Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Conservation Measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Three-dimensional modelling of a self-sustained atmospheric pressure glow discharge

The atmospheric pressure glow discharge (APGD) is a relatively simple and versatile plasma source used in diverse applications. Stable APGD operation at high currents, generally a challenge due to instabilities leading to glow-to-arc transition, has been demonstrated using actively-controlled cathodic cooling. This article presents the computational modelling and simulation of a self-sustained direct-current APGD in helium within a 10 mm pin-to-plate inter-electrode gap for currents ranging from 4 to 40 mA. The APGD model is comprised of the conservation equations for total mass, chemical species, momentum, thermal energy of heavy-species and of free electrons, and electric charge. The model equations are discretized using a nonlinear variational multi-scale finite element method that has demonstrated superior accuracy in other plasma flow problems, on a temporal and three-dimensional computational domain suitable to unveil the potential occurrence of instabilities. Modelling results show good agreement with experimental measurements of voltage drop and the same trend but higher values of temperature. The higher temperatures obtained by the simulations appear to be due to the absence of a near-cathode heat dissipation model. Here, the results also reveal that the distribution of electron density and of the ratio of atomic helium ions to total ions transitions from monotonically increasing away from the cathode to presenting a minimum near the centre of the gap with increasing current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Joint Oscillation Analysis of Super-Kamiokande Atmospheric and T2K Accelerator Neutrino Data

The Super-Kamiokande and T2K Collaborations present a joint measurement of neutrino oscillation parameters from their atmospheric and beam neutrino data. It uses a common interaction model for events overlapping in neutrino energy and correlated detector systematic uncertainties between the two datasets, which are found to be compatible. Using 3244.4 days of atmospheric data and a beam exposure of 19.7⁢(16.3) × 10 20 protons on target in (anti)neutrino mode, the analysis finds a 1.9⁢𝜎 exclusion of 𝐶⁢𝑃 conservation (defined as 𝐽 𝐶⁢𝑃 = 0) and a 1.2⁢𝜎 exclusion of the inverted mass ordering.

Neutrino detection↗

Boride-based Ceramic Super-high Temperature Thermocouples in Harsh Environments (Final Scientific/Technical Report)

An electromotive force (emf) can be generated along a temperature gradient between the cold end and hot end of a thermoelectric material, termed the Seebeck effect. Based on the Seebeck effect, metallic alloys have been extensively employed to detect temperatures for centuries, named thermocouples. However, commercially available thermocouple alloys suffer from limitations, such as oxidation, chemical degradation, and poor long-term stability under high-temperature harsh environments. This DOE-funded project aimed to develop high-temperature, chemically tolerant thermocouples suitable for operation in extreme environments relevant to semiconducting thermoelectric materials. The research focused on boride-based semiconducting thermoelectric compounds as candidates for next-generation thermocouples with enhanced oxidation resistance, chemical stability, and thermal robustness under conditions representative of charcoal-fired electricity facilities. During the funded years, boride materials were synthesized using an arc-plasma technique under ambient air and argon atmospheres, enabling scalable and cost-effective production compared with conventional boride fabrication methods. The synthesized borides were processed into nanostructured powders, followed by consolidation into dense bulk materials using a spark plasma sintering (SPS) bottom-up approach. Comprehensive characterization was performed, including microstructural analysis, electrical transport measurements, and optical and thermal property evaluation. Both p-type and n-type boride electric legs were fabricated and integrated into boride-based thermocouples. The thermal and irradiation stabilities of the boride nanomaterials and bulk thermoelectric materials were systematically evaluated to assess suitability for long-term operation in harsh environments. Additionally, 12 students were broadly hands-on trained spanning the full research workflow, including word processing and technical editing (e.g., LATEX for manuscript and poster preparation), data collection and analysis (using Python and related libraries and hardware interfaces), sample preparation (including arc-plasma synthesis and spark plasma sintering), and advanced characterization techniques (such as X-ray diffraction, UV–vis spectroscopy, electron microscopy, differential thermal analysis (DTA), and Seebeck coefficient measurements, etc). Overall, this project demonstrated the feasibility of boride-based thermoelectric materials as durable high-temperature thermocouples, providing a promising pathway toward robust temperature sensing technologies aligned with DOE energy infrastructure and extreme-environment monitoring needs.

20 FOSSIL-FUELED POWER PLANTS↗

CODEX weak lensing mass catalogue and implications on the mass–richness relation

The COnstrain Dark Energy with X-ray clusters (CODEX) sample contains the largest flux limited sample of X-ray clusters at 0.35 < z < 0.65. It was selected from ROSAT data in the 10 000 square degrees of overlap with BOSS, mapping a total number of 2770 high-z galaxy clusters. We present here the full results of the CFHT CODEX programme on cluster mass measurement, including a reanalysis of CFHTLS Wide data, with 25 individual lensing-constrained cluster masses. We employ lensfit shape measurement and perform a conservative colour–space selection and weighting of background galaxies. Using the combination of shape noise and an analytic covariance for intrinsic variations of cluster profiles at fixed mass due to large-scale structure, miscentring, and variations in concentration and ellipticity, we determine the likelihood of the observed shear signal as a function of true mass for each cluster. We combine 25 individual cluster mass likelihoods in a Bayesian hierarchical scheme with the inclusion of optical and X-ray selection functions to derive constraints on the slope α, normalization β, and scatter σln λ|μ of our richness–mass scaling relation model in log-space: ${\langle {\rm In}\,\, \lambda\!\!\mid\!\!\mu\rangle = \alpha\mu + \beta,} $ with μ = ln (M 200c /M piv ), and M piv = 10 14.81 M ⊙ . We find a slope $\alpha = 0.49^{+0.20}_{-0.15}$, normalization $\exp (\beta) = 84.0^{+9.2}_{-14.8}$, and $\sigma _{\ln \lambda | \mu } = 0.17^{+0.13}_{-0.09}$ using CFHT richness estimates. In comparison to other weak lensing richness–mass relations, we find the normalization of the richness statistically agreeing with the normalization of other scaling relations from a broad redshift range (0.0 < z < 0.65) and with different cluster selection (X-ray, Sunyaev–Zeldovich, and optical).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Building fault detection data to aid diagnostic algorithm creation and performance testing

It is estimated that approximately 4-5% of national energy consumption can be saved through corrections to existing commercial building controls infrastructure and resulting improvements to efficiency. Correspondingly, automated fault detection and diagnostics (FDD) algorithms are designed to identify the presence of operational faults and their root causes. A diversity of techniques is used for FDD spanning physical models, black box, and rule-based approaches. A persistent challenge has been the lack of common datasets and test methods to benchmark their performance accuracy. This article presents a first of its kind public dataset with ground-truth data on the presence and absence of building faults. This dataset spans a range of seasons and operational conditions and encompasses multiple building system types. It contains information on fault severity, as well as data points reflective of the measurements in building control systems that FDD algorithms typically have access to. The data were created using simulation models as well as experimental test facilities, and will be expanded over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Search for resonance-enhanced C P and angular asymmetries in the Λ c + → p μ + μ − decay at LHCb

The first measurement of the C P asymmetry of the decay rate ( A C P ) and the C P average ( Σ A FB ) and C P asymmetry ( Δ A FB ) of the forward-backward asymmetry in the muon system of Λ c + → p μ + μ − decays is reported. The measurement is performed using a data sample of proton-proton collisions, recorded by the LHCb experiment from 2016 to 2018 at a center-of-mass energy of 13 TeV, which corresponds to an integrated luminosity of 5.4 fb − 1 . The asymmetries are measured in two regions of dimuon mass near the ϕ -meson mass peak. The dimuon-mass integrated results are A C P = ( − 1.1 ± 4.0 ± 0.5 ) % , Σ A FB = ( 3.9 ± 4.0 ± 0.6 ) % , Δ A FB = ( 3.1 ± 4.0 ± 0.4 ) % , where the first uncertainty is statistical and the second systematic. The results are consistent with the conservation of C P symmetry and the Standard Model expectations. © 2025 CERN, for the LHCb Collaboration 2025 CERN

Aaij, R. (ORCID:0000000305331952)↗

Blueprint for Integrating Grid-Interactive Efficient Building (GEB) Technologies into U.S. General Services Administration Performance Contracts

This document provides recommended strategies for increasing implementation of grid-interactive efficient building (GEB) measures in federal performance contracts. This document outlines distributed energy resource screening processes, contractual considerations for GEB technologies within performance contracts, and guidance for integration of GEB analysis procedures and technologies into each phase of a performance contract.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Comparing simulated demand flexibility against actual performance in commercial office buildings

Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shear Assisted Processing and Extrusion (ShAPE) of Plastics: Recycling and Remolding

Polyethylene (PE) and polypropylene (PP) are often disposed as mixed plastic wastes. The challenges in recycling and upcycling these mixed polyolefin wastes lie in the difficulty in separating individual constituents in a cost-effective and scalable manner. Direct recycling the mixed PE and PP wastes in conventional melt-phase extruders typically result in a product with poor properties and low added value, because of immiscibility, phase separation, and lack of crystallinity. Friction extrusion (FE), a solid phase processing technique that has successfully extruded metal matrix composites with desired end products, has never been utilized to address the issue of recycling mixed plastic wastes. In this study, FE was performed on single-stream low-density polyethylene (LDPE), single-stream PP and mixed-stream LDPE+PP. Consolidated filaments of 2.5 mm diameter were extruded from different precursors. The thermal, infrared, and microscopic properties of extruded filaments were measured to evaluate the effects of FE process on the structure of recycled polymers. Meanwhile, the energy efficiency of FE was estimated based on extrusion rates and compared with conventional melt extrusion processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CalTestBed - Lucent Optics (CRADA Final Report)

The CRADA partner was developing a window film aimed at improving the control of the solar radiation that arrives at a building’s windows, ultimately reducing cooling loads and improving the distribution of daylight. The efforts under this CRADA were aimed at better understanding the performance of one or more prototypes of this film, with the aim of helping to narrow down the film design parameters to values more likely to achieve better performance. The technical means of achieving this project’s goals used LBNL’s world-class test facilities and expertise. These technical means included: (a) measurements of the bidirectional scattering distribution function (BSDF) of film samples, and (b) full-scale measurement of the energy (HVAC, lighting) and comfort (visual, thermal) impacts of at least one film prototype, for two solar angle “seasons” (“high” and “low” solar angle).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Credits—A New Way to Save in ASHRAE/IES Standard 90.1-2022

This article discusses a new Section 11 that has been added to Standard 90.1-2022 to increase energy savings by requiring additional energy credit measures beyond the base prescriptive requirements. This new requirement targets a 5% reduction in overall building energy cost using a broad range of additional measures. Allowing designers to choose measures that are particularly suited to a particular project provides flexibility in increasing energy savings. There are resources available to help designers implement this new requirement in Standard 90.1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ResStock 2024.2 Dataset [Slides]

In the ResStock 2024.2 dataset, ResStock runs are used to create "what-if" scenarios including energy efficiency measures such as heat pumps, envelope improvements, and electrification of appliances. This dataset release includes 15 measure packages across two weather years and incorporates ResStock improvements in variable speed heat pump modeling, geothermal heat pump modeling, and housing characteristic data updates from RECS 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Passive and active neutron signatures of 233 U for nondestructive assay

The thorium fuel cycle is emerging as an attractive alternative to conventional nuclear fuel cycles, as it does not require the enrichment of uranium for long-term sustainability. The operating principle of this fuel cycle is the irradiation of 232 Th to produce 233 U, which is fissile and sustains the fission chain reaction. 233 U poses unique challenges for nuclear safeguards, as it is associated with a uniquely extreme γ-ray environment from 232 U contamination, which limits the feasibility of the γ-ray-based assay, as well as more conservative accountability requirements than for 235 U set by the International Atomic Energy Agency. Consequently, instrumentation used for safeguarding 235 U in traditional fuel cycles may be inapplicable. It is essential that the nondestructive signatures of 233 U be characterized so that nuclear safeguards can be applied to thorium fuel-cycle facilities as they come online. In this work, a set of 233 U 3 O 8 plates, containing 984 g 233 U, was measured at the National Criticality Experiments Research Center. A high-pressure 4 He gaseous scintillation detector, which is insensitive to γ-rays, was used to perform a passive fast neutron spectral signature measurement of 233 U 3 O 8 , and was used in conjunction with a pulsed deuterium-tritium neutron generator to demonstrate the differential die-away signature of this material. Furthermore, an array of 3 He detectors was used in conjunction with the same neutron generator to measure the delayed neutron time profile of 233 U, which is unique to this nuclide. These measurements provide a benchmark for future nondestructive assay instrumentation development, and demonstrate a set of key neutron signatures to be leveraged for nuclear safeguards in the thorium fuel cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New proxies for second-order cumulants of conserved charges in heavy-ion collisions within the EPOS4 framework

Proxies for cumulants of baryon number 𝐵, electric charge 𝑄, and strangeness 𝑆 are usually measured in heavy-ion collisions via moments of net-number distribution of given hadronic species. Since these cumulants of conserved charges are expected to be sensitive to the existence of a critical point in the phase diagram of nuclear matter, it is crucial to ensure that the proxies used as substitutes are as close to them as possible. Hence, we use the EPOS 4 framework to generate Au + Au collisions at several collision energies of the BNL Relativistic Heavy Ion Collider beam energy scan. We compute second-order net cumulants of 𝜋, 𝐾, and 𝑝, for which experimental data have been published as well as the corresponding conserved charge cumulants. We then compare them with proxies, defined in previous lattice QCD and hadron resonance gas model studies, which are shown to reproduce more accurately their associated conserved charge cumulants. We investigate the impact of hadronic rescatterings occurring in the late evolution of the system on these quantities, as well as the amount of signal actually originating from the bulk medium which endures a phase transition.

Physics↗

A deep learning-based Bayesian framework for high-resolution calibration of building energy models

Calibrating building energy models (BEMs), i.e., closing discrepancy between modeling and field measurements, is of significance to support its applications in building sustainability and resilience analysis. However, as being widely used in practice, current Bayesian calibration is mostly performed in low-resolution (annual or monthly), instead of high-resolution (hourly or sub-hourly), which is crucial to support emerging BEM applications, such as building-renewable energy integration (demand response) and smart control. This is attributable to the gaps in current Bayesian calibration process, including (1) difficulty in supporting reliable high-resolution calibration with over-parameterization and multi-solution issues, (2) inadequacy of meta-model to capture temporal building dynamics in high-resolution, and (3) excessive computational burdens of covariance matrix calculation in Bayesian inference. Therefore, to close these gaps, this research proposes a novel deep learning-based Bayesian calibration framework, involving pre-calibration mechanism, Long Short-Term Memory as surrogate models, and simplified covariance matrix calculation, to calibrate BEMs in high temporal resolution (i.e., hourly) with enhanced accuracy and computational efficiency. Finally, the case study demonstrates its effectiveness to match modeling outcomes with measurements and realize CV-RMSE of < 30 % and NMBE of < 6 % in hourly resolution, as well as a significant reduction of calibration time (by > 99 %, from > 600 h to ~ 1.5 h).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Coal Industry Perspective (2020) [Slides]

This report provides an overview of the coal industry, focusing on the United States. Some of the areas covered include coal prices, consumption, production, stockpiles, imports, exports, reserves, and productivity measures. Juxtapositions between the United States and other countries coal industries are provided. In addition to providing a current snapshot of the U.S. coal industry, this work portrays both historical and projected aspects of the coal industry.

01 COAL, LIGNITE, AND PEAT↗

Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home

Extreme weather events become more frequent and severe due to climate change. Although energy efficiency technologies can influence thermal resilience of buildings, they are traditionally studied separately, and their interconnections are rarely quantified. This study developed a methodology of modeling and analysis to provide insights into the nexus of thermal resilience and energy efficiency of buildings. In this work, we conducted a case study of a real nursing home in Florida, where 12 patients died during Hurricane Irma in 2017 due to HVAC system power loss, to understand and quantify how passive and active energy efficiency measures (EEMs) can improve thermal resilience to reduce heat-exposure risk of patients. Results show that passive measures of opening windows and doors for natural ventilation, as well as miscellaneous load reduction, are very effective in eliminating the extreme dangerous occasions. However, to maintain safe conditions, active measures such as on-site power generators and thermal storage are also needed. The nursing home was further studied by changing its location to two other cities: San Francisco (mild climate) and Chicago (cold winter and hot summer). Results revealed that the EEMs' impacts on thermal resilience vary significantly by climate and building characteristics. The study also estimated the costs of EEMs to help stakeholders prioritize the measures. Passive measures that may not save energy may greatly improve thermal resilience, and thus should be considered in building design or retrofit. Findings from this study indicate energy efficiency technologies should be evaluated not only by their energy savings performance but also by their influence on a building's resilience to extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗