Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy efficient computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems

With the current movement toward net zero energy buildings, many technologies are promoted with emphasis on their superior energy efficiency. The variable refrigerant flow (VRF) and ground source heat pump (GSHP) systems are probably the most competitive technologies among these. However, there are few studies reporting the energy efficiency of VRF systems compared with GSHP systems. In this article, a preliminary comparison of energy efficiency between the air-source VRF and GSHP systems is presented. The computer simulation results show that GSHP system is more energy efficient than the air-source VRF system for conditioning a small office building in two selected US climates. In general, GSHP system is more energy efficient than the air-source VRV system, especially when the building has significant heating loads. For buildings with less heating loads, the GSHP system could still perform better than the air-source VRF system in terms of energy efficiency, but the resulting energy savings may be marginal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low Power, Radiation Resilient Synchronous Edge Processing for Remote Monitoring

Next-generation space remote sensing systems may be equipped with imaging arrays that sense data at a rate that outstrips the processing capability of any computing hardware that can operate within a satellite’s power budget. This project developed novel convolutional and recurrent neural networks to detect and estimate point-like events amid clutter, and investigated their efficient and accurate implementation on analog in-memory computing systems that are 10-1000× more energy-efficient than digital processors. This project leveraged two memory devices at different levels of technological maturity: a large-scale analog computing prototype using commercial SONOS charge-trap memory, and electrochemical memory (ECRAM) with intrinsic radiation hardness. We experimentally demonstrated end-to-end analog processing of our neural networks on SONOS and characterized the radiation response of both SONOS and ECRAM. We advanced the state-of-the-art in ECRAM precision and reliability, and developed co-design methods to enable accurate long-term operation of SONOS analog accelerators in space radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupling Deterministic and Monte Carlo Transport Methods for the Simulation of Gamma-Ray Spectroscopy Scenarios

Radiation transport modeling methods used in the radiation detection community fall into one of two broad categories: stochastic (Monte Carlo) and deterministic. Monte Carlo methods are typically the tool of choice for simulating gamma-ray spectrometers operating in homeland and national security settings (e.g. portal monitoring of vehicles or isotope identification using handheld devices), but deterministic codes that discretize the linear Boltzmann transport equation in space, angle, and energy offer potential advantages in computational efficiency for many complex radiation detection problems. This paper describes the development of a scenario simulation framework based on deterministic algorithms. Key challenges include: formulating methods to automatically define an energy group structure that can support modeling of gamma-ray spectrometers ranging from low to high resolution; combining deterministic transport algorithms (e.g. ray-tracing and discrete ordinates) to mitigate ray effects for a wide range of problem types; and developing efficient and accurate methods to calculate gamma-ray spectrometer response functions from the deterministic angular flux solutions. The software framework aimed at addressing these challenges is described and results from test problems that compare coupled deterministic-Monte Carlo methods and purely Monte Carlo approaches are provided.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Analytical energy gradient based on spin-free infinite-order Douglas-Kroll-Hess method with local unitary transformation

In this study, the analytical energy gradient for the spin-free infinite-order Douglas-Kroll-Hess (IODKH) method at the levels of the Hartree-Fock (HF), density functional theory (DFT), and second-order Møller-Plesset perturbation theory (MP2) is developed. Furthermore, adopting the local unitary transformation (LUT) scheme for the IODKH method improves the efficiency in computation of the analytical energy gradient. Numerical assessments of the present gradient method are performed at the HF, DFT, and MP2 levels for the IODKH with and without the LUT scheme. The accuracies are examined for diatomic molecules such as hydrogen halides, halogen dimers, coinage metal (Cu, Ag, and Au) halides, and coinage metal dimers, and 20 metal complexes, including the fourth–sixth row transition metals. In addition, the efficiencies are investigated for one-, two-, and three-dimensional silver clusters. The numerical results confirm the accuracy and efficiency of the present method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Power-Capping Metric Evaluation for Improving Energy Efficiency in HPC Applications

With high-performance computing systems now running at exascale, optimizing power-scaling management and resource utilization has become more critical than ever. This paper explores runtime power-capping optimizations that leverage integrated CPU-GPU power management on architectures like the NVIDIA GH200 superchip. We evaluate energy-performance metrics that account for simultaneous CPU and GPU power-capping effects by using two complementary approaches: speedup-energy-delay and a Euclidean distance-based multi-objective optimization method. By targeting a mostly compute-bound exascale science application, the Locally Self-Consistent Multiple Scattering (LSMS), we explore challenging scenarios to identify potential opportunities for energy savings in exascale applications, and we recognize that even modest reductions in energy consumption can have significant overall impacts. Our results highlight how GPU task-specific dynamic power-cap adjustments combined with integrated CPU-GPU power steering can improve the energy utilization of certain GPU tasks, thereby laying the groundwork for future adaptive optimization strategies.

Patrou, Maria [ORNL] (ORCID:0000000339754638)↗

The absorption of energetic electrons by molecular hydrogen gas

The processes by which energetic electrons lose energy in a weakly ionized gas of molecular hydrogen are analyzed, and calculations are carried out taking into account the discrete nature of the excitation processes. The excitation, ionization, and heating efficiencies are computed for electrons with energies up to 100 eV absorbed in a gas with fractional ionizations up to 0.01, and the mean energy per pair of neutral hydrogen atoms is calculated.

Cravens, T. E.↗

Simplifying Energy Efficiency for Homeowners - Results from a California Utility's Pilot Study of a Scalable Solution to Assess Retrofit and Solar Opportunities: Preprint

For homeowners, typical choices to reduce net energy use in their homes include: upgrading their home with a tailored efficiency retrofit or investing in roof-top solar. Determining the unique combination of these options that will provide the most cost-effective solution requires analysis for each home. This analysis needs to be presented in a simple and actionable way to homeowners. The solution should also be easily scalable to thousands of homes to enable utilities to better target efficiency program options and support solar installations. Sacramento Municipal Utility District (SMUD) piloted a new tool developed by Vistar Energy called XeroHome that automates the assessment of energy efficiency and solar opportunities in existing homes. XeroHome demonstrates an approach to using building energy modeling, energy use data analytics and homeowner engagement to identify and target energy efficiency opportunities at scale. XeroHome uses automation to build an EnergyPlus model for each home, based on information from public data sources such as property assessment records, building permit records, aerial/satellite photography, and template models derived from ResStock. Utilizing cloud computing, machine learning and optimization algorithms, energy upgrade packages are ranked by cost-effectiveness for each home and presented over an interactive web-portal. This paper discusses SMUD's pilot project using XeroHome to conduct analysis for 1,500 existing homes in Sacramento, CA. Development of XeroHome's advanced analytics capabilities are discussed in the context of applicability for utility programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplifying Energy Efficiency for Homeowners - Results from a California Utility's Pilot Study of a Scalable Solution to Assess Retrofit and Solar Opportunities

For homeowners, typical choices to reduce net energy use in their homes include: upgrading their home with a tailored efficiency retrofit or investing in roof-top solar. Determining the unique combination of these options that will provide the most cost-effective solution requires analysis for each home. This analysis needs to be presented in a simple and actionable way to homeowners. The solution should also be easily scalable to thousands of homes to enable utilities to better target efficiency program options and support solar installations. Sacramento Municipal Utility District (SMUD) piloted a new tool developed by Vistar Energy called XeroHome that automates the assessment of energy efficiency and solar opportunities in existing homes. XeroHome demonstrates an approach to using building energy modeling, energy use data analytics and homeowner engagement to identify and target energy efficiency opportunities at scale. XeroHome uses automation to build an EnergyPlus model for each home, based on information from public data sources such as property assessment records, building permit records, aerial/satellite photography, and template models derived from ResStock. Utilizing cloud computing, machine learning and optimization algorithms, energy upgrade packages are ranked by cost-effectiveness for each home and presented over an interactive web-portal. This paper discusses SMUD's pilot project using XeroHome to conduct analysis for 1,500 existing homes in Sacramento, CA. Development of XeroHome's advanced analytics capabilities are discussed in the context of applicability for utility programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Balanced Excitatory and Inhibitory Synaptic Currents Promote Efficient Coding and Metabolic Efficiency

A balance between excitatory and inhibitory synaptic currents is thought to be important for several aspects of information processing in cortical neurons in vivo, including gain control, bandwidth and receptive field structure. These factors will affect the firing rate of cortical neurons and their reliability, with consequences for their information coding and energy consumption. Yet how balanced synaptic currents contribute to the coding efficiency and energy efficiency of cortical neurons remains unclear. We used single compartment computational models with stochastic voltage-gated ion channels to determine whether synaptic regimes that produce balanced excitatory and inhibitory currents have specific advantages over other input regimes. Specifically, we compared models with only excitatory synaptic inputs to those with equal excitatory and inhibitory conductances, and stronger inhibitory than excitatory conductances (i.e. approximately balanced synaptic currents). Using these models, we show that balanced synaptic currents evoke fewer spikes per second than excitatory inputs alone or equal excitatory and inhibitory conductances. However, spikes evoked by balanced synaptic inputs are more informative (bits/spike), so that spike trains evoked by all three regimes have similar information rates (bits/s). Consequently, because spikes dominate the energy consumption of our computational models, approximately balanced synaptic currents are also more energy efficient than other synaptic regimes. Thus, by producing fewer, more informative spikes approximately balanced synaptic currents in cortical neurons can promote both coding efficiency and energy efficiency.

59 BASIC BIOLOGICAL SCIENCES↗

IceNet for FireBox - A Berkeley Warehouse-Scale Computer

Berkeley’s FireBox is a next-generation warehouse-scale computer (WSC) that utilizes the energy-efficiency and bandwidth density of integrated silicon-photonic interconnects to enable a new high-bandwidth and low-latency network fabric connecting thousands of compute nodes to petabytes of DRAM and Flash storage. The high bandwidth, low latency and high connectivity of FireBox’s WSC network fabric (IceNet) will enable dramatic improvements in the overall system energy efficiency enabling fine-grain power control on system resources (processors, links and memory/storage components). IceNet is a special 3-stage photonic Clos network architected to achieve ultra-low-latency connectivity between processor nodes and memory, drastically cutting down on the energy wasted in resource idling (processors and memory stalled due to pending network requests). This is achieved by integration of the first and last switch stages into processor/memory hub clients and by heavy over-provisioning of the high-radix middle switches (FlareSwitches). A key hardware component developed in this program is an active laser power management photonic integrated circuits called LightSpark. It interacts with the FlareSwitch and provides laser power to a subset of occupied switch ports, increasing the utilization of laser light in the photonic network by an order of magnitude. In addition to guiding the laser power where it is needed, the laser-power management module enables both wavelength and laser redundancy, significantly increasing the robustness of the system. The goal of the IceNet fabric is to enable communication between 1000s of processor nodes and PBs of memory/storage with <100ns latency, <10pJ/b wall-plug energy cost at multiple Pb/s of available connectivity bandwidth. These metrics represent two-orders of magnitude improvement with respect to the status of current data-center technology.

42 ENGINEERING↗

Demonstration of Intelligent Control and Fan Improvements in Computer Room Air Handlers

This report documents a demonstration of the energy-efficiency improvement provided by a new control system for computer room air handling devices. It also analyzes measured and reported air handling device fan power associated with changing the fan type. A 135,000 square foot commercial data center was used for the demonstration. All air handling units were upgraded with improved efficiency fans, and a control system that automatically adjusts the fan speed for the air handling units was added. Power measurements were collected for a baseline and for a period with the fan speed control system active. Changing the fan type resulted in a savings of 47 percent of energy used by the air handling equipment and associated chiller plant energy needed to cool the air handlers themselves. The addition of the fan speed control resulted in an additional 37 percent savings in the same two categories. The combined savings for the two improvements for the same categories was 66 percent compared to the data center fitted with the original fans without a control system. The energy use reduction provided by the complete air handling device improvement program for the whole data center site is estimated to be 2.9 million kilowatt hours per year—an overall data center site savings of 8.0 percent. The reduced electrical energy use at the site provides a 1.9 million pound yearly reduction of carbon dioxide emissions. This demonstration showed that fan upgrades and a control system addition provide cost-effective improvements for data centers, with a payback reported to be under two years without utility incentives. In addition to the control system providing energy savings, the data collection and visual analysis capabilities provided immediate and long-term benefits. It is recommended that data center operators consider investing in fan upgrades and/or adding fan speed control for computer room air handlers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating a Nationally Representative Housing Sample Using EnergyPlus

This report presents a new simulation tool under development at Lawrence Berkeley National Laboratory (LBNL). This tool uses EnergyPlus to simulate each single-family home in the Residential Energy Consumption Survey (RECS), and generates a calibrated, nationally representative set of simulated homes whose energy use is statistically indistinguishable from the energy use of the single-family homes in the RECS sample. This research builds upon earlier work by Ritchard et al. for the Gas Research Institute and Huang et al. for LBNL. A representative national sample allows us to evaluate the variance in energy use between individual homes, regions, or other subsamples; using this tool, we can also evaluate how that variance affects the impacts of potential policies. The RECS contains information regarding the construction and location of each sampled home, as well as its appliances and other energy-using equipment. We combined this data with the home simulation prototypes developed by Huang et al. to simulate homes that match the RECS sample wherever possible. Where data was not available, we used distributions, calibrated using the RECS energy use data. Each home was assigned a best-fit location for the purposes of weather and some construction characteristics. RECS provides some detail on the type and age of heating, ventilation, and air-conditioning (HVAC) equipment in each home; we developed EnergyPlus models capable of reproducing the variety of technologies and efficiencies represented in the national sample. This includes electric, gas, and oil furnaces, central and window air conditioners, central heat pumps, and baseboard heaters. We also developed a model of duct system performance, based on in-home measurements, and integrated this with fan performance to capture the energy use of single- and variable-speed furnace fans, as well as the interaction of duct and fan performance with the efficiency of heating and cooling equipment. Comparison with RECS revealed that EnergyPlus did not capture the heating-side behavior of heat pumps particularly accurately, and that our simple oil furnace and boiler models needed significant recalibration to fit with RECS. Simulating the full RECS sample on a single computer would take many hours, so we used the 'cloud computing' services provided by Amazon.com to simulate dozens of homes at once. This enabled us to simulate the full RECS sample, including multiple versions of each home to evaluate the impact of marginal changes, in less than 3 hours. Once the tool was calibrated, we were able to address several policy questions. We made a simple measurement of the heat replacement effect and showed that the net effect of heat replacement on primary energy use is likely to be less than 5%, relative to appliance-only measures of energy savings. Fuel switching could be significant, however. We also evaluated the national and regional impacts of a variety of 'overnight' changes in building characteristics or occupant behavior, including lighting, home insulation and sealing, HVAC system efficiency, and thermostat settings. For example, our model shows that the combination of increased home insulation and better sealed building shells could reduce residential natural gas use by 34.5% and electricity use by 6.5%, and a 1 degree rise in summer thermostat settings could save 2.1% of home electricity use. These results vary by region, and we present results for each U.S. Census division. We conclude by offering proposals for future work to improve the tool. Some proposed future work includes: comparing the simulated energy use data with the monthly RECS bill data; better capturing the variation in behavior between households, especially as it relates to occupancy and schedules; improving the characterization of recent construction and its regional variation; and extending the general framework of this simulation tool to capture multifamily housing units, such as apartment buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A chain-of-states acceleration method for the efficient location of minimum energy paths

We describe a robust and efficient chain-of-states method for computing Minimum Energy Paths (MEPs) associated to barrier-crossing events in poly-atomic systems, which we call the acceleration method. The path is parametrized in terms of a continuous variable t ∈ [0, 1] that plays the role of time. In contrast to previous chain-of-states algorithms such as the nudged elastic band or string methods, where the positions of the states in the chain are taken as variational parameters in the search for the MEP, our strategy is to formulate the problem in terms of the second derivatives of the coordinates with respect to t, i.e., the state accelerations. We show this to result in a very simple and efficient method for determining the MEP. We describe the application of the method to a series of test cases, including two low-dimensional problems and the Stone-Wales transformation in C{sub 60}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Applied Mathematics for Power Systems (AMPS)

Increased deployment of new technologies, e.g., renewable generation and electric vehicles, is rapidly transforming electrical power networks by crossing previously distinct spatiotemporal scales and invalidating many traditional approaches for designing, analyzing, and operating power grids. This trend is expected to accelerate over the coming years, bringing the disruptive challenge of complexity, but also opportunities to deliver unprecedented efficiency and reliability. Our Applied Mathematics for Power Systems (AMPS) Center will discover, enable, and solve emerging mathematics challenges arising in power systems and, more generally, in complex engineered networks. We will develop foundational applied mathematics resulting in rigorous algorithms and simulation toolboxes for modern and future engineered networks. The AMPS Center deconstruction/reconstruction approach 'deconstructs' complex networks into sub-problems within non-separable spatiotemporal scales, a missing step in 20th century modeling of engineered networks. These sub-problems are addressed within the appropriate AMPS foundational pillar - complex systems, control theory, and optimization theory - and merged or 'reconstructed' at their boundaries into more general mathematical descriptions of complex engineered networks where important new questions are formulated and attacked. These two steps, iterated multiple times, will bridge the growing chasm between the legacy power grid and its future as a complex engineered network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Future with Quantum Machine Learning

Could combining quantum computing and machine learning with Moore's law produce a true “rebooted computer”? Furthermore, this article posits that a three-technology hybrid-computing approach might yield sufficiently improved answers to a broad class of problems such that energy efficiency will no longer be the dominant concern.

97 MATHEMATICS AND COMPUTING↗

UltraLiM: In-Memory Boolean Logic Architecture Using UltraRAM

Conventional computing architectures encounter ‘von Neumann’ and ‘memory wall’ bottlenecks which arise due to the back-and-forth data movement between the physically separate memory and processing units and the speed mismatch between them, respectively. These bottlenecks hurt both energy efficiency and the throughput of computing systems. To address these challenges, in-memory computing architectures have emerged as a promising alternative. They reduce the need for frequent data movement by executing different computing tasks inside the memory system. Here, we present UltraLiM, a logic-in-memory architecture using the UltraRAM-based memory system. UltraRAM holds the promise of developing a ‘universal memory’, overcoming the limitations of charge-based memories thanks to their non-volatile behavior with lower operating voltage. This work presents an in-memory computing architecture that integrates an UltraRAM-based memory array with a custom-designed peripheral circuitry. With this architecture, we can perform various in-memory Boolean logic operations (such as NOT, NAND, NOR, and XOR) in a single cycle. Leveraging the separate read-write paths in the UltraRAM-based memory array, we optimize read operations without encountering design conflicts. This optimization enhances the sense margin, enabling the use of simpler peripheral circuitry for in-memory logic operations.

Alam, Shamiul [University of Tennessee, Knoxville ↗

Validation of Building Energy Modeling Tools Under Idealized and Realistic Conditions

Building energy models provide valuable insight into the energy use of commercial and residential buildings based on the building architecture, materials and thermal loads. They are used in the design of new buildings and the retrofitting to increase the efficiency of older buildings. The accuracy of these models is crucial to reducing the energy use of the United States and building a sustainable energy future. In addition to the architecture and thermal loads of a building, building energy models also must account for the effects of the building's occupants on the energy use of the building. Traditionally simple schedule based methods have been used to account for the effects of the occupants. However, newer research has shown that these methods often result in large differences between the modeled and actual energy use of buildings. In this paper we discuss building energy models and their accuracy in predicting building energy use. In particular we focus on the different types of validation methods which have been used to investigate the accuracy of building energy models and how they account for (or do not account for) the effects of occupants. We also review some of the newer work on stochastic methods for estimating the effects of occupants on building energy use and discuss the improvements necessary to increase the accuracy of building energy models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of strontium oxide functionalized graphene nanoflakes for enhanced photocatalytic activity: A density functional theory approach

A series of strontium oxide functionalized graphene nanoflakes were designed and their optoelectronic properties were studied for enhanced photocatalytic activity. The efficiency of designed molecules was studied using various parameters such as HOMO-LUMO energy gap, light harvesting efficiency and exciton binding energy. The computed results show that by increasing the degree of functionalization of strontium oxide leads to lowering the band gap of hydrogen terminated graphene nanoflakes. Furthermore, the study explores the role of strontium oxide functionalization in Frontier Molecular Orbitals, ionization potential, electron affinity, exciton binding energy and light harvesting efficiency of designed molecules. The infrared and Raman spectra were simulated for pure and SrO functionalized graphene nanoflakes. The electron rich and electron deficient regions which are favorable for electrophilic and nucleophilic attacks respectively were analyzed using molecular electrostatic potential surface analysis.

77 NANOSCIENCE AND NANOTECHNOLOGY↗