electric vehicle (EV) adoption on U.S. power system generator capacity investment, operations, and emissions through 2050 by estimating power systems outcomes under a range of EV adoption trajectory scenarios. Our EV adoption scenarios are informed by 1) an Energy Information Administration scenario with no policy intervention, 2) EV growth expected under the Inflation Reduction Act (IRA), 3) a Biden Administration 50% EV sales target by 2030, 4) the Environmental Protection Agency’s projections under vehicle emissions standards, and 5) the International Energy Agency’s roadmap to Net Zero by 2050. We find across these scenarios that increasing EV adoption induces investment in new wind, solar, storage, and natural gas capacity, affecting power generation mix and emissions. The net effect of increasing EV adoption beyond our IRA base case is to increase power sector emissions by about 5 mtCO 2 eq per EV-year in 2026 (comparable to displaced gasoline vehicle combustion emissions), but this effect rapidly drops to annual levels below 1 mtCO 2 eq per EV-year by 2032 and continues below this level through 2050. Consequential effects of EV adoption vary regionally, with most regions primarily increasing wind or solar capacity and some regions primarily increasing natural gas capacity, even in 2050. Our national emissions estimates per EV-year are relatively robust to the level of EV adoption beyond our baseline and to variation in assumptions about power systems, EV behavior, and policy.

Science & Technology - Other Topics↗

Geothermal Representation in Power System Models

Power system models generally fail to capture the range of characteristics geothermal resources provide and the value they potentially contribute to decarbonization and reliability of future electricity grids as firm, dispatchable, non-combustion power resources. This study reviews the results of power system modeling efforts to investigate geothermal deployment potential in the United States, including the U.S. DOE GeoVision analysis and ongoing modeling and analysis efforts to support planning and development of future grids with 100% renewable energy in California. Several themes are identified that could be implemented immediately to improve the accuracy of geothermal representation in power system models: consistency of model inputs, modeling of baseload and dispatchable geothermal resources, accurate valuation of grid services, improved representation of capacity factor, use of contemporary LCOE estimates, improved understanding of the evolution of geothermal value, and use of accurate resource potential constraints. Many of the models reviewed produced significantly different amounts of geothermal resource selection - even when modeling the same region and time period. This highlights the variability of inputs and assumptions among models, so creating a consistent set of geothermal inputs is a first step toward more accurate representation of geothermal in models. Research opportunities are identified that could help improve geothermal data inputs in modeling efforts, including analyses of historical data, sensitivity to model inputs, and comparative value of geothermal generators as baseload or dispatchable resources. Outcomes of such research can inform the geothermal community about how best to guide geothermal development toward wider deployment in support of future electricity grids through improved understanding of the evolution of geothermal value over time and the characteristics that contribute to that value.

capacity expansion models↗

Land of Opportunity: Potential for Renewable Energy on Federal Lands

Renewable energy (RE) in the United States has historically been deployed primarily on private lands, but the growing interest in RE development, generally across the country and specifically on federal lands, raises questions about the potential for RE on public lands. This study seeks to estimate RE technical potential on federal lands and project the amount of RE to be developed on federal lands under decarbonization scenarios for the contiguous United States. The study applied a combination of high-resolution geospatial analysis and power sector modeling and relied on multiple partner federal agencies and land administrators from the Bureau of Land Management, the U.S. Fish and Wildlife Service, the U.S. Forest Service, the U.S. Department of Defense, and the U.S. Department of Energy. In our reference siting access case, we estimate 44 million acres of federal land across the contiguous United States is potentially suitable for UPV development, which corresponds to a capacity technical potential of 5,750 gigawatts (GW) (Figure ES-1). Federal land area available for wind development is similar to UPV but wind’s generating capacity technical potential is lower (875 GW). The technical potential is estimated for two geothermal technologies, hydrothermal and enhanced geothermal systems (EGS), both of which have a smaller amount of federal land available for development (12 and 27 million acres, respectively). However, in terms of capacity, the technical potential for EGS (975 GW) is approximately equal to wind’s technical potential and there is an estimated 130 GW of hydrothermal potential. We also developed cases with more-limited land available for UPV and wind (for federal and non-federal lands) resulting in 96% reduction of wind capacity potential and 70% reduction for UPV. In a case with additional constraints applied to non-federal lands only (Limited Private), the overall (federal and non-federal) technical potential declines but the share of that technical potential on federal lands is higher than in the other siting cases. The technical potential is the maximum amount that could be developed, but only a small fraction would be developed or needed in the future. Across seven scenarios that achieve 100% carbon-free electricity by 2035, we estimate 26 GW to 270 GW of RE capacity could be deployed on federal lands by 2035. The three central scenarios have 51–84 GW of RE deployed by 2035 and requiring about 500,000 to 1,000,000 acres of total land area. Direct land consumption is less than total land use required, thus enabling co-use opportunities. The large technical potential estimates and the increasing deployment projections from the collection of scenarios show the opportunities for RE development on federal lands. Capturing these opportunities-while minimizing conflicts with other land uses, federal department or agency missions, and public interest, and simultaneously maximizing the economic, grid, and social value of the projects-would require collaborative planning among federal land administrators, grid planners, project developers, the public, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reducing Subjectivity in Geothermal Exploration Decision Making (Presentation); NREL(National Renewable Energy Laboratory)

Geothermal exploration projects have a significant amount of risk associated with uncertainties encountered in the discovery of the geothermal resource. Two of the largest challenges for increased geothermal deployment are 1) understanding when and how to proceed in an exploration program, and 2) when to walk away from a site. Current methodologies for exploration decision-making are formulatedby subjective expert opinion which can be incorrectly biased by expertise (e.g. geochemistry, geophysics), geographic location of focus, and the assumed conceptual model. The aim of this project is to develop a methodology for more objective geothermal exploration decision making at a given location, including go/no-go decision points to help developers and investors decide when to give up on alocation. In this scope, two different approaches are investigated: 1) value of information analysis (VOIA) which is used for evaluating and quantifying the value of a data before they are purchased, and 2) enthalpy-based exploration targeting based on reservoir size, temperature gradient estimates, and internal rate of return (IRR). The first approach, VOIA, aims to identify the value of aparticular data when making decisions with an uncertain outcome. This approach targets the pre-drilling phase of exploration. These estimated VOIs are highly affected by the size of the project and still have a high degree of subjectivity in assignment of probabilities. The second approach, exploration targeting, is focused on decision making during the drilling phase. It starts with a basicgeothermal project definition that includes target and minimum required production capacity and initial budgeting for exploration phases. Then, it uses average temperature gradient, reservoir temperature estimates, and production capacity to define targets and go/no-go limits. The decision analysis in this approach is based on achieving a minimum IRR at each phase of the project. This secondapproach was determined to be less subjective, since numerical inputs come from the collected data. And it helps to facilitate communication between project managers and exploration geologists in making objective go/no-go decisions throughout the different project phases.

15 GEOTHERMAL ENERGY↗

A reforecasting-based dynamic reserve estimation for variable renewable generation and demand uncertainty

The installed capacity of renewables-based energy sources has been increasing in traditional power systems. In order to accommodate the increased variability and uncertainty associated with the deeper penetration of renewable sources like solar and wind, adjusted amounts of dynamic reserve are needed. Although probabilistic dynamic reserve estimation methods have been previously developed, most of them consider the uncertainty to be represented by parametric density functions that tend to perform poorly under extreme events and, moreover, neglect uncertainty introduced by the forecasting model itself. Toward addressing these limitations, this work presents, for the first time, a dynamic reserve estimation method for flexibility that incorporates nonparametric density estimation and a machine learning based reforecasting to provide a day-ahead prediction of the mean and spread of uncertainty around the base forecast. The prediction is, in turn, used to estimate the up and down reserve relative to the base forecast. Here, the present method takes various endogenous and exogenous features, including the calendar variables, as input to estimate the day-ahead reserve. Using a combination of reforecasting and dynamic reserve estimation techniques, the method is shown to adjust better to the dynamic nature of reserve requirements providing only what is needed to accommodate the expected deviations. Considering California Independent System Operator (CAISO) solar, wind and load data over an 18 month period, up to 67% reduction in the amount of reserve capacity needed for a one day reserve and reserve penalty for solar uncertainty is demonstrated. Additionally, the risk of reserve insufficiency in meeting the net demand is reduced by 20% with the proposed method.

14 SOLAR ENERGY↗

Assessment of New Approaches in Geothermal Exploration Decision Making: Preprint

Geothermal exploration projects have significant amount of risk associated with uncertainties encountered in the discovery of the geothermal resource. Understanding when and how to proceed in an exploration program, and when to walk away from a site, are two of the largest challenges for increased geothermal deployment. Current methodologies for exploration decision making is left to subjective by subjective expert opinion which can be incorrectly biased by expertise (e.g. geochemistry, geophysics), geographic location of focus, and the assumed conceptual model. The aim of this project is to develop a methodology for more objective geothermal exploration decision making at a given location, including go-no-go decision points to help developers and investors decide when to give up on a location. In this scope, two different approaches are investigated: 1) value of information analysis (VOIA) which is used for evaluating and quantifying the value of a data before they are purchased, and 2) enthalpy-based exploration targeting based on reservoir size, temperature gradient estimates, and internal rate of return (IRR). The first approach, VOIA, aims to identify the value of a particular data when making decisions with an uncertain outcome. This approach targets the pre-drilling phase of exploration. These estimated VOIs are highly affected by the size of the project and still have a high degree of subjectivity in assignment of probabilities. The second approach, exploration targeting, is focused on decision making during the drilling phase. It starts with a basic geothermal project definition that includes target and minimum required production capacity and initial budgeting for exploration phases. Then, it uses average temperature gradient, reservoir temperature estimates, and production capacity to define targets and go/no-go limits. The decision analysis in this approach is based on achieving a minimum IRR at each phase of the project. This second approach was determined to be less subjective, since it requires less subjectivity in the input values.

15 GEOTHERMAL ENERGY↗