Search NASA⌕ Search

SEARCH · Search NASA

Results for “Depth sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Data Release Report for Source Physics Experiment 4Prime (SPE-4Prime) Nevada National Security Site

The fourth test in the Source Physics Experiment series (SPE-4Prime) was conducted at a granite site in Nevada on May 21, 2015, at 18:35:44.000,003,989 ± 20 nanoseconds Coordinated Universal Time. The explosive source was 69.1 kilograms (kg) (including detonator assembly) of Composition C4 plastic explosive (89.14 kg TNT equivalent) detonated at a depth of 87.2 meters (m). The explosion was recorded by an extensive set of instrumentation that includes sensors both at near-field (less than 100 m) and far-field (100 m or greater) distances. The near-field instruments consisted of three-component accelerometers installed at various depths from 7 to 99 m in boreholes positioned around the source hole, and a set of single-component vertical accelerometers on the surface. The far-field network was composed of a variety of seismic and acoustic sensors, including short-period geophones, broadband seismometers, and three-component accelerometers at distances of 100 m to 25 kilometers. Infrasound data were collected from ground-based sensor arrays at distances out to 5 kilometers.

58 GEOSCIENCES↗

Charactarization of Thermal Protection Systems

In 2012, NASA's mission of landing the Mars Science Laboratory (MSL) on Mars was successful. MSL was protected by an ablative heatshield of tiled low density material known as PICA (phenolic impregnated carbon ablator). The heatshield was instrumented with MEDLI (MSL Entry Descent Landing Instrument) a suite of sensors & thermocouples at discrete locations in order to monitor the in-depth ablator temperature response and surface pressure. MEDLI was designed and developed by NASA Langley, in partnership with NASA Ames Research Center for the purposes of probing Mars and evaluating the performance of the spacecraft upon entry into the Martian atmosphere. The flight data reduces the uncertainty in engineer models for predicting the response of a spacecraft towards the extreme heating environment of an entry into the Martian atmosphere. MEDLI2 is a part of the Mars 2020 mission and is the next-generation sensor suite for entry, descent, and landing. This data will again help engineers validate their flight models. Additionally, the atmospheric data, can help us understand atmospheric density and winds. This is a critical study for reducing risks to both robotic and future human missions to Mars. Engineered models for Mars 2020 are dependent upon parameters related to the materials response to heating and radiation. In this work, the thermal properties and other measurements of various ablative materials are analyzed to achieve greater utility of the 2012 MEDLI flight data and more accurately determine the parameters being used in Mars 2020. The purpose of this study was to measure specific heat, thermal conductivity, char yield, reflectance as a function of wavelength, and other thermal parameters and optical properties of various ablative materials. CO2(g) at extreme temperatures emits radiation impacting MEDLI2 flight predictions. Emissivity & absorptivity as a function of temperature were calculated from FTIR and UV-Vis data as a means of investigating whether these materials might absorb CO2 radiation upon entry into the Mars atmosphere.

HEEET↗

Aerosol optical depth increase in partly cloudy conditions

Remote sensing observations of aerosol from surface and satellite instruments are extensively used for atmospheric and climate research. From passive sensors, the apparent cloud-free atmosphere in the vicinity of clouds often appears to be brighter then further away from the clouds, leading to an enhancement in the retrieved aerosol optical depth. Mechanisms contributing to this enhancement, including contamination by undetected clouds, hygroscopic growth of aerosol particles, and meteorological conditions, have been debated in recent literature, but an extent to which each of these factors influence the observed enhancement is poorly known. Here we used 11 years of daily global observations at 10x10 km2 resolution from the MODIS on the NASA Terra satellite to quantify as a function of cloud fraction (CF). Our analysis reveals that, averaged over the globe, the clear sky is enhanced by ? = 0.05 which corresponds to relative enhancements of 25% in cloudy conditions (CF=0.8-0.9) compared with relatively clear conditions (CF=0.1-0.2). Unlike the absolute enhancement ?, the relative increase in ? is rather consistent in all seasons and is 25-35% in the subtropics and 15-25% at mid and higher latitudes. Using a simple Gaussian probability density function model to connect cloud cover and the distribution of relative humidity, we argue that much of the enhancement is consistent with aerosol hygroscopic growth in the humid environment surrounding clouds. Consideration of these cloud-dependent effects will facilitate understanding aerosol-cloud interactions and reduce the uncertainty in estimates of aerosol radiative forcing by global climate models.

54 ENVIRONMENTAL SCIENCES↗

Calibration, measurement, and characterization of soil moisture dynamics in a central Amazonian tropical forest

Soil moisture plays a key role in hydrological, biogeochemical, and energy budgets of terrestrial ecosystems. Accurate soil moisture measurements in remote ecosystems such as the Amazon are difficult and limited because of logistical constraints. Time domain reflectometry (TDR) sensors are widely used to monitor soil moisture and require calibration to convert the TDR's dielectric permittivity measurement (K a ) to volumetric water content (θ v ). In this study, our objectives were to develop a field-based calibration of TDR sensors in an old-growth upland forest in the central Amazon, to evaluate the performance of the calibration, and then to apply the calibration to determine the dynamics of soil moisture content within a 14.2 -m-deep vertical soil profile. Depth-specific TDR calibration using local soils in a controlled laboratory setting yielded a novel K a –θ v third-degree polynomial calibration. The sensors were later installed to their specific calibration depth in a 14.2-m pit. The widely used K a –θ v relationship (Topp model) underestimated the site-specific θ v by 22–42%, indicating significant error in the model when applied to these well-structured, clay-rich tropical forest soils. The calibrated wet- and dry-season θ v data showed a variety of depth and temporal variations highlighting the importance of soil textural differentiation, root uptake depths, as well as event to seasonal precipitation effects. Data such as these are greatly needed for improving our understanding of ecohydrological processes within tropical forests and for improving models of these systems in the face of changing environmental conditions.

54 ENVIRONMENTAL SCIENCES↗

Optimizing the formation of depth-confined nitrogen vacancy center spin ensembles in diamond for quantum sensing

Spin ensembles of nitrogen vacancy (NV) centers in diamond are emerging as powerful spin-based sensors for magnetic, electric and thermal field imaging with high spatial and temporal resolution. In this work, we characterize the formation of depth-confined NV center ensembles, activated by electron irradiation in diamond layers grown by plasma enhanced chemical vapor deposition with nitrogen co-doping. To do so, we exploit the high magnetic sensitivity of ensembles of NV centers to probe their spin environment as a function of growth and irradiation parameters. We engineer an NV ensemble whose magnetic sensitivity is within a factor of two of the static NV-NV dipolar interaction limit, thus demonstrating a powerful platform for quantum sensing.

36 MATERIALS SCIENCE↗

Concept of Operations for Nuclear Warhead Embedded Sensors

Embedded arms-control-sensors provide a powerful new paradigm for managing compliance with future nuclear weapons treaties, where deployed warhead numbers will be reduced to 1000 or less. The CONOPS (Concept of Operations) for use with these sensors is a practical tool with which one may help define design parameters, including size, power, resolution, communications, and physical structure. How frequently must data be acquired and must a human be present? Will such data be acquired for only stored weapons or will it be required of deployed weapons as well? Will tactical weapons be subject to such monitoring or will only strategic weapons apply? Which data will be most crucial? Will OSI's be a component of embedded sensor data management or will these sensors stand alone in their data extraction processes? The problem space is massive, but can be constrained by extrapolating to a reasonable future treaty regime and examining the bounded options this scenario poses. Arms control verification sensors, embedded within the warhead case or aeroshell, must provide sufficient but not excessively detailed data, confirming that the item is a nuclear warhead and that it is a particular warhead without revealing sensitive information. Geolocation will be provided by an intermediate transceiver used to acquire the data and to forward the data to a central processing location. Past Chain-of-Custody projects have included such devices and will be primarily responsible for adding such indicators in the future. For the purposes of a treaty regime a TLI will be verified as a nuclear warhead by knowledge of (a) the presence and mass of SNM, (b) the presence of HE, and (c) the reporting of a unique tag ID. All of these parameters can be obtained via neutron correlation measurements, Raman spectroscopy, and fiber optic grating fabrication, respectively. Data from these sensors will be pushed out monthly and acquired nearly daily, providing one of several verification layers in depth, including on-site inspections, NTM, declarations, and semi-annual BCC meetings. Human intervention will not be necessary. The sheer numbers, small size, and wide distribution of warhead TLIs will mandate the added level of remote monitoring that Embedded Sensors can provide. This multilayer protection will limit the need to increase the frequency of OSIs, by adding confidence that declared TLIs remain as declared and that no undeclared items enter the regime without the other States Party's knowledge. Acceptance of Embedded arms control Sensor technologies will require joint development by all State's Parties involved. Principles of operation and robustness of technologies must be individually evaluated to sustain confidence in the strength of this system against attack. Weapons designers must be assured that these sensors will in no way impact weapon performance and operation, will not affect weapons security and safety, and will have a neutral impact upon weapon system surety. Each State's Party will need to conduct an in depth review of their weapons lifecycle to determine where moves may be reduced to minimize vulnerabilities and where random selection may be used to minimize the ability to make undeclared changes. In the end Verification is a political measure, not a technical one. If the potential users can gain sufficient confidence in the application of Embedded arms control Sensors, they could constitute the final layer of glue to hold together the next Nuclear Arms Control agreement.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Development of Meandering Winding Magnetometer (MWM (Register Trademark)) Eddy Current Sensors for the Health Monitoring, Modeling and Damage Detection of High Temperature Composite Materials

The increased use of high-temperature composite materials in modern and next generation aircraft and spacecraft have led to the need for improved nondestructive evaluation and health monitoring techniques. Such technologies are desirable to improve quality control, damage detection, stress evaluation and temperature measurement capabilities. Novel eddy current sensors and sensor arrays, such as Meandering Winding Magnetometers (MWMs) have provided alternate or complimentary techniques to ultrasound and thermography for both nondestructive evaluation (NDE) and structural health monitoring (SHM). This includes imaging of composite material quality, damage detection and .the monitoring of fiber temperatures and multidirectional stresses. Historically, implementation of MWM technology for the inspection of the Space Shuttle Orbiter Reinforced Carbon-Carbon Composite (RCC) leading edge panels was developed by JENTEK Sensors and was subsequently transitioned by NASA as an operational pre and post flight in-situ inspection at the Kennedy Space Center. A manual scanner, which conformed'automatically to the curvature of the RCC panels was developed and used as a secondary technique if a defect was found during an infrared thermography screening, During a recent proof of concept study on composite overwrapped pressure vessels (COPV's), three different MWM sensors were tested at three orientations to demonstrate the ability of the technology to measure stresses at various fiber orientations and depths. These results showed excellent correlation with actual surface strain gage measurements. Recent advancements of this technology have been made applying MWM sensor technology for scanning COPVs for mechanical damage. This presentation will outline the recent advance~ in the MWM.technology and the development of MWM techniques for NDE and SHM of carbon wra~ped composite overwrapped pressure vessels (COPVs) including the measurement of internal stresses via a surface mounted sensor array. In addition, this paper will outline recent efforts to produce sensors capable of making real-time measurements at temperatures up to 850 C, and discuss previous results demonstrating capability to monitor carbon fiber temperature changes within a composite material.

Russell, Richard↗

The Cloud Detection and UV Monitoring Experiment (CLUE)

We propose a large-area, low-power instrument to perform CLoud detection and Ultraviolet monitoring, CLUE. CLUE will combine the W detection capabilities of the NIGHTGLOW payload, with an array of infrared sensors to perform cloud slicing measurements. Missions such as EUSO and OWL which seek to measure UHE cosmic-rays at 1W20 eV use the atmosphere as a fluorescence detector. CLUE will provide several important correlated measurements for these missions, including: monitoring the atmospheric W emissions &om 330 - 400 nm, determining the ambient cloud cover during those W measurements (with active LIDAR), measuring the optical depth of the clouds (with an array of narrow band-pass IR sensors), and correlating LIDAR and IR cloud cover measurements. This talk will describe the instrument as we envision it.

Barbier, L.↗

Application of remote sensing techniques to hydrography with emphasis on bathymetry

Remote sensing techniques are utilized for the determination of hydrographic characteristics, with emphasis in bathymetry. Two sensor systems were utilized: the Metric Camera Wild RC-10 and the Multispectral Scanner of LANDSAT Satellite (MSS-LANDSAT). From photographs of the metric camera, data of photographic density of points with known depth are obtained. A correlation between the variables density x depth is calculated through a regression straight line. From this line, the depth of points with known photographic density is determined. The LANDSAT MSS images are interpreted automatically in the Iterative Multispectral Analysis System (I-100) with the obtention of point subareas with the same gray level. With some simplifications done, it is assumed that the depth of a point is directly related with its gray level. Subareas with points of the same depth are then determined and isobathymetric curves are drawn. The coast line is obtained through the sensor systems already mentioned. Advantages and limitations of the techniques and of the sensor systems utilized are discussed and the results are compared with ground truth.

Dejesusparada, N.↗

Acoustic Environment of Admiralty Inlet: Broadband Noise Measurements

Admiralty Inlet has been selected as a potential tidal energy site. It is located near shipping lanes, is a highly variable acoustic environment, and is frequented by the highly endangered southern resident killer whale (SRKW). Resolving environmental impacts is the first step to receiving approval to deploy tidal turbines at Admiralty Inlet. Of particular concern is the potential for blade strike or other negative interactions between the SRKW and the tidal turbine. A variety of technologies including passive and active monitoring systems are being considered as potential tools to determine the presence of SRKW in the vicinity of the turbines. Broadband noise level measurements are critical for the determination of design and operation specifications of all marine and hydrokinetic energy capture technologies. Acoustic environment data at the proposed site was acquired at different depths using a cabled vertical line array (VLA) with four calibrated hydrophones. The sound pressure level (SPL) power spectrum density was estimated based on the fast Fourier transform. This study describes the first broadband SPL measurements for this site at different depths with frequency ranging from 10 kHz to 480 kHz in combination with other information. To understand the SPL caused by this bedload transport, three different pressure sensors with temperature and conductivity were also assembled on the VLA to measure the conditions at the hydrophone deployment depth. The broadband SPL levels at frequency ranges of 3 kHz to 7 kHz as a function of depth were estimated. Only the hydrophone at an average depth of 40 m showed the strong dependence of SPL with distance from the bottom, which was possibly caused by the cobbles shifting on the seabed. Automatic Identification System data were also studied to understand the SPL measurements.

16 TIDAL AND WAVE POWER↗

Charge collection characterisation with the Transient Current Technique of the ams H35DEMO CMOS detector after proton irradiation

This paper reports on the characterisation with Transient Current Technique measurements of the charge collection and depletion depth of a radiation-hard high-voltage CMOS pixel sensor produced at ams AG. Several substrate resistivities were tested before and after proton irradiation with two different sources: the 24 GeV Proton Synchrotron at CERN and the 16.7 MeV Cyclotron at Bern Inselspital.

47 OTHER INSTRUMENTATION↗

Optimizing the design and analysis of cryogenic semiconductor dark matter detectors for maximum sensitivity

In this thesis, we illustrate how the complex E- field geometry produced by interdigitated electrodes at alternating voltage biases naturally encodes 3D fiducial volume information into the charge and phonon signals and thus is a natural geometry for our next generation dark matter detectors. Secondly, we will study in depth the physics of import to our devices including transition edge sensor dynamics, quasi- particle dynamics in our Al collection fins, and phonon physics in the crystal itself so that we can both understand the performance of our previous CDMS II device as well as optimize the design of our future devices. Of interest to the broader physics community is the derivation of the ideal athermal phonon detector resolution and it's T 3 c scaling behavior which suggests that the athermal phonon detector technology developed by CDMS could also be used to discover coherent neutrino scattering and search for non-standard neutrino interaction and sterile neutrinos. These proposed resolution optimized devices can also be used in searches for exotic MeV-GeV dark matter as well as novel background free searches for 8GeV light WIMPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A design study for an advanced ocean color scanner system

Along with a colorimetric data analysis scheme, the instrumental parameters which need to be optimized in future spaceborne ocean color scanner systems are outlined. With regard to assessing atmospheric effects from ocean colorimetry, attention is given to computing size parameters of the aerosols in the atmosphere, total optical depth measurement, and the aerosol optical thickness. It is suggested that sensors based on the use of linear array technology will meet hardware objectives.

Kim, H. H.↗

Dante's Volcano

This video contains two segments: one a 0:01:50 spot and the other a 0:08:21 feature. Dante 2, an eight-legged walking machine, is shown during field trials as it explores the inner depths of an active volcano at Mount Spurr, Alaska. A NASA sponsored team at Carnegie Mellon University built Dante to withstand earth's harshest conditions, to deliver a science payload to the interior of a volcano, and to report on its journey to the floor of a volcano. Remotely controlled from 80-miles away, the robot explored the inner depths of the volcano and information from onboard video cameras and sensors was relayed via satellite to scientists in Anchorage. There, using a computer generated image, controllers tracked the robot's movement. Ultimately the robot team hopes to apply the technology to future planetary missions.

Source record↗

Damage Detection Sensor System for Aerospace and Multiple Applications

NASA has identified structural health monitoring and damage detection and verification as critical needs in multiple technology roadmaps. The sensor systems can be customized for detecting location, damage size, and depth, with velocity options and can be designed for particular environments for monitoring of impact or physical damage to a structure. The damage detection system has been successfully demonstrated in a harsh environment and remote integration tested over 1000 miles apart. Multiple applications includes: Spacecraft and Aircraft; Inflatable, Deployable and Expandable Structures; Space Debris Monitoring; Space Habitats; Military Shelters; Solar Arrays, Smart Garments and Wearables, Extravehicular activity (EVA) suits; Critical Hardware Enclosures; Embedded Composite Structures; and Flexible Hybrid Printed Electronics and Systems. For better implementation and infusion into more flexible architectures, important and improved designs in advancing embedded software and GUI interface, and increasing flexibility, modularity, and configurable capabilities of the system are currently being carried out.

Williams, Martha↗

Exploration Extravehicular Mobility Unit (xEMU) Chamber B Thermal Vacuum “Suit 2” Pressure Garment System Hardware and Test Design

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation space suit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test hardware design and test methodology for the “Suit 2” Pressure Garment System (PGS) test article. The uncrewed “Suit 2” PGS test article consisted of a full PGS assembly with simulated Portable Life Support System (PLSS) functionality provided by test equipment, including a ventilation loop and two distinct thermal control loops. This paper will discuss in depth the test hardware design, including internal suit thermal boundary simulation, sensor quantity and placement, test support equipment rigs for gas flow, water flow, and power. Custom hardware designed to add additional penetrations to the suit or provide additional interfaces for sensors will also be discussed. This paper will also address the assembly and integration sequence for the test article. In addition to test hardware design, this paper will provide insights into the test methodology for this test article, including a discussion of thermal steady-state testing, simultaneous dual suit thermal vacuum testing, and hazard mitigation and controls.

xEMU↗

The Effects of Heterogeneities on Seismic Wave Propagation in the Climax Stock

The Comprehensive Nuclear Test-Ban Treaty requires the ability to detect low-yield (less than 150kton) nuclear events. This kind of monitoring can only be done seismically on a regional scale (within 2000km). At this level, it is difficult to distinguish between low-yield nuclear events and non-nuclear events of similar magnitude. In order to confidently identify a nuclear event, a more detailed understanding of nuclear seismic sources is needed. In particular, it is important to know the effects of local geology on the seismic signal. This study focuses on P-wave velocity in heterogeneous granitoid. The Source Physics Experiment (SPE) is currently performing low-yield tests with chemical explosives at the Nevada National Security Site (NNSS). The exact test site was chosen to be in the Climax Stock, a cretaceous granodiorite and quartz-monzonite pluton located in Area 15 of the NNSS. It has been used in the past for the Hard Hat and Pile Driver nuclear tests, which provided legacy data that can be used to simulate wave propagation. The Climax Stock was originally chosen as the site of the SPE partly because of its assumed homogeneity. It has since been discovered that the area of the stock where the SPE tests are being performed contains a perched water table. In addition, the stock is known to contain an extensive network of faults, joints, and fractures, but the exact effect of these structural features on seismic wave velocity is not fully understood. The SPE tests are designed to seismically capture the explosion phenomena from the near- to the far-field transition of the seismic waveform. In the first SPE experiment, 100kg of chemical explosives were set off at a depth of 55m. The blast was recorded with an array of sensors and diagnostics, including accelerometers, geophones, rotational sensors, short-period and broadband seismic sensors, Continuous Reflectometry for Radius vs. Time Experiment, Time of Arrival, Velocity of Detonation, and infrasound sensors. The focus of this study is two-fold: (1) the geophone array that was focused over the SPE shot and (2) a high-resolution seismic profile that was recently acquired at the field site. The geophone array was placed radially around the SPE shot in five directions with 100m spacing and out to a distance of 2 km. The high-resolution profile was about 475m in length with station and shot spacing of 5m using a 7000lb mini-vibe as a source. In both data sets, the first arrivals will be used to develop velocity models. For the geophone array, 1-D P-wave velocity models will be developed to determine an average apparent velocity of the Climax Stock. The high-resolution data will be used to develop a 2-D P-wave velocity model along the seismic profile. This is in an effort to elucidate the water table in more detail and provide additional information on the near-surface structure. These results will be used in the overall modeling effort to fully characterize the test bed and develop a physics-based model to simulate seismic energy from the SPE events.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Inter-digital capacitive sensor for evaluating cable jacket and insulation aging

An inter-digital capacitive (TDC) sensor has previously been used to measure dielectric properties of cable insulation polymer material when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket. The dielectric properties of many cable jacket and insulation polymers are known to change due to thermal and radiation exposure-related damage. These dielectric properties frequently track with other measures of cable aging, such as tensile elongation-at-break and indenter modulus that have been broadly established as cable insulation polymer assessment methods. The external jacket of a cable is likely to have a different permittivity from the underlying insulation, and frequently the jacket material exhibits more severe damage than the insulation material due to environmental exposure. Because the jacket serves primarily to guard the cable during installation, as long as the underlying insulation condition is acceptable, the jacket condition is relatively unimportant in service. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, a set of tools has been developed including (1) a parallel-plate sensor to directly measure the permittivity spectrum of flat sheet material and (2) an TDC and fixture to measure the effect of cable polymer dielectric property change on the sensor response. The TDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. The electrodes are printed on one side of a flexible substrate that can be conformed to the surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad-frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. By finite element modeling (FEM) and experimentation, this study investigates the effect of tine spacing and other design parameters associated with the TDC on the voltage (potential) distribution and electric field depth of penetration. The TDC measurement of an unshielded ethylene-propylene rubber (EPR)-insulated cable is shown to track with the degree of aging and quantities obtained by established methods. For jacketed cable systems, the TDC response is dominated by the jacket but, by analyzing measurements from TDC sensors with different depths-of-field penetration into the cable under test, the influence of the chlorinated polyethylene (CPE) cable jacket material degradation can be separated from an assessment of the cable insulation thereby enabling assessment of the insulation beneath/through the jacket.

Cable NDE, Interdigital Capacitance, Cable test↗