SEARCH · Search NASA
Results for “ELECTROMAGNETIC INSTRUMENT”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Brilliant high harmonic sources with extended cut-off
The most challenging application of time resolved spectroscopy is to directly watch the structural and electronic dynamics. Here we present several ways for realizing laser driven x-ray sources, offering atomic spatial and temporal resolution. Our approaches are based on high harmonic generation and include quasi-phase matching in two successive gas jets, extending the cut-off by high harmonic generation in an ion channel, and amplification of HHG in a plasma based amplifier.
Hard x-ray nanobeam characterization by coherent diffraction microscopy
We have carried out a ptychographic scanning coherent diffraction imaging experiment on a test object in order to characterize the hard x-ray nanobeam in a scanning x-ray microscope. In addition to a high resolution image of the test object, a detailed quantitative picture of the complex wave field in the nanofocus is obtained with high spatial resolution and dynamic range. Both are the result of high statistics due to the large number of diffraction patterns. The method yields a complete description of the focus, is robust against inaccuracies in sample positioning, and requires no particular shape or prior knowledge of the test object.
Study of precision weak-link stage systems with large travel range and sub-nanometer-scale resolution
To use x-ray optics with nanometer resolution limit, scanning x-ray nanoprobes with corresponding mechanical positioning capability need to be designed. In particular, positioning stages with both sub-nanometer resolution and a positioning/scanning range of several millimeters are required. Based on our design of precision weak-link stages with interferometric encoders for the Center for Nanoscale Materials (CNM) hard x-ray nanoprobe at the Advanced Photon Source (APS) Sector 26, we have developed a new two-dimensional (2-D) weak-link stage system for nanopositioning of a specimen holder. This system provides sub-nanometer resolution, coupled with sub-nanometer metrology at a travel range of several millimeters. The 2-D weak-link stage system is designed with high structure stiffness using laminar overconstrained weak-link mechanisms [4-6]. In this paper we present the study of a linear precision weak-link stage system with sub-centimeter travel range and sub-nanometer positioning resolution. Design of a rotary weak-link stage system with 10-nrad resolution and 10-degree-level travel range is also discussed in this paper.
Two-dimensional Detector for High Resolution Soft X-ray Imaging
A new two-dimensional (2D) detector for detecting soft X-ray (SX) images was developed. The detector has a scintillator plate to convert a SX image into a visible (VI) one, and a relay optics to magnify and detect the converted VI image. In advance of the fabrication of the detector, quantum efficiencies of scintillators were investigated. As a result, a Ce:LYSO single crystal on which Zr thin film was deposited was used as an image conversion plate. The spatial resolution of fabricated detector is 3.0 {mu}m, and the wavelength range which the detector has sensitivity is 30-6 nm region.
Development of X-ray Beam Position Monitors for Superconducting Wiggler
For the development of an X-ray beam position monitor (XBPM) for the superconducting wiggler (SW) at the NSRRC, two XBPM are installed in the SW front end. The blades of the XBPM were manufactured with material of three types; tungsten, Glidcop and aluminium, to test the effect of the material on the performance of the XBPM. These three materials are compared with blades of molybdenum that were previously installed. The vibration and thermal expansion of the pillar of a XBPM affects the position reading of the XBPM. For pillars of XBPM of various designs, each type has a distinct thermal isolating material and is filled with a separate damping material for comparison. The design requirements of these XBPM include high spatial resolution of the monitor and mechanical stability of the structure with a large thermal load. The design, fabrication and measurement results are presented here.
Silicon Absolute X-Ray Detectors
The responsivity of silicon photodiodes having no loss in the entrance window, measured using synchrotron radiation in the 1.75 to 60 keV range, was compared to the responsivity calculated using the silicon thickness measured using near-infrared light. The measured and calculated responsivities agree with an average difference of 1.3%. This enables their use as absolute x-ray detectors.
Lab-based Ultrafast Molecular Structure
The proliferation of various laser-driven approaches to sub-picosecond hard X-ray and short-wavelength radiation generation in the past few decades has opened many avenues for the laboratory-based development of traditionally facility-based short wavelength ultrafast molecular structure science. Together with the introduction of microcalorimeter detection schemes, this opens the floodgates to widespread, decentralized implementation of what were until recently specialist short wavelength techniques. A parallel situation exists for the contemporary adoption of sub-wavelength resolution optical microscopies. In what follows, a few ultrafast molecular structure developments and their rationale are briefly recounted.
Recent results from WASA-at-COSY
WASA--a 4{pi} spectrometer for detection of charged and neutral particles--started operation at the cooler synchrotron COSY-Juelich in 2007. A number of experiments on meson production and decays have been carried out since then. The status of the analysis and preliminary results of some selected topics from the physics program are discussed.
The Study of Electromagnetic Field Response Using Very Low Frequency Methods in Geothermal Area, Sabang
Electromagnetic field measurements have been performed using the method of Very Low Frequency tilt angle pattern in Jaboi, Sabang. A site survey was conducted and carried out to identify the anomalies of location, depth and geometry of hydrothermal based on tilt angle measurement and ellipse. Objective of this study is to see the response of the magnetic and electric field in relation to location, depth and hydrothermal geometry. The devices of T-VLF-R IRIS was used in this study, while the (NWC) station was selected as main station and (JJF4) station was selected as comparison station. The electromagnetic field survey was recorded for a line spanned as long as 900 meters at the interval of 10 meter depth. The results of this study show the greatest anomaly occurred at line interval between 400-600 meters with a depth of 10-140 meters. Anomaly pattern of each depth shows that the propagation pattern of hydrothermal is in the form of vertical pipe flow.
Development of rapid, continuous calibration techniques and implementation as a prototype system for civil engineering materials evaluation
Until recently, civil engineering material calibration data could only be obtained from material sample cores or via time consuming, stationary calibration measurements in a limited number of locations. Calibration data are used to determine material propagation velocities of electromagnetic waves in test materials for use in layer thickness measurements and subsurface imaging. Limitations these calibration methods impose have been a significant impediment to broader use of nondestructive evaluation methods such as ground-penetrating radar (GPR). In 2006, a new rapid, continuous calibration approach was designed using simulation software to address these measurement limitations during a Federal Highway Administration (FHWA) research and development effort. This continuous calibration method combines a digitally-synthesized step-frequency (SF)-GPR array and a data collection protocol sequence for the common midpoint (CMP) method. Modeling and laboratory test results for various data collection protocols and materials are presented in this paper. The continuous-CMP concept was finally implemented for FHWA in a prototype demonstration system called the Advanced Pavement Evaluation (APE) system in 2009. Data from the continuous-CMP protocol is processed using a semblance/coherency analysis to determine material propagation velocities. Continuously calibrated pavement thicknesses measured with the APE system in 2009 are presented. This method is efficient, accurate, and cost-effective.
High-Energy Nanoscale-Resolution X-ray Microscopy Based on Refractive Optics on a Long Beamline
The long length and good coherence properties of ID11 at the ESRF have led to the development of x-ray microscopy based on compound refractive lenses (CRLs). For the highest resolution full-field microscopy, the sample is placed {approx}40 m from the source, which can be micro-focused by a transfocator as a condenser. Due to the long length of the beamline and consequent long sample-detector distance, a CRL objective can be placed up to a meter behind the sample and still allow for magnification of 60x on a detector located at 99 m--enough to achieve easily 100-nm resolution with a typical high-resolution detector.
Gamma-ray astronomy: From Fermi up to the HAWC high-energy {gamma}-ray observatory in Sierra Negra
Gamma-rays represent the most energetic electromagnetic window for the study of the Universe. They are studied both from space at MeV and GeV energies, with instruments like the Fermi{gamma}-ray Space Telescope, and at TeV energies with ground based instruments profiting of particle cascades in the atmosphere and of the Cerenkov radiation of charged particles in the air or in water. The Milagro gamma-ray observatory represented the first instrument to successfully implement the water Cerenkov technique for {gamma}-ray astronomy, opening the ground for the more sensitive HAWC {gamma}-ray observatory, currently under development in the Sierra Negra site and already providing early science results.
Recent development of plasma optical systems (invited)
The article devotes a brief description of the recent development and current status of an ongoing research of plasma optical systems based on the fundamental plasma optical idea magnetic electron isolation, equipotentialization magnetic field lines, and the axi-symmetric cylindrical electrostatic plasma lens (PL) configuration. The experimental, theoretical, and simulation investigations have been carried out over recent years collaboratively between IP NASU (Kiev), LBNL (Berkeley, USA), and HCEI RAS (Tomsk). The crossed electric and magnetic fields inherent the PL configuration that provides the attractive method for establishing a stable plasma discharge at low pressure. Using PL configuration, several high reliability plasma devices were developed. These devices are attractive for many high-tech applications.
On the study of hydrodynamic instabilities in the presence of background magnetic fields in high-energy-density plasmas
Blast-wave-driven hydrodynamic instabilities are studied in the presence of a background B-field through experiments and simulations in the high-energy-density (HED) physics regime. In experiments conducted at the Laboratoire pour l’utilisation des lasers intenses (LULI), a laser-driven shock-tube platform was used to generate a hydrodynamically unstable interface with a prescribed sinusoidal surface perturbation, and short-pulse x-ray radiography was used to characterize the instability growth with and without a 10-T B-field. The LULI experiments were modeled in FLASH using resistive and ideal magnetohydrodynamics (MHD), and comparing the experiments and simulations suggests that the Spitzer model implemented in FLASH is necessary and sufficient for modeling these planar systems. These results suggest insufficient amplification of the seed B-field, due to resistive diffusion, to alter the hydrodynamic behavior. Although the ideal-MHD simulations did not represent the experiments accurately, they suggest that similar HED systems with dynamic plasma-β (=2μ0ρv2/B2) values of less than ∼100 can reduce the growth of blast-wave-driven Rayleigh–Taylor instabilities. These findings validate the resistive-MHD FLASH modeling that is being used to design future experiments for studying B-field effects in HED plasmas.
Asymmetrisation of the profile of a thin dynamic holographic grating in a TV-locked optical feedback loop
A system for recording a dynamic holographic grating in an optically addressed liquid-crystal spatial light modulator is studied. The system provides the asymmetrisation of the grating profile by using a TV-locked optical feedback loop (nonlinear or adaptive interferometer). (laser applications and other topics in quantum electronics)
Radiation phase locking in an array of globally coupled fibre lasers
A model of an array of globally coupled fibre lasers, with the same fraction of the total output beam returned to each laser, is considered. The basic element of the model is a single laser controlled by an external signal. The output power of each laser in the array is found as a function of small-signal gain and frequency detuning. The maximum efficiency of phase locking and minimum fraction of output radiation that is necessary to form a feedback are calculated as functions of the number of lasers in the array. It is shown that gain saturation increases the efficiency of coherent beam summation in arrays containing up to 20 lasers. (control of radiation parameters)
About possibilities of clearing near-Earth space from dangerous debris by a spaceborne laser system with an autonomous cw chemical HF laser
The possibility of clearing hazardous near-Earth space debris using a spaceborne laser station with a large autonomous cw chemical HF laser is substantiated and the requirements to its characteristics (i.e., power and divergence of laser radiation, pulse duration in the repetitively pulsed regime, repetition rate and total time of laser action on space debris, necessary to remove them from the orbits of the protected spacecrafts) are determined. The possibility of launching the proposed spaceborne laser station to the orbit with the help of a 'Proton-M' carrier rocket is considered. (laser applications)