Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Nuclear Excitation and Fission Studies with Short Pulsed Laser-Driven High Energy Gamma Rays

We propose the development of a platform to study photon excitation of high Z nuclei utilizing a high energy (70 J) short pulsed (500 fs) laser to drive > 5 MeV γ-radiation. The laser beam will be focused onto a specially prepared foam or corrugated conveying target, where it generates relativistic MeV electrons via ponderomotive and wake-field acceleration mechanisms. γ-emission is produced in the form of bremsstrahlung in the same target or in a separated high-Z γ-production target hit by the accelerated MeV electrons. The high energy γ-rays will be utilized to provide nuclear state excitation in the short time domain. The γ platform will allow to investigate photo fission of high Z target material positioned in an auxiliary target chamber in the γ-ray beam path via the established gas transport scheme. The photo fission yield will provide furthermore diagnostic information on the produced γ-yield. In addition, γ-spectroscopy will be used to identify γ-lines for the diagnostic of the excited state population of high Z target nuclei. This research capability is relevant to the understanding of how nuclear excitation effects fission, in relevance to recent astrophysical observations on element nucleosynthesis. These processes involve neutron-rich fragments and processes such as fission recycling (e. g. in neutron stars outer crusts).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Positron acceleration in plasma wakefields

Plasma acceleration has emerged as a promising technology for future particle accelerators, particularly linear colliders. Significant progress has been made in recent decades toward high-efficiency and high-quality acceleration of electrons in plasmas. However, this progress does not generalize to the acceleration of positrons, as plasmas are inherently charge asymmetric. Here, we present a comprehensive review of historical and current efforts to accelerate positrons using plasma wakefields. Proposed schemes that aim to increase energy efficiency and beam quality are summarized and quantitatively compared. A dimensionless metric that scales with the luminosity-per-beam power is introduced, indicating that positron-acceleration schemes are currently below the ultimate requirement for colliders. The primary issue is electron motion; the high mobility of plasma electrons compared to plasma ions, which leads to nonuniform accelerating and focusing fields that degrade the beam quality of the positron bunch, particularly for high efficiency acceleration. Finally, we discuss possible mitigation strategies and directions for future research.

43 PARTICLE ACCELERATORS↗

Online multi-objective particle accelerator optimization of the AWAKE electron beam line for simultaneous emittance and orbit control

Multi-objective optimization is important for particle accelerators where various competing objectives must be satisfied routinely such as, for example, transverse emittance vs bunch length. We develop and demonstrate an online multi-time scale multi-objective optimization algorithm that performs real time feedback on particle accelerators. We demonstrate the ability to simultaneously minimize the emittance and maintain a reference trajectory of a beam in the electron beamline in CERN’s Advanced Proton Driven Plasma Wakefield Acceleration Experiment.

43 PARTICLE ACCELERATORS↗

Transverse oscillating bubble enhanced laser-driven betatron X-ray radiation generation

Abstract Ultrafast high-brightness X-ray pulses have proven invaluable for a broad range of research. Such pulses are typically generated via synchrotron emission from relativistic electron bunches using large-scale facilities. Recently, significantly more compact X-ray sources based on laser-wakefield accelerated (LWFA) electron beams have been demonstrated. In particular, laser-driven sources, where the radiation is generated by transverse oscillations of electrons within the plasma accelerator structure (so-called betatron oscillations) can generate highly-brilliant ultrashort X-ray pulses using a comparably simple setup. Here, we experimentally demonstrate a method to markedly enhance the parameters of LWFA-driven betatron X-ray emission in a proof-of-principle experiment. We show a significant increase in the number of generated photons by specifically manipulating the amplitude of the betatron oscillations by using our novel Transverse Oscillating Bubble Enhanced Betatron Radiation scheme. We realize this through an orchestrated evolution of the temporal laser pulse shape and the accelerating plasma structure. This leads to controlled off-axis injection of electrons that perform large-amplitude collective transverse betatron oscillations, resulting in increased radiation emission. Our concept holds the promise for a method to optimize the X-ray parameters for specific applications, such as time-resolved investigations with spatial and temporal atomic resolution or advanced high-resolution imaging modalities, and the generation of X-ray beams with even higher peak and average brightness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of permanent magnet radiation resiliency studies at CEBAF

An ongoing investigation for the future of Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) lies in upgrading its maximum nominal energy using Fixed-Field Alternating-gradient (FFA) technology for its recirculating arcs, using permanent magnets for the FFA arcs. A common concern among the community is the degradation of these permanent magnets during operation due to the radiation environment in which they will be present. This work, funded by a Laboratory Directed R&D grant, aims to measure the permanent magnet degradation in the CEBAF tunnel enclosure, and extrapolate to the energies expected from the upgrade. We present the latest results of this study, as well as plans moving forward.

Accelerator Physics↗

SRF cavity instability detection with machine learning at CEBAF

During the operation of the Continuous Electron Beam Accelerator Facility (CEBAF), one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detectfast transient instabilities during these trip events. These challenges make the identification of an unstable cavity out of the hundreds installed at CEBAF a difficult and time-consuming task. To tackle these issues, a fast data acquisition system (DAQ) for the legacy SRF cavities has been developed, which records the sample at 5 kHz. An unsupervised learning framework has been developed to identify anomalous SRF cavity behavior. We will discuss the present status of the DAQ system and our framework, along with recent successes in detecting anomalous cavity behavior. Overall, our method offers a practical solution for identifying unstable SRF cavities, contributing to increased beam availability and machine reliability.

Accelerator Physics↗

Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗

High Efficiency Uniform Wakefield Acceleration of a Positron Beam Using Stable Asymmetric Mode in a Hollow Channel Plasma

Plasma wakefield acceleration in the blowout regime is particularly promising for high-energy acceleration of electron beams because of its potential to simultaneously provide large acceleration gradients and high energy transfer efficiency while maintaining excellent beam quality. However, no equivalent regime for positron acceleration in plasma wakes has been discovered to date. We show that after a short propagation distance, an asymmetric electron beam drives a stable wakefield in a hollow plasma channel that can be both accelerating and focusing for a positron beam. A high charge positron bunch placed at a suitable distance behind the drive bunch can beam-load or flatten the longitudinal wakefield and enhance the transverse focusing force, leading to high efficiency and narrow energy spread acceleration of the positrons. Three-dimensional quasistatic particle-in-cell simulations show that an over 30% energy extraction efficiency from the wake to the positrons and a 1% level energy spread can be simultaneously obtained. Further optimization is feasible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Explainable physics-based constraints on reinforcement learning for accelerator optimization

We present a reinforcement learning (RL) framework for optimizing particle accelerator experiments that builds explainable physics-based constraints on agent behavior. The goal is to increase transparency and trust by letting users verify that the agent’s decision-making process incorporates suitable physics. Our algorithm uses a learnable surrogate function for physical observables, such as energy, and uses them to fine-tune how actions are chosen. This surrogate can be represented by a neural network or by an interpretable sparse dictionary model. We test our algorithm on a range of particle accelerator optimization environments designed to emulate the Continuous Electron Beam Accelerator Facility at Jefferson Lab. By examining the mathematical form of the learned constraint function, we are able to confirm the agent has learned to use the established physics of each environment. In addition, we find that the introduction of a physics-based surrogate enables our RL algorithms to reliably converge for difficult high-dimensional accelerator optimization environments.

explainability↗

Volt-per-Ångstrom terahertz fields from X-ray free-electron lasers

The electron linear accelerators driving modern X-ray free-electron lasers can emit intense, tunable, quasi-monochromatic terahertz (THz) transients with peak electric fields of V Å -1 and peak magnetic fields in excess of 10 T when a purpose-built, compact, superconducting THz undulator is implemented. New research avenues such as X-ray movies of THz-driven mode-selective chemistry come into reach by making dual use of the ultra-short GeV electron bunches, possible by a rather minor extension of the infrastructure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HIGH VOLTAGE DESIGN AND EVALUATION OF WIEN FILTERS FOR THE CEBAF 200 keV INJECTOR UPGRADE

High-energy nuclear physics experiments at the Jefferson Lab Continuous Electron Beam Accelerator Facility (CEBAF) require highly spin-polarization electron beams, produced from strained super-lattice GaAs photocathodes, activated to negative electron affinity in a photogun operating at 130 kV dc. A pair of Wien filter spin rotators in the injector defines the orientation of the electron beam polarization at the end station target. An upgrade of the CEBAF injector to better support the upcoming MOLLER experiment requires increasing the electron beam energy to 200 keV, to reduce unwanted helicity correlated intensity and position systematics and provide precise control of the polarization orientation. Our contribution describes design, fabrication and testing of the high voltage system to upgrade the Wien spin rotator to be compatible with the 200 keV beam. This required Solidworks modeling, CST and Opera electro- and magnetostatic simulations, upgrading HV vacuum feedthroughs, and assembly techniques for improving electrode alignment. The electric and magnetic fields required by the Wien condition and the successful HV characterization under vacuum conditions are also presented.

Palacios-Serrano, G.↗

Electrostatic Design and Characterization of a 200 keV Photogun and Wien Spin Rotator

High-energy nuclear physics experiments at the Jefferson Lab Continuous Electron Beam Accelerator Facility (CEBAF) require high spin-polarization electron beams produced from strained super-lattice GaAs photocathodes activated to negative electron affinity in a high voltage photogun operating at 130 kV dc. A pair of Wien filter spin rotators in the injector provides precise control of the electron beam polarization at the end station target. An upgrade of the CEBAF injector to better support the upcoming Moller experiment requires increasing the electron beam energy to 200 keV, resulting in better transmission through injector apertures and improved photocathode lifetime. In addition, the energy increase is expected to reduce unwanted helicity correlated intensity and position systematics. These requirements led to the design of a shielding electrode described in this work, which minimizes the electric field at the triple-point junction and linearizes the potential along the insulator, thus reducing the risk of field emission induced insulator arcing. The Wien spin rotator design was modified for increasing the electric field from 1.6 to 2.7 MV/m and the magnetic field from 9.1 to 13 mT. The upgrades required detailed modeling in Solidworks, electrostatic simulations using CST, beam dynamics using GPT, device implementation, and in situ high voltage characterization of the world?s first 200 keV polarized photoelectron gun and compatible Wien filter spin rotator.

Palacios-Serrano, Gabriel↗

Simulations of positron injector for Ce+BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam (1 mA, 130‑370 MeV, and 90% longitudinal polarization) that passes through a rotating, water-cooled, tungsten target. The simulation results for the Ce+BAF injector at the Low Energy Recirculator Facility (LERF) are presented, including positron beam generation, capture, energy selection, and acceleration to 123 MeV. The positron yield (or positron current) and longitudinal polarization are calculated considering the longitudinal and transverse CEBAF acceptances (<1% energy spread, <1 mm bunch length and normalized emittance of <100 mm mrad). The impact of target thickness, drive electron beam energy, and transverse size on positron yield within the required emittance limit is evaluated.

Accelerator Physics↗

Light dark matter searches with positrons

We discuss two complementary strategies to search for light dark matter (LDM) exploiting the positron beam possibly available in the future at Jefferson Laboratory. LDM is a new compelling hypothesis that identifies dark matter with new sub-GeV “hidden sector” states, neutral under standard model interactions and interacting with our world through a new force. Accelerator-based searches at the intensity frontier are uniquely suited to explore it. Thanks to the high intensity and the high energy of the Continuous Electron Beam Accelerator Facility (CEBAF) beam, and relying on a novel LDM production mechanism via positron annihilation on target atomic electrons, the proposed strategies will allow us to explore new regions in the LDM parameters space, thoroughly probing the LDM hypothesis as well as more general hidden sector scenarios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Results from A $Nb_3Sn$-Coated 1.5-Cell 650MHZ SRF Cavity for Cryogen-Free Industrial Accelerators

Fermilab is advancing the development of a compact, high-power electron beam accelerator using superconducting radio frequency (SRF) technology as a non-radioactive alternative to traditional radiological sources. The current design targets continuous-wave (CW) operation at \SI{1.6}{MeV} and \SI{20}{kW}. To ensure suitability for industrial environments, the system is being designed for cryogen-free operation, driving the adoption of a novel Nb$_3$Sn-coated 1.5-cell SRF cavity operating at \SI{650}{MHz}. This contribution reports on the fabrication, surface preparation, and Nb$_3$Sn coating process of the cavity, as well as first results from vertical test stand (VTS) measurements performed in a liquid helium bath. These initial tests mark a key milestone toward demonstrating the viability of conduction-cooled Nb$_3$Sn SRF cavities for industrial-scale deployment.

Tagdulang, Nikki Diala [Fermilab]↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗