Design considerations for the beamwaveguide retrofit of a ground antenna station

A primary requirement of the NASA Deep Space Network (DSN) is to provide for optimal reception of very low signal levels. This requirement necessitates optimizing the antenna gain to the total system operating noise level quotient. Low overall system noise levels of 16 to 20 K are achieved by using cryogenically cooled preamplifiers closely coupled with an appropriately balanced antenna gain/spillover design. Additionally, high-power transmitters (up to 400 kW CW) are required for spacecraft emergency command and planetary radar experiments. The frequency bands allocated for deep space telemetry are narrow bands near 2.1 and 2.3 GHz (Ka-band), 7.1 and 8.4 GHz (X-band), and 32 and 34.5 GHz (Ka-band). In addition, planned operations for the Search for Extraterrestrial Intelligence (SETI) program require continuous low-noise receive coverage over the 1 to 10 GHz band. To summarize, DSN antennas must operate efficiently with low receive noise and high-power uplink over the 1 to 35 GHz band.

Veruttipong, T.↗

The SIRTF mission

This paper describes the scientific and technical background and prospects for the Space Infrared Telescope Facility (SIRTF). SIRTF is a cryogenically-cooled, one meter-class space telescope which will be operated by NASA as an observatory for infrared astronomy, in the mid-1990's. SIRTF will provide detailed studies of even the faintest IRAS sources, important new capabilities for the study of known astrophysical phenomena, and the potential to make new and unexpected discoveries about the nature of the universe. The long-life SIRTF mission has undergone intensive review by the SIRTF Science Working Group, which was selected in mid-1984. This paper presents the outcome of that review process and describes the SIRTF program as it is now envisioned. Particular emphasis will be placed on the choice of orbit for SIRTF, the SIRTF scientific performance requirements, and the baseline design concept for the SIRTF facility and mission.

Werner, Michael W.↗

An analytical and experimental investigation of resistojet plumes

As a part of the electrothermal propulsion plume research program at the NASA Lewis Research Center, efforts have been initiated to analytically and experimentally investigate the plumes of resistojet thrusters. The method of Simons for the prediction of rocket exhaust plumes is developed for the resistojet. Modifications are made to the source flow equations to account for the increased effects of the relatively large nozzle boundary layer. Additionally, preliminary mass flux measurements of a laboratory resistojet using CO2 propellant at 298 K have been obtained with a cryogenically cooled quartz crystal microbalance (QCM). There is qualitative agreement between analysis and experiment, at least in terms of the overall number density shape functions in the forward flux region.

Zana, Lynnette M.↗

Optimization of V-groove radiator configuration

In the design of spacecraft radiators intended to provide cryogenic cooling, it is important to minimize the space occupied by radiator shielding while satisfying the performance requirements. This study develops and tests the first step toward optimizing radiator shield configurations and examines the design of the highly effective V-groove radiator concept. This investigation, which makes use of a special purpose Monte Carlo/ray tracing computer program, directly identifies the two shield configuration which minimizes radiator footprint for a given temperature drop. Furthermore, multiple shield configurations may be analyzed through a combination of analysis and program statistics. The results presented demonstrate the sensitivity of intershield temperature drop to shield angle and/or offset and provide a comparison of angled and parallel shield configurations. Good agreement with experimental data is shown for a multiple shield configuration.

Schember, Helene R.↗

Simultaneous measurement of stratospheric O3, H2O, CH4, and N2O profiles from infrared limb thermal emissions

Thermal emission measurements of the earth's stratospheric limb were made with a cryogenically cooled high-resolution Michelson interferometer on a balloon flight launched from Palestine, TX, on Nov. 6, 1984. Infrared spectra for complete limb sequences were obtained over portions of the 700-1940/cm range with an unapodized spectral resolution of 0.03/cm for tangent heights varying from 13 to 39 km. The observed data from 1125 to 1425/cm have been analyzed for simultaneous measurement of O3, H2O, CH4, and N2O profiles. The analysis employs line-by-line and layer-by-layer radiative-transfer calculations, including curvature and refraction effects. The optimum use of geometric and spectral effects is made to obtain sharply peaked weighting functions. Contributions from stratospheric aerosol are included by measuring the light extinction within the window regions of the observed spectra. The retrieved constituent profiles are compared with measurements made with a variety of techniques by other groups. The comparison shows good agreement with the published data for all gases, indicating the capability of retrieving trace gas profiles from high-resolution thermal emission limb measurements.

Abbas, M. M.↗

Effect of nozzle geometry on the resistojet exhaust plume

Five nozzle configurations were used to study the effect of geometry on the plume structure of a resistojet exhausting into a vacuum. Mass flux data in the forward and back flux regions were obtained with a cryogenically cooled quartz crystal microbalance. The propellant used was CO2 at 300 K and a mass flow rate of 0.2 g/s. The data reveal that the percent of mass flow contained within half angles of 10, 30, and 40 deg varied by less than 12 percent from a standard 20 deg half-angle cone nozzle.

Breyley, Loranell↗

Low-noise cryogenic transmission line

New low-noise cryogenic input transmission lines have been developed for the Deep Space Network (DSN) at 1.668 GHz for cryogenically cooled Field Effect Transistors (FET) and High Electron Mobility Transistor (HEMT) amplifiers. These amplifiers exhibit very low noise temperatures of 5 K to 15 K, making the requirements for a low-noise input transmission line critical. Noise contribution to the total amplifier system from the low-noise line is less than 0.5 K for both the 1.668-GHz and 2.25-GHz FET systems. The 1.668-GHz input line was installed in six FET systems which were implemented in the DSN for the Venus Balloon Experiment. The 2.25-GHz input line has been implemented in three FET systems for the DSN 34-m HEF antennas, and the design is currently being considered for use at higher frequencies.

Norris, D.↗

Traveling-wave maser closed-cycle refrigerator data acquisition and display system

A data acquisition and display system that automatically monitors the performance of the 4.5-K closed-cycle refrigerators used to cryogenically cool traveling-wave masers is described. The system displays and stores operating parameters for the purpose of providing status information, failure prediction, and analysis. A prototype of this system will be installed at Deep Space Network 12 in the near future. The advantages of using commercial data acquisition hardware with installed operating systems and BASIC programs for this application are discussed.

Fowler, L.↗

Study of helium transfer technology for STICCR: Fluid management

The Space Infrared Telescope Facility (SIRTF) is a long life cryogenically cooled space based telescope for infrared astronomy from 2 to 700 microns currently under study and planned for launch in the mid 90's. SIRTF will operate as a multi-user facility, initially carrying 3 instruments at the focal plane. It will be cooled to below 2 K by superfluid liquid helium to achieve radiometric sensitivity limited only by the statistical fluctuations in the natural infrared background radiation over most of its spectral range. The lifetime of the mission will be limited by the lifetime of the liquid helium supply, and is currently baselined to be 2 years. Candidates are reviewed for a liquid management device to be used in the resupply of liquid helium, and for the selection of an appropriate candidate.

Frank, D. J.↗

X-band system performance of the very large array

The Very Large Array (VLA) is being equipped to receive telemetry from Voyager 2 during the Neptune encounter in 1989. Cryogenically cooled amplifiers are being installed on each of the 27 antennas. These amplifiers are currently a mix of field effect transistors (FETs) and high electron mobility transistors (HEMTs) and exhibit zenith system temperatures that range from 30 to 52 K. The system temperatures and aperture efficiencies determined during the past year are summarized. The nominal values of the noise diode calibration are compared with derived values made under the assumption of a uniform atmosphere over the array. Gain values are determined from observations of unresolved radio sources whose flux densities are well known. The tests suggest that the completed VLA will have a ratio of gain to system temperature that is approximately 4.4 dB above that of a single 64 m antenna of the Deep Space Network.

Ulvestad, J. S.↗

A 2.3-GHz low-noise cryo-FET amplifier

A cryogenic cooled, low-noise Field Effect Transistor (FET) amplifier assembly for use at 2.2 to 2.3 GHz was developed for the DSN to meet the requirements of a Very Long Baseline Interferometry (VLBI) upgrade. An amplifier assembly was developed at JPL that uses a commercial closed-cycle helium refrigerator (CCR) to cool a FET amplifier to an operating temperature of 15 K. A cooled probe waveguide-to-coaxial transition similar to that used in the research and development Ultra-Low-Noise S-band Traveling Wave Maser (TWM) is used to minimize input line losses. Typical performance includes an input flange equivalent noise contribution of 14.5 K, a gain slope of less than 0.05 dB/MHz across a bandwidth of 2.2 to 2.3 GHz, an input VSWR of 1.5:1 at 2.25 GHz, and an insertion gain of 45 + or - 1 dB across the bandwidth of 2.2 to 2.3 GHz. Three 2.3 GHz FET/CCR assemblies were delivered to the DSN in the spring of 1987.

Loreman, J.↗

Development in tunable solid state lasers with high spectral purity, high efficiency and long lifetime for differential absorption lidar

The paper presents a review of tunable vibronic solid state lasers for DIAL measurements and provides new experimental results for tunable Ti:sapphire lasers, materials development, and spectral bandwidth narrowing through injection control. Pulsed injection control of a Ti:sapphire laser with a 2.5-pm narrow band pulsed dye laser and with another Ti:sapphire laser is demonstrated with nearly complete energy extraction, indicating homogeneous line broadening. The status of tunable solid state lasers in the 1.6-2.3 micron range for DIAL measurements of trace gases, and development trends for lasers with reduced cryogenic cooling needs, are included. The effects of laser gain on optical damage, energy extraction, and amplified spontaneous emission are indicated for several tunable lasers.

Hess, R. V.↗

Review on drop towers and long drop tubes

A drop tube is an enclosure in which a molten sample can be solidified while falling; three such large tubes are currently in existence, all at NASA research facilities, and are engaged in combustion and fluid physics-related experiments rather than in materials research. JPL possesses smaller tubes, one of which can be cryogenically cooled to produce glass and metal microshells. A new small drop tube will soon begin operating at NASA Lewis that is equipped with four high-speed two-color pyrometers spaced equidistantly along the column.

Bayuzick, R. J.↗

Submillimeter heterodyne receiver for the CSO telescope

This task is to build a cryogenically cooled 620 to 700 GHz astronomical receiver that will be used as a facility instrument at the CalTech Submillimeter Observatory (CSO) on Mauna Kea, Hawaii. The receiver will have applications as a very high resolution spectrometer to investigate spectral lines in planetary and satellite atmospheres, and comets. The receiver will also be used to make continuum measurements of planets, satellites, and asteroids. During FY88, a scale model (200 GHz) SIS mixer radiometer was built and intrgrated into a cryostat designed for use on the CSO telescope. This system will serve as a model to guide the work on the higher frequency mixer. A solid state local oscillator source that covers two bands in the 600 to 700 GHz has been developed under contract JPL and will be delivered before the end of the year. Work has continued on the SIS materials needed for the 620 to 700 GHz mixer. Test hardware has been developed which allow the 1 to 5 curves for SIS material to be easily measured.

Gulkis, S.↗

SIRTF Telescope Instrument Changeout and Cryogen Replenishment (STICCR) Study

The Space Infrared Telescope Facility (SIRTF) is a long-life cryogenically cooled space-based telescope for infrared astronomy from 2 to 700 micrometers. SIRTF is currently under study by NASA-ARC (Reference AP) and planned for launch in approximately the mid 1990s. SIRTF will operate as a multiuser facility, initially carrying three instruments at the focal plane. It will be cooled to below 2 K by superfluid liquid helium to achieve radiometric sensitivity limited only by the statistical fluctuations in the natural infrared background radiation over most of its spectral range. The lifetime of the mission will be limited by the lifetime of the liquid helium supply, and baseline is currently to be 2 years. The telescope changes required to allow in-space replenishment of the 4,000-L superfluid helium tank was investigated. A preliminary design for the space services equipment was also developed. The impacts of basing the equipment and servicing on the space station were investigated. Space replenishment and changeout of instruments required changes to the telescope design. Preliminary concepts are presented.

Nast, T. C.↗

High dynamic range infrared radiometry and imaging

The use is described of cryogenically cooled, extrinsic silicon infrared detectors in an unconventional mode of operation which offers an unusually large dynamic range. The system performs intensity-to-frequency conversion at the focal plane via simple circuits with very low power consumption. The incident IR intensity controls the repetition rate of short duration output pulses over a pulse rate dynamic range of about 10(6). Theory indicates the possibility of monotonic and approx. linear response over the full dynamic range. A comparison between the theoretical and the experimental results shows that the model provides a reasonably good description of experimental data. Some measurements of survivability with a very intense IR source were made on these devices and found to be very encouraging. Evidence continues to indicate that some variations in interpulse time intervals are deterministic rather than probabilistic.

Coon, Darryl D.↗

Feasibility of an uncooled imaging spectrometer for the exploration of the solar system

A state-of-the-art imaging spectrometer concept is presented for visible-midwavelength IR spectral region studies of the solar system that obviates the until-now essential use of cryogenic cooling. This uncooled imaging spectrometer configuration is evaluated in view of the prospective environments of the instrument in various spacecraft orbits, as well as in light of various available photodetector materials and sensor focal plane array configurations.

Liaw, H. M.↗

X-ray fluorescence analysis of alloy and stainless steels using a mercuric iodide detector

A mercuric iodide detector was used for the XRF analysis of a number of NBS standard steels, applying a specially developed correction method for interelemental effects. It is shown that, using this method and a good peak-deconvolution technique, the HgI2 detector is capable of achieving resolutions and count rates needed in the XRF anlysis of multielement samples. The freedom from cryogenic cooling and from power supplies necessary for an electrically cooled device makes this detector a very good candidate for a portable instrument.