Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRO-OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Vision Test in Seconds

Acuity Systems, Inc. developed an electro-optical instrument under a grant from NASA to measure the visual performance of pilots. Transferred from Ames Research Center, this instrument now allows you to have your eyes tested in seconds by relatively unskilled operators. The device automatically measures refractive error of eye and prints out proper prescription for glasses. The unit also detects cataracts and glaucoma.

Source record↗

Lead Poison Detection

With NASA contracts, Whittaker Corporations Space Science division has developed an electro-optical instrument to mass screen for lead poisoning. Device is portable and detects protoporphyrin in whole blood. Free corpuscular porphyrins occur as an early effect of lead ingestion. Also detects lead in urine used to confirm blood tests. Test is inexpensive and can be applied by relatively unskilled personnel. Similar Whittaker fluorometry device called "drug screen" can measure morphine and quinine in urine much faster and cheaper than other methods.

Source record↗

Microbe Detector

The AutoMicrobic System (AMS) represents years of intensive research and development by McDonnell Douglas Corp. that originated with a NASA study aimed at development of a fully automated microbial detection and identification system for spacecraft use. A urine specimen is placed into the system, where it is subjected to different freeze-dried microbe nutrients for the nine most common pathogens. An electro-optical scanner studies each specimen once an hour through a 4-to-13 hour cycle, operating automatically. Changes in cell growths on each culture are monitored by computer. The presence of pathogens is indicated when growth reaches a predetermined level. The system also enumerates the pathogens and specifies the type. Developed initially to handle urine testing, AMS soon is expected to allow analyses of blood, spinal fluid, and other body fluids. An additional capability under development is "susceptibility testing," or the determination of which microbe-killing agents-such as penicillin or other antibiotics-would be most effective in eliminating the pathogens. The whole process of detecting, identifying, and enumerating the pathogens and determining susceptibility is accomplished in less half the time required for the manual procedure. The AMS minimizes human error, reduces technician time , and increases laboratory output.

Source record↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatilizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vilicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Kuppermann, Aron↗

Frequency doubled, cavity dumped feedback laser

Higher efficiency in cavity dumping and frequency doubling in a laser used to produce modulated output beam pulses is achieved by deflecting light out of the resonant cavity to a third mirror through a frequency doubler using an electro-optic modulator and a polarizing beamsplitter in the resonant cavity, or using just an acousto-optic modulator to deflect light out of the laser cavity in response to a control signal (electric or acoustic). The frequency doubler in front of the third mirror rotates the frequency doubled light so that it will pass out of the laser cavity through the polarizing beamsplitter, while undoubled frequency light is reflected by the polarizing beamsplitter back into the gain medium of the laser. In the case of using a type-II frequency doubler, a dichroic beamsplitter deflects out the frequency doubled light and passes the undoubled frequency light to the polarizing beamsplitter for return to the laser gain medium. If an acousto-optic modulator is used, it deflects light out of the primary laser cavity, so a polarizing beamsplitter is not needed, and only a dichroic beamsplitter is needed to separate frequency doubled light out of the path from the third mirror.

Sipes, Jr., Donald L.↗

Method of making a semiconductor device assembly

The invention is a semiconductor device assembly and method of making the same. A mounting plate has positioning means for positioning the plate relative to a header, a first mounting surface of the plate is attached to the header and a semiconductor device is attached to a second mounting surface of the mounting plate. The assembly is made by forming the mounting plate, positioning the mounting plate relative to the header by the positioning means, attaching the first mounting surface to the header and the semiconductor device to the second mounting surface. Another method of making the assembly is by defining and etching a mounting plate and attaching the first mounting surface to the header and the semiconductor device to the second mounting surface. This assembly and process provides an efficient means for mounting semiconductor devices and in particular electro-optic devices such as lasers.

Dholakia, Anil R.↗

Automated mass spectrometer analysis system

An automated mass spectrometer analysis system is disclosed, in which samples are automatically processed in a sample processor and converted into volatilizable samples, or their characteristic volatilizable derivatives. Each volatizable sample is sequentially volatilized and analyzed in a double focusing mass spectrometer, whose output is in the form of separate ion beams all of which are simultaneously focused in a focal plane. Each ion beam is indicative of a different sample component or different fragments of one or more sample components and the beam intensity is related to the relative abundance of the sample component. The system includes an electro-optical ion detector which automatically and simultaneously converts the ion beams, first into electron beams which in turn produce a related image which is transferred to the target of a vidicon unit. The latter converts the images into electrical signals which are supplied to a data processor, whose output is a list of the components of the analyzed sample and their abundances. The system is under the control of a master control unit, which in addition to monitoring and controlling various power sources, controls the automatic operation of the system under expected and some unexpected conditions and further protects various critical parts of the system from damage due to particularly abnormal conditions.

Boettger, Heinz G.↗

Semiconductor device assembly and method of making same

The invention is a semiconductor device assembly and method of making the same. A mounting plate has positioning means for positioning the plate relative to a header, a first mounting surface of the plate is attached to the header and a semiconductor device is attached to a second mounting surface of the mounting plate. The assembly is made by forming the mounting plate, positioning the mounting plate relative to the header by the positioning means, attaching the first mounting surface to the header and the semiconductor device to the second mounting surface. Another method of making the assembly is by defining and etching a mounting plate and attaching the first mounting surface to the header and the semiconductor device to the second mounting surface. This assembly and process provides an efficient means for mounting semiconductor devices and in particular electro-optic devices such as lasers.

Dholakia, Anil R.↗

A Method of Monitoring Non-Resonant Raman Lidar Returns During Daylight Hours

A method for using non-resonant Raman lidar during daytime hours is presented. A dual (or quadruple) arrangement of electro-optical channels is set up in the lidar receiver. Each channel contains its own optical spectral response as determined by an appropriate set of interference filters. The incoming signal is split and fed into two channels, filtered (simultaneously) and then inserted into the input terminals of an operational amplifier. The difference signal is selected and amplified whereas the common portion of the signal is highly attenuated (Common Mode Re.jection Ratio = 75-80db). For the present hardware, daylight intensities 10(exp 2)-10(exp 3) times Raman signals are received simultaneously. Mean values of intensities of daylight signals which give rise to a constant differences merely shift the value of the measured variable at the ground. These mean value signals have their common part highly attenuated. The differences of the fluctuation portions of the daylight signal represents a noise signal. Identical (space-time) optical paths for each component of the daylight signal produce the same fluctuational spectra in each channel. Hence noise levels, much less than signal levels, are anticipated. First a N2-H2 ) signal pair is differenced. Then an N2-O2 pair is differenced and used for instrumental normalization purposes. Signal levels to be encountered are quite well known as a result of prior field work. Improved optical design of laser system can reduce mean value of daylight intensities by 10(exp 2). Thus the mean daylight intensity can be set equal to the expected signal levels by more advanced optical design. Performance characteristics of photomultiplier pairs are discussed in this connection.

Cooney, John↗

Novel, Middle and Long Wave Infrared Laser Sources For Accelerator Applications

The main accomplishment during Years 2020-2024 of the DOE Accelerator Stewardship Program is proof-of-principle demonstration of amplification of an ultrashort 10 µm seed pulse in a multiatmosphere CO 2 laser optically pumped by nanosecond pulses of either a ~4.3 µm Fe:ZnSe laser or a 2.8 µm electro-optically (EO) Q-switched Er: Laser. This has been accomplished at the UCLA Neptune Laboratory by using about 100 mJ, ~100 ns long pulses generated by the pump laser built for this purpose by the UAB team. Implementation of EO Q-switching regime in the solid-state Er:laser system made possible nanosecond synchronization between the pump pulse and the 0.5 ps seed pulse produced by a commercial Ti:sapphire laser based mid-IR OPA/DFG. The injection mode-locking regime realized in a compact Mult atmosphere 3 Hz CO 2 -He regenerative amplifier enabled generation of a train of ultrashort pulses separated by the cavity round-trip time of ~3.2 ns. The measured gain lifetime of ~1 µs at a total pressure of ~12-15 atm indicates that lifetime of the upper laser level is a critical limiting factor in designing high-pressure CO 2 amplifiers. A single picosecond 10 mm pulse with an energy 0.1-0.2 mJ was extracted from the amplifier’s cavity using an ultrafast Ge semiconductor switch whose reflectivity was photo-induced by a femtosecond 800 nm pulse. For direct amplification regime, nonlinear absorption in Ge at 10 mm at GW/cm 2 intensities limited the extracted energy. Therefore, the generated energy could be further increased by minimizing losses in the switch and optimizing the cavity mode size. Based on the obtained data in collaboration with BNL colleagues, we have designed a high-pressure CO 2 amplifier to be used as a preamplifier for the future experiments at the ATF BNL. The latter work is the subject of funding availability.

60 APPLIED LIFE SCIENCES↗

Resonance Ionization Spectroscopy Experiment at Facility for Rare Isotope Beams

This manuscript reports on the commissioning of the Resonance Ionization Spectroscopy Experiment (RISE) at the BEam COoler and LAser spectroscopy (BECOLA) facility at Facility for Rare Isotope Beams (FRIB). The instrument implements the collinear resonance ionization spectroscopy technique for sensitive measurements of isotope shifts and hyperfine structure of short-lived isotopes produced at FRIB. The existing BECOLA beamline was extended to integrate an electrostatic ion-beam bender and an ion detector at ultrahigh vacuum. An injection-seeded titanium-sapphire laser and a multiharmonic pulsed neodymium-doped yttrium aluminum garnet laser were installed to perform resonant excitation and selective ionization. Commissioning tests were performed to demonstrate the capabilities of the instrument by measuring the hyperfine structure of stable 27 Al produced in an offline ion source. The RISE instrument is ready and operational for future studies of short-lived isotopes at FRIB.

Atomic spectra↗

Erbium quantum memory platform with long optical coherence via back-end-of-line deposition on foundry-fabricated photonics

Realizing scalable quantum interconnects necessitates the integration of solid-state quantum memories with foundry photonics processes. While prior photonic integration efforts have relied upon specialized, laboratory-scale fabrication techniques, this work demonstrates the monolithic integration of a quantum memory platform with low-loss foundry photonic circuits via back-end-of-line deposition. We deposited thin films of titanium dioxide (Ti⁢O 2 ) doped with erbium (Er) onto silicon nitride nanophotonic waveguides and studied Er optical coherence at subkelvin temperatures with photon echo techniques. Furthermore, we suppressed optical dephasing through ex-situ oxygen annealing and optimized measurement conditions, which yielded an optical coherence time of 64 μ⁢s (a 5-kHz homogeneous linewidth) and slow spectral diffusion of 27 kHz over 4 ms, results that are comparable to state-of-the-art Er nanophotonic devices. Combined with second-long electron spin lifetimes and demonstrated electrical control of Er emission, our findings establish Er:Ti⁢O 2 on foundry photonics as a manufacturable platform for ensemble and single-ion quantum memories.

Electro-optic effects↗

On-chip frequency-bin quantum photonics

Abstract Frequency-bin encoding furnishes a compelling pathway for quantum information processing systems compatible with established lightwave infrastructures based on fiber-optic transmission and wavelength-division multiplexing. Yet although significant progress has been realized in proof-of-principle tabletop demonstrations, ranging from arbitrary single-qubit gates to controllable multiphoton interference, challenges in scaling frequency-bin processors to larger systems remain. In this Perspective, we highlight recent advances at the intersection of frequency-bin encoding and integrated photonics that are fundamentally transforming the outlook for scalable frequency-based quantum information. Focusing specifically on results on sources, state manipulation, and hyperentanglement, we envision a possible future in which on-chip frequency-bin circuits fulfill critical roles in quantum information processing, particularly in communications and networking.

electro-optic modulators↗

Space applications.

Laser in space application, discussing electro- optical devices

ELECTRO-OPTICS↗