Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Dealing with Ion LET Uncertainties: An Application of Generalized Linear Models

Although most SEE rate estimation methods presume a fit to SEE cross section vs. LET, fitting SEE data is challenging because the data are not compatible with the assumptions of many common fitting techniques (e.g. linear regression. The difficulty of fitting such data is compounded when the LET of the ion responsible for an SEE is uncertain. We modify a Generalized Linear Model SEE data fitting methodology to accommodate uncertain LET and apply the method to the problem of backside heavy-ion SEE testing to demonstrate the utility of the method, explore the dependence of systematic errors that arise from improper treatment of LET uncertainty and develop guidelines for minimizing such systematic errors when proper treatment is not possible. Additional applications are suggested and assessed for suitability of treatment by the model.

Single-event effects↗

Fitting Prony Series To Data On Viscoelastic Materials

Improved method of fitting Prony series to data on viscoelastic materials involves use of least-squares optimization techniques. Based on optimization techniques yields closer correlation with data than traditional method. Involves no assumptions regarding the gamma'(sub i)s and higher-order terms, and provides for as many Prony terms as needed to represent higher-order subtleties in data. Curve-fitting problem treated as design-optimization problem and solved by use of partially-constrained-optimization techniques.

Hill, S. A.↗

Combined fit of spectrum and composition data as measured by the Pierre Auger Observatory

In this paper, we present a combined fit of a simple astrophysical model of UHECR sources to both the energy spectrum and mass composition data measured by the Pierre Auger Observatory. The fit has been performed for energies above 5 • 10 18 eV, i.e. the region of the all-particle spectrum above the so-called 'ankle' feature. The astrophysical model we adopted consists of identical sources uniformly distributed in a comoving volume, where nuclei are accelerated through a rigidity-dependent mechanism. The fit results suggest sources characterized by relatively low maximum injection energies, hard spectra and heavy chemical composition. We also show that uncertainties about physical quantities relevant to UHECR propagation and shower development have a non-negligible impact on the fit results.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmic ray studies with a gas Cherenkov counter in association with an ionization spectrometer

The results from a balloon-borne gas Cherenkov counter (threshold 16.5 GeV/nucleon) and an ionization spectrometer are presented. The gas Cherenkov counter provides an absolute energy distribution for the response of the calorimeter for 5 or = Z 26 nuclei of cosmic rays. The contribution of scintillation to the gas Cherenkov pulse height was obtained by independently selecting particles below the gas Cherenkov threshold using the ionization spectrometer. Energy spectra were derived by minimizing the chi squared between Monte Carlo simulted data and flight data. Best fit power laws, dN/dE = AE-gamma, were determined for C, N, O, Ne, Mg, and Si. The power laws, all consistent with E (-2.7) are not good fits to the data. A better fit is obtained using the spectrum derived from the spectrometer. The data from the ionization calorimeter and the gas Cherenkov are thus completely self-consistent.

Balasubrahmanyan, V. K.↗

Use of event-level neutrino telescope data in global fits for theories of new physics

We present a fast likelihood method for including event-level neutrino telescope data in parameter explorations of theories for new physics, and announce its public release as part of DarkSUSY 5.0.6. Our construction includes both angular and spectral information about neutrino events, as well as their total number. We also present a corresponding measure for simple model exclusion, which can be used for single models without reference to the rest of a parameter space. We perform a number of supersymmetric parameter scans with IceCube data to illustrate the utility of the method: example global fits and a signal recovery in the constrained minimal supersymmetric standard model (CMSSM), and a model exclusion exercise in a 7-parameter phenomenological version of the MSSM. The final IceCube detector configuration will probe almost the entire focus-point region of the CMSSM, as well as a number of MSSM-7 models that will not otherwise be accessible to e.g. direct detection. Our method accurately recovers the mock signal, and provides tight constraints on model parameters and derived quantities. We show that the inclusion of spectral information significantly improves the accuracy of the recovery, providing motivation for its use in future IceCube analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Rate Equations for Reversible Disproportionation Reactions and Fitting to Time-Course Data

Integrated rate equations are straightforward to fit to experimental data to verify a proposed mechanism and to extract kinetic parameters. Such equations are derived for reversible disproportionation/comproportionation reactions with any set of initial concentrations. Extraction of forward and reverse rate constants from experimental data by fitting the rate law to the data is demonstrated for the disproportionation of 2,2,6,6-tetramethyl-1-piperidinyl-N-oxyl (TEMPO) under acidic conditions where the approach to equilibrium is observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beyond traditional diagnostics: Identifying active galactic nuclei using spectral energy distribution fitting in DESI data

Active galactic nuclei (AGN) are typically identified through their distinctive X-ray or radio emissions, mid-infrared (MIR) colors, or emission lines. However, each method captures different subsets of AGN due to signal-to-noise (S/N) limitations, redshift coverage, and extinction effects, underscoring the necessity for a multiwavelength approach for comprehensive AGN samples. This study explores the effectiveness of spectral energy distribution (SED) fitting as a robust method for AGN identification. Using CIGALE optical-MIR SED fits on DESI Early Data Release galaxies, we compare SED-based AGN selection (AGNFRAC ≥ 0.1) with traditional methods including BPT diagrams, WISE colors, X-ray, and radio diagnostics. The SED fitting identifies ∼70% of narrow- and broad-line AGN and 87% of WISE-selected AGN. Incorporating high S/N WISE photometry reduces star-forming galaxy contamination from 62% to 15%. Initially, ∼50% of SED-AGN candidates are undetected by standard methods, but additional diagnostics classify ∼85% of these sources, revealing low-ionization nuclear emission-line regions and retired galaxies potentially representing evolved systems with weak AGN activity. Further spectroscopic and multiwavelength analysis will be essential to determine the true AGN nature of these sources. SED fitting provides complementary AGN identification, unifying multiwavelength AGN selections. This approach enables more complete – albeit somewhat contaminated – AGN samples, which are essential for upcoming large-scale surveys where spectroscopic diagnostics may be limited.

Seyfert↗

Relativistic precessing jets in quasars and radio galaxies - Models to fit high resolution data

The formulation of generalized models tracing the geometry and intensity of the synchrotron emission from precessing, twin, relativistic jets as projected on the plane of the sky is presented. It is shown that neither the shape of the image nor its relative intensities are altered by including the effects of a cosmological redshift and a relative velocity between the source and observer. The models are fitted to the available data for several quasars and radio galaxies and demonstrate the plausibility of the phenomenon. Probable selection effects are considered and diagnostics given for recognizing objects showing this behavior. In the radio galaxies considered, velocities up to about 0.2c and precession periods of 1,000,000 yr are deduced. In the QSOs investigated, velocities of 0.7c and greater are found and periods of order 10,000 yr. In some cases precession cone angles increase with time. Consequences in terms of lifetimes of QSO behavior and binary supermassive objects are discussed.

Gower, A. C.↗

Cosmic ray studies with a gas Cerenkov counter in association with an ionization spectrometer

The results from a balloon-borne gas Cerenkov counter (threshold 16.5 GeV/nuc) and an ionization spectrometer are presented. The gas Cerenkov counter provides an absolute energy calibration for the response of the calorimeter for the Z range of 5-26 nuclei of cosmic rays. The contribution of scintillation to the gas Cerenkov pulse height has been obtained by independently selecting particles below the gas Cerenkov threshold using the ionization spectrometer. Energy spectra were derived by minimizing the chi-squared between a Monte Carlo simulated data and flight data. Best fit power laws were determined for C, N, O, Ne, Mg, and Si. The power laws, all consistent with E exp-2.7, are not good fits to the data. A better fit is obtained using the spectrum derived from the spectrometer.

Balasubrahmanyan, V. K.↗

A Numerical Method for Calculating Stellar Occultation Light Curves from an Arbitrary Atmospheric Model

We present a method for speeding up numerical calculations of a light curve for a stellar occultation by a planetary atmosphere with an arbitrary atmospheric model that has spherical symmetry. This improved speed makes least-squares fitting for model parameters practical. Our method takes as input several sets of values for the first two radial derivatives of the refractivity at different values of model parameters, and interpolates to obtain the light curve at intermediate values of one or more model parameters. It was developed for small occulting bodies such as Pluto and Triton, but is applicable to planets of all sizes. We also present the results of a series of tests showing that our method calculates light curves that are correct to an accuracy of 10(exp -4) of the unocculted stellar flux. The test benchmarks are (i) an atmosphere with a l/r dependence of temperature, which yields an analytic solution for the light curve, (ii) an atmosphere that produces an exponential refraction angle, and (iii) a small-planet isothermal model. With our method, least-squares fits to noiseless data also converge to values of parameters with fractional errors of no more than 10(exp -4), with the largest errors occurring in small planets. These errors are well below the precision of the best stellar occultation data available. Fits to noisy data had formal errors consistent with the level of synthetic noise added to the light curve. We conclude: (i) one should interpolate refractivity derivatives and then form light curves from the interpolated values, rather than interpolating the light curves themselves; (ii) for the most accuracy, one must specify the atmospheric model for radii many scale heights above half light; and (iii) for atmospheres with smoothly varying refractivity with altitude, light curves can be sampled as coarsely as two points per scale height.

Chamberlain, D. M.↗

A Monte Carlo investigation of experimental data requirements for fitting polynomial functions

This report examines the extent to which sample size affects the accuracy of a low order polynomial approximation of an experimentally observed quantity and establishes a trend toward improvement in the accuracy of the approximation as a function of sample size. The task is made possible through a simulated analysis carried out by the Monte Carlo method, in which data are generated by using several transcendental or algebraic functions as models. Contaminated data of varying amounts are fitted to linear quadratic or cubic polynomials, and the behavior of the mean-squared error of the residual variance is determined as a function of sample size. Results indicate that the effect of the size of the sample is significant only for relatively small sample sizes and diminishes drastically for moderate and large amounts of experimental data.

Canavos, G. C.↗

Metafitting: Weight optimization for least-squares fitting of PTTI data

For precise time intercomparisons between a master frequency standard and a slave time scale, we have found it useful to quantitatively compare different fitting strategies by examining the standard uncertainty in time or average frequency. It is particularly useful when designing procedures which use intermittent intercomparisons, with some parameterized fit used to interpolate or extrapolate from the calibrating intercomparisons. We use the term 'metafitting' for the choices that are made before a fitting procedure is operationally adopted. We present methods for calculating the standard uncertainty for general, weighted least-squares fits and a method for optimizing these weights for a general noise model suitable for many PTTI applications. We present the results of the metafitting of procedures for the use of a regular schedule of (hypothetical) high-accuracy frequency calibration of a maser time scale. We have identified a cumulative series of improvements that give a significant reduction of the expected standard uncertainty, compared to the simplest procedure of resetting the maser synthesizer after each calibration. The metafitting improvements presented include the optimum choice of weights for the calibration runs, optimized over a period of a week or 10 days.

Douglas, Rob J.↗

LOFTID Heat Flux Gauge Calibration: What is Truth?

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is a demonstration of Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which may enable the delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the size of the rocket’s shroud, inflatable aeroshells can be deployed to a much larger scale, thus allowing a spacecraft to begin its deceleration earlier and experience less heating. On LOFTID, there will be 4 total heat flux gauges (HFG) with a range of 70 W/cm2 and 1 radiometer with a range of 3 W/cm2, arranged as shown in Fig. 1. Both the radiometer and total HFGs are Schmidt-Boelter gauges purchased from an external vendor. Radiative calibrations were performed in-house at NASA Ames’ Sensors and TPS Advanced Research Laboratories (STAR Labs) before and after environmental testing to investigate how the testing affected the sensors' response. Additional rounds of radiative calibration at STAR Labs were also performed in order to investigate the large uncertainties associated with these tests. For example, a survey of multiple calibration facilities concluded that the uncertainty within a given facility was +/-3% [1]. An additional NIST study that calibrated heat flux gauges at 7 different facilities also found the variation in calibration coefficients to be up to ~3% within a given facility, but up to 15% between facilities, suggesting systematic differences between test setups [2]. Finally, the response of heat flux gauges to radiative versus convective heat flux has shown to differ by up to 20% [3],[4]. Because the heat flux gauges on LOFTID will predominantly experience convective heat flux during flight, a convective calibration study was performed at Boeing's Large-Core Arc Tunnel (LCAT) facility. Radiative Calibration Procedure The calibrations performed at STAR Labs utilize a quartz lamp bank (QLB) that provides a maximum heat flux of 50 W/cm2, which bounds the expected LOFTID flight environment. The calibration involves exposing a water-cooled Gardon gauge (reference) and then the unit-under-test (UUT) to 5 different heat fluxes multiple times for 10 seconds each, and then calculating a linear fit. The test setup is shown in Fig. 2. The total HFGs were calibrated at STAR Labs 3 times, denoted as STAR 1 (before environmental testing), STAR 2 (after protoflight vibration and thermal-vacuum testing), and STAR 3 (no change from previous test). All 8 flight-lot total HFGs showed a decrease in full-scale output from STAR 1 to STAR 2 by between 0.5% and 10. The first portion of this investigation was to determine whether the change could be due to differences in temperature between the two calibration runs. A typical linear fit to the calibration data was performed using Eq. 1 where q’ is the heat flux in W/cm2, c is the calibration coefficient, and mV is the sensor output. To account for temperature, the data were fit to a nonlinear function that included both the sensor output (mV) and the temperature from the thermocouple embedded inside the HFG near the surface (T): q'=mV/(c1* T + c0}. The residuals between the fits and the actual data points were calculated for every point, and proven to be much smaller for the temperature-compensated fits than for the linear fits for all sensors. An example is shown in Fig. 3. When the temperature-compensated fits from STAR 1 were applied to the STAR 2 data, the residuals did not improve, suggesting that the change in sensitivity between these two calibration runs was not due to temperature. A third round of calibration (STAR 3) was conducted to further address the temperature dependence of the total HFGs, and the resulting sensitivities matched closely to STAR 2 (within 2%). Temperature-compensated calibration curves were once again fit to the data. In this case, when the temperature-compensated fits from STAR 3 were applied to STAR 2 data, the residuals between the fits and STAR 2 data were much lower than the residuals due to the linear fits. This suggests that the changes seen between STAR 1 and STAR 2 were likely due to actual changes in the sensors caused by the environmental testing between the two calibrations. A modification of the original calibration process, in which the UUT was exposed to each heat flux for just 3 seconds (instead of 10) to reduce the temperature increase during the test, was additionally performed on several of the HFGs. In general, the sensitivities were 1-1.5% lower than from the 10-second tests, but the temperatures were also significantly lower. When the temperature-compensated fits from the 10-second tests were applied to the 3-second test data, the residuals were greatly improved than when just using the linear fits, further suggesting that the temperature-compensated fits may lead to better accuracy than the linear fits in flight. Convective Calibration The second portion of this study was to create a mapping between the radiative and convective calibration coefficients. The majority of the heating during flight will be convective, so it is important to understand how the HFG response differs under these conditions. However, there are no standardized methods for convective calibration [5]. Because the TPS aerothermal response models were validated at LCAT, the same facility was chosen for convective calibration of two of the total HFGs (Fig. 4). Preliminary results showed that the full-scale output was 3% and 8% higher in convective heat flux as compared to radiative heat flux. However, tunnel variation may have contributed to noise and uncertainty in the measurements, and more testing and analysis remains to be done. Scope of Presentation The presentation will include an overview of the changes seen in HFG calibration before and after environmental testing, differences between radiative and convective calibrations, the modeling work done to aid in understanding the sensor response to varying environments, and recommended future work.

H S Alpert↗

Fitting surfaces to scattered data

A variety of numerical methods for fitting a function to data given at a set of points scattered throughout a domain in the plane are surveyed. Four classes of methods are discussed: (1) global interpolation; (2) local interpolation; (3) global approximation; and (4) local approximation. Also, two-stage methods and contouring are discussed. The surfaces constructed include polynomials, spline functions, and rational functions, among others.

Schumaker, L. L.↗

Temperature and Area Constraints of the South Volund Volcano on IO from the NIMS and SSI instruments during the Galileo G1 Orbit

Analysis of data from darkside and eclipse observations of Io by the NIMS and SSI instruments show that the South Volund hot spot is a manifestation of high temperature active silicate volcanism. The NIMS data are fitted with a two temperature model (developed from modelling terrestrial lavas) which yields a better fit to the data than a single temperature fit.

Eclipes↗

Impact of CMS Multi-jets and Missing Energy Search on CMSSM Fits

Recent CMS data significantly extend the exclusion limits for supersymmetry. We examine the impact of such data on global fits of the constrained minimal supersymmetric standard model (CMSSM) to indirect and cosmological data. By simulating supersymmetric signal events at the LHC, we construct a likelihood map for the recent CMS data, validating it against the exclusion region calculated by the experiment itself. A previous CMSSM global fit is then reweighted by our likelihood map. The CMS results nibble away at the high fit probability density region, transforming probability distributions for the scalar and gluino masses. The CMS search has a nontrivial effect on tan{beta} due to correlations between the parameters implied by the fits to indirect data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The analysis of magnesium oxide hydration in three-phase reaction system

In order to investigate the magnesium oxide hydration process in gas–liquid–solid (three-phase) reaction system, magnesium hydroxide was prepared by magnesium oxide hydration in liquid–solid (two-phase) and three-phase reaction systems. A semi-empirical model and the classical shrinking core model were used to fit the experimental data. The fitting result shows that both models describe well the hydration process of three-phase system, while only the semi-empirical model right for the hydration process of two-phase system. The characterization of the hydration product using X-Ray diffraction (XRD) and scanning electron microscope (SEM) was performed. The XRD and SEM show hydration process in the two-phase system follows common dissolution/precipitation mechanism. While in the three-phase system, the hydration process undergo MgO dissolution, Mg(OH){sub 2} precipitation, Mg(OH){sub 2} peeling off from MgO particle and leaving behind fresh MgO surface. - Graphical abstract: There was existence of a peeling-off process in the gas–liquid–solid (three-phase) MgO hydration system. - Highlights: • Magnesium oxide hydration in gas–liquid–solid system was investigated. • The experimental data in three-phase system could be fitted well by two models. • The morphology analysis suggested that there was existence of a peel-off process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗