Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Radiometric Measurement Comparisons Using Transfer Radiometers in Support of the Calibration of NASA's Earth Observing System (EOS) Sensors

EOS satellite instruments operating in the visible through the shortwave infrared wavelength regions (from 0.4 micrometers to 2.5 micrometers) are calibrated prior to flight for radiance response using integrating spheres at a number of instrument builder facilities. The traceability of the radiance produced by these spheres with respect to international standards is the responsibility of the instrument builder, and different calibration techniques are employed by those builders. The National Aeronautics and Space Administration's (NASA's) Earth Observing System (EOS) Project Science Office, realizing the importance of preflight calibration and cross-calibration, has sponsored a number of radiometric measurement comparisons, the main purpose of which is to validate the radiometric scale assigned to the integrating spheres by the instrument builders. This paper describes the radiometric measurement comparisons, the use of stable transfer radiometers to perform the measurements, and the measurement approaches and protocols used to validate integrating sphere radiances. Stable transfer radiometers from the National Institute of Standards and Technology, the University of Arizona Optical Sciences Center Remote Sensing Group, NASA's Goddard Space Flight Center, and the National Research Laboratory of Metrology in Japan, have participated in these comparisons. The approaches used in the comparisons include the measurement of multiple integrating sphere lamp levels, repeat measurements of select lamp levels, the use of the stable radiometers as external sphere monitors, and the rapid reporting of measurement results. Results from several comparisons are presented. The absolute radiometric calibration standard uncertainties required by the EOS satellite instruments are typically in the +/- 3% to +/- 5% range. Preliminary results reported during eleven radiometric measurement comparisons held between February 1995 and May 1998 have shown the radiance of integrating spheres agreed to within +/- 2.5% from the average at blue wavelengths and to within +/- 1.7% from the average at red and near infrared wavelengths. This level of agreement lends confidence in the use of the transfer radiometers in validating the radiance scales assigned by EOS instrument calibration facilities to their integrating sphere sources.

Butler, James J.↗

Wind Tunnel Measurements of Shuttle Orbiter Global Heating with Comparisons to Flight

An aerothermodynamic database of global heating images was acquired of the Shuttle Orbiter in the NASA Langley Research Center 20-Inch Mach 6 Air Tunnel. These results were obtained for comparison to the global infrared images of the Orbiter in flight from the infrared sensing aeroheating flight experiment (ISAFE). The most recent ISAFE results from STS-103, consisted of port side images, at hypersonic conditions, of the surface features that result from the strake vortex scrubbing along the side of the vehicle. The wind tunnel results were obtained with the phosphor thermography system, which also provides global information and thus is ideally suited for comparison to the global flight results. The aerothermodynamic database includes both windward and port side heating images of the Orbiter for a range of angles of attack (20 to 40 deg), freestream unit Reynolds number (1 x 10(exp 6))/ft to 8 x 10(exp 6)/ft, body flap deflections (0, 5, and 10 deg), speed brake deflections (0 and 45 deg), as well as with boundary layer trips for forced transition to turbulence heating results. Sample global wind tunnel heat transfer images were extrapolated to flight conditions for comparison to Orbiter flight data. A windward laminar case for an angle of attack of 40 deg was extrapolated to Mach 11.6 flight conditions for comparison to STS-2 flight thermocouple results. A portside wind tunnel image for an angle of attack of 25 deg was extrapolated for Mach 5 flight conditions for comparison to STS-103 global surface temperatures. The comparisons showed excellent qualitative agreement, however the extrapolated wind tunnel results over-predicted the flight surface temperatures on the order of 5% on the windward surface and slightly higher on the portside.

Berry, Scott A.↗

SAGE III Aerosol Extinction Validation in the Arctic Winter: Comparisons with SAGE II and POAM III

The use of SAGE III multiwavelength aerosol extinction coefficient measurements to infer PSC type is contingent on the robustness of both the extinction magnitude and its spectral variation. Past validation with SAGE II and other similar measurements has shown that the SAGE III extinction coefficient measurements are reliable though the comparisons have been greatly weighted toward measurements made at mid-latitudes. Some aerosol comparisons made in the Arctic winter as a part of SOLVE II suggested that SAGE III values, particularly at longer wavelengths, are too small with the implication that both the magnitude and the wavelength dependence are not reliable. Comparisons with POAM III have also suggested a similar discrepancy. Herein, we use SAGE II data as a common standard for comparison of SAGE III and POAM III measurements in the Arctic winters of 2002/2003 through 2004/2005. During the winter, SAGE II measurements are made infrequently at the same latitudes as these instruments. We have mitigated this problem through the use potential vorticity as a spatial coordinate and thus greatly increased the number of coincident events. We find that SAGE II and III extinction coefficient measurements show a high degree of compatibility at both 1020 nm and 450 nm except a 10-20% bias at both wavelengths. In addition, the 452 to 1020-nm extinction ratio shows a consistent bias of approx. 30% throughout the lower stratosphere. We also find that SAGE II and POAM III are on average consistent though the comparisons show a much higher variability and larger bias than SAGE II/III comparisons. In addition, we find that the two data sets are not well correlated below 18 km. Overall, we find both the extinction values and the spectral dependence from SAGE III are robust and we find no evidence of a significant defect within the Arctic vortex.

Thomason, L. W.↗

Validation of TRMM Precipitation Radar Through Comparison of its Multi-Year Measurements to Ground-Based Radar

A procedure to accurately resample spaceborne and ground-based radar data is described, and then applied to the measurements taken from the Tropical Rainfall Measuring Mission (TRMM) Precipitation Radar (PR) and the ground-based Weather Surveillance Radar-1988 Doppler (WSR-88D or WSR) for the validation of the PR measurements and estimates. Through comparisons with the well-calibrated, non-attenuated WSR at Melbourne, Florida for the period 1998-2007, the calibration of the Precipitation Radar (PR) aboard the TRMM satellite is checked using measurements near the storm top. Analysis of the results indicates that the PR, after taking into account differences in radar reflectivity factors between the PR and WSR, has a small positive bias of 0.8 dB relative to the WSR, implying a soundness of the PR calibration in view of the uncertainties involved in the comparisons. Comparisons between the PR and WSR reflectivities are also made near the surface for evaluation of the attenuation-correction procedures used in the PR algorithms. It is found that the PR attenuation is accurately corrected in stratiform rain but is underestimated in convective rain, particularly in heavy rain. Tests of the PR estimates of rainfall rate are conducted through comparisons in the overlap area between the TRMM overpass and WSR scan. Analyses of the data are made both on a conditional basis, in which the instantaneous rain rates are compared only at those pixels where both the PR and WSR detect rain, and an unconditional basis, in which the area-averaged rain rates are estimated independently for the PR and WSR. Results of the conditional rain comparisons show that the PR-derived rain is about 9% greater and 19% less than the WSR estimates for stratiform and convective storms, respectively. Overall, the PR tends to underestimate the conditional mean rain rate by 8% for all rain categories, a finding that conforms to the results of the area-averaged rain (unconditional) comparisons.

Liao, Liang↗

Comparison between Hayabusa 2 Spectral Measurements and Simulations

Recent Hayabusa 2 spectral measurements are compared with state-of-the-art shock-layer radiation simulations resulting from the LAURA/HARA code suite. These simulations include coupled ablation, which accounts for the injection of ablation products into the flowfield, and coupled radiation, which accounts for radiative energy loss in the flowfield. To enable the cou- pled ablation simulations, a best-estimate model is developed for Hayabusa’s carbon-phenolic ablator based on available published information. The comparison between the simulations and measurements focuses on three atomic nitrogen lines, two atomic oxygen lines, one atomic hydrogen line, and the CN Violet band system. Parametric uncertainties are evaluated for these features using a recently developed capability in LAURA/HARA. These uncertainties capture the impact of flowfield and radiation modeling uncertainties on the observed radiation simulations, and include the impact of coupled radiation and ablation product emission. The resulting parametric uncertainties range from 50 to over 100% for the atomic lines, and 80% for CN Violet. Uncertainties in flowfield kinetics and non-Boltzmann modeling provide the dominant contribution to these uncertainties. For the atomic nitrogen and oxygen lines, com- parisons between the nominal simulations and measurements show agreement well within these simulation uncertainty bounds, with the measurements within 20% of the nominal simulation over most of the trajectory, and within 10% at peak emission. This excellent agreement is un- precedented for observed radiation measurements of atomic lines, where previous Stardust and Hayabusa 1 comparisons were significantly worse. The improved agreement for these Hayabusa 2 comparisons is both the result of improved measurement quality and enhanced flowfield and radiation modeling. For the ablation product emission from the 656 nm atomic hydrogen line, the agreement between measurements and simulations is within ±20% for all trajectory points except one outlier. This good comparison is surprising considering this species depends on the ablation rate and is shown to have strong wake contribution, which both contribute to the large ≈±70% parametric uncertainty. For the ablation product emission from CN Violet, the simulations over-predict the measurements by over a factor of two early in the trajectory, with the comparison improving later in the trajectory. This disagreement for CN Violet is consistent with the ≈±80% parametric uncertainty bounds evaluated for the simulations. To utilize the excellent agreement between the atomic line simulations and measurements in the assessment of the radiative heating margin for a future flight vehicle, the flowfield property binning (FPB) approach is applied. Using the Mars Sample Return (MSR) Earth Entry System (EES) as an example, the combination of the excellent Hayabusa comparisons and the FPB analysis justify nearly a 10% reduction in the radiative heating margin from an assumed baseline margin of 30%. This direct quantitative link between observed radiation measurements and the radia- tive heating margin of future flight vehicles demonstrates the value of these observed radiation measurements.

Shock-Layer Radiative Heating↗

Development of a Risk-Based Comparison Methodology of Carbon Capture Technologies

Given the varying degrees of maturity among existing carbon capture (CC) technology alternatives, an understanding of the inherent technical and financial risk and uncertainty associated with these competing technologies is requisite to the success of carbon capture as a viable solution to the greenhouse gas emission challenge. The availability of tools and capabilities to conduct rigorous, risk–based technology comparisons is thus highly desirable for directing valuable resources toward the technology option(s) with a high return on investment, superior carbon capture performance, and minimum risk. To address this research need, we introduce a novel risk-based technology comparison method supported by an integrated multi-domain risk model set to estimate risks related to technological maturity, technical performance, and profitability. Through a comparison between solid sorbent and liquid solvent systems, we illustrate the feasibility of estimating risk and quantifying uncertainty in a single domain (modular analytical capability) as well as across multiple risk dimensions (coupled analytical capability) for comparison. This method brings technological maturity and performance to bear on profitability projections, and carries risk and uncertainty modeling across domains via inter-model sharing of parameters, distributions, and input/output. The integration of the models facilitates multidimensional technology comparisons within a common probabilistic risk analysis framework. This approach and model set can equip potential technology adopters with the necessary computational capabilities to make risk-informed decisions about CC technology investment. The method and modeling effort can also be extended to other industries where robust tools and analytical capabilities are currently lacking for evaluating nascent technologies.

carbon capture↗

The Sim-SEQ Project: Comparison of Selected Flow Models for the S-3 Site

Sim-SEQ is an international initiative on model comparison for geologic carbon sequestration, with an objective to understand and, if possible, quantify model uncertainties. Model comparison efforts in Sim-SEQ are at present focusing on one specific field test site, hereafter referred to as the Sim-SEQ Study site (or S-3 site). Within Sim-SEQ, different modeling teams are developing conceptual models of CO2 injection at the S-3 site. In this paper, we select five flow models of the S-3 site and provide a qualitative comparison of their attributes and predictions. These models are based on five different simulators or modeling approaches: TOUGH2/EOS7C, STOMP-CO2e, MoReS, TOUGH2-MP/ECO2N, and VESA. In addition to model-to-model comparison, we perform a limited model-to-data comparison, and illustrate how model choices impact model predictions. We conclude the paper by making recommendations for model refinement that are likely to result in less uncertainty in model predictions.

Carbon sequestration↗

A study of examiner accuracy in cartridge case comparisons. Part 1: Examiner error rates

This report describes a study undertaken to estimate examiner (not laboratory) error rates for false Identifications and false Eliminations when comparing an unknown to a collection of three known cartridge cases. Volunteer active examiners with Association of Firearm and Toolmark Examiners (AFTE) membership or working in laboratories that participate in the Association of Crime Laboratory Directors (ASCLD) were provided with 15 sets of three known and one questioned cartridge cases fired from a collection of 25 new Ruger SR9 handguns. Remington 9-mm Luger (manufacturer designation L9MM3) ammunition was used and comparison sets were made up of cartridge cases fired within 100 cartridges of each other for each gun. Examiners were provided with a background survey, an answer sheet allowing for the AFTE Range of Conclusions, and return shipping materials. In addition to determining whether the known and questioned cartridge cases were fired with the same handgun, examiners were also asked to assess how many of the three knowns in each set were suitable for comparison, providing an estimated rate of how often each firearm used in the study produces useable, quality marks. The participating examiners were provided with both same-source and different-source comparison sets allowing the study to assess both error rates. Responses were received from 218 participating examiners. The overall rate of false Eliminations was estimated as 0.367% from comparisons known to be from the same firearm but reported as Eliminations. The overall rate of false Identifications was estimated as 1.01% from comparisons known to be from different firearms but reported as Identifications. The rates are not uniform across the sample population with a few examiners providing most of the false Identification responses. Rates of poor-quality mark production varied across the 25 sample handguns; those rates were 2.3% (±1.4%). Both false Elimination and false Identification rates are comparable to or lower than the rate of production of poor-quality marks by the firearms used in this study.

99 GENERAL AND MISCELLANEOUS↗

Enzyme sequence similarity improves the reaction alignment method for cross-species pathway comparison

Pathway-based information has become an important source of information for both establishing evolutionary relationships and understanding the mode of action of a chemical or pharmaceutical among species. Cross-species comparison of pathways can address two broad questions: comparison in order to inform evolutionary relationships and to extrapolate species differences used in a number of different applications including drug and toxicity testing. Cross-species comparison of metabolic pathways is complex as there are multiple features of a pathway that can be modeled and compared. Among the various methods that have been proposed, reaction alignment has emerged as the most successful at predicting phylogenetic relationships based on NCBI taxonomy. We propose an improvement of the reaction alignment method by accounting for sequence similarity in addition to reaction alignment method. Using nine species, including human and some model organisms and test species, we evaluate the standard and improved comparison methods by analyzing glycolysis and citrate cycle pathways conservation. In addition, we demonstrate how organism comparison can be conducted by accounting for the cumulative information retrieved from nine pathways in central metabolism as well as a more complete study involving 36 pathways common in all nine species. Our results indicate that reaction alignment with enzyme sequence similarity results in a more accurate representation of pathway specific cross-species similarities and differences based on NCBI taxonomy.

60 APPLIED LIFE SCIENCES↗

Comparisons between Intel 386 and i486 microprecessors

A quick and preliminary comparison is made between the Intel 386 and i486 microprocessors. The following topics are discussed: the i486 key elements, comparison of instruction set architecture, the i486 on-chip cache characteristics, the i486 multiprocessor support, comparison of performance, comparison of power consumption, comparison of radiation hardening potential, and recommendations for the Space Station Freedom (SSF) Data Management System (DMS).

Liu, Yuan-Kwei↗

Comparison of TOPEX sea surface heights and tide gauge sea levels

TOPEX sea surface height data from the first 300 days of the mission are compared to sea level data from 71 tide gauges. The initial comparison uses sea surface height data processed according to standard procedures as defined in the users handbook. It is found that the median correlations for island and for coastal tide gauges are 0.53 and 0.42, respectively. The analogous root mean square (RMS) differences between the two data sets are 7.9 and 10.4 cm. The comparisons improve significantly when a 60-day harmonic is fit to the differences and removed. This period captures aliased M(sub 2) and S(sub 2) tidal energy that is not removed by the tide model. Making this correction and smoothing the sea surface height data over 25-km along-track segments results in median correlations of 0.58 and 0.46 for the islands and coastal stations, and median RMS differences of 5.8 and 7.7 cm, respectively. Removing once per revolution signals from the sea surface heights results in degraded comparisons with the sea levels. It is also found that a number of stations have poor comparisons due to propagating signals that introduce temporal lags between the altimeter and tide gauge time series. A final comparison is made by eliminating stations where this propagation effect is large, discarding two stations that are suspected to have problems with the sea level data, smoothing over 10-day intervals, and restricting attention to islands gauges. This results in a set of 552 data pairs that have a correlation of 0.66 and a RMS difference of 4.3 cm. The conclusion is that on timescales longer than about 10 days the RMS sea surface height errors are less than or of the order of several centimeters.

Mitchum, Gary T.↗

Airborne Sunphotometer Measurements of Aerosol Optical Depth and Water Vapor in ACE-Asia and Their Comparisons to Correlative Measurements

In the Spring 2001 phase of the Asian Pacific Regional Aerosol Characterization Experiment (ACE-Asia), the 6-channel NASA Ames Airborne Tracking Sunphotometer (AATS-6) operated on 15 of the 19 research flights of the NCAR C-130, while its 14-channel counterpart (AATS-14) flew successfully on all 19 research flights of the CIRPAS Twin Otter. ACE-Asia studied aerosol outflow from the Asian continent to the Pacific basin. It was designed to integrate suborbital and satellite measurements and models to reduce the uncertainty in calculations of the climate forcing due to aerosols. AATS-6 and AATS-14 measured solar beam transmission at six and 14 wavelengths (380-1021 and 354-1558 nm, respectively), yielding aerosol optical depth (AOD) spectra and columnar water vapor (CWV). Vertical differentiation in profiles yielded aerosol extinction spectra and water vapor concentration. In this paper, we plan to present examples of the following, preliminary findings that are based in part on our airborne sunphotometer measurements: (1) The wavelength dependence of sunphotometer-derived AOD and extinction indicates that supermicron dust was often a major component of the aerosol, frequently extending to high altitudes. The percentage of full-column AOD (525 nm) that Jay above 3 km was typically 34+/-13%. In contrast, the analogous percentage of columnar water vapor was only 10+/-4%; (2) Initial comparison studies between AOD data obtained by AATS-6 and AATS-14 during coordinated low-level flight legs show agreement well within the instruments' error bars; (3) Aerosol extinction has been derived from airborne in situ measurements of scattering (nephelometers) and absorption (particle soot/ absorption photometer, PSAP) or calculated from particle size distribution measurements (mobility analyzers and aerodynamic particle sizers). Comparison with corresponding extinction values derived from the Ames airborne sunphotometer measurements shows good agreement for the vertical distribution of aerosol layers. However, the level of agreement in absolute magnitude of the derived aerosol extinction/optical depth varied among the aerosol layers sampled; (4) Initial comparisons of sunphotometer and satellite-derived AOD using SeaWiFS, MISR and AVHRR show promising results. We also plan to include comparisons with MODIS and TOMS: (5) Initial comparisons of sunphotometer-derived AOD and aerosol extinction profiles with lidars in Tokyo and on a ship show reasonable agreement.

Schmid, B.↗

Comparisons of Instantaneous TRMM Ground Validation and Satellite Rain Rate Estimates at Different Spatial Scales

This study provides a comprehensive inter-comparison of instantaneous rain estimates from the two rain sensors aboard the TRMM satellite with ground data from thee designated Ground Validation Sites: Kwajalein Atoll, Melbourne, Florida and Houston, Texas. The satellite rain retrievals utilize rain observations collected by the TRMM microwave imager (TMI) and the Precipitation Radar (PR) aboard the TRMM satellite. Three standard instantaneous rain products are the generated from the rain information retrieved from the satellite using the TMI, PR and Combined (COM) rain algorithms. The validation data set used in this study was obtained from instantaneous rain rates inferred from ground radars at each GV site. The first comparison used 0.5(sup 0) x 0.5(sup 0) gridded data obtained from the TRMM 3668 product, and similarly gridded GV data obtained from ground-based radars. The comparisons were made at the same spatial and temporal scales in order to eliminate sampling biases in our comparisons. An additional comparison was made by averaging rain rates for the PR, COM and GV estimates within each TMI footprint (approx. 150 square kilometers). For this analysis, unconditional mean rain rates from PR, COM and GV estimates were calculated within each TMI footprint that was observed within 100 km from the respective GV site (and also observed by the PR). This analysis used all the available matching data from the period 1999-2004, representing a sample size of over 50,000 footprints for each site. In the first analysis our results showed that all of the respective rain rate estimates agree well, with some exceptions. The more salient differences were associated with heavy rain events in which one or more of the algorithms failed to properly retrieve these extreme events. Also, it appears that there is a preferred mode of precipitation for TMI rain rates at or near 2 mm per hour over the ocean. This mode was noted over ocean areas of Melbourne, Florida and Kwajalein, Republic of the Marshall Islands, and is shown to exist in TRMM tropical-global ocean areas as well. Further research by algorithm developers is needed to explain or justify the seemingly errant observed probability distributions.

Wolff, David B.↗

Comparison of ORSAT and SCARAB Reentry Analysis Tools for a Generic Satellite Test Case

Reentry analysis is essential to understanding the consequences of the full life cycle of a spacecraft. Since reentry is a key factor in spacecraft development, NASA and ESA have separately developed tools to assess the survivability of objects during reentry. Criteria such as debris casualty area and impact energy are particularly important to understanding the risks posed to people on Earth. Therefore, NASA and ESA have undertaken a series of comparison studies of their respective reentry codes for verification and improvements in accuracy. The NASA Object Reentry Survival Analysis Tool (ORSAT) and the ESA Spacecraft Atmospheric Reentry and Aerothermal Breakup (SCARAB) reentry analysis tools serve as standard codes for reentry survivability assessment of satellites. These programs predict whether an object will demise during reentry and calculate the debris casualty area of objects determined to survive, establishing the reentry risk posed to the Earth's population by surviving debris. A series of test cases have been studied for comparison and the most recent uses "Testsat," a conceptual satellite composed of generic parts, defined to use numerous simple shapes and various materials for a better comparison of the predictions of these two codes. This study is an improvement on the others in this series because of increased consistency in modeling techniques and variables. The overall comparison demonstrated that the two codes arrive at similar results. Either most objects modeled resulted in close agreement between the two codes, or if the difference was significant, the variance could be explained as a case of semantics in the model definitions. This paper presents the main results of ORSAT and SCARAB for the Testsat case and discusses the sources of any discovered differences. Discussion of the results of previous comparisons is made for a summary of differences between the codes and lessons learned from this series of tests.

Kelley, Robert L.↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

Role and Evaluation of Interlaboratory Comparison Results in Laboratory Accreditation

Participation in interlaboratory comparisons provides laboratories an opportunity for independent assessment of their analytical performance, both in absolute way and in comparison with those by other techniques. However, such comparisons are hindered by differences in the way laboratories participate, e.g. at best measurement capability or under routine conditions. Neutron activation analysis laboratories, determining total mass fractions, often see themselves classified as 'outliers' since the majority of other participants employ techniques with incomplete digestion methods. These considerations are discussed in relation to the way results from interlaboratory comparisons are evaluated by accreditation bodies following the requirements of Clause 5.9.1 of the ISO/IEC 17025:2005. The discussion and conclusions come largely forth from experiences in the author's own laboratory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Blazing Signature Filter: a library for fast pairwise similarity comparisons

Identifying similarities between datasets is a fundamental task in data mining and has become an integral part of modern scientific investigation. Whether the task is to identify co-expressed genes in large-scale expression surveys or to predict combinations of gene knockouts which would elicit a similar phenotype, the underlying computational task is often a multi-dimensional similarity test. As datasets continue to grow, improvements to the efficiency, sensitivity or specificity of such computation will have broad impacts as it allows scientists to more completely explore the wealth of scientific data. A significant practical drawback of large-scale data mining is the vast majority of pairwise comparisons are unlikely to be relevant, meaning that they do not share a signature of interest. It is therefore essential to efficiently identify these unproductive comparisons as rapidly as possible and exclude them from more time-intensive similarity calculations. The Blazing Signature Filter (BSF) is a highly efficient pairwise similarity algorithm which enables extensive data mining within a reasonable amount of time. The algorithm transforms datasets into binary metrics, allowing it to utilize the computationally efficient bit operators and provide a coarse measure of similarity. As a result, the BSF can scale to high dimensionality and rapidly filter unproductive pairwise comparison. Furthermore, two bioinformatics applications of the tool are presented to demonstrate the ability to scale to billions of pairwise comparisons and the usefulness of this approach.

59 BASIC BIOLOGICAL SCIENCES↗

National Renewable Energy Laboratory Pyrheliometer Comparisons: 24 September - 5 October 2012 (NPC-2012)

The NREL Pyrheliometer Comparisons for 2012 (NPC-2012) were held at the Solar Radiation Research Laboratory in Golden, Colorado, from September 24 through October 5 for the purpose of transferring the World Radiometric Reference (WRR) to participating instrument. Twenty scientists and engineers operated 32 absolute cavity radiometers and 18 conventional thermopile-based pyrheliometers to simultaneously measure clear-sky direct normal irradiance during the comparisons. The transfer standard group of reference radiometers for NPC-2012 consisted of four NREL radiometers with direct traceability to the WRR, having participated in the Eleventh International Pyrheliometer Comparisons (IPC-XI) hosted by the World Radiation Center in the fall of 2010. As the result of NPC-2012, each participating absolute cavity radiometer was assigned a new WRR transfer factor, computed as the reference irradiance computed by the transfer standard group divided by the observed irradiance from the participating radiometer. The performance of the transfer standard group during NPC-2012 was consistent with previous comparisons, including IPC-XI. The measurement performance of the transfer standard group allowed the transfer of the WRR to each participating radiometer with an estimated uncertainty of +/- 0.33% with respect to the International System of Units.

14 SOLAR ENERGY↗